메뉴 건너뛰기




Volumn 23, Issue 3, 2013, Pages 222-227

Cadaveric and in vivo human joint imaging based on differential phase contrast by X-ray Talbot-Lau interferometry

Author keywords

A new imaging technology; Cadavers and normal volunteers; In vivo imaging; X ray interferometry

Indexed keywords

ARTICLE; CADAVER; COMPUTER; GRATING; HUMAN; HUMAN EXPERIMENT; HUMAN TISSUE; IMAGE ANALYSIS; IMAGE PROCESSING; IMAGING SYSTEM; IN VIVO STUDY; INTERFEROMETER; INTERFEROMETRY; JOINT RADIOGRAPHY; NORMAL HUMAN; PHASE CONTRAST RADIOGRAPHY; RADIATION DETECTOR; RADIOGRAPHY; SENSITIVITY ANALYSIS; SENSOR; VOLUNTEER; X RAY; X RAY TUBE;

EID: 84881547771     PISSN: 09393889     EISSN: 18764436     Source Type: Journal    
DOI: 10.1016/j.zemedi.2012.11.004     Document Type: Article
Times cited : (62)

References (10)
  • 1
    • 31544450749 scopus 로고    scopus 로고
    • Recent Advances in X-ray Phase Imaging
    • Momose A. Recent Advances in X-ray Phase Imaging. Jpn J Appl Phys 2005, 44:6355-6367.
    • (2005) Jpn J Appl Phys , vol.44 , pp. 6355-6367
    • Momose, A.1
  • 2
    • 0000741812 scopus 로고
    • Facts Relating to Optical Science
    • Talbot H.F. Facts Relating to Optical Science. Philos Mag 1836, 9:401-407.
    • (1836) Philos Mag , vol.9 , pp. 401-407
    • Talbot, H.F.1
  • 5
    • 33645795432 scopus 로고    scopus 로고
    • Phase Retrieval and Differential Phase-Contrast Imaging with Low-Brilliance X-ray Sources
    • Pfeiffer F., Weitkamp T., Bunk O., David C. Phase Retrieval and Differential Phase-Contrast Imaging with Low-Brilliance X-ray Sources. Nat Phys 2006, 2:258-261.
    • (2006) Nat Phys , vol.2 , pp. 258-261
    • Pfeiffer, F.1    Weitkamp, T.2    Bunk, O.3    David, C.4
  • 6
    • 55049087592 scopus 로고    scopus 로고
    • Efficiency of Capturing a Phase Image Using Cone-Beam X-ray Talbot Interferometry
    • Yashiro W., Takeda Y., Momose A. Efficiency of Capturing a Phase Image Using Cone-Beam X-ray Talbot Interferometry. J Opt Soc Am A 2008, 25:2025-2039.
    • (2008) J Opt Soc Am A , vol.25 , pp. 2025-2039
    • Yashiro, W.1    Takeda, Y.2    Momose, A.3
  • 8
    • 77955592118 scopus 로고    scopus 로고
    • On the Origin of Visibility Contrast in X-ray Talbot Interferometry
    • Yashiro W., Terui Y., Kawabata K., Momose A. On the Origin of Visibility Contrast in X-ray Talbot Interferometry. Opt Express 2010, 18:16890-16901.
    • (2010) Opt Express , vol.18 , pp. 16890-16901
    • Yashiro, W.1    Terui, Y.2    Kawabata, K.3    Momose, A.4
  • 9
    • 34547902908 scopus 로고    scopus 로고
    • Fabrication of Diffracting Grating with Height Aspect Ratio Using X-ray Lithography Technique for X-ray Phase Imaging
    • Noda D., Tanaka M., Shimada K., Hattori T. Fabrication of Diffracting Grating with Height Aspect Ratio Using X-ray Lithography Technique for X-ray Phase Imaging. Jpn J Appl Phys 2007, 46:849-851.
    • (2007) Jpn J Appl Phys , vol.46 , pp. 849-851
    • Noda, D.1    Tanaka, M.2    Shimada, K.3    Hattori, T.4
  • 10
    • 80052071420 scopus 로고    scopus 로고
    • Talbot phase-contrast X-ray imaging for the small joints of the hand
    • Stutman D., Beck T.J., Carrino J.A., Bingham C.O. Talbot phase-contrast X-ray imaging for the small joints of the hand. Phys Med Biol 2011, 56:5697-5720.
    • (2011) Phys Med Biol , vol.56 , pp. 5697-5720
    • Stutman, D.1    Beck, T.J.2    Carrino, J.A.3    Bingham, C.O.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.