메뉴 건너뛰기




Volumn 43, Issue 9, 2013, Pages 911-917

The microstructure and electrochemical properties of boron-doped nanocrystalline diamond film electrodes and their application in non-enzymatic glucose detection

Author keywords

Boron doped diamond film; Electrochemical properties; Microstructure; Non enzymatic glucose sensor

Indexed keywords

BORON-DOPED DIAMOND FILMS; CYCLIC VOLTAMMOGRAMS; ELECTRODE REACTIONS; MICROWAVE PLASMA CHEMICAL VAPOR DEPOSITIONS; NANO-CRYSTALLINE DIAMONDS; NANOCRYSTALLINE DIAMOND FILMS; NON-ENZYMATIC GLUCOSE SENSORS; SELECTIVE DETECTION;

EID: 84881539306     PISSN: 0021891X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10800-013-0587-5     Document Type: Article
Times cited : (11)

References (32)
  • 1
    • 18444388289 scopus 로고    scopus 로고
    • Diamond power devices: Concepts and limits
    • 10.1016/j.diamond.2004.12.043 1:CAS:528:DC%2BD2MXjsV2htbk%3D
    • Denisenko A, Kohn E (2005) Diamond power devices: concepts and limits. Diam Relat Mater 14:491-498
    • (2005) Diam Relat Mater , vol.14 , pp. 491-498
    • Denisenko, A.1    Kohn, E.2
  • 2
    • 0033738633 scopus 로고    scopus 로고
    • Recent advances in electrochemistry of diamond
    • 10.1016/S0925-9635(99)00234-4
    • Rao TN, Fujishima A (2009) Recent advances in electrochemistry of diamond. Diam Relat Mater 9:384-389
    • (2009) Diam Relat Mater , vol.9 , pp. 384-389
    • Rao, T.N.1    Fujishima, A.2
  • 3
    • 0142122642 scopus 로고    scopus 로고
    • Electroanalysis at diamond-like and doped-diamond electrodes
    • 10.1002/elan.200302830 1:CAS:528:DC%2BD3sXotFKksrg%3D
    • Compton RG, Foord JS, Marken F (2003) Electroanalysis at diamond-like and doped-diamond electrodes. Electroanalysis 15:1349-1363
    • (2003) Electroanalysis , vol.15 , pp. 1349-1363
    • Compton, R.G.1    Foord, J.S.2    Marken, F.3
  • 4
    • 4143101398 scopus 로고    scopus 로고
    • Covalently modified silicon and diamond surfaces: Resistance to nonspecific protein adsorption and optimization for biosensing
    • 10.1021/ja047642x 1:CAS:528:DC%2BD2cXmtVKktbs%3D
    • Lasseter TL, Clare BH, Abbott NL, Hamers RJ (2004) Covalently modified silicon and diamond surfaces: resistance to nonspecific protein adsorption and optimization for biosensing. J Am Chem Soc 126:10220-10221
    • (2004) J Am Chem Soc , vol.126 , pp. 10220-10221
    • Lasseter, T.L.1    Clare, B.H.2    Abbott, N.L.3    Hamers, R.J.4
  • 5
    • 0034234621 scopus 로고    scopus 로고
    • Electron transfer from diamond electrodes to hemepeptide and peroxidase
    • 10.1021/ac0000022 1:CAS:528:DC%2BD3cXivVGktbc%3D
    • Tatsuma T, Mori H, Fujishima A (2000) Electron transfer from diamond electrodes to hemepeptide and peroxidase. Anal Chem 72:2919-2924
    • (2000) Anal Chem , vol.72 , pp. 2919-2924
    • Tatsuma, T.1    Mori, H.2    Fujishima, A.3
  • 6
    • 77950562846 scopus 로고    scopus 로고
    • Construction and high performance of a novel modified boron-doped diamond film electrode endowed with superior electrocatalysis
    • 10.1021/jp909248w 1:CAS:528:DC%2BC3cXivVaisb0%3D
    • Zhao GH, Li PQ, Nong FQ, Li MF, Gao JX, Li DM (2010) Construction and high performance of a novel modified boron-doped diamond film electrode endowed with superior electrocatalysis. J Phys Chem C 114:5906-5908
    • (2010) J Phys Chem C , vol.114 , pp. 5906-5908
    • Zhao, G.H.1    Li, P.Q.2    Nong, F.Q.3    Li, M.F.4    Gao, J.X.5    Li, D.M.6
  • 7
    • 33845516284 scopus 로고    scopus 로고
    • Amperometric biosensor based on tyrosinase immobilized on a boron-doped diamond electrode
    • 10.1016/j.bios.2006.03.001 1:CAS:528:DC%2BD28XhtlalsbzP
    • Zhou YL, Tian RH, Zhi JF (2007) Amperometric biosensor based on tyrosinase immobilized on a boron-doped diamond electrode. Biosens Bioelectron 22:822-828
    • (2007) Biosens Bioelectron , vol.22 , pp. 822-828
    • Zhou, Y.L.1    Tian, R.H.2    Zhi, J.F.3
  • 9
    • 63849086169 scopus 로고    scopus 로고
    • Biofunctionalization of vertically aligned diamond nanowires
    • 10.1002/adfm.200801392 1:CAS:528:DC%2BD1MXktFWgu70%3D
    • Yang NJ, Uetsuka H, Nebel CE (2009) Biofunctionalization of vertically aligned diamond nanowires. Adv Funct Mater 19:887-893
    • (2009) Adv Funct Mater , vol.19 , pp. 887-893
    • Yang, N.J.1    Uetsuka, H.2    Nebel, C.E.3
  • 10
    • 39649091200 scopus 로고    scopus 로고
    • Direct electrochemistry of glucose oxidase and biosensing for glucose based on boron-doped carbon nanotubes modified electrode
    • 10.1016/j.bios.2007.11.009 1:CAS:528:DC%2BD1cXislWjtbY%3D
    • Deng CY, Chen JH, Chen XL, Xiao CH, Nie LH, Yao SZ (2008) Direct electrochemistry of glucose oxidase and biosensing for glucose based on boron-doped carbon nanotubes modified electrode. Biosens Bioelectron 23:1272-1277
    • (2008) Biosens Bioelectron , vol.23 , pp. 1272-1277
    • Deng, C.Y.1    Chen, J.H.2    Chen, X.L.3    Xiao, C.H.4    Nie, L.H.5    Yao, S.Z.6
  • 11
    • 2442459852 scopus 로고    scopus 로고
    • Diamond and carbon nanotube glucose sensors based on electropolymerization
    • 10.1016/j.diamond.2003.11.009 1:CAS:528:DC%2BD2cXjvVaitb4%3D
    • Loh KP, Zhao SL, Zhang WD (2004) Diamond and carbon nanotube glucose sensors based on electropolymerization. Diam Relat Mater 13:1075-1079
    • (2004) Diam Relat Mater , vol.13 , pp. 1075-1079
    • Loh, K.P.1    Zhao, S.L.2    Zhang, W.D.3
  • 12
    • 33750343642 scopus 로고    scopus 로고
    • Nanocrystalline diamond modified gold electrode for glucose biosensing
    • 10.1016/j.bios.2006.01.026
    • Zhao W, Xu JJ, Qiu QQ, Chen HY (2006) Nanocrystalline diamond modified gold electrode for glucose biosensing. Biosens Bioelectron 26:649-655
    • (2006) Biosens Bioelectron , vol.26 , pp. 649-655
    • Zhao, W.1    Xu, J.J.2    Qiu, Q.Q.3    Chen, H.Y.4
  • 13
    • 33644885281 scopus 로고    scopus 로고
    • Covalent immobilization of glucose oxidase on conducting ultrananocrystalline diamond thin films
    • 10.1016/j.diamond.2005.09.017 1:CAS:528:DC%2BD28Xit1Cgtr8%3D
    • Wang J, Carlisle JA (2006) Covalent immobilization of glucose oxidase on conducting ultrananocrystalline diamond thin films. Diam Relat Mater 15:279-284
    • (2006) Diam Relat Mater , vol.15 , pp. 279-284
    • Wang, J.1    Carlisle, J.A.2
  • 15
    • 33751221346 scopus 로고    scopus 로고
    • A selective detection method derived from controlled diffusion process at metal-modified diamond electrodes
    • 10.1021/ac060860j 1:CAS:528:DC%2BD28XhtFSit7jI
    • Watanabe T, Ivandini TA, Makide Y, Fujishima A, Einaga Y (2006) A selective detection method derived from controlled diffusion process at metal-modified diamond electrodes. Anal Chem 78:7857-7860
    • (2006) Anal Chem , vol.78 , pp. 7857-7860
    • Watanabe, T.1    Ivandini, T.A.2    Makide, Y.3    Fujishima, A.4    Einaga, Y.5
  • 16
    • 59049092519 scopus 로고    scopus 로고
    • A direct electrochemical method for diabetes diagnosis based on as-prepared boron-doped nanocrystalline diamond thin film electrodes
    • 10.1016/j.jelechem.2008.11.007 1:CAS:528:DC%2BD1MXht1altrs%3D
    • Zhao JW, Wu DH, Zhi JF (2009) A direct electrochemical method for diabetes diagnosis based on as-prepared boron-doped nanocrystalline diamond thin film electrodes. J Electroanal Chem 626:98-102
    • (2009) J Electroanal Chem , vol.626 , pp. 98-102
    • Zhao, J.W.1    Wu, D.H.2    Zhi, J.F.3
  • 17
    • 67149088467 scopus 로고    scopus 로고
    • Non-enzymatic glucose detection using as-prepared boron-doped diamond thin-film electrodes
    • 10.1039/b819303g 1:CAS:528:DC%2BD1MXjsFagu74%3D
    • Zhao JW, Wu LZ, Zhi JF (2009) Non-enzymatic glucose detection using as-prepared boron-doped diamond thin-film electrodes. Analyst 134:794-799
    • (2009) Analyst , vol.134 , pp. 794-799
    • Zhao, J.W.1    Wu, L.Z.2    Zhi, J.F.3
  • 18
    • 69549113218 scopus 로고    scopus 로고
    • Fabrication of boron-doped diamond nanorod forest electrodes and their application in nonenzymatic amperometric glucose biosensing
    • 10.1021/nn9003154 1:CAS:528:DC%2BD1MXovVemurw%3D
    • Luo DB, Wu LZ, Zhi JF (2009) Fabrication of boron-doped diamond nanorod forest electrodes and their application in nonenzymatic amperometric glucose biosensing. ACS NANO 3:2121-2128
    • (2009) ACS NANO , vol.3 , pp. 2121-2128
    • Luo, D.B.1    Wu, L.Z.2    Zhi, J.F.3
  • 19
    • 34250696919 scopus 로고    scopus 로고
    • Selective and sensitive electrochemical detection of glucose in neutral solution using platinum-lead alloy nanoparticle/carbon nanotube nanocomposites
    • 10.1016/j.aca.2007.05.047 1:CAS:528:DC%2BD2sXmvVeltrw%3D
    • Cui HF, Ye JS, Zhang WD, Li CM, Luong JHT, Sheu FS (2007) Selective and sensitive electrochemical detection of glucose in neutral solution using platinum-lead alloy nanoparticle/carbon nanotube nanocomposites. Anal Chim Acta 594:175-183
    • (2007) Anal Chim Acta , vol.594 , pp. 175-183
    • Cui, H.F.1    Ye, J.S.2    Zhang, W.D.3    Li, C.M.4    Luong, J.H.T.5    Sheu, F.S.6
  • 20
    • 20444491476 scopus 로고    scopus 로고
    • Direct electrochemical assay of glucose using boron-doped diamond electrodes
    • 10.1016/j.aca.2005.04.058 1:CAS:528:DC%2BD2MXlsFGjurs%3D
    • Lee JW, Park SM (2005) Direct electrochemical assay of glucose using boron-doped diamond electrodes. Anal Chim Acta 545:27-32
    • (2005) Anal Chim Acta , vol.545 , pp. 27-32
    • Lee, J.W.1    Park, S.M.2
  • 21
    • 7544229432 scopus 로고    scopus 로고
    • Electroanalytical application of modified diamond electrodes
    • 10.1016/j.diamond.2004.07.004 1:CAS:528:DC%2BD2cXpt1WlsbY%3D
    • Ivandini TA, Sato R, Makide Y, Fujishima A, Einaga Y (2004) Electroanalytical application of modified diamond electrodes. Diam Relat Mater 13:2003-2008
    • (2004) Diam Relat Mater , vol.13 , pp. 2003-2008
    • Ivandini, T.A.1    Sato, R.2    Makide, Y.3    Fujishima, A.4    Einaga, Y.5
  • 22
    • 73449123342 scopus 로고    scopus 로고
    • A highly sensitive nonenzymatic glucose sensor based on CuO nanoparticles-modified carbon nanotube electrode
    • 10.1016/j.bios.2009.10.038 1:CAS:528:DC%2BC3cXktVajsg%3D%3D
    • Jiang LC, Zhang WD (2010) A highly sensitive nonenzymatic glucose sensor based on CuO nanoparticles-modified carbon nanotube electrode. Biosens Bioelectron 25:1402-1407
    • (2010) Biosens Bioelectron , vol.25 , pp. 1402-1407
    • Jiang, L.C.1    Zhang, W.D.2
  • 23
    • 59849116773 scopus 로고    scopus 로고
    • Direct electrochemical response of glucose at nickel-doped diamond like carbon thin film electrodes
    • 10.1016/j.jelechem.2008.12.019 1:CAS:528:DC%2BD1MXhvFams74%3D
    • Yang GC, Liu E, Khun NW, Jiang SP (2009) Direct electrochemical response of glucose at nickel-doped diamond like carbon thin film electrodes. J Electroanal Chem 627:51-57
    • (2009) J Electroanal Chem , vol.627 , pp. 51-57
    • Yang, G.C.1    Liu, E.2    Khun, N.W.3    Jiang, S.P.4
  • 24
    • 0026519515 scopus 로고
    • Glucose oxidase: An ideal enzyme
    • 10.1016/0956-5663(92)87013-F 1:CAS:528:DyaK38XitlSnu78%3D
    • Wilson R, Turner APF (1992) Glucose oxidase: an ideal enzyme. Biosens Bioelectron 7:165-185
    • (1992) Biosens Bioelectron , vol.7 , pp. 165-185
    • Wilson, R.1    Turner, A.P.F.2
  • 25
    • 78651379494 scopus 로고    scopus 로고
    • An amperometric non-enzymatic glucose sensor by electrodepositing copper nanocubes onto vertically well-aligned multi-walled carbon nanotube arrays
    • 10.1016/j.bios.2010.06.014 1:CAS:528:DC%2BC3cXhtFGht77F
    • Yang J, Zhang WD, Gunasekaran S (2010) An amperometric non-enzymatic glucose sensor by electrodepositing copper nanocubes onto vertically well-aligned multi-walled carbon nanotube arrays. Biosens Bioelectron 26:279-284
    • (2010) Biosens Bioelectron , vol.26 , pp. 279-284
    • Yang, J.1    Zhang, W.D.2    Gunasekaran, S.3
  • 26
    • 37249014988 scopus 로고    scopus 로고
    • An improved sensitivity non-enzymatic glucose sensor based on a CuO nanowire modified Cu electrode
    • 10.1039/b712970j 1:CAS:528:DC%2BD2sXhsVehsrrF
    • Zhuang Z, Su X, Yuan H, Sun Q, Xiao D, Choi MMF (2008) An improved sensitivity non-enzymatic glucose sensor based on a CuO nanowire modified Cu electrode. Analyst 133:126-132
    • (2008) Analyst , vol.133 , pp. 126-132
    • Zhuang, Z.1    Su, X.2    Yuan, H.3    Sun, Q.4    Xiao, D.5    Choi, M.M.F.6
  • 27
    • 29944443113 scopus 로고    scopus 로고
    • Electrochemical non-enzymatic glucose sensors
    • 10.1016/j.aca.2005.05.080 1:CAS:528:DC%2BD28Xhs1ylsw%3D%3D
    • Park S, Boo H, Chung TD (2006) Electrochemical non-enzymatic glucose sensors. Anal Chim Acta 556:46-57
    • (2006) Anal Chim Acta , vol.556 , pp. 46-57
    • Park, S.1    Boo, H.2    Chung, T.D.3
  • 28
    • 23844551253 scopus 로고    scopus 로고
    • Non-enzymatic glucose detection free of ascorbic acid interference using nickel powder and nafion sol-gel dispersed renewable carbon ceramic electrode
    • 10.1016/j.elecom.2005.05.009 1:CAS:528:DC%2BD2MXot1WqtL4%3D
    • Salimi A, Roushani M (2005) Non-enzymatic glucose detection free of ascorbic acid interference using nickel powder and nafion sol-gel dispersed renewable carbon ceramic electrode. Electrochem Commun 7:879-887
    • (2005) Electrochem Commun , vol.7 , pp. 879-887
    • Salimi, A.1    Roushani, M.2
  • 29
    • 18744401668 scopus 로고    scopus 로고
    • Highly ordered platinum-nanotubule arrays for amperometric glucose sensing
    • 10.1002/adfm.200400321 1:CAS:528:DC%2BD2MXktlSktbg%3D
    • Yuan JH, Wang K, Xia XH (2005) Highly ordered platinum-nanotubule arrays for amperometric glucose sensing. Adv Funct Mater 15:803-809
    • (2005) Adv Funct Mater , vol.15 , pp. 803-809
    • Yuan, J.H.1    Wang, K.2    Xia, X.H.3
  • 30
    • 0037115595 scopus 로고    scopus 로고
    • Resonant Raman scattering studies of Fano-type interference in boron doped diamond
    • 10.1063/1.1524018 1:CAS:528:DC%2BD38XptFGhu7Y%3D
    • Wang YG, Lau SP, Tay BK, Zhang XH (2002) Resonant Raman scattering studies of Fano-type interference in boron doped diamond. J Appl Phys 92:7253-7256
    • (2002) J Appl Phys , vol.92 , pp. 7253-7256
    • Wang, Y.G.1    Lau, S.P.2    Tay, B.K.3    Zhang, X.H.4
  • 31
    • 1542288049 scopus 로고    scopus 로고
    • Non-destructive determination of the boron concentration of heavily doped metallic diamond thin films from Raman spectroscopy
    • 10.1016/j.diamond.2003.10.051 1:CAS:528:DC%2BD2cXhsFWktro%3D
    • Bernard M, Deneuville A, Muret P (2004) Non-destructive determination of the boron concentration of heavily doped metallic diamond thin films from Raman spectroscopy. Diam Relat Mater 13:282-286
    • (2004) Diam Relat Mater , vol.13 , pp. 282-286
    • Bernard, M.1    Deneuville, A.2    Muret, P.3
  • 32
    • 0033560039 scopus 로고    scopus 로고
    • Electrochemical oxidation of polyamines at diamond thin-film electrodes
    • 10.1021/ac980697v 1:CAS:528:DyaK1MXovF2rug%3D%3D
    • Koppang MD, Witek M, Blau J, Swain GM (1999) Electrochemical oxidation of polyamines at diamond thin-film electrodes. Anal Chem 71:1188-1195
    • (1999) Anal Chem , vol.71 , pp. 1188-1195
    • Koppang, M.D.1    Witek, M.2    Blau, J.3    Swain, G.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.