메뉴 건너뛰기




Volumn 20, Issue 4, 2013, Pages 1421-1427

Influence of temperature, moisture content and ageing on oil impregnated paper bushings insulation

Author keywords

aging; capacitance; dielectric losses; humidity; Insulators; oil insulation; paper insulation; power transformer; temperature

Indexed keywords

DIELECTRIC DISSIPATION FACTORS; DIFFERENT MOISTURE CONTENTS; INFLUENCING PARAMETERS; OIL IMPREGNATED PAPERS; OIL INSULATIONS; PAPER INSULATION; TEMPERATURE DEPENDENCE; TRANSFORMER FAILURE;

EID: 84881537985     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2013.6571464     Document Type: Article
Times cited : (60)

References (13)
  • 1
    • 84881524829 scopus 로고    scopus 로고
    • Transformers accessories
    • Paris, ref
    • P. V. Goosen, "Transformers accessories", CIGRE 1996, Paris, ref. 12-104.
    • (1996) CIGRE , pp. 12-104
    • Goosen, P.V.1
  • 3
    • 33749908771 scopus 로고    scopus 로고
    • Evaluation and identification of typical defects and failure modes in 110-750 kV bushings
    • V. V. Sokolov and B. V. Vanin, "Evaluation and identification of typical defects and failure modes in 110-750 kV bushings", 64th Int'l. Conf. Doble clients, 1997.
    • (1997) 64th int'L. Conf. Doble Clients
    • Sokolov, V.V.1    Vanin, B.V.2
  • 4
    • 0018698148 scopus 로고
    • Selective investigation of long-time-constant ranges of polarization by dc methods
    • E. Németh, "Selective investigation of long time constant ranges of polarization by DC methods" IEE 3rd Int'l. Conf. Dielectr. Materials Measurements Applications (DMMA), Birmigham, UK, pp. 203-206, 1979. (Pubitemid 10480593)
    • (1979) IEE Conference Publication , Issue.177 , pp. 203-206
    • Nemeth, E.1
  • 5
    • 84874276723 scopus 로고    scopus 로고
    • Ageing-condition assessment of generator transformer bushings by means of dielectric simulation models
    • Bali, Indonesia
    • M. H. Zink, V. Klipfel, F. Berger and A. Küchler, "Ageing-condition Assessment of Generator Transformer Bushings by means of Dielectric Simulation Models", IEEE Int'l. Conf. Condition Monitoring and Diagnosis (CMD), Bali, Indonesia, pp. 137-140, 2012.
    • (2012) IEEE int'L. Conf. Condition Monitoring and Diagnosis (CMD) , pp. 137-140
    • Zink, M.H.1    Klipfel, V.2    Berger, F.3    Küchler, A.4
  • 7
    • 84881527262 scopus 로고    scopus 로고
    • Influence of humidity on capacitance and dielectric dissipation factor of transformers bushings
    • Cavtat (in Croatian)
    • A. Mikulecky, "Influence of humidity on capacitance and dielectric dissipation factor of transformers bushings" 7th. Conf. Croatian CIGRE organization, Cavtat, A2-10, 2005. (in Croatian)
    • (2005) 7th. Conf. Croatian CIGRE Organization , vol.A2-10
    • Mikulecky, A.1
  • 8
    • 84881539060 scopus 로고    scopus 로고
    • Influence of moisture distribution in oil-paper insulation on its dielectric response in time domain
    • Ljubljana, T7-120, (CD)
    • J. Szymanski, A. Graczkowski and H. Moscicka-Grzesiak, "Influence of Moisture Distribution in Oil-Paper Insulation on its Dielectric Response in Time Domain", Int'l. Sympos. High Voltage Eng. (ISH), Ljubljana, T7-120, (CD), 2007.
    • (2007) Int'L. Sympos. High Voltage Eng. (ISH)
    • Szymanski, J.1    Graczkowski, A.2    Moscicka-Grzesiak, H.3
  • 10
    • 77954182733 scopus 로고    scopus 로고
    • Temperature distribution in resin impregnated paper insulation for transformer bushings
    • N. S. Jyothi, T. S. Ramu and M. Mandlik, "Temperature Distribution in Resin Impregnated Paper Insulation for Transformer Bushings", IEEE Trans. Dielectr. Electr. Insul., Vol. 17, No. 3, pp. 931-938, 2010.
    • (2010) IEEE Trans. Dielectr. Electr. Insul , vol.17 , Issue.3 , pp. 931-938
    • Jyothi, N.S.1    Ramu, T.S.2    Mandlik, M.3
  • 11
    • 84872123341 scopus 로고    scopus 로고
    • Analysis of dielectric response measurements for condition assessment of oil-paper transformer insulation
    • M. Koch and T. Prevost, "Analysis of Dielectric Response Measurements for Condition Assessment of Oil-Paper Transformer Insulation", IEEE Trans. Dielectr. Electr. Insul., Vol.19, No. 6, pp. 1908-1915, 2012.
    • (2012) IEEE Trans. Dielectr. Electr. Insul. , vol.19 , Issue.6 , pp. 1908-1915
    • Koch, M.1    Prevost, T.2
  • 12
    • 84862649874 scopus 로고    scopus 로고
    • Quantitative analysis of ageing condition of oil-paper insulation by frequency domain spectroscopy
    • R. Liao, J. Hao, G. Chen and L. Yang, "Quantitative Analysis of Ageing Condition of Oil-Paper Insulation by Frequency Domain Spectroscopy", IEEE Trans. Dielectr. Electr. Insul., Vol. 19, No. 3, pp. 821-830, 2012.
    • (2012) IEEE Trans. Dielectr. Electr. Insul , vol.19 , Issue.3 , pp. 821-830
    • Liao, R.1    Hao, J.2    Chen, G.3    Yang, L.4
  • 13
    • 84881489772 scopus 로고    scopus 로고
    • Bushing insulation diagnostics based on dielectric response
    • Crown Publications, South Africa
    • P. Verelius and M. Ohlen, "Bushing Insulation Diagnostics Based on Dielectric Response", Electricity + Control, pp. 50-59, Crown Publications, South Africa, 2011.
    • (2011) Electricity + Control , pp. 50-59
    • Verelius, P.1    Ohlen, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.