메뉴 건너뛰기




Volumn , Issue , 2013, Pages 145-149

Design of electronic blood pressure monitoring system based on mobile telemedicine system

Author keywords

Blood Pressure (BP); Non invasive; Pressure Senor; ZigBee

Indexed keywords

BLOOD-PRESSURE MONITORING; LOW-POWER CONSUMPTION; MOBILE TELEMEDICINE SYSTEM; MONITORING SYSTEM; NON-INVASIVE; PRESSURE SIGNAL; SENIOR CITIZENS; ZIGBEE WIRELESS TRANSMISSION;

EID: 84881521101     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICCME.2013.6548228     Document Type: Conference Paper
Times cited : (6)

References (7)
  • 1
    • 50949124538 scopus 로고    scopus 로고
    • Mobile and wireless technologies on sphygmomanometer and pulsometer for patients setting pacemaker and complicating with other cardiovascular disease
    • May 16-18
    • C. S. Wang, T. W. Wang, J. H. Lee, and C. W. Liu, "Mobile and Wireless Technologies on Sphygmomanometer and Pulsometer for Patients Setting Pacemaker and Complicating with Other Cardiovascular Disease", The 2nd International Conference on Bioinformatics and Biomedical Engineering, May 16-18, 2008, pp. 1347-1350.
    • (2008) The 2nd International Conference on Bioinformatics and Biomedical Engineering , pp. 1347-1350
    • Wang, C.S.1    Wang, T.W.2    Lee, J.H.3    Liu, C.W.4
  • 3
    • 38349008915 scopus 로고    scopus 로고
    • Comparative study on auscultatory and oscillometric methods of ambulatory blood pressure measurements in adult patients
    • Genc Yasemin, Altunkan Sekip, Kiline Oguzhan, Altunkan Erkan."Comparative study on auscultatory and oscillometric methods of ambulatory blood pressure measurements in adult patients", Blood Pressure Monitoring 2008
    • (2008) Blood Pressure Monitoring
    • Yasemin, G.1    Sekip, A.2    Oguzhan, K.3    Erkan, A.4
  • 4
    • 34548141910 scopus 로고    scopus 로고
    • Real-time health information acquisition and alarm system based on bluetooth and gprs communication technologies
    • Oct. 8-11
    • Y. Fang, X. Lu, and H. Li, "Real-time Health Information Acquisition and Alarm System Based on Bluetooth and GPRS Communication Technologies", IEEE International Conference on Systems, Man and Cybernetics, vol. 6, pp. 4717-4721, Oct. 8-11, 2006.
    • (2006) IEEE International Conference on Systems, Man and Cybernetics , vol.6 , pp. 4717-4721
    • Fang, Y.1    Lu, X.2    Li, H.3
  • 6
    • 57849156544 scopus 로고    scopus 로고
    • Development of wireless embedded system using zigbee protocol to avoid white gaussian noise and 50 hz power line noise in ecg and pressure blood signals
    • Konstantinos Kalovrektis, Theodore Ganetsos, Evaggelos Fountas, and Georgia Tzitzili, "Development of Wireless embedded system using ZigBee protocol to avoid white Gaussian noise and 50 Hz Power line noise in ECG and Pressure Blood signals", Panhellenic Conference on Informatics, 978-0-7695-3323-0/08,2008.
    • (2008) Panhellenic Conference on Informatics , pp. 9780-76953323008
    • Kalovrektis, K.1    Ganetsos, T.2    Fountas, E.3    Tzitzili, G.4
  • 7
    • 84869426186 scopus 로고    scopus 로고
    • Development of a noninvasive continuous blood pressure measurement and monitoring system
    • Electronics & Vision
    • Manirul Islam, Fida Hasan Rafi, AbuFarzan Mitul and Mohiuddin Ahmad, "Development of a Noninvasive Continuous Blood Pressure Measurement and Monitoring System", IEEE International Conference on Informatics, Electronics & Vision, 2012.
    • (2012) IEEE International Conference on Informatics
    • Islam, M.1    Hasan Rafi, F.2    Mitul, A.3    Ahmad, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.