메뉴 건너뛰기




Volumn 115, Issue 3, 2013, Pages 313-324

The gravitational distribution of ventilation-perfusion ratio is more uniform in prone than supine posture in the normal human lung

Author keywords

Arterial spin labeling; Gravity; Magnetic resonance imaging; Specific ventilation imaging; Ventilation perfusion ratio

Indexed keywords

ADULT; ALGORITHM; ARTERIAL SPIN LABELING; ARTICLE; BODY POSTURE; BREATHING MECHANICS; COMPARATIVE STUDY; ELECTROCARDIOGRAPHY; FEMALE; FUNCTIONAL RESIDUAL CAPACITY; GRAVITY; HUMAN; IMAGE PROCESSING; LUNG; LUNG CIRCULATION; LUNG VENTILATION PERFUSION RATIO; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PHYSIOLOGY; SPECIFIC VENTILATION IMAGING; STATISTICAL ANALYSIS; SUPINE POSITION; TIDAL VOLUME;

EID: 84881456457     PISSN: 87507587     EISSN: 15221601     Source Type: Journal    
DOI: 10.1152/japplphysiol.01531.2012     Document Type: Article
Times cited : (104)

References (55)
  • 1
    • 0034027855 scopus 로고    scopus 로고
    • The prone position eliminates compression of the lungs by the heart
    • Albert RK, Hubmayr RD. The prone position eliminates compression of the lungs by the heart. Am J Respir Crit Care Med 161: 1660-1665, 2000.
    • (2000) Am J Respir Crit Care Med , vol.161 , pp. 1660-1665
    • Albert, R.K.1    Hubmayr, R.D.2
  • 2
    • 0021280510 scopus 로고
    • Effect of posture on inter-regional distribution of pulmonary perfusion and V̇ A/Q̇ ratios in man
    • Amis TC, Jones HA, Hughes JM. Effect of posture on inter-regional distribution of pulmonary perfusion and V̇ A/Q̇ ratios in man. Respir Physiol 56: 169-182, 1984.
    • (1984) Respir Physiol , vol.56 , pp. 169-182
    • Amis, T.C.1    Jones, H.A.2    Hughes, J.M.3
  • 4
    • 16544381854 scopus 로고    scopus 로고
    • Imaging lung function using rapid dynamic acquisition of T1-maps during oxygen enhancement
    • Arnold JF, Fidler F, Wang T, Pracht ED, Schmidt M, Jakob PM. Imaging lung function using rapid dynamic acquisition of T1-maps during oxygen enhancement. MAGMA 16: 246-253, 2004.
    • (2004) Magma , vol.16 , pp. 246-253
    • Arnold, J.F.1    Fidler, F.2    Wang, T.3    Pracht, E.D.4    Schmidt, M.5    Jakob, P.M.6
  • 7
    • 84863312421 scopus 로고    scopus 로고
    • Assessing the validity of MRIbased measurements of pulmonary blood flow distribution with anatomically-realistic model of the pulmonary circulation
    • Burrowes KS, Buxton RB, Prisk GK. Assessing the validity of MRIbased measurements of pulmonary blood flow distribution with anatomically-realistic model of the pulmonary circulation. J Appl Physiol 113: 130-141, 2012.
    • (2012) J Appl Physiol , vol.113 , pp. 130-141
    • Burrowes, K.S.1    Buxton, R.B.2    Prisk, G.K.3
  • 9
    • 0019830523 scopus 로고
    • Further considerations in a theoretical description of gastransport in lung airways
    • Davidson M. Further considerations in a theoretical description of gastransport in lung airways. Bull Math Biol 43: 517-548, 1981.
    • (1981) Bull Math Biol , vol.43 , pp. 517-548
    • Davidson, M.1
  • 10
    • 0029907856 scopus 로고    scopus 로고
    • Noninvasive assessment of regional ventilation in the human lung using oxygenenhanced magnetic resonance imaging
    • Edelman RR, Hatabu H, Tadamura E, Li W, Prasad PV. Noninvasive assessment of regional ventilation in the human lung using oxygenenhanced magnetic resonance imaging. Nat Med 2: 1236-1239, 1996.
    • (1996) Nat Med , vol.2 , pp. 1236-1239
    • Edelman, R.R.1    Hatabu, H.2    Tadamura, E.3    Li, W.4    Prasad, P.V.5
  • 11
    • 0020536790 scopus 로고
    • Gas mixing within the acinus of the lung
    • Engel LA. Gas mixing within the acinus of the lung. J Appl Physiol 54: 609-618, 1983.
    • (1983) J Appl Physiol , vol.54 , pp. 609-618
    • Engel, L.A.1
  • 12
    • 0027418979 scopus 로고
    • Inhaled nitric oxide selectively reverses human hypoxic pulmonary vasoconstriction without causing systemic vasodilation
    • Frostell CG, Blomqvist H, Hedenstierna G, Lundberg J, Zapol WM. Inhaled nitric oxide selectively reverses human hypoxic pulmonary vasoconstriction without causing systemic vasodilation. Anesthesiology 78: 427-435, 1993.
    • (1993) Anesthesiology , vol.78 , pp. 427-435
    • Frostell, C.G.1    Blomqvist, H.2    Hedenstierna, G.3    Lundberg, J.4    Zapol, W.M.5
  • 13
    • 0014446473 scopus 로고
    • Measurements of capillary dimensions and blood volume in rapidly frozen lungs
    • Glazier JB, Hughes JM, Maloney JE, West JB. Measurements of capillary dimensions and blood volume in rapidly frozen lungs. J Appl Physiol 26: 65-76, 1969.
    • (1969) J Appl Physiol , vol.26 , pp. 65-76
    • Glazier, J.B.1    Hughes, J.M.2    Maloney, J.E.3    West, J.B.4
  • 14
    • 0014149867 scopus 로고
    • Vertical gradient of alveolar size in lungs of dogs frozen intact
    • Glazier JB, Hughes JM, Maloney JE, West JB. Vertical gradient of alveolar size in lungs of dogs frozen intact. J Appl Physiol 23: 694-705, 1967.
    • (1967) J Appl Physiol , vol.23 , pp. 694-705
    • Glazier, J.B.1    Hughes, J.M.2    Maloney, J.E.3    West, J.B.4
  • 15
    • 0006152074 scopus 로고    scopus 로고
    • Heterogeneity in the lung: Concepts and measures
    • edited by Hlastala MP and Robertson HT. New York: Dekker
    • Glenny RW. Heterogeneity in the lung: concepts and measures. In: Complexity in Structure and Function in the Lung, edited by Hlastala MP and Robertson HT. New York: Dekker, 1998, p. 571-609.
    • (1998) Complexity in Structure and Function in the Lung , pp. 571-609
    • Glenny, R.W.1
  • 16
    • 0033018875 scopus 로고    scopus 로고
    • Gravity is an important but secondary determinant of regional pulmonary blood flow in upright primates
    • Glenny RW, Bernard S, Robertson HT, Hlastala MP. Gravity is an important but secondary determinant of regional pulmonary blood flow in upright primates. J Appl Physiol 86: 623-632, 1999.
    • (1999) J Appl Physiol , vol.86 , pp. 623-632
    • Glenny, R.W.1    Bernard, S.2    Robertson, H.T.3    Hlastala, M.P.4
  • 17
    • 0033870304 scopus 로고    scopus 로고
    • Pulmonary blood flow remains fractal down to the level of gas exchange
    • Glenny RW, Bernard SL, Robertson HT. Pulmonary blood flow remains fractal down to the level of gas exchange. J Appl Physiol 89: 742-748, 2000.
    • (2000) J Appl Physiol , vol.89 , pp. 742-748
    • Glenny, R.W.1    Bernard, S.L.2    Robertson, H.T.3
  • 18
    • 79954623691 scopus 로고    scopus 로고
    • Spatial distribution of ventilation and perfusion: Mechanisms and regulation
    • New York: Wiley
    • Glenny RW, Robertson HT. Spatial distribution of ventilation and perfusion: mechanisms and regulation. In: Comprehensive Physiology. New York: Wiley, 2011.
    • (2011) Comprehensive Physiology
    • Glenny, R.W.1    Robertson, H.T.2
  • 19
    • 0023951406 scopus 로고
    • Morphometry of the human pulmonary acinus
    • Haefeli-Bleuer B, Weibel ER. Morphometry of the human pulmonary acinus. Anat Rec 220: 401-414, 1988.
    • (1988) Anat Rec , vol.220 , pp. 401-414
    • Haefeli-Bleuer, B.1    Weibel, E.R.2
  • 21
    • 72749120111 scopus 로고    scopus 로고
    • Characterizing pulmonary blood flow distribution measured using arterial spin labeling
    • Henderson AC, Prisk GK, Levin DL, Hopkins SR, Buxton RB. Characterizing pulmonary blood flow distribution measured using arterial spin labeling. NMR Biomed 22: 1025-1035, 2009.
    • (2009) NMR Biomed , vol.22 , pp. 1025-1035
    • Henderson, A.C.1    Prisk, G.K.2    Levin, D.L.3    Hopkins, S.R.4    Buxton, R.B.5
  • 22
    • 0022263771 scopus 로고
    • Effect of body orientation on regional lung expansion: A computed tomographic approach
    • Hoffman EA. Effect of body orientation on regional lung expansion: a computed tomographic approach. J Appl Physiol 59: 468-480, 1985.
    • (1985) J Appl Physiol , vol.59 , pp. 468-480
    • Hoffman, E.A.1
  • 26
    • 78649677882 scopus 로고    scopus 로고
    • Lung perfusion measured using magnetic resonance imaging: New tools for physiological insights into the pulmonary circulation
    • Hopkins SR, Prisk GK. Lung perfusion measured using magnetic resonance imaging: New tools for physiological insights into the pulmonary circulation. J Magn Reson Imaging 32: 1287-1301, 2010.
    • (2010) J Magn Reson Imaging , vol.32 , pp. 1287-1301
    • Hopkins, S.R.1    Prisk, G.K.2
  • 27
    • 0035100488 scopus 로고    scopus 로고
    • Pulmonary perfusion in supine and prone positions: An electron-beam computed tomography study
    • Jones AT, Hansell DM, Evans TW. Pulmonary perfusion in supine and prone positions: an electron-beam computed tomography study. J Appl Physiol 90: 1342-1348, 2001.
    • (2001) J Appl Physiol , vol.90 , pp. 1342-1348
    • Jones, A.T.1    Hansell, D.M.2    Evans, T.W.3
  • 29
    • 0013909095 scopus 로고
    • Regional distribution of ventilation and perfusion as a function of body position
    • Kaneko K, Milic-Emili J, Dolovich MB, Dawson A, Bates DV. Regional distribution of ventilation and perfusion as a function of body position. J Appl Physiol 21: 767-777, 1966.
    • (1966) J Appl Physiol , vol.21 , pp. 767-777
    • Kaneko, K.1    Milic-Emili, J.2    Dolovich, M.B.3    Dawson, A.4    Bates, D.V.5
  • 30
    • 0023678911 scopus 로고
    • The prone position in ARDS patients. A clinical study
    • Langer M, Mascheroni D, Marcolin R, Gattinoni L. The prone position in ARDS patients. A clinical study. Chest 94: 103-107, 1988.
    • (1988) Chest , vol.94 , pp. 103-107
    • Langer, M.1    Mascheroni, D.2    Marcolin, R.3    Gattinoni, L.4
  • 31
    • 34247847661 scopus 로고    scopus 로고
    • Effects of age on pulmonary perfusion heterogeneity measured by magnetic resonance imaging
    • Levin DL, Buxton RB, Spiess JP, Arai T, Balouch J, Hopkins SR. Effects of age on pulmonary perfusion heterogeneity measured by magnetic resonance imaging. J Appl Physiol 102: 2064-2070, 2007.
    • (2007) J Appl Physiol , vol.102 , pp. 2064-2070
    • Levin, D.L.1    Buxton, R.B.2    Spiess, J.P.3    Arai, T.4    Balouch, J.5    Hopkins, S.R.6
  • 32
    • 0032928766 scopus 로고    scopus 로고
    • MR perfusion imaging of pulmonary parenchyma using pulsed arterial spin labeling techniques: FAIRER and FAIR
    • Mai VM, Berr SS. MR perfusion imaging of pulmonary parenchyma using pulsed arterial spin labeling techniques: FAIRER and FAIR. J Magn Reson Imaging 9: 483-487, 1999.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 483-487
    • Mai, V.M.1    Berr, S.S.2
  • 34
    • 0029070410 scopus 로고
    • Magnitude and time course of acute hypoxic pulmonary vasoconstriction in man
    • Morrell NW, Nijran KS, Biggs T, Seed WA. Magnitude and time course of acute hypoxic pulmonary vasoconstriction in man. Respir Physiol 100: 271-281, 1995.
    • (1995) Respir Physiol , vol.100 , pp. 271-281
    • Morrell, N.W.1    Nijran, K.S.2    Biggs, T.3    Seed, W.A.4
  • 37
    • 0006083960 scopus 로고    scopus 로고
    • Pulmonary perfusion is more uniform in the prone than in the supine position: Scintigraphy in healthy humans
    • Nyren S, Mure M, Jacobsson H, Larsson SA, Lindahl SG. Pulmonary perfusion is more uniform in the prone than in the supine position: scintigraphy in healthy humans. J Appl Physiol 86: 1135-1141, 1999.
    • (1999) J Appl Physiol , vol.86 , pp. 1135-1141
    • Nyren, S.1    Mure, M.2    Jacobsson, H.3    Larsson, S.A.4    Lindahl, S.G.5
  • 38
    • 77649092978 scopus 로고    scopus 로고
    • Lung ventilation and perfusion in prone and supine postures with reference to anesthetized and mechanically ventilated healthy volunteers
    • Nyren S, Radell P, Lindahl SG, Mure M, Petersson J, Larsson SA, Jacobsson H, Sanchez-Crespo A. Lung ventilation and perfusion in prone and supine postures with reference to anesthetized and mechanically ventilated healthy volunteers. Anesthesiology 112: 682-687, 2010.
    • (2010) Anesthesiology , vol.112 , pp. 682-687
    • Nyren, S.1    Radell, P.2    Lindahl, S.G.3    Mure, M.4    Petersson, J.5    Larsson, S.A.6    Jacobsson, H.7    Sanchez-Crespo, A.8
  • 39
    • 0015819309 scopus 로고
    • Gas transport in the human lung
    • Paiva M. Gas transport in the human lung. J Appl Physiol 35: 401-410, 1973.
    • (1973) J Appl Physiol , vol.35 , pp. 401-410
    • Paiva, M.1
  • 40
    • 0036796403 scopus 로고    scopus 로고
    • Prone position in acute respiratory distress syndrome
    • Pelosi P, Brazzi L, Gattinoni L. Prone position in acute respiratory distress syndrome. Eur Respir J 20: 1017-1028, 2002.
    • (2002) Eur Respir J , vol.20 , pp. 1017-1028
    • Pelosi, P.1    Brazzi, L.2    Gattinoni, L.3
  • 43
    • 0028864392 scopus 로고
    • Pulmonary gas exchange and its determinants during sustained microgravity on Spacelabs SLS-1 and SLS-2
    • Prisk GK, Elliott AR, Guy HJ, Kosonen JM, West JB. Pulmonary gas exchange and its determinants during sustained microgravity on Spacelabs SLS-1 and SLS-2. J Appl Physiol 79: 1290-1298, 1995.
    • (1995) J Appl Physiol , vol.79 , pp. 1290-1298
    • Prisk, G.K.1    Elliott, A.R.2    Guy, H.J.3    Kosonen, J.M.4    West, J.B.5
  • 45
    • 84881465027 scopus 로고    scopus 로고
    • Imaging tools for investigation of human gas exchange
    • doi:10.1125/japplphysiol.00591.2013
    • Robertson HT. Imaging tools for investigation of human gas exchange. J Appl Physiol; doi:10.1125/japplphysiol.00591.2013
    • J Appl Physiol
    • Robertson, H.T.1
  • 48
    • 0035095912 scopus 로고    scopus 로고
    • Water proton MR properties of human blood at 1.5 Tesla: Magnetic susceptibility, T(1), T(2), T(2), and non-Lorentzian signal behavior
    • Spees WM, Yablonskiy DA, Oswood MC, Ackerman JJ. Water proton MR properties of human blood at 1.5 Tesla: magnetic susceptibility, T(1), T(2), T(2), and non-Lorentzian signal behavior. Magn Reson Med 45: 533-542, 2001.
    • (2001) Magn Reson Med , vol.45 , pp. 533-542
    • Spees, W.M.1    Yablonskiy, D.A.2    Oswood, M.C.3    Ackerman, J.J.4
  • 49
    • 69749088112 scopus 로고    scopus 로고
    • Supine and prone differences in regional lung density and pleural pressure gradients in the human lung with constant shape
    • Tawhai MH, Nash MP, Lin CL, Hoffman EA. Supine and prone differences in regional lung density and pleural pressure gradients in the human lung with constant shape. J Appl Physiol 107: 912-920, 2009.
    • (2009) J Appl Physiol , vol.107 , pp. 912-920
    • Tawhai, M.H.1    Nash, M.P.2    Lin, C.L.3    Hoffman, E.A.4
  • 51
    • 0030901730 scopus 로고    scopus 로고
    • Contributions of pulmonary perfusion and ventilation to heterogeneity in V̇ A/Q̇ measured by PET
    • Treppo S, Mijailovich SM, Venegas JG. Contributions of pulmonary perfusion and ventilation to heterogeneity in V̇ A/Q̇ measured by PET. J Appl Physiol 82: 1163-1176, 1997.
    • (1997) J Appl Physiol , vol.82 , pp. 1163-1176
    • Treppo, S.1    Mijailovich, S.M.2    Venegas, J.G.3
  • 52
    • 0016165629 scopus 로고
    • Continuous distributions of ventilation-perfusion ratios in normal subjects breathing air and 100 percent O2
    • Wagner P, Laravuso R, Uhl R, West J. Continuous distributions of ventilation-perfusion ratios in normal subjects breathing air and 100 percent O2. J Clin Invest 54: 54-68, 1974.
    • (1974) J Clin Invest , vol.54 , pp. 54-68
    • Wagner, P.1    Laravuso, R.2    Uhl, R.3    West, J.4
  • 53
    • 84866391706 scopus 로고    scopus 로고
    • Effect of regional lung inflation on ventilation heterogeneity at different length scales during mechanical ventilation of normal sheep lungs
    • Wellman TJ, Winkler T, Costa EL, Musch G, Harris RS, Venegas JG, Vidal Melo MF. Effect of regional lung inflation on ventilation heterogeneity at different length scales during mechanical ventilation of normal sheep lungs. J Appl Physiol 113: 947-957, 2012.
    • (2012) J Appl Physiol , vol.113 , pp. 947-957
    • Wellman, T.J.1    Winkler, T.2    Costa, E.L.3    Musch, G.4    Harris, R.S.5    Venegas, J.G.6    Vidal Melo, M.F.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.