메뉴 건너뛰기




Volumn 26, Issue 4, 2013, Pages 401-410

Impact of number of channels on RF shimming at 3T

Author keywords

Image nonuniformity; Parallel Transmission; RF shimming; SAR control

Indexed keywords


EID: 84881311183     PISSN: 09685243     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10334-012-0360-5     Document Type: Article
Times cited : (45)

References (24)
  • 1
    • 0035685766 scopus 로고    scopus 로고
    • Effect of RF coil excitation on field inhomogeneity at ultra high fields: A field optimized TEM resonatior
    • DOI 10.1016/S0730-725X(01)00404-0, PII S0730725X01004040
    • Ibrahim TS, Lee R, Baertlein BA, Abduljalil AM, Zhu H, Robitaille P-ML (2001) Effect of RF coil excitation on field inhomogeneity at ultra high fields: a field optimized TEM resonator. Magn Reson Imaging 19(10):1339-1347 (Pubitemid 34081298)
    • (2001) Magnetic Resonance Imaging , vol.19 , Issue.10 , pp. 1339-1347
    • Ibrahim, T.S.1    Lee, R.2    Baertlein, B.A.3    Abduljalil, A.M.4    Zhu, H.5    Robitaille, P.-M.L.6
  • 4
    • 77956096409 scopus 로고    scopus 로고
    • Dual-source parallel radiofrequency excitation body MR imaging compared with standard MR imaging at 3.0 T: Initial clinical experience 1
    • 20720078 10.1148/radiol.10092127
    • Willinek WA, Gieseke J, Kukuk GM, Nelles M, Konig R, Morakkabati-Spitz N, Traber F, Thomas D, Kuhl CK, Schild HH (2010) Dual-source parallel radiofrequency excitation body MR imaging compared with standard MR imaging at 3.0 T: initial clinical experience 1. Radiology 256(3):966-975
    • (2010) Radiology , vol.256 , Issue.3 , pp. 966-975
    • Willinek, W.A.1    Gieseke, J.2    Kukuk, G.M.3    Nelles, M.4    Konig, R.5    Morakkabati-Spitz, N.6    Traber, F.7    Thomas, D.8    Kuhl, C.K.9    Schild, H.H.10
  • 5
    • 79955000146 scopus 로고    scopus 로고
    • Focal liver lesions at 3.0 T: Lesion detectability and image quality with T2-weighted imaging by using conventional and dual-source parallel radiofrequency transmission
    • 21330565 10.1148/radiol.11101429
    • Kukuk GM, Gieseke J, Weber S, Hadizadeh DR, Nelles M, Traber F, Schild HH, Willinek WA (2011) Focal liver lesions at 3.0 T: lesion detectability and image quality with T2-weighted imaging by using conventional and dual-source parallel radiofrequency transmission. Radiology 259(2):421-428
    • (2011) Radiology , vol.259 , Issue.2 , pp. 421-428
    • Kukuk, G.M.1    Gieseke, J.2    Weber, S.3    Hadizadeh, D.R.4    Nelles, M.5    Traber, F.6    Schild, H.H.7    Willinek, W.A.8
  • 7
    • 41849141981 scopus 로고    scopus 로고
    • Magnitude least squares optimization for parallel radio frequency excitation design demonstrated at 7 tesla with eight channels
    • DOI 10.1002/mrm.21513
    • Setsompop K, Wald LL, Alagappan V, Gagoski BA, Adalsteinsson E (2008) Magnitude least squares optimization for parallel radio frequency excitation design demonstrated at 7 Tesla with eight channels. Magn Reson Med 59(4):908-915 (Pubitemid 351501959)
    • (2008) Magnetic Resonance in Medicine , vol.59 , Issue.4 , pp. 908-915
    • Setsompop, K.1    Wald, L.L.2    Alagappan, V.3    Gagoski, B.A.4    Adalsteinsson, E.5
  • 8
    • 33846078031 scopus 로고    scopus 로고
    • Actual flip-angle imaging in the pulsed steady state: A method for rapid three-dimensional mapping of the transmitted radiofrequency field
    • DOI 10.1002/mrm.21120
    • Yarnykh VL (2007) Actual flip-angle imaging in the pulsed steady state: a method for rapid three-dimensional mapping of the transmitted radiofrequency field. Magn Reson Med 57(1):192-200 (Pubitemid 46067949)
    • (2007) Magnetic Resonance in Medicine , vol.57 , Issue.1 , pp. 192-200
    • Yarnykh, V.L.1
  • 9
    • 60349112457 scopus 로고    scopus 로고
    • On the steady-state properties of actual flip angle imaging (AFI)
    • 19097210 10.1002/mrm.21592
    • Nehrke K (2009) On the steady-state properties of actual flip angle imaging (AFI). Magn Reson Med 61(1):84-92
    • (2009) Magn Reson Med , vol.61 , Issue.1 , pp. 84-92
    • Nehrke, K.1
  • 10
    • 79954603822 scopus 로고    scopus 로고
    • Slice profile correction for transmit sensitivity mapping using actual flip angle imaging
    • 21500266 10.1002/mrm.22739
    • Malik SJ, Kenny GD, Hajnal JV (2011) Slice profile correction for transmit sensitivity mapping using actual flip angle imaging. Magn Reson Med 65(5):1393-1399
    • (2011) Magn Reson Med , vol.65 , Issue.5 , pp. 1393-1399
    • Malik, S.J.1    Kenny, G.D.2    Hajnal, J.V.3
  • 11
    • 67049109394 scopus 로고    scopus 로고
    • B1+ interferometry for the calibration of RF transmitter arrays
    • 19353666 10.1002/mrm.21893
    • Brunner DO, Pruessmann KP (2009) B1+ interferometry for the calibration of RF transmitter arrays. Magn Reson Med 61(6):1480-1488
    • (2009) Magn Reson Med , vol.61 , Issue.6 , pp. 1480-1488
    • Brunner, D.O.1    Pruessmann, K.P.2
  • 12
    • 70349622977 scopus 로고    scopus 로고
    • Optimal linear combinations of array elements for B1 mapping
    • 19658161 10.1002/mrm.22068
    • Malik SJ, Larkman DJ, Hajnal JV (2009) Optimal linear combinations of array elements for B1 mapping. Magn Reson Med 62(4):902-909
    • (2009) Magn Reson Med , vol.62 , Issue.4 , pp. 902-909
    • Malik, S.J.1    Larkman, D.J.2    Hajnal, J.V.3
  • 13
    • 77649130914 scopus 로고    scopus 로고
    • Eigenmode analysis of transmit coil array for tailored B1 mapping
    • 20146236 10.1002/mrm.22239
    • Nehrke K, Boenert P (2010) Eigenmode analysis of transmit coil array for tailored B1 mapping. Magn Reson Med 63(3):754-764
    • (2010) Magn Reson Med , vol.63 , Issue.3 , pp. 754-764
    • Nehrke, K.1    Boenert, P.2
  • 14
    • 80054808213 scopus 로고    scopus 로고
    • Local specific absorption rate control for parallel transmission by virtual observation points
    • 21604294 10.1002/mrm.22927
    • Eichfelder G, Gebhardt M (2011) Local specific absorption rate control for parallel transmission by virtual observation points. Magn Reson Med 66(5):1468-1476
    • (2011) Magn Reson Med , vol.66 , Issue.5 , pp. 1468-1476
    • Eichfelder, G.1    Gebhardt, M.2
  • 16
    • 84867849878 scopus 로고    scopus 로고
    • A specific absorption rate prediction concept for parallel transmission MR
    • doi: 10.1002/mrm.24138
    • Graesslin I, Homann H, Biederer S, Börnert P, Nehrke K, Vernickel P, Mens G, Harvey P, Katscher U (2012) A specific absorption rate prediction concept for parallel transmission MR. Magn Reson Med. doi: 10.1002/mrm.24138
    • (2012) Magn Reson Med.
    • Graesslin I, H.1
  • 19
    • 0032129166 scopus 로고    scopus 로고
    • Standing-Wave and RF Penetration Artifacts Caused by Elliptic Geometry: An Electrodynamic Analysis of MRI
    • PII S0278006298085784
    • Sled JG, Pike GB (1998) Standing-wave and RF penetration artifacts caused by elliptic geometry: an electrodynamic analysis of MRI. Med Imaging IEEE Trans Med Imaging 17(4):653-662 (Pubitemid 128747720)
    • (1998) IEEE Transactions on Medical Imaging , vol.17 , Issue.4 , pp. 653-662
    • Sled, J.G.1    Bruce Pike, G.2
  • 20
    • 84985848260 scopus 로고
    • Echoes - How to generate, recognize, use or avoid them in MR-imaging sequences
    • 10.1002/cmr.1820030302
    • Hennig J (1991) Echoes - how to generate, recognize, use or avoid them in MR-imaging sequences. Concept Magn Reson 3(3):125-143
    • (1991) Concept Magn Reson , vol.3 , Issue.3 , pp. 125-143
    • Hennig, J.1
  • 21
    • 84876479410 scopus 로고    scopus 로고
    • Specific absorption rate intersubject variability in 7T parallel transmit MRI of the head
    • doi: 10.1002/mrm.24378
    • de Greef M, Ipek O, Raaijmakers AJE, Crezee J, van den Berg CAT (2012) Specific absorption rate intersubject variability in 7T parallel transmit MRI of the head. Magn Reson Med. doi: 10.1002/mrm.24378
    • (2012) Magn Reson Med.
    • De Greef, M.1    Ipek, O.2    Aje, R.3    Crezee, J.4    Van Den Berg Cat5
  • 22
    • 81355147745 scopus 로고    scopus 로고
    • Toward individualized SAR models and in vivo validation
    • 21630346 10.1002/mrm.22948 1:STN:280:DC%2BC3Mbps12quw%3D%3D
    • Homann H, Börnert P, Eggers H, Nehrke K, Dössel O, Graesslin I (2011) Toward individualized SAR models and in vivo validation. Magn Reson Med 66(6):1767-1776
    • (2011) Magn Reson Med , vol.66 , Issue.6 , pp. 1767-1776
    • Homann, H.1    Börnert, P.2    Eggers, H.3    Nehrke, K.4    Dössel, O.5    Graesslin, I.6
  • 23
    • 84864121005 scopus 로고    scopus 로고
    • Patient-individual local SAR determination: In vivo measurements and numerical validation
    • doi: 10.1002/mrm.23322
    • Voigt T, Homann H, Katscher U, Doessel O (2011) Patient-individual local SAR determination: In vivo measurements and numerical validation. Magn Reson Med. doi: 10.1002/mrm.23322
    • (2011) Magn Reson Med.
    • Voigt, T.1    Homann, H.2    Katscher, U.3    Doessel, O.4
  • 24
    • 84867890773 scopus 로고    scopus 로고
    • DREAM - A novel approach for robust, ultrafast, multislice B1 mapping
    • doi: 10.1002/mrm.24158
    • Nehrke K, Börnert P (2012) DREAM - a novel approach for robust, ultrafast, multislice B1 mapping. Magn Reson Med. doi: 10.1002/mrm.24158
    • (2012) Magn Reson Med.
    • Nehrke K, B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.