-
1
-
-
0031266937
-
Mini-implant for orthodontic anchorage
-
R. Kanomi Mini-implant for orthodontic anchorage JCO 36 11 1997 763 767
-
(1997)
JCO
, vol.36
, Issue.11
, pp. 763-767
-
-
Kanomi, R.1
-
3
-
-
0043253142
-
Mechanical principles in orthodontic force control
-
W. Proffit, H.W. Fields, Mosby Saint Louis
-
W. Proffit Mechanical principles in orthodontic force control W. Proffit, H.W. Fields, Contemporary orthodontics 1993 Mosby Saint Louis
-
(1993)
Contemporary Orthodontics
-
-
Proffit, W.1
-
4
-
-
22444434275
-
Load-related implant reaction of mini-implants used for orthodontic anchorage
-
A. Büchter, Wiechmann, S. Koerdt, H.P. Wiesmann, J. Piffko, and U. Meyer Load-related implant reaction of mini-implants used for orthodontic anchorage Clin. Oral Implants Res. 16 2005 473 479
-
(2005)
Clin. Oral Implants Res.
, vol.16
, pp. 473-479
-
-
Büchter, A.1
Wiechmann2
Koerdt, S.3
Wiesmann, H.P.4
Piffko, J.5
Meyer, U.6
-
5
-
-
0035432240
-
Bicortical titanium screws for critical orthodontic anchorage in the mandible: A preliminary report on clinical applications
-
J.W. Freudenthaler, R. Hass, and H.-P. Bantleon Bicortical titanium screws for critical orthodontic anchorage in the mandible: a preliminary report on clinical applications Clin. Oral Implants Res. 12 2001 358 363
-
(2001)
Clin. Oral Implants Res.
, vol.12
, pp. 358-363
-
-
Freudenthaler, J.W.1
Hass, R.2
Bantleon, H.-P.3
-
7
-
-
0025717802
-
A removal torque and histomorphometric study of commercially pure niobium and titanium implants in rabbit bone
-
C.B. Johansson, and T. Albrektsson A removal torque and histomorphometric study of commercially pure niobium and titanium implants in rabbit bone Clin. Oral Implants Res. 2 1991 24 29
-
(1991)
Clin. Oral Implants Res.
, vol.2
, pp. 24-29
-
-
Johansson, C.B.1
Albrektsson, T.2
-
8
-
-
0036185427
-
Biomechanical comparison of the sandblasted and acid-etched and machined and acid-etched titanium surface for dental implants
-
D. Li, S.J. Ferguson, T. Beutler, D.L. Cochran, C. Sittig, P.H. Hirt, and D. Buser Biomechanical comparison of the sandblasted and acid-etched and machined and acid-etched titanium surface for dental implants J. Biomed. Mater. Res. 60 2002 325 332
-
(2002)
J. Biomed. Mater. Res.
, vol.60
, pp. 325-332
-
-
Li, D.1
Ferguson, S.J.2
Beutler, T.3
Cochran, D.L.4
Sittig, C.5
Hirt, P.H.6
Buser, D.7
-
9
-
-
0020740361
-
Studies on the efficacy of implants as orthodontic anchorage
-
J.B. Gray, M.E. Steen, G.J. King, and A.E. Clark Studies on the efficacy of implants as orthodontic anchorage Am. J. Orthod. 83 1983 311 317
-
(1983)
Am. J. Orthod.
, vol.83
, pp. 311-317
-
-
Gray, J.B.1
Steen, M.E.2
King, G.J.3
Clark, A.E.4
-
10
-
-
0029268393
-
Markers of primary mineralization are correlated with bone-bonding ability of titanium or stainless steel in vivo
-
G. Braun, D. Kohavi, D. Amir, M. Luna, R. Caloss, and J. Sela Markers of primary mineralization are correlated with bone-bonding ability of titanium or stainless steel in vivo Clin. Oral Implants Res. 6 1995 1 13
-
(1995)
Clin. Oral Implants Res.
, vol.6
, pp. 1-13
-
-
Braun, G.1
Kohavi, D.2
Amir, D.3
Luna, M.4
Caloss, R.5
Sela, J.6
-
11
-
-
0034575060
-
The anchorage of titanium implants with different surface characteristics: An experimental study in rabbits
-
K. Gotfredsen, T. Berghlund, and J. Lindhe The anchorage of titanium implants with different surface characteristics: an experimental study in rabbits Clin. Implant Dent. Relat. Res. 2 2000 120 128
-
(2000)
Clin. Implant Dent. Relat. Res.
, vol.2
, pp. 120-128
-
-
Gotfredsen, K.1
Berghlund, T.2
Lindhe, J.3
-
12
-
-
0024005742
-
Osseointegrated oral implants. A Swedish multicenter study of 8139 consecutively inserted Nobel pharma implants
-
T. Albrektsson, E. Dahl, L. Enbom, S. Engevall, B. Engquist, and A.R. Eriksson Osseointegrated oral implants. A Swedish multicenter study of 8139 consecutively inserted Nobel pharma implants J. Periodontol. 59 1988 287 296
-
(1988)
J. Periodontol.
, vol.59
, pp. 287-296
-
-
Albrektsson, T.1
Dahl, E.2
Enbom, L.3
Engevall, S.4
Engquist, B.5
Eriksson, A.R.6
-
13
-
-
0023991091
-
Orthodontic force application to titanium endosseous implants
-
P.K. Turley, C. Kean, J. Schur, J. Stefanac, J. Gray, and J. Hennes Orthodontic force application to titanium endosseous implants Angle Orthod. 2 1988 151 162
-
(1988)
Angle Orthod.
, vol.2
, pp. 151-162
-
-
Turley, P.K.1
Kean, C.2
Schur, J.3
Stefanac, J.4
Gray, J.5
Hennes, J.6
-
14
-
-
0035344075
-
A clinical and histological evaluation of titanium mini-implants as anchor for orthodontic intrusion in the beagle dog
-
M. Ohmae, S. Saito, T. Morohashi, K. Seki, H. Qu, and R. Kanomi A clinical and histological evaluation of titanium mini-implants as anchor for orthodontic intrusion in the beagle dog Am. J. Orthod. Dentofacial Orthop. 119 2001 489 497
-
(2001)
Am. J. Orthod. Dentofacial Orthop.
, vol.119
, pp. 489-497
-
-
Ohmae, M.1
Saito, S.2
Morohashi, T.3
Seki, K.4
Qu, H.5
Kanomi, R.6
-
16
-
-
15244359466
-
Pull-out strength of monocortical screws placed in maxillae and mandibles of dogs
-
S.S. Huja, A.S. Litsky, F.M. Beck, K.A. Johnson, and P.E. Larsen Pull-out strength of monocortical screws placed in maxillae and mandibles of dogs Am. J. Orthod. Dentofacial Orthop. 127 2005 307 313
-
(2005)
Am. J. Orthod. Dentofacial Orthop.
, vol.127
, pp. 307-313
-
-
Huja, S.S.1
Litsky, A.S.2
Beck, F.M.3
Johnson, K.A.4
Larsen, P.E.5
-
17
-
-
0141921987
-
Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage
-
S. Miyawaki, I. Koyama, M. Inoue, K. Mashima, T. Sugahara, and T. Takano-Yamamoto Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage Am. J. Orthod. Dentofacial Orthop. 124 2003 373 378
-
(2003)
Am. J. Orthod. Dentofacial Orthop.
, vol.124
, pp. 373-378
-
-
Miyawaki, S.1
Koyama, I.2
Inoue, M.3
Mashima, K.4
Sugahara, T.5
Takano-Yamamoto, T.6
-
19
-
-
46249123758
-
Sequential bone healing of immediately loaded mini-implants
-
G. Serra, L.S. Morais, C.N. Elias, M.A. Meyers, L. Andrade, C. Müller, and M. Müller Sequential bone healing of immediately loaded mini-implants Am. J. Orthod. Dentofacial Orthop. 134 2008 44 52
-
(2008)
Am. J. Orthod. Dentofacial Orthop.
, vol.134
, pp. 44-52
-
-
Serra, G.1
Morais, L.S.2
Elias, C.N.3
Meyers, M.A.4
Andrade, L.5
Müller, C.6
Müller, M.7
-
20
-
-
0037334202
-
Element release from titanium devices used in oral and maxillofacial surgery
-
D. Zaffe, C. Bertoldi, and U. Consolo Element release from titanium devices used in oral and maxillofacial surgery Biomaterials 24 2003 1093 1099
-
(2003)
Biomaterials
, vol.24
, pp. 1093-1099
-
-
Zaffe, D.1
Bertoldi, C.2
Consolo, U.3
-
21
-
-
11844261435
-
Research progress on laser surface modification of titanium alloys
-
Y.S. Tian, C.Z. Chen, S.T. Li, and Q.H. Huo Research progress on laser surface modification of titanium alloys Appl. Surf. Sci. 242 2005 177 184
-
(2005)
Appl. Surf. Sci.
, vol.242
, pp. 177-184
-
-
Tian, Y.S.1
Chen, C.Z.2
Li, S.T.3
Huo, Q.H.4
-
22
-
-
0016814146
-
Pulmonary deposits of titanium dioxide in cytologic and lung biopsy specimens - Light and electron microscopic x-ray analysis
-
K. Maatta, and A.U. Arstila Pulmonary deposits of titanium dioxide in cytologic and lung biopsy specimens - light and electron microscopic x-ray analysis Lab. Invest. 33 3 1975 342 346
-
(1975)
Lab. Invest.
, vol.33
, Issue.3
, pp. 342-346
-
-
Maatta, K.1
Arstila, A.U.2
-
23
-
-
0026314753
-
Release of metal ions from dental implant materials in vivo: Determination of Al, Co, Cr, Mo, Ni, v and Ti in organTissues
-
S.J. Lugowski, D.C. Smith, A.D. McHugh, and J.C. Van Loon Release of metal ions from dental implant materials in vivo: determination of Al, Co, Cr, Mo, Ni, V and Ti in organTissues J. Biomed. Mater. Res. 25 1991 1443 1458
-
(1991)
J. Biomed. Mater. Res.
, vol.25
, pp. 1443-1458
-
-
Lugowski, S.J.1
Smith, D.C.2
McHugh, A.D.3
Van Loon, J.C.4
-
25
-
-
0027765325
-
Metal release from titanium fixtures during placement in the mandible: An experiment study
-
H. Schliephake, G. Reiss, R. Urban, F.W. Neukam, and S. Guckel Metal release from titanium fixtures during placement in the mandible: an experiment study Int. J. Oral Maxillofac. Implants 8 1993 502 511
-
(1993)
Int. J. Oral Maxillofac. Implants
, vol.8
, pp. 502-511
-
-
Schliephake, H.1
Reiss, G.2
Urban, R.3
Neukam, F.W.4
Guckel, S.5
-
27
-
-
51049085102
-
Nanostructured titanium for biomedical applications
-
R. Valiev, V. Semenova, H. Latysh, T. Rack, J. Lowe, L. Petruzelka, D. Dluhos, and J. Hrusak Nanostructured titanium for biomedical applications Adv. Eng. Mater. 8 2008 B15 B17
-
(2008)
Adv. Eng. Mater.
, vol.8
-
-
Valiev, R.1
Semenova, V.2
Latysh, H.3
Rack, T.4
Lowe, J.5
Petruzelka, L.6
Dluhos, D.7
Hrusak, J.8
-
28
-
-
0035840883
-
Advanced mechanical properties of pure titanium with ultrafine grained structure
-
A.V. Sergueeva, V.V. Stolyarov, R.Z. Valiev, and A.K. Mukherjee Advanced mechanical properties of pure titanium with ultrafine grained structure Scr. Mater. 45 2001 747 752
-
(2001)
Scr. Mater.
, vol.45
, pp. 747-752
-
-
Sergueeva, A.V.1
Stolyarov, V.V.2
Valiev, R.Z.3
Mukherjee, A.K.4
-
29
-
-
33645980317
-
Producing bulk ultrafine-grained materials by severe plastic deformation
-
R.Z. Valiev, Y. Estrin, Z. Horita, T.G. Langdon, M.J. Zehetbauer, and Y.T. Zhu Producing bulk ultrafine-grained materials by severe plastic deformation JOM 58 4 2006 33 39
-
(2006)
JOM
, vol.58
, Issue.4
, pp. 33-39
-
-
Valiev, R.Z.1
Estrin, Y.2
Horita, Z.3
Langdon, T.G.4
Zehetbauer, M.J.5
Zhu, Y.T.6
-
30
-
-
0033734384
-
Using equal-channel angular pressing for refining grain size
-
T.G. Langdon, Furukawa, M. Nemoto, and Z. Horita Using equal-channel angular pressing for refining grain size JOM 4 2000 30 33
-
(2000)
JOM
, vol.4
, pp. 30-33
-
-
Langdon, T.G.1
Furukawa2
Nemoto, M.3
Horita, Z.4
-
31
-
-
57849152398
-
Strength and fatigue properties enhancement in ultrafine-grained Ti produced by severe plastic deformation
-
10.1007/s (10853-008-2984-4 ISSN 0022-2461 (Print) (2209)1573-4803 (on-line))
-
I.P. Semenova, R.Z. Valiev, E.B. Yakushina, G.H. Salimgareeva, and T.C. Lowe Strength and fatigue properties enhancement in ultrafine-grained Ti produced by severe plastic deformation J. Mater. Sci. 2009 10.1007/s (10853-008-2984-4 ISSN 0022-2461 (Print) (2209)1573-4803 (on-line))
-
(2009)
J. Mater. Sci.
-
-
Semenova, I.P.1
Valiev, R.Z.2
Yakushina, E.B.3
Salimgareeva, G.H.4
Lowe, T.C.5
-
32
-
-
33645963243
-
Microstructure and properties of Ti rods produced by multi-step SPD
-
V.V. Latysh, G.H. Salimgareeva, I.P. Semenova, I.V. Kandarov, Y.T. Zhu, T.C. Lowe, and R.Z. Valiev Microstructure and properties of Ti rods produced by multi-step SPD Mater. Sci. Forum 503 2006 763 768
-
(2006)
Mater. Sci. Forum
, vol.503
, pp. 763-768
-
-
Latysh, V.V.1
Salimgareeva, G.H.2
Semenova, I.P.3
Kandarov, I.V.4
Zhu, Y.T.5
Lowe, T.C.6
Valiev, R.Z.7
-
33
-
-
0043267634
-
The effect on annealing on tensile deformation behavior of nanostructured SPD titanium
-
R.Z. Valiev, A.V. Sergueeva, and A.K. Mukherjee The effect on annealing on tensile deformation behavior of nanostructured SPD titanium Scr. Mater. 49 7 2003 669
-
(2003)
Scr. Mater.
, vol.49
, Issue.7
, pp. 669
-
-
Valiev, R.Z.1
Sergueeva, A.V.2
Mukherjee, A.K.3
-
34
-
-
63749109141
-
Systemic levels of metallic ions released from orthodontic mini-implants
-
L.S. Morais, G. Serra, E.F. Palermo, M.A. Meyers, and C. Elias Systemic levels of metallic ions released from orthodontic mini-implants Am. J. Orthod. Dentofacial Orthop. 135 4 2009 522 529
-
(2009)
Am. J. Orthod. Dentofacial Orthop.
, vol.135
, Issue.4
, pp. 522-529
-
-
Morais, L.S.1
Serra, G.2
Palermo, E.F.3
Meyers, M.A.4
Elias, C.5
-
35
-
-
34147158914
-
Titanium alloy mini-implant for orthodontic anchorage: Immediate loading and metal ion release
-
L.S. Morais, G. Serra, C.A. Muller, L.A. Andrade, E. Palermo, C.N. Elias, and M.A. Meyers Titanium alloy mini-implant for orthodontic anchorage: immediate loading and metal ion release Acta Biomater. 3 2007 331 339
-
(2007)
Acta Biomater.
, vol.3
, pp. 331-339
-
-
Morais, L.S.1
Serra, G.2
Muller, C.A.3
Andrade, L.A.4
Palermo, E.5
Elias, C.N.6
Meyers, M.A.7
-
36
-
-
72649105954
-
Sequential bone healing of immediately loaded mini-implants: Histomorphometric and fluorescense analysis
-
G. Serra, L.S. Morais, C.N. Elias, M.A. Meyers, L. Andrade, M. Muller, and C.A. Muller Sequential bone healing of immediately loaded mini-implants: histomorphometric and fluorescense analysis Am. J. Orthod. Dentofacial Orthop. 137 2010 80 90
-
(2010)
Am. J. Orthod. Dentofacial Orthop.
, vol.137
, pp. 80-90
-
-
Serra, G.1
Morais, L.S.2
Elias, C.N.3
Meyers, M.A.4
Andrade, L.5
Muller, M.6
Muller, C.A.7
-
37
-
-
2942613210
-
Comparison of metal release from various metallic biomaterials in vitro
-
Y. Okazaki, and E. Gotoh Comparison of metal release from various metallic biomaterials in vitro Biomaterials 26 1 2005 11 21
-
(2005)
Biomaterials
, vol.26
, Issue.1
, pp. 11-21
-
-
Okazaki, Y.1
Gotoh, E.2
-
38
-
-
9444243222
-
Metal ion release from metal implants
-
T. Hanawa Metal ion release from metal implants Mater. Sci. Eng. 24 6 2004 746 752
-
(2004)
Mater. Sci. Eng.
, vol.24
, Issue.6
, pp. 746-752
-
-
Hanawa, T.1
-
39
-
-
33644867475
-
Fast element mapping of titanium wear around implants of different surface structures
-
U. Meyer, M. Buhner, and A. Buchter Fast element mapping of titanium wear around implants of different surface structures Clin. Oral Implants Res. 17 2 2006 206 211
-
(2006)
Clin. Oral Implants Res.
, vol.17
, Issue.2
, pp. 206-211
-
-
Meyer, U.1
Buhner, M.2
Buchter, A.3
-
40
-
-
22844440204
-
The efficacy of deferiprone on tissues aluminum removal and copper, zinc, manganese level in rabbits
-
P. Liu, N. Yao, and S.D. Wu The efficacy of deferiprone on tissues aluminum removal and copper, zinc, manganese level in rabbits J. Inorg. Biochem. 99 8 2005 1733 1737
-
(2005)
J. Inorg. Biochem.
, vol.99
, Issue.8
, pp. 1733-1737
-
-
Liu, P.1
Yao, N.2
Wu, S.D.3
-
41
-
-
34249882779
-
Histomorphologic and histomorphometric evaluation of immediately and early loaded mini-implants for orthodontic anchorage
-
J.N. Freire, N.R. Silva, J.N. Gil, R.S. Magini, and P.G. Coelho Histomorphologic and histomorphometric evaluation of immediately and early loaded mini-implants for orthodontic anchorage Am. J. Orthod. Dentofacial Orthop. 131 2007 701 704
-
(2007)
Am. J. Orthod. Dentofacial Orthop.
, vol.131
, pp. 701-704
-
-
Freire, J.N.1
Silva, N.R.2
Gil, J.N.3
Magini, R.S.4
Coelho, P.G.5
-
42
-
-
23344450440
-
Peri-implant bone response to orthodontic loading: Part 1. A histomorphometric study of the effects of implant surface design
-
R. Oyonarte, R. Pilliar, D. Deporter, and D. Woodside Peri-implant bone response to orthodontic loading: Part 1. A histomorphometric study of the effects of implant surface design Am. J. Orthod. Dentofacial Orthop. 128 2005 173 181
-
(2005)
Am. J. Orthod. Dentofacial Orthop.
, vol.128
, pp. 173-181
-
-
Oyonarte, R.1
Pilliar, R.2
Deporter, D.3
Woodside, D.4
-
43
-
-
38349001355
-
Influence of surface characteristics on survival rates of mini-implants
-
K. Chaddad, A. Ferreira, N. Geurs, and M. Reddy Influence of surface characteristics on survival rates of mini-implants Angle Orthod. 78 1 2008 107 113
-
(2008)
Angle Orthod.
, vol.78
, Issue.1
, pp. 107-113
-
-
Chaddad, K.1
Ferreira, A.2
Geurs, N.3
Reddy, M.4
-
44
-
-
70349152991
-
Enhanced osteoblast response to an equal channel angular pressing-processed pure titanium substrate with microrough surface topography
-
J.-W. Park, Y.-J. Kim, C.H. Park, D.-H. Lee, Y.G. Ko, J.-H. Jang, and C.S. Lee Enhanced osteoblast response to an equal channel angular pressing-processed pure titanium substrate with microrough surface topography Acta Biomater. 5 2009 3272 3280
-
(2009)
Acta Biomater.
, vol.5
, pp. 3272-3280
-
-
Park, J.-W.1
Kim, Y.-J.2
Park, C.H.3
Lee, D.-H.4
Ko, Y.G.5
Jang, J.-H.6
Lee, C.S.7
|