메뉴 건너뛰기




Volumn 128, Issue 2, 2005, Pages 173-181

Peri-implant bone response to orthodontic loading: Part 1. a histomorphometric study of the effects of implant surface design

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL; ARTICLE; BONE REGENERATION; COMPARATIVE STUDY; DENTAL SURGERY; DENTURE; DOG; INSTRUMENTATION; JAW; MALE; MANDIBLE; MECHANICAL STRESS; PATHOLOGY; PATHOPHYSIOLOGY; PERIODONTAL DISEASE; PERIODONTIUM; PHYSIOLOGY; POROSITY; SCANNING ELECTRON MICROSCOPY; SURFACE PROPERTY; TOOTH IMPLANTATION; TOOTH PROSTHESIS;

EID: 23344450440     PISSN: 08895406     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ajodo.2004.02.023     Document Type: Article
Times cited : (38)

References (51)
  • 1
    • 0024846195 scopus 로고
    • Rigid endosseous implants for orthodontic and orthopedic anchorage
    • W.E. Roberts, K.J. Marshal, R.K. Gongloff Rigid endosseous implants for orthodontic and orthopedic anchorage Angle Orthod 59 1989 247 256
    • (1989) Angle Orthod , vol.59 , pp. 247-256
    • Roberts, W.E.1    Marshal, K.J.2    Gongloff, R.K.3
  • 2
    • 0442320346 scopus 로고    scopus 로고
    • Biomechanical basis of extraction space closure
    • R. Nanda Saunders Philadelphia
    • R. Nanda, A. Kuhlberg Biomechanical basis of extraction space closure R. Nanda Biomechanics in clinical orthodontics 1997 Saunders Philadelphia 156 187
    • (1997) Biomechanics in Clinical Orthodontics , pp. 156-187
    • Nanda, R.1    Kuhlberg, A.2
  • 3
    • 0032249071 scopus 로고    scopus 로고
    • Aspects of the use of endosseous palatal implants in orthodontic therapy
    • H. Wehrbein, B.R. Mertz Aspects of the use of endosseous palatal implants in orthodontic therapy J Aesthet Dent 10 1998 315 324
    • (1998) J Aesthet Dent , vol.10 , pp. 315-324
    • Wehrbein, H.1    Mertz, B.R.2
  • 4
    • 0031065978 scopus 로고    scopus 로고
    • Prosthodontic considerations when using implants for orthodontic anchorage
    • C.J. Goodacre, D.T. Brown, W.E. Roberts, M.T. Jeiroudi Prosthodontic considerations when using implants for orthodontic anchorage J Prosthet Dent 77 1997 162 170
    • (1997) J Prosthet Dent , vol.77 , pp. 162-170
    • Goodacre, C.J.1    Brown, D.T.2    Roberts, W.E.3    Jeiroudi, M.T.4
  • 5
    • 0033169907 scopus 로고    scopus 로고
    • Implant anchorage for the occlusal management of developmental defects in children: A preliminary report
    • P.J. Henry, S. Singer Implant anchorage for the occlusal management of developmental defects in children a preliminary report Pract Period Aesth Dent 11 1999 699 706
    • (1999) Pract Period Aesth Dent , vol.11 , pp. 699-706
    • Henry, P.J.1    Singer, S.2
  • 9
    • 0025679140 scopus 로고
    • Titanium implant anchorage in orthodontic treatment: An experimental investigation in monkeys
    • S. Linder-Aronson, A. Nordenram, G. Anneroth Titanium implant anchorage in orthodontic treatment an experimental investigation in monkeys Eur J Orthod 12 1990 414 419
    • (1990) Eur J Orthod , vol.12 , pp. 414-419
    • Linder-Aronson, S.1    Nordenram, A.2    Anneroth, G.3
  • 10
    • 0000603651 scopus 로고
    • Sutural response to orthopedic forces
    • D.S. Carlson S.A. Goldstein Center for Human Growth and Development; University of Michigan Ann Arbor
    • V.G. Kokich Sutural response to orthopedic forces D.S. Carlson S.A. Goldstein Bone biodynamics in orthodontic and orthopedic treatment. Craniofacial Growth Series. Vol 27 1992 Center for Human Growth and Development; University of Michigan Ann Arbor 173 188
    • (1992) Bone Biodynamics in Orthodontic and Orthopedic Treatment. Craniofacial Growth Series. Vol 27 , pp. 173-188
    • Kokich, V.G.1
  • 11
    • 0027613203 scopus 로고
    • Endosseous titanium implants during and after orthodontic load: An experimental study in dogs
    • H. Wehrbein, P. Diedrich Endosseous titanium implants during and after orthodontic load an experimental study in dogs Clin Oral Impl Res 4 1993 76 82
    • (1993) Clin Oral Impl Res , vol.4 , pp. 76-82
    • Wehrbein, H.1    Diedrich, P.2
  • 13
    • 0031107903 scopus 로고    scopus 로고
    • Orthodontic anchorage capacity of short titanium screw implants in the maxilla: An experimental study in the dog
    • H. Wehrbein, J. Glatzmaier, M. Yildrim Orthodontic anchorage capacity of short titanium screw implants in the maxilla an experimental study in the dog Clin Oral Impl Res 8 1997 131 141
    • (1997) Clin Oral Impl Res , vol.8 , pp. 131-141
    • Wehrbein, H.1    Glatzmaier, J.2    Yildrim, M.3
  • 15
    • 0033142077 scopus 로고    scopus 로고
    • Bone response to orthodontic loading of endosseous implants in the rabbit calvaria: Early continuous distalizing forces
    • Z. Majzoub, M. Finotti, F. Miotti, R. Giardino, N. Nicoli Aldini Bone response to orthodontic loading of endosseous implants in the rabbit calvaria early continuous distalizing forces Eur J Orthod 21 1999 223 230
    • (1999) Eur J Orthod , vol.21 , pp. 223-230
    • Majzoub, Z.1    Finotti, M.2    Miotti, F.3    Giardino, R.4    Nicoli Aldini, N.5
  • 18
    • 0035315830 scopus 로고    scopus 로고
    • Biological reactions of alveolar bone to orthodontic loading of oral implants
    • B. Melsen, N.P. Lang Biological reactions of alveolar bone to orthodontic loading of oral implants Clin Oral Impl Res 12 2001 144 152
    • (2001) Clin Oral Impl Res , vol.12 , pp. 144-152
    • Melsen, B.1    Lang, N.P.2
  • 19
    • 77956981059 scopus 로고
    • Osseointegrated titanium implants: A new approach in orthodontic treatment
    • J. Odman, U. Lekholm, T. Jemt, P.I. Branemark, B. Thilander Osseointegrated titanium implants a new approach in orthodontic treatment Eur J Orthod 10 1988 98 105
    • (1988) Eur J Orthod , vol.10 , pp. 98-105
    • Odman, J.1    Lekholm, U.2    Jemt, T.3    Branemark, P.I.4    Thilander, B.5
  • 20
    • 0024780254 scopus 로고
    • The use of Branemark system implants for orthodontic anchorage: Report of a case
    • N.B. Van Roekel The use of Branemark system implants for orthodontic anchorage report of a case Int J Oral Maxillofac Impl 4 1989 341 344
    • (1989) Int J Oral Maxillofac Impl , vol.4 , pp. 341-344
    • Van Roekel, N.B.1
  • 21
    • 0025333345 scopus 로고
    • Rigid osseous implant utilized as anchorage to protract molars and close an atrophic extraction site
    • W.E. Roberts, K.J. Marshal, P.G. Moszary Rigid osseous implant utilized as anchorage to protract molars and close an atrophic extraction site Angle Orthod 60 1990 135 152
    • (1990) Angle Orthod , vol.60 , pp. 135-152
    • Roberts, W.E.1    Marshal, K.J.2    Moszary, P.G.3
  • 22
    • 0026214384 scopus 로고
    • The use of titanium fixtures for intraoral anchorage to facilitate orthodontic tooth movement
    • K.W. Higuchi, J.M. Slack The use of titanium fixtures for intraoral anchorage to facilitate orthodontic tooth movement Int J Oral Maxillofac Impl 6 1991 338 344
    • (1991) Int J Oral Maxillofac Impl , vol.6 , pp. 338-344
    • Higuchi, K.W.1    Slack, J.M.2
  • 23
    • 0026212071 scopus 로고
    • The efficacy of two-stage titanium implants as orthodontic anchorage in the preprosthodontic correction of third molars in adults: A report of three cases
    • H.R. Haanaes, A. Stenvik, E.S. Beyer-Olson, S. Tryti, O. Raehn The efficacy of two-stage titanium implants as orthodontic anchorage in the preprosthodontic correction of third molars in adults a report of three cases Eur J Orthod 13 1991 287 296
    • (1991) Eur J Orthod , vol.13 , pp. 287-296
    • Haanaes, H.R.1    Stenvik, A.2    Beyer-Olson, E.S.3    Tryti, S.4    Raehn, O.5
  • 24
    • 0028455168 scopus 로고
    • Osseointegrated implants as orthodontic anchorage in the treatment of partially edentulous adult patients
    • J. Odman, U. Lekholm, T. Jemt, B. Thilander Osseointegrated implants as orthodontic anchorage in the treatment of partially edentulous adult patients Eur J Orthod 16 1994 187 201
    • (1994) Eur J Orthod , vol.16 , pp. 187-201
    • Odman, J.1    Lekholm, U.2    Jemt, T.3    Thilander, B.4
  • 25
    • 0027792854 scopus 로고
    • Clinical case report: An improved technique for using dental implants as orthodontic anchorage
    • H. Stean Clinical case report an improved technique for using dental implants as orthodontic anchorage J Oral Impl 19 1993 336 340
    • (1993) J Oral Impl , vol.19 , pp. 336-340
    • Stean, H.1
  • 27
    • 0028679347 scopus 로고
    • Rigid implant anchorage to close a mandibular first molar extraction site
    • W.E. Roberts, C.L. Nelson, C.J. Goodacre Rigid implant anchorage to close a mandibular first molar extraction site J Clin Orthod 28 1994 693 704
    • (1994) J Clin Orthod , vol.28 , pp. 693-704
    • Roberts, W.E.1    Nelson, C.L.2    Goodacre, C.J.3
  • 28
    • 0030345625 scopus 로고    scopus 로고
    • Rate of mesial translation of mandibular molars using implant-anchored mechanics
    • W.E. Roberts, G.R. Arbuckle, M. Analoui Rate of mesial translation of mandibular molars using implant-anchored mechanics Angle Orthod 66 1996 331 338
    • (1996) Angle Orthod , vol.66 , pp. 331-338
    • Roberts, W.E.1    Arbuckle, G.R.2    Analoui, M.3
  • 29
    • 0030154342 scopus 로고    scopus 로고
    • Managing complex orthodontic problems: The use of implants for anchorage
    • V.G. Kokich Managing complex orthodontic problems the use of implants for anchorage Semin Orthod 2 1996 153 160
    • (1996) Semin Orthod , vol.2 , pp. 153-160
    • Kokich, V.G.1
  • 31
    • 0030185766 scopus 로고    scopus 로고
    • Implants in the orthodontic and prosthetic rehabilitation of an adult patient: A case report
    • J. Fernandez-Valeron, J. Fernandez-Velazquez Implants in the orthodontic and prosthetic rehabilitation of an adult patient a case report Int J Oral Maxillofac Impl 11 1996 534 538
    • (1996) Int J Oral Maxillofac Impl , vol.11 , pp. 534-538
    • Fernandez-Valeron, J.1    Fernandez-Velazquez, J.2
  • 32
    • 0032241117 scopus 로고    scopus 로고
    • Occlusal rehabilitation using implants for orthodontic anchorage
    • G. Schneider, K. Simmons, R. Nason, D. Felton Occlusal rehabilitation using implants for orthodontic anchorage J Prosthodont 7 1998 232 236
    • (1998) J Prosthodont , vol.7 , pp. 232-236
    • Schneider, G.1    Simmons, K.2    Nason, R.3    Felton, D.4
  • 33
    • 0033227130 scopus 로고    scopus 로고
    • Use of osseointegrated implants in adult orthodontic treatment: A clinical report
    • C.J. Drago Use of osseointegrated implants in adult orthodontic treatment a clinical report J Prosthet Dent 82 1999 504 509
    • (1999) J Prosthet Dent , vol.82 , pp. 504-509
    • Drago, C.J.1
  • 35
    • 0033073482 scopus 로고    scopus 로고
    • Palatal bone support for orthodontic implant anchorage: A clinical and radiological study
    • H. Wehrbein, B.R. Mertz, P. Diedrich Palatal bone support for orthodontic implant anchorage a clinical and radiological study Eur J Orthod 21 1999 65 70
    • (1999) Eur J Orthod , vol.21 , pp. 65-70
    • Wehrbein, H.1    Mertz, B.R.2    Diedrich, P.3
  • 36
    • 0033255654 scopus 로고    scopus 로고
    • Palatal implant anchorage reinforcement of posterior teeth: A prospective study
    • H. Wehrbein, H. Feifel, P. Diedrich Palatal implant anchorage reinforcement of posterior teeth a prospective study Am J Orthod Dentofacial Orthop 116 1999 678 686
    • (1999) Am J Orthod Dentofacial Orthop , vol.116 , pp. 678-686
    • Wehrbein, H.1    Feifel, H.2    Diedrich, P.3
  • 37
    • 0032249955 scopus 로고    scopus 로고
    • Overview of surface variability of metallic endosseous dental implants: Textured and porous surface-structured designs
    • R.M. Pilliar Overview of surface variability of metallic endosseous dental implants textured and porous surface-structured designs Impl Dent 7 1998 305 314
    • (1998) Impl Dent , vol.7 , pp. 305-314
    • Pilliar, R.M.1
  • 39
    • 0035432240 scopus 로고    scopus 로고
    • Bicortical titanium screws for critical orthodontic anchorage in the mandible: A preliminary report on clinical applications
    • J.W. Freudenthaler, R. Haas, H.-P. Bantleon Bicortical titanium screws for critical orthodontic anchorage in the mandible a preliminary report on clinical applications Clin Oral Impl Res 12 2001 358 363
    • (2001) Clin Oral Impl Res , vol.12 , pp. 358-363
    • Freudenthaler, J.W.1    Haas, R.2    Bantleon, H.-P.3
  • 41
    • 0022764363 scopus 로고
    • A histological assessment of the initial healing response adjacent to porous-surfaced, titanium alloy dental implants in dogs
    • D.A. Deporter, P.A. Watson, R.M. Pilliar, A.H. Melcher, J. Winslow, T.P. Howley A histological assessment of the initial healing response adjacent to porous-surfaced, titanium alloy dental implants in dogs J Dent Res 65 1986 1064 1070
    • (1986) J Dent Res , vol.65 , pp. 1064-1070
    • Deporter, D.A.1    Watson, P.A.2    Pilliar, R.M.3    Melcher, A.H.4    Winslow, J.5    Howley, T.P.6
  • 42
    • 0030155422 scopus 로고    scopus 로고
    • Loss of osseointegration caused by occlusal load of oral implants: A clinical and radiographic study in monkeys
    • F. Isidor Loss of osseointegration caused by occlusal load of oral implants a clinical and radiographic study in monkeys Clin Oral Impl Res 7 1996 143 152
    • (1996) Clin Oral Impl Res , vol.7 , pp. 143-152
    • Isidor, F.1
  • 43
    • 0031061799 scopus 로고    scopus 로고
    • Histological evaluation of peri-implant bone at implants subjected to occlusal overload or plaque accumulation
    • F. Isidor Histological evaluation of peri-implant bone at implants subjected to occlusal overload or plaque accumulation Clin Oral Impl Res 8 1997 1 9
    • (1997) Clin Oral Impl Res , vol.8 , pp. 1-9
    • Isidor, F.1
  • 44
    • 0034181164 scopus 로고    scopus 로고
    • The influence of controlled occlusal overload on peri-implant tissue: Part 3. a histologic study in monkeys
    • T. Miyata, Y. Kobayashi, H. Araki, T. Ohto, K. Shin The influence of controlled occlusal overload on peri-implant tissue: part 3. A histologic study in monkeys Int J Oral Maxillofac Impl 15 2000 425 431
    • (2000) Int J Oral Maxillofac Impl , vol.15 , pp. 425-431
    • Miyata, T.1    Kobayashi, Y.2    Araki, H.3    Ohto, T.4    Shin, K.5
  • 45
    • 0028509555 scopus 로고
    • Predictable crestal bone remodeling around two porous-coated titanium alloy dental implant designs: A radiographic study in dogs
    • A. Al-Sayyed, D.A. Deporter, R.M. Pilliar, P.A. Watson, M. Pharoah, K. Berhane Predictable crestal bone remodeling around two porous-coated titanium alloy dental implant designs a radiographic study in dogs Clin Oral Impl Res 5 1994 131 141
    • (1994) Clin Oral Impl Res , vol.5 , pp. 131-141
    • Al-Sayyed, A.1    Deporter, D.A.2    Pilliar, R.M.3    Watson, P.A.4    Pharoah, M.5    Berhane, K.6
  • 46
    • 0030155399 scopus 로고    scopus 로고
    • The effect of subcrestal placement of the polished surface of ITI implants on marginal soft and hard tissues
    • C.H.F. Hammerle, U. Bragger, W. Burgin, N.P. Lang The effect of subcrestal placement of the polished surface of ITI implants on marginal soft and hard tissues Clin Oral Impl Res 7 1996 111 119
    • (1996) Clin Oral Impl Res , vol.7 , pp. 111-119
    • Hammerle, C.H.F.1    Bragger, U.2    Burgin, W.3    Lang, N.P.4
  • 47
    • 0032039790 scopus 로고    scopus 로고
    • Marginal bone levels at single tooth implants with a conical fixture design: The influence of surface macro- and microstructure
    • M.R. Norton Marginal bone levels at single tooth implants with a conical fixture design the influence of surface macro- and microstructure Clin Oral Impl Res 9 1998 91 99
    • (1998) Clin Oral Impl Res , vol.9 , pp. 91-99
    • Norton, M.R.1
  • 48
    • 0035375058 scopus 로고    scopus 로고
    • Bone reactions adjacent to titanium implants with different surface characteristics subjected to static load: II. a study in the dog
    • K. Gotfredsen, T. Berglund, J. Lindhe Bone reactions adjacent to titanium implants with different surface characteristics subjected to static load: II. A study in the dog Clin Oral Impl Res 12 2001 196 201
    • (2001) Clin Oral Impl Res , vol.12 , pp. 196-201
    • Gotfredsen, K.1    Berglund, T.2    Lindhe, J.3
  • 49
    • 84983299236 scopus 로고    scopus 로고
    • Implant surface design for development and maintenance of osseointegration
    • J.E. Ellingsen S.P. Lyngstadaas CRC Press LLC Boca Raton, Fla
    • R.M. Pilliar Implant surface design for development and maintenance of osseointegration J.E. Ellingsen S.P. Lyngstadaas Bio-implant interface improving biomaterials and tissue reactions 2003 CRC Press LLC Boca Raton, Fla 43 58
    • (2003) Bio-implant Interface: Improving Biomaterials and Tissue Reactions , pp. 43-58
    • Pilliar, R.M.1
  • 50
    • 0030147360 scopus 로고    scopus 로고
    • Factors affecting crestal bone loss with dental implants partially covered with a porous coating: A finite element analysis
    • H. Vaillancourt, R.M. Pilliar, D. McCammond Factors affecting crestal bone loss with dental implants partially covered with a porous coating a finite element analysis Int J Oral Maxillofac Impl 11 1996 351 359
    • (1996) Int J Oral Maxillofac Impl , vol.11 , pp. 351-359
    • Vaillancourt, H.1    Pilliar, R.M.2    McCammond, D.3
  • 51
    • 18044403181 scopus 로고    scopus 로고
    • The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: An animal experimental study
    • J. Duyck, H.J. Ronold, H. Van Oosterwick, I. Naert, J. Vander Sloten, J.E. Ellingsen The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants an animal experimental study Clin Oral Impl Res 12 2001 207 218
    • (2001) Clin Oral Impl Res , vol.12 , pp. 207-218
    • Duyck, J.1    Ronold, H.J.2    Van Oosterwick, H.3    Naert, I.4    Vander Sloten, J.5    Ellingsen, J.E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.