메뉴 건너뛰기




Volumn 82, Issue 9, 2013, Pages 1436-1443

Diagnostic value of color Doppler ultrasonography and MDCT angiography in complications of hemodialysis fistulas and grafts

Author keywords

CDUS; Digital subtraction angiography; Hemodialysis fistula; MDCT angiography

Indexed keywords

IOPROMIDE; POLITEF;

EID: 84881134502     PISSN: 0720048X     EISSN: 18727727     Source Type: Journal    
DOI: 10.1016/j.ejrad.2013.03.015     Document Type: Article
Times cited : (17)

References (23)
  • 1
    • 0041913917 scopus 로고    scopus 로고
    • Identifying vascular access complications among ESRD patients in Europe. A prospective, multicenter study
    • European Dialysis and Transplant Nurses Association/European Renal Care Association 66-8, 99
    • M.M. Elseviers, J.P. Van Waeleghem European Dialysis and Transplant Nurses Association/European Renal Care Association Identifying vascular access complications among ESRD patients in Europe. A prospective, multicenter study Nephrology News and Issues 17 2003 61 64 66-8, 99
    • (2003) Nephrology News and Issues , vol.17 , pp. 61-64
    • Elseviers, M.M.1    Van Waeleghem, J.P.2
  • 2
    • 0024562379 scopus 로고
    • Color Doppler sonography of hemodialysis vascular access: Comparison with angiography
    • W.D. Middleton, D.D. Picus, M.V. Marx, and G.L. Melson Color Doppler sonography of hemodialysis vascular access: comparison with angiography AJR 152 1989 633 639
    • (1989) AJR , vol.152 , pp. 633-639
    • Middleton, W.D.1    Picus, D.D.2    Marx, M.V.3    Melson, G.L.4
  • 3
    • 0027670411 scopus 로고
    • Duplex and color Doppler sonography of hemodialysis arteriovenous fistulas and grafts
    • D.E. Finlay, D.G. Longley, M.C. Foshager, and J.G. Letourneau Duplex and color Doppler sonography of hemodialysis arteriovenous fistulas and grafts RadioGraphics 13 1993 983 999
    • (1993) RadioGraphics , vol.13 , pp. 983-999
    • Finlay, D.E.1    Longley, D.G.2    Foshager, M.C.3    Letourneau, J.G.4
  • 4
    • 26944435198 scopus 로고    scopus 로고
    • Stenosis detection in failing hemodialysis access fistulas and grafts: Comparison of color Doppler ultrasonography, contrast-enhanced magnetic resonance angiography, and digital subtraction angiography
    • C. Doelman, L.E. Duijm, and Y.S. Liem Stenosis detection in failing hemodialysis access fistulas and grafts: comparison of color Doppler ultrasonography, contrast-enhanced magnetic resonance angiography, and digital subtraction angiography Journal of Vascular Surgery 42 2005 739 746
    • (2005) Journal of Vascular Surgery , vol.42 , pp. 739-746
    • Doelman, C.1    Duijm, L.E.2    Liem, Y.S.3
  • 5
    • 58149502886 scopus 로고    scopus 로고
    • Evaluation of failing hemodialysis fistulas with multidetector CT angiography: Comparison of different 3D planes
    • E. Karadeli, N.C. Tarhan, and E.M. Ulu Evaluation of failing hemodialysis fistulas with multidetector CT angiography: comparison of different 3D planes European Journal of Radiology 69 2009 184 192
    • (2009) European Journal of Radiology , vol.69 , pp. 184-192
    • Karadeli, E.1    Tarhan, N.C.2    Ulu, E.M.3
  • 6
    • 33644847448 scopus 로고    scopus 로고
    • MDCT angiography for evaluation of the complete vascular tree of hemodialysis fistulas
    • S.F. Ko, C.C. Huang, and S.H. Ng MDCT angiography for evaluation of the complete vascular tree of hemodialysis fistulas AJR 185 2005 1268 1274
    • (2005) AJR , vol.185 , pp. 1268-1274
    • Ko, S.F.1    Huang, C.C.2    Ng, S.H.3
  • 7
    • 33745246339 scopus 로고    scopus 로고
    • KDOQI clinical practice guidelines and clinical practice recommendations for 2006 updates: Hemodialysis adequacy, peritoneal dialysis adequacy and vascular access
    • National Kidney Foundation
    • National Kidney Foundation KDOQI clinical practice guidelines and clinical practice recommendations for 2006 updates: hemodialysis adequacy, peritoneal dialysis adequacy and vascular access American Journal of Kidney Diseases 48 2006 176 247
    • (2006) American Journal of Kidney Diseases , vol.48 , pp. 176-247
  • 8
    • 0037404810 scopus 로고    scopus 로고
    • The role of interventional radiology in management of patients with end-stage renal disease
    • Review
    • M. Surlan, and P. Popovic The role of interventional radiology in management of patients with end-stage renal disease European Journal of Radiology 46 2003 96 114 Review
    • (2003) European Journal of Radiology , vol.46 , pp. 96-114
    • Surlan, M.1    Popovic, P.2
  • 9
    • 0036784423 scopus 로고    scopus 로고
    • Gadolinium-enhanced digital subtraction angiography of hemodialysis fistulas: A diagnostic and therapeutic approach
    • A.F. Le Blanche, M. Tassart, J.F. Deux, J. Rossert, J.M. Bigot, and F. Boudghene Gadolinium-enhanced digital subtraction angiography of hemodialysis fistulas: a diagnostic and therapeutic approach AJR 179 2002 1023 1028
    • (2002) AJR , vol.179 , pp. 1023-1028
    • Le Blanche, A.F.1    Tassart, M.2    Deux, J.F.3    Rossert, J.4    Bigot, J.M.5    Boudghene, F.6
  • 10
    • 63849338830 scopus 로고    scopus 로고
    • Stenosis detection in native hemodialysis fistulas with MDCT angiography
    • S. Heye, G. Maleux, K. Claes, D. Kuypers, and R. Oyen Stenosis detection in native hemodialysis fistulas with MDCT angiography AJR 192 2009 1079 1084
    • (2009) AJR , vol.192 , pp. 1079-1084
    • Heye, S.1    Maleux, G.2    Claes, K.3    Kuypers, D.4    Oyen, R.5
  • 11
    • 20444380680 scopus 로고    scopus 로고
    • Colour Doppler ultrasound assessment of well-functioning mature arteriovenous fistulas for haemodialysis access
    • R. Pietura, M. Janczarek, and W. Zaluska Colour Doppler ultrasound assessment of well-functioning mature arteriovenous fistulas for haemodialysis access European Journal of Radiology 55 2005 113 119
    • (2005) European Journal of Radiology , vol.55 , pp. 113-119
    • Pietura, R.1    Janczarek, M.2    Zaluska, W.3
  • 12
    • 0031982271 scopus 로고    scopus 로고
    • Hemodialysis access stenosis: Early detection with color Doppler ultrasound
    • R.A. Older, T.A. Gizienski, M.J. Wilkowski, J.F. Angle, and D.A. Cote Hemodialysis access stenosis: early detection with color Doppler ultrasound Radiology 207 1998 161 164
    • (1998) Radiology , vol.207 , pp. 161-164
    • Older, R.A.1    Gizienski, T.A.2    Wilkowski, M.J.3    Angle, J.F.4    Cote, D.A.5
  • 13
    • 0031782772 scopus 로고    scopus 로고
    • Hemodialysis access graft stenosis: US detection
    • M.L. Robbin, R.F. Oser, and M. Allon Hemodialysis access graft stenosis: US detection Radiology 208 1998 655 661
    • (1998) Radiology , vol.208 , pp. 655-661
    • Robbin, M.L.1    Oser, R.F.2    Allon, M.3
  • 16
    • 33745575372 scopus 로고    scopus 로고
    • Time-resolved 3D MR angiography with parallel imaging for evaluation of hemodialysis fistulas and grafts: Initial experience
    • J. Zhang, E.M. Hecht, T. Maldonado, and V.S. Lee Time-resolved 3D MR angiography with parallel imaging for evaluation of hemodialysis fistulas and grafts: initial experience AJR 186 2006 1436 1442
    • (2006) AJR , vol.186 , pp. 1436-1442
    • Zhang, J.1    Hecht, E.M.2    Maldonado, T.3    Lee, V.S.4
  • 17
    • 77749252417 scopus 로고    scopus 로고
    • Arteriovenous fistula and graft evaluation in hemodialysis patients using MDCT: A primer
    • M.C. Chen, W.L. Tsai, and I.C. Tsai Arteriovenous fistula and graft evaluation in hemodialysis patients using MDCT: a primer AJR 194 2010 838 847
    • (2010) AJR , vol.194 , pp. 838-847
    • Chen, M.C.1    Tsai, W.L.2    Tsai, I.C.3
  • 20
    • 10644265258 scopus 로고    scopus 로고
    • Stenosis detection with MR angiography and digital subtraction angiography in dysfunctional hemodialysis access fistulas and grafts
    • C.L. Froger, L.E. Duijm, and Y.S. Liem Stenosis detection with MR angiography and digital subtraction angiography in dysfunctional hemodialysis access fistulas and grafts Radiology 234 2005 284 291
    • (2005) Radiology , vol.234 , pp. 284-291
    • Froger, C.L.1    Duijm, L.E.2    Liem, Y.S.3
  • 21
    • 1042268902 scopus 로고    scopus 로고
    • Stenosis and thrombosis in haemodialysis fistulae and grafts: The surgeon's point of view
    • V. Mickley Stenosis and thrombosis in haemodialysis fistulae and grafts: the surgeon's point of view Nephrology, Dialysis, Transplantation 19 2004 309 311
    • (2004) Nephrology, Dialysis, Transplantation , vol.19 , pp. 309-311
    • Mickley, V.1
  • 22
    • 77950480102 scopus 로고    scopus 로고
    • Colour duplex ultrasound accurately identifies focal stenoses in dysfunctional autogenous arteriovenous fistulae
    • A.P. Chandra, D. Dimascio, S. Gruenewald, B. Nankivell, R.D. Allen, and J. Swinnen Colour duplex ultrasound accurately identifies focal stenoses in dysfunctional autogenous arteriovenous fistulae Nephrology (Carlton) 15 2010 300 306
    • (2010) Nephrology (Carlton) , vol.15 , pp. 300-306
    • Chandra, A.P.1    Dimascio, D.2    Gruenewald, S.3    Nankivell, B.4    Allen, R.D.5    Swinnen, J.6
  • 23
    • 84856342090 scopus 로고    scopus 로고
    • Contrast enhanced ultrasound of the lower limb deep venous system: A technical feasibility study. Technical innovation
    • V. Spiss, A. Loizides, M. Plaikner, S. Ostermann, S. Peer, and H. Gruber Contrast enhanced ultrasound of the lower limb deep venous system: a technical feasibility study. Technical innovation Medical Ultrasonography 13 2011 267 271
    • (2011) Medical Ultrasonography , vol.13 , pp. 267-271
    • Spiss, V.1    Loizides, A.2    Plaikner, M.3    Ostermann, S.4    Peer, S.5    Gruber, H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.