Volumn 51, Issue , 2013, Pages 1-12

Voltammetric determination of mercury(II)

Author keywords

Chemically modified electrode; Electroanalysis; Electrochemical; Electrode surface; Mercury(II); Monitoring; Nanomaterial; Stripping voltammetry; Voltammetric determination; Working electrode

Indexed keywords

ELECTROCHEMICAL ELECTRODES; MONITORING; NANOSTRUCTURED MATERIALS; VOLTAMMETRY;

EID: 84881128969     PISSN: 01659936     EISSN: 18793142     Source Type: Journal    
DOI: 10.1016/j.trac.2013.05.010     Document Type: Review
Times cited : (123)

References (80)
  • 2
    • 65249155320 scopus 로고    scopus 로고
    • Projections of global mercury emissions in 2050
    • Streets D.G., Zhang Q., Wu Y. Projections of global mercury emissions in 2050. Environ. Sci. Technol. 2009, 43:2983-2988.
    • (2009) Environ. Sci. Technol. , vol.43 , pp. 2983-2988
    • Streets, D.G.1    Zhang, Q.2    Wu, Y.3
  • 3
    • 77951630440 scopus 로고    scopus 로고
    • Methods for the determination and speciation of mercury in natural waters-A review
    • Leopold K., Foulkes M., Worsfold P. Methods for the determination and speciation of mercury in natural waters-A review. Anal. Chim. Acta 2010, 663:127-138.
    • (2010) Anal. Chim. Acta , vol.663 , pp. 127-138
    • Leopold, K.1    Foulkes, M.2    Worsfold, P.3
  • 4
    • 79955921205 scopus 로고    scopus 로고
    • Recent trends in macro-, micro-, and nanomaterial-based tools and strategies for heavy-metal detection
    • Aragay G., Pons J., Merkoçi A. Recent trends in macro-, micro-, and nanomaterial-based tools and strategies for heavy-metal detection. Chem. Rev. 2011, 111:3433-3458.
    • (2011) Chem. Rev. , vol.111 , pp. 3433-3458
    • Aragay, G.1    Pons, J.2    Merkoçi, A.3
  • 5
    • 84859131430 scopus 로고    scopus 로고
    • Fluorescent and colorimetric sensors for detection of lead, cadmium, and mercury ions
    • Kim H.N., Ren W.X., Kim J.S., Yoon J. Fluorescent and colorimetric sensors for detection of lead, cadmium, and mercury ions. Chem. Soc. Rev. 2012, 41:3210-3244.
    • (2012) Chem. Soc. Rev. , vol.41 , pp. 3210-3244
    • Kim, H.N.1    Ren, W.X.2    Kim, J.S.3    Yoon, J.4
  • 6
    • 79951658282 scopus 로고    scopus 로고
    • Gold nanoparticle probes for the detection of mercury, lead and copper ions
    • Lin Y.-W., Huang C.-C., Chang H.-T. Gold nanoparticle probes for the detection of mercury, lead and copper ions. Analyst 2011, 136:863-871.
    • (2011) Analyst , vol.136 , pp. 863-871
    • Lin, Y.-W.1    Huang, C.-C.2    Chang, H.-T.3
  • 9
    • 78649335497 scopus 로고    scopus 로고
    • Recent developments in on-line electrochemical stripping analysis-An overview of the last 12 years
    • Economou A. Recent developments in on-line electrochemical stripping analysis-An overview of the last 12 years. Anal. Chim. Acta 2010, 683:38-51.
    • (2010) Anal. Chim. Acta , vol.683 , pp. 38-51
    • Economou, A.1
  • 13
    • 0003488529 scopus 로고    scopus 로고
    • Wiley-VCH Verlag GmbH & Co, KGaA
    • Wang J. Stripping Analysis 2007, Wiley-VCH Verlag GmbH & Co, KGaA.
    • (2007) Stripping Analysis
    • Wang, J.1
  • 14
    • 13944280561 scopus 로고    scopus 로고
    • Analytical techniques for trace element analysis: an overview, TrAC
    • Brown R.J.C., Milton M.J.T. Analytical techniques for trace element analysis: an overview, TrAC. Trends Anal. Chem. 2005, 24:266-274.
    • (2005) Trends Anal. Chem. , vol.24 , pp. 266-274
    • Brown, R.J.C.1    Milton, M.J.T.2
  • 16
    • 39649096060 scopus 로고    scopus 로고
    • Parameters affecting the determination of mercury by anodic stripping voltammetry using a gold electrode
    • Giacomino A., Abollino O., Malandrino M., Mentasti E. Parameters affecting the determination of mercury by anodic stripping voltammetry using a gold electrode. Talanta 2008, 75:266-273.
    • (2008) Talanta , vol.75 , pp. 266-273
    • Giacomino, A.1    Abollino, O.2    Malandrino, M.3    Mentasti, E.4
  • 17
    • 40849130891 scopus 로고    scopus 로고
    • Determination of mercury in table salt samples by on-line medium exchange anodic stripping voltammetry
    • Okçu F., Ertaş H., Ertaş F.N. Determination of mercury in table salt samples by on-line medium exchange anodic stripping voltammetry. Talanta 2008, 75:442-446.
    • (2008) Talanta , vol.75 , pp. 442-446
    • Okçu, F.1    Ertaş, H.2    Ertaş, F.N.3
  • 20
    • 33746263884 scopus 로고    scopus 로고
    • Voltammetric detection of mercury and copper in seawater using a gold microwire electrode
    • Salaün P., van den Berg C.M.G. Voltammetric detection of mercury and copper in seawater using a gold microwire electrode. Anal. Chem. 2006, 78:5052-5060.
    • (2006) Anal. Chem. , vol.78 , pp. 5052-5060
    • Salaün, P.1    van den Berg, C.M.G.2
  • 21
    • 79951684094 scopus 로고    scopus 로고
    • Determination of mercury in ambient water samples by anodic stripping voltammetry on screen-printed gold electrodes
    • Bernalte E., Sánchez C.M., Gil E.P. Determination of mercury in ambient water samples by anodic stripping voltammetry on screen-printed gold electrodes. Anal. Chim. Acta 2011, 689:60-64.
    • (2011) Anal. Chim. Acta , vol.689 , pp. 60-64
    • Bernalte, E.1    Sánchez, C.M.2    Gil, E.P.3
  • 22
    • 0032773259 scopus 로고    scopus 로고
    • Stripping analyses of mercury using gold electrodes: irreversible adsorption of mercury
    • Watson C.M., Dwyer D.J., Andle J.C., Bruce A.E., Bruce M.R.M. Stripping analyses of mercury using gold electrodes: irreversible adsorption of mercury. Anal. Chem. 1999, 71:3181-3186.
    • (1999) Anal. Chem. , vol.71 , pp. 3181-3186
    • Watson, C.M.1    Dwyer, D.J.2    Andle, J.C.3    Bruce, A.E.4    Bruce, M.R.M.5
  • 23
    • 57049127627 scopus 로고    scopus 로고
    • An optimized digestion method coupled to electrochemical sensor for the determination of Cd, Cu, Pb and Hg in fish by square wave anodic stripping voltammetry
    • Meucci V., Laschi S., Minunni M., Pretti C., Intorre L., Soldani G., Mascini M. An optimized digestion method coupled to electrochemical sensor for the determination of Cd, Cu, Pb and Hg in fish by square wave anodic stripping voltammetry. Talanta 2009, 77:1143-1148.
    • (2009) Talanta , vol.77 , pp. 1143-1148
    • Meucci, V.1    Laschi, S.2    Minunni, M.3    Pretti, C.4    Intorre, L.5    Soldani, G.6    Mascini, M.7
  • 24
    • 77951521387 scopus 로고    scopus 로고
    • Microfabricated on-chip integrated Au-Ag-Au three-electrode system for in situ mercury ion determination
    • Chen C., Zhang J., Du Y., Yang X., Wang E. Microfabricated on-chip integrated Au-Ag-Au three-electrode system for in situ mercury ion determination. Analyst 2010, 135:1010-1014.
    • (2010) Analyst , vol.135 , pp. 1010-1014
    • Chen, C.1    Zhang, J.2    Du, Y.3    Yang, X.4    Wang, E.5
  • 25
    • 80053560397 scopus 로고    scopus 로고
    • Stripping voltammetric determination of mercury(II) at antimony-coated carbon paste electrode
    • Ashrafi A.M., Vytřas K. Stripping voltammetric determination of mercury(II) at antimony-coated carbon paste electrode. Talanta 2011, 85:2700-2702.
    • (2011) Talanta , vol.85 , pp. 2700-2702
    • Ashrafi, A.M.1    Vytřas, K.2
  • 26
    • 77956580009 scopus 로고    scopus 로고
    • Metal nanoparticle modified boron doped diamond electrodes for use in electroanalysis
    • Toghill K.E., Compton R.G. Metal nanoparticle modified boron doped diamond electrodes for use in electroanalysis. Electroanalysis 2010, 22:1947-1956.
    • (2010) Electroanalysis , vol.22 , pp. 1947-1956
    • Toghill, K.E.1    Compton, R.G.2
  • 27
    • 0142165715 scopus 로고    scopus 로고
    • Screen-printed electrochemical sensors for monitoring metal pollutants, TrAC
    • Honeychurch K.C., Hart J.P. Screen-printed electrochemical sensors for monitoring metal pollutants, TrAC. Trends Anal. Chem. 2003, 22:456-469.
    • (2003) Trends Anal. Chem. , vol.22 , pp. 456-469
    • Honeychurch, K.C.1    Hart, J.P.2
  • 29
    • 71649085831 scopus 로고    scopus 로고
    • Langmuir-Blodgett film of p-tert-butylthiacalix [4] arene modified glassy carbon electrode as voltammetric sensor for the determination of Hg(II)
    • Wang F., Wei X., Wang C., Zhang S., Ye B. Langmuir-Blodgett film of p-tert-butylthiacalix [4] arene modified glassy carbon electrode as voltammetric sensor for the determination of Hg(II). Talanta 2010, 80:1198-1204.
    • (2010) Talanta , vol.80 , pp. 1198-1204
    • Wang, F.1    Wei, X.2    Wang, C.3    Zhang, S.4    Ye, B.5
  • 30
    • 78650256362 scopus 로고    scopus 로고
    • Thin functionalized films on cylindrical microelectrodes for electrochemical determination of Hg(II)
    • Fink L., Mandler D. Thin functionalized films on cylindrical microelectrodes for electrochemical determination of Hg(II). J. Electroanal. Chem. 2010, 649:153-158.
    • (2010) J. Electroanal. Chem. , vol.649 , pp. 153-158
    • Fink, L.1    Mandler, D.2
  • 31
    • 0037356974 scopus 로고    scopus 로고
    • Characterization of an EDTA bonded conducting polymer modified electrode: Its application for the simultaneous determination of heavy metal ions
    • Rahman M.A., Won M.-S., Shim Y.-B. Characterization of an EDTA bonded conducting polymer modified electrode: Its application for the simultaneous determination of heavy metal ions. Anal. Chem. 2003, 75:1123-1129.
    • (2003) Anal. Chem. , vol.75 , pp. 1123-1129
    • Rahman, M.A.1    Won, M.-S.2    Shim, Y.-B.3
  • 32
    • 38049087480 scopus 로고    scopus 로고
    • Voltammetric determination of mercury(II) at poly(3-hexylthiophene) film electrode. Effect of halide ions
    • Tamer U., Oymak T., Ertaş N. Voltammetric determination of mercury(II) at poly(3-hexylthiophene) film electrode. Effect of halide ions. Electroanalysis 2007, 19:2565-2570.
    • (2007) Electroanalysis , vol.19 , pp. 2565-2570
    • Tamer, U.1    Oymak, T.2    Ertaş, N.3
  • 33
    • 38849088664 scopus 로고    scopus 로고
    • Polyviologen modified glassy carbon electrode employed for anodic stripping voltammetric determination of mercury(II)
    • Cheng K.-C., Chen P.-Y. Polyviologen modified glassy carbon electrode employed for anodic stripping voltammetric determination of mercury(II). Electroanalysis 2008, 20:207-210.
    • (2008) Electroanalysis , vol.20 , pp. 207-210
    • Cheng, K.-C.1    Chen, P.-Y.2
  • 35
    • 84858622261 scopus 로고    scopus 로고
    • Molecular imprinting for selective chemical sensing of hazardous compounds and drugs of abuse, TrAC
    • Sharma P.S., D'Souza F., Kutner W. Molecular imprinting for selective chemical sensing of hazardous compounds and drugs of abuse, TrAC. Trends Anal. Chem. 2012, 34:59-77.
    • (2012) Trends Anal. Chem. , vol.34 , pp. 59-77
    • Sharma, P.S.1    D'Souza, F.2    Kutner, W.3
  • 37
    • 79951725580 scopus 로고    scopus 로고
    • 2+ selective imprinted polymer as a new modifying agent for the preparation of a novel highly selective and sensitive electrochemical sensor for the determination of ultratrace mercury ions
    • 2+ selective imprinted polymer as a new modifying agent for the preparation of a novel highly selective and sensitive electrochemical sensor for the determination of ultratrace mercury ions. Anal. Chim. Acta 2011, 689:52-59.
    • (2011) Anal. Chim. Acta , vol.689 , pp. 52-59
    • Alizadeh, T.1    Ganjali, M.R.2    Zare, M.3
  • 38
    • 78650179416 scopus 로고    scopus 로고
    • Stripping voltammetric detection of mercury(II) based on a surface ion imprinting strategy in electropolymerized microporous poly(2-mercaptobenzothiazole) films modified glassy carbon electrode
    • Fu X.-C., Chen X., Guo Z., Xie C.-G., Kong L.-T., Liu J.-H., Huang X.-J. Stripping voltammetric detection of mercury(II) based on a surface ion imprinting strategy in electropolymerized microporous poly(2-mercaptobenzothiazole) films modified glassy carbon electrode. Anal. Chim. Acta 2011, 685:21-28.
    • (2011) Anal. Chim. Acta , vol.685 , pp. 21-28
    • Fu, X.-C.1    Chen, X.2    Guo, Z.3    Xie, C.-G.4    Kong, L.-T.5    Liu, J.-H.6    Huang, X.-J.7
  • 39
    • 4544280307 scopus 로고    scopus 로고
    • Highly selective oligonucleotide-based sensor for mercury(II) in aqueous solutions
    • Ono A., Togashi H. Highly selective oligonucleotide-based sensor for mercury(II) in aqueous solutions. Angew. Chem. Int. Ed. 2004, 43:4300-4302.
    • (2004) Angew. Chem. Int. Ed. , vol.43 , pp. 4300-4302
    • Ono, A.1    Togashi, H.2
  • 40
    • 70349337804 scopus 로고    scopus 로고
    • A regenerative electrochemical sensor based on oligonucleotide for the selective determination of mercury(II)
    • Han D., Kim Y.-R., Oh J.-W., Kim T.H., Mahajan R.K., Kim J.S., Kim H. A regenerative electrochemical sensor based on oligonucleotide for the selective determination of mercury(II). Analyst 2009, 134:1857-1862.
    • (2009) Analyst , vol.134 , pp. 1857-1862
    • Han, D.1    Kim, Y.-R.2    Oh, J.-W.3    Kim, T.H.4    Mahajan, R.K.5    Kim, J.S.6    Kim, H.7
  • 41
    • 67650729740 scopus 로고    scopus 로고
    • Electrochemical sensor for mercury(II) based on conformational switch mediated by interstrand cooperative coordination
    • Liu S.-J., Nie H.-G., Jiang J.-H., Shen G.-L., Yu R.-Q. Electrochemical sensor for mercury(II) based on conformational switch mediated by interstrand cooperative coordination. Anal. Chem. 2009, 81:5724-5730.
    • (2009) Anal. Chem. , vol.81 , pp. 5724-5730
    • Liu, S.-J.1    Nie, H.-G.2    Jiang, J.-H.3    Shen, G.-L.4    Yu, R.-Q.5
  • 42
    • 71849091898 scopus 로고    scopus 로고
    • Ultrasensitive electrochemical sensor for mercury (II) based on target-induced structure-switching DNA
    • Wu D., Zhang Q., Chu X., Wang H., Shen G., Yu R. Ultrasensitive electrochemical sensor for mercury (II) based on target-induced structure-switching DNA. Biosens. Bioelectron. 2010, 25:1025-1031.
    • (2010) Biosens. Bioelectron. , vol.25 , pp. 1025-1031
    • Wu, D.1    Zhang, Q.2    Chu, X.3    Wang, H.4    Shen, G.5    Yu, R.6
  • 44
    • 76549110024 scopus 로고    scopus 로고
    • Polythymine oligonucleotide-modified gold electrode for voltammetric determination of mercury(II) in aqueous solution
    • Wu J., Li L., Shen B., Cheng G., He P., Fang Y. Polythymine oligonucleotide-modified gold electrode for voltammetric determination of mercury(II) in aqueous solution. Electroanalysis 2010, 22:479-482.
    • (2010) Electroanalysis , vol.22 , pp. 479-482
    • Wu, J.1    Li, L.2    Shen, B.3    Cheng, G.4    He, P.5    Fang, Y.6
  • 47
    • 38349037676 scopus 로고    scopus 로고
    • Determination of mercury by anodic stripping voltammetry with a gold nanoparticle-modified glassy carbon electrode
    • Abollino O., Giacomino A., Malandrino M., Piscionieri G., Mentasti E. Determination of mercury by anodic stripping voltammetry with a gold nanoparticle-modified glassy carbon electrode. Electroanalysis 2008, 20:75-83.
    • (2008) Electroanalysis , vol.20 , pp. 75-83
    • Abollino, O.1    Giacomino, A.2    Malandrino, M.3    Piscionieri, G.4    Mentasti, E.5
  • 48
    • 84859249187 scopus 로고    scopus 로고
    • Analytical applications of a nanoparticle-based sensor for the determination of mercury
    • Abollino O., Giacomino A., Ginepro M., Malandrino M., Zelano I. Analytical applications of a nanoparticle-based sensor for the determination of mercury. Electroanalysis 2012, 24:727-734.
    • (2012) Electroanalysis , vol.24 , pp. 727-734
    • Abollino, O.1    Giacomino, A.2    Ginepro, M.3    Malandrino, M.4    Zelano, I.5
  • 49
    • 79551545260 scopus 로고    scopus 로고
    • Construction of a carbon nanocomposite electrode based on amino acids functionalized gold nanoparticles for trace electrochemical detection of mercury
    • Safavi A., Farjami E. Construction of a carbon nanocomposite electrode based on amino acids functionalized gold nanoparticles for trace electrochemical detection of mercury. Anal. Chim. Acta 2011, 688:43-48.
    • (2011) Anal. Chim. Acta , vol.688 , pp. 43-48
    • Safavi, A.1    Farjami, E.2
  • 51
    • 70349742209 scopus 로고    scopus 로고
    • A novel electrochemical method to detect mercury (II) ions
    • Miao P., Liu L., Li Y., Li G. A novel electrochemical method to detect mercury (II) ions. Electrochem. Commun. 2009, 11:1904-1907.
    • (2009) Electrochem. Commun. , vol.11 , pp. 1904-1907
    • Miao, P.1    Liu, L.2    Li, Y.3    Li, G.4
  • 52
    • 70349123792 scopus 로고    scopus 로고
    • Highly sensitive electrochemical sensor for mercury(II) ions by using a mercury-specific oligonucleotide probe and gold nanoparticle-based amplification
    • Zhu Z., Su Y., Li J., Li D., Zhang J., Song S., Zhao Y., Li G., Fan C. Highly sensitive electrochemical sensor for mercury(II) ions by using a mercury-specific oligonucleotide probe and gold nanoparticle-based amplification. Anal. Chem. 2009, 81:7660-7666.
    • (2009) Anal. Chem. , vol.81 , pp. 7660-7666
    • Zhu, Z.1    Su, Y.2    Li, J.3    Li, D.4    Zhang, J.5    Song, S.6    Zhao, Y.7    Li, G.8    Fan, C.9
  • 53
    • 77956596581 scopus 로고    scopus 로고
    • Label-free electrochemical biosensor of mercury ions based on DNA strand displacement by thymine-Hg(II)-thymine complex
    • Liu X., Sun C., Wu H., Zhang Y., Jiang J., Shen G., Yu R. Label-free electrochemical biosensor of mercury ions based on DNA strand displacement by thymine-Hg(II)-thymine complex. Electroanalysis 2010, 22:2110-2116.
    • (2010) Electroanalysis , vol.22 , pp. 2110-2116
    • Liu, X.1    Sun, C.2    Wu, H.3    Zhang, Y.4    Jiang, J.5    Shen, G.6    Yu, R.7
  • 54
    • 46849113652 scopus 로고    scopus 로고
    • Gold nanoelectrode ensembles for the simultaneous electrochemical detection of ultratrace arsenic, mercury, and copper
    • Jena B.K., Raj C.R. Gold nanoelectrode ensembles for the simultaneous electrochemical detection of ultratrace arsenic, mercury, and copper. Anal. Chem. 2008, 80:4836-4844.
    • (2008) Anal. Chem. , vol.80 , pp. 4836-4844
    • Jena, B.K.1    Raj, C.R.2
  • 55
    • 79551510154 scopus 로고    scopus 로고
    • Composite PEDOT/Au nanoparticles modified electrodes for determination of mercury at trace levels by anodic stripping voltammetry
    • Giannetto M., Mori G., Terzi F., Zanardi C., Seeber R. Composite PEDOT/Au nanoparticles modified electrodes for determination of mercury at trace levels by anodic stripping voltammetry. Electroanalysis 2011, 23:456-462.
    • (2011) Electroanalysis , vol.23 , pp. 456-462
    • Giannetto, M.1    Mori, G.2    Terzi, F.3    Zanardi, C.4    Seeber, R.5
  • 56
    • 75649094540 scopus 로고    scopus 로고
    • Stripping voltammetric detection of mercury(II) based on a bimetallic Au-Pt inorganic-organic hybrid nanocomposite modified glassy carbon electrode
    • Gong J.M., Zhou T., Song D.D., Zhang L.Z., Hu X.L. Stripping voltammetric detection of mercury(II) based on a bimetallic Au-Pt inorganic-organic hybrid nanocomposite modified glassy carbon electrode. Anal. Chem. 2010, 82:567-573.
    • (2010) Anal. Chem. , vol.82 , pp. 567-573
    • Gong, J.M.1    Zhou, T.2    Song, D.D.3    Zhang, L.Z.4    Hu, X.L.5
  • 57
    • 84857804722 scopus 로고    scopus 로고
    • The new age of carbon nanotubes: an updated review of functionalized carbon nanotubes in electrochemical sensors
    • Gao C., Guo Z., Liu J.H., Huang X.J. The new age of carbon nanotubes: an updated review of functionalized carbon nanotubes in electrochemical sensors. Nanoscale 2012, 4:1948-1963.
    • (2012) Nanoscale , vol.4 , pp. 1948-1963
    • Gao, C.1    Guo, Z.2    Liu, J.H.3    Huang, X.J.4
  • 58
    • 80054020795 scopus 로고    scopus 로고
    • Applications of nanoscale carbon-based materials in heavy metal sensing and detection
    • Wanekaya A.K. Applications of nanoscale carbon-based materials in heavy metal sensing and detection. Analyst 2011, 136:4383-4391.
    • (2011) Analyst , vol.136 , pp. 4383-4391
    • Wanekaya, A.K.1
  • 61
    • 84867236979 scopus 로고    scopus 로고
    • Covalently modified multiwalled carbon nanotubes as a new voltammetric interface for the determination of mercury at picomolar level
    • Kempegowda R.G., Malingappa P. Covalently modified multiwalled carbon nanotubes as a new voltammetric interface for the determination of mercury at picomolar level. Electrochem. Commun. 2012, 25:83-86.
    • (2012) Electrochem. Commun. , vol.25 , pp. 83-86
    • Kempegowda, R.G.1    Malingappa, P.2
  • 62
    • 56249104091 scopus 로고    scopus 로고
    • Microwave-radiated synthesis of gold nanoparticles/carbon nanotubes composites and its application to voltammetric detection of trace mercury(II)
    • Xu H., Zeng L., Xing S., Shi G., Xian Y., Jin L. Microwave-radiated synthesis of gold nanoparticles/carbon nanotubes composites and its application to voltammetric detection of trace mercury(II). Electrochem. Commun. 2008, 10:1839-1843.
    • (2008) Electrochem. Commun. , vol.10 , pp. 1839-1843
    • Xu, H.1    Zeng, L.2    Xing, S.3    Shi, G.4    Xian, Y.5    Jin, L.6
  • 63
    • 84862804866 scopus 로고    scopus 로고
    • Electropolymerized surface ion imprinting films on a gold nanoparticles/single-wall carbon nanotube nanohybrids modified glassy carbon electrode for electrochemical detection of trace mercury(II) in water
    • Fu X.-C., Wu J., Nie L., Xie C.-G., Liu J.-H., Huang X.-J. Electropolymerized surface ion imprinting films on a gold nanoparticles/single-wall carbon nanotube nanohybrids modified glassy carbon electrode for electrochemical detection of trace mercury(II) in water. Anal. Chim. Acta 2012, 720:29-37.
    • (2012) Anal. Chim. Acta , vol.720 , pp. 29-37
    • Fu, X.-C.1    Wu, J.2    Nie, L.3    Xie, C.-G.4    Liu, J.-H.5    Huang, X.-J.6
  • 64
    • 84869192722 scopus 로고    scopus 로고
    • Graphene oxide: preparation, functionalization, and electrochemical applications
    • Chen D., Feng H., Li J. Graphene oxide: preparation, functionalization, and electrochemical applications. Chem. Rev. 2012, 112:6027-6053.
    • (2012) Chem. Rev. , vol.112 , pp. 6027-6053
    • Chen, D.1    Feng, H.2    Li, J.3
  • 65
    • 77953295630 scopus 로고    scopus 로고
    • Graphene based electrochemical sensors and biosensors: a review
    • Shao Y., Wang J., Wu H., Liu J., Aksay I.A., Lin Y. Graphene based electrochemical sensors and biosensors: a review. Electroanalysis 2010, 22:1027-1036.
    • (2010) Electroanalysis , vol.22 , pp. 1027-1036
    • Shao, Y.1    Wang, J.2    Wu, H.3    Liu, J.4    Aksay, I.A.5    Lin, Y.6
  • 67
    • 77954936502 scopus 로고    scopus 로고
    • Graphene-based materials in electrochemistry
    • Chen D., Tang L., Li J. Graphene-based materials in electrochemistry. Chem. Soc. Rev. 2010, 39:3157-3180.
    • (2010) Chem. Soc. Rev. , vol.39 , pp. 3157-3180
    • Chen, D.1    Tang, L.2    Li, J.3
  • 68
    • 77958054825 scopus 로고    scopus 로고
    • Graphene electrochemistry: an overview of potential applications
    • Brownson D.A.C., Banks C.E. Graphene electrochemistry: an overview of potential applications. Analyst 2010, 135:2768-2778.
    • (2010) Analyst , vol.135 , pp. 2768-2778
    • Brownson, D.A.C.1    Banks, C.E.2
  • 69
    • 77958487920 scopus 로고    scopus 로고
    • Monodispersed Au nanoparticles decorated graphene as an enhanced sensing platform for ultrasensitive stripping voltammetric detection of mercury(II)
    • Gong J., Zhou T., Song D., Zhang L. Monodispersed Au nanoparticles decorated graphene as an enhanced sensing platform for ultrasensitive stripping voltammetric detection of mercury(II). Sens. Actuators B: Chem. 2010, 150:491-497.
    • (2010) Sens. Actuators B: Chem. , vol.150 , pp. 491-497
    • Gong, J.1    Zhou, T.2    Song, D.3    Zhang, L.4
  • 70
    • 83455178800 scopus 로고    scopus 로고
    • 2+ by rational covalent functionalization of graphene oxide with cysteamine
    • 2+ by rational covalent functionalization of graphene oxide with cysteamine. Analyst 2012, 137:305-308.
    • (2012) Analyst , vol.137 , pp. 305-308
    • Zhou, H.1    Wang, X.2    Yu, P.3    Chen, X.4    Mao, L.5
  • 72
    • 84863013511 scopus 로고    scopus 로고
    • Selective adsorption toward toxic metal ions results in selective response: electrochemical studies on a polypyrrole/reduced graphene oxide nanocomposite
    • Zhao Z.-Q., Chen X., Yang Q., Liu J.-H., Huang X.-J. Selective adsorption toward toxic metal ions results in selective response: electrochemical studies on a polypyrrole/reduced graphene oxide nanocomposite. Chem. Commun. 2012, 48:2180-2182.
    • (2012) Chem. Commun. , vol.48 , pp. 2180-2182
    • Zhao, Z.-Q.1    Chen, X.2    Yang, Q.3    Liu, J.-H.4    Huang, X.-J.5
  • 73
    • 50849121122 scopus 로고    scopus 로고
    • Mesoporous silicate materials in sensing
    • Melde B.J., Johnson B.J., Charles P.T. Mesoporous silicate materials in sensing. Sensors 2008, 8:5202-5228.
    • (2008) Sensors , vol.8 , pp. 5202-5228
    • Melde, B.J.1    Johnson, B.J.2    Charles, P.T.3
  • 74
    • 39749133511 scopus 로고    scopus 로고
    • Evaluation of a carbon paste electrode modified with organofunctionalised SBA-15 nanostructured silica in the simultaneous determination of divalent lead, copper and mercury ions
    • Cesarino I., Marino G., Matos J.d.R., Cavalheiro É.T.G. Evaluation of a carbon paste electrode modified with organofunctionalised SBA-15 nanostructured silica in the simultaneous determination of divalent lead, copper and mercury ions. Talanta 2008, 75:15-21.
    • (2008) Talanta , vol.75 , pp. 15-21
    • Cesarino, I.1    Marino, G.2    Matos, J.3    Cavalheiro, É.T.G.4
  • 75
    • 55549093773 scopus 로고    scopus 로고
    • Thiol-functionalized silica thin film modified electrode in determination of mercury ions in natural water
    • Cesarino I., Cavalheiro É.T.G. Thiol-functionalized silica thin film modified electrode in determination of mercury ions in natural water. Electroanalysis 2008, 20:2301-2309.
    • (2008) Electroanalysis , vol.20 , pp. 2301-2309
    • Cesarino, I.1    Cavalheiro, É.T.G.2
  • 76
    • 72649094495 scopus 로고    scopus 로고
    • Simultaneous determination of cadmium, lead, copper and mercury ions using organofunctionalized SBA-15 nanostructured silica modified graphite-polyurethane composite electrode
    • Cesarino I., Cavalheiro E.T.G., Brett C.M.A. Simultaneous determination of cadmium, lead, copper and mercury ions using organofunctionalized SBA-15 nanostructured silica modified graphite-polyurethane composite electrode. Electroanalysis 2010, 22:61-68.
    • (2010) Electroanalysis , vol.22 , pp. 61-68
    • Cesarino, I.1    Cavalheiro, E.T.G.2    Brett, C.M.A.3
  • 78
    • 78650000232 scopus 로고    scopus 로고
    • Three-dimensional gold micro-/nanopore arrays containing 2-mercaptobenzothiazole molecular adapters allow sensitive and selective stripping voltammetric determination of trace mercury (II)
    • Fu X.C., Chen X., Guo Z., Kong L.T., Wang J., Liu J.H., Huang X.J. Three-dimensional gold micro-/nanopore arrays containing 2-mercaptobenzothiazole molecular adapters allow sensitive and selective stripping voltammetric determination of trace mercury (II). Electrochim. Acta 2010, 56:463-469.
    • (2010) Electrochim. Acta , vol.56 , pp. 463-469
    • Fu, X.C.1    Chen, X.2    Guo, Z.3    Kong, L.T.4    Wang, J.5    Liu, J.H.6    Huang, X.J.7
  • 79
    • 77951826108 scopus 로고    scopus 로고
    • Roses and raspberries
    • Murray R. Roses and raspberries. Anal. Chem. 2010, 82:3405.
    • (2010) Anal. Chem. , vol.82 , pp. 3405
    • Murray, R.1
  • 80
    • 63049103903 scopus 로고    scopus 로고
    • Preconcentration techniques for the determination of mercury species in natural waters, TrAC
    • Leopold K., Foulkes M., Worsfold P.J. Preconcentration techniques for the determination of mercury species in natural waters, TrAC. Trends Anal. Chem. 2009, 28:426-435.
    • (2009) Trends Anal. Chem. , vol.28 , pp. 426-435
    • Leopold, K.1    Foulkes, M.2    Worsfold, P.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.