메뉴 건너뛰기




Volumn 48, Issue 8, 2013, Pages 945-950

Nonvolatile salt-free stabilizer for the quantification of polar imipenem and cilastatin in human plasma using hydrophilic interaction chromatography/quadrupole mass spectrometry with contamination sensitive off-axis electrospray

Author keywords

cilastatin; hydrophilic interaction chromatography quadrupole mass spectrometry; imipenem; off axis electrospray; pharmacokinetics

Indexed keywords

BIOLOGICAL SAMPLES; CILASTATIN; ELECTROSPRAYS; HYDROPHILIC INTERACTION CHROMATOGRAPHY; IMIPENEM; MATRIX EFFECTS; PLASMA SAMPLES; SENSITIVE DETECTION;

EID: 84881103267     PISSN: 10765174     EISSN: 10969888     Source Type: Journal    
DOI: 10.1002/jms.3240     Document Type: Article
Times cited : (6)

References (11)
  • 2
    • 0021256979 scopus 로고
    • Determination of imipenem and cilastatin in serum by high-pressure liquid chromatography
    • C. M. Myers, J. L. Blumer,. Determination of imipenem and cilastatin in serum by high-pressure liquid chromatography. Antimicrob. Agents Chemother. 1984, 26, 78-81.
    • (1984) Antimicrob. Agents Chemother. , vol.26 , pp. 78-81
    • Myers, C.M.1    Blumer, J.L.2
  • 3
    • 0021205343 scopus 로고
    • Determination of imipenem (N-formimidoyl thienamycin) in human plasma and urine by high-performance liquid chromatography, comparison with microbiological methodology and stability
    • D. A. Gravallese, D. G. Musson, L. T. Pauliukonis, W. F. Bayne,. Determination of imipenem (N-formimidoyl thienamycin) in human plasma and urine by high-performance liquid chromatography, comparison with microbiological methodology and stability. J. Chromatogr. 1984, 310, 71-84.
    • (1984) J. Chromatogr. , vol.310 , pp. 71-84
    • Gravallese, D.A.1    Musson, D.G.2    Pauliukonis, L.T.3    Bayne, W.F.4
  • 4
    • 17444448605 scopus 로고    scopus 로고
    • Determination of imipenem in plasma by high-performance liquid chromatography for pharmacokinetic studies in patients
    • L. Garcia-Capdevila, C. Lõpez-Calull, C. Arroyo, M. A. Moral, M. A. Mangues, J. Bonal,. Determination of imipenem in plasma by high-performance liquid chromatography for pharmacokinetic studies in patients. J. Chromatogr. B 1997, 692, 127-132.
    • (1997) J. Chromatogr. B , vol.692 , pp. 127-132
    • Garcia-Capdevila, L.1    Lõpez-Calull, C.2    Arroyo, C.3    Moral, M.A.4    Mangues, M.A.5    Bonal, J.6
  • 5
    • 38349049052 scopus 로고    scopus 로고
    • Determination of imipenem and rifampicin in mouse plasma by high performance liquid chromatography-diode array detection
    • R. Fernández-Torres, M. A. Bello-Lõpez, M. Callejõn-Mochõn, J. C. Jiménez-Sánchez,. Determination of imipenem and rifampicin in mouse plasma by high performance liquid chromatography-diode array detection. Anal. Chim. Acta 2008, 608, 204-210.
    • (2008) Anal. Chim. Acta , vol.608 , pp. 204-210
    • Fernández-Torres, R.1    Bello-Lõpez, M.A.2    Callejõn- Mochõn, M.3    Jiménez-Sánchez, J.C.4
  • 6
    • 67650363828 scopus 로고    scopus 로고
    • Hydrophilic interaction chromatography/tandem mass spectrometry for the simultaneous determination of three polar non-structurally related compounds, imipenem, cilastatin and an investigational beta-lactamase inhibitor, MK-4698, in biological matrices
    • Y. Xu, W. Xie, C. M. Miller-Stein, E. J. Woolf,. Hydrophilic interaction chromatography/tandem mass spectrometry for the simultaneous determination of three polar non-structurally related compounds, imipenem, cilastatin and an investigational beta-lactamase inhibitor, MK-4698, in biological matrices. Rapid Commun. Mass Spectrom. 2009, 23, 2195-2205.
    • (2009) Rapid Commun. Mass Spectrom. , vol.23 , pp. 2195-2205
    • Xu, Y.1    Xie, W.2    Miller-Stein, C.M.3    Woolf, E.J.4
  • 7
    • 81255144050 scopus 로고    scopus 로고
    • Toward global metabolomics analysis with hydrophilic interaction liquid chromatography-mass spectrometry: Improved metabolite identification by retention time prediction
    • D. J. Creek, A. Jankevics, R. Breitling, D. G. Watson, M. P. Barrett, K. E. Burgess,. Toward global metabolomics analysis with hydrophilic interaction liquid chromatography-mass spectrometry: improved metabolite identification by retention time prediction. Anal. Chem. 2011, 83, 8703-8710.
    • (2011) Anal. Chem. , vol.83 , pp. 8703-8710
    • Creek, D.J.1    Jankevics, A.2    Breitling, R.3    Watson, D.G.4    Barrett, M.P.5    Burgess, K.E.6
  • 8
    • 70350507226 scopus 로고    scopus 로고
    • Electrospray: From ions in solution to ions in the gas phase, what we know now
    • P. Kebarle, U. H. Verkerk,. Electrospray: From ions in solution to ions in the gas phase, what we know now. Mass Spectrom. Rev. 2009, 28, 898-917.
    • (2009) Mass Spectrom. Rev. , vol.28 , pp. 898-917
    • Kebarle, P.1    Verkerk, U.H.2
  • 9
    • 84873702919 scopus 로고    scopus 로고
    • Conventional liquid chromatography/triple quadrupole mass spectrometry based metabolite identification and semi-quantitative estimation approach in the investigation of in vitro dabigatran etexilate metabolism
    • Z. Y. Hu, R. B. Parker, V. L. Herring, S. C. Laizure,. Conventional liquid chromatography/triple quadrupole mass spectrometry based metabolite identification and semi-quantitative estimation approach in the investigation of in vitro dabigatran etexilate metabolism. Anal. Bioanal. Chem. 2013, 405, 1695-1704.
    • (2013) Anal. Bioanal. Chem. , vol.405 , pp. 1695-1704
    • Hu, Z.Y.1    Parker, R.B.2    Herring, V.L.3    Laizure, S.C.4
  • 10
    • 84869082065 scopus 로고    scopus 로고
    • Simple and sensitive assay for quantification of oseltamivir and its active metabolite oseltamivir carboxylate in human plasma using high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry: Improved applicability to pharmacokinetic study
    • Z. Y. Hu, S. C. Laizure, B. Meibohm, V. L. Herring, R. B. Parker,. Simple and sensitive assay for quantification of oseltamivir and its active metabolite oseltamivir carboxylate in human plasma using high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry: improved applicability to pharmacokinetic study. J. Pharm. Biomed. Anal. 2013, 72, 245-250.
    • (2013) J. Pharm. Biomed. Anal. , vol.72 , pp. 245-250
    • Hu, Z.Y.1    Laizure, S.C.2    Meibohm, B.3    Herring, V.L.4    Parker, R.B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.