메뉴 건너뛰기




Volumn 27, Issue 7, 2013, Pages 579-591

Effect of a foot-drop stimulator and ankle-foot orthosis on walking performance after stroke: A multicenter randomized controlled trial

Author keywords

drop foot; functional electrical stimulation; mobility; physiological cost; stroke rehabilitation; walking speed

Indexed keywords

ADULT; AGED; ANKLE FOOT ORTHOSIS; ARTICLE; CEREBROVASCULAR ACCIDENT; CONTROLLED STUDY; CROSSOVER PROCEDURE; FEMALE; FOOT DROP STIMULATOR; HUMAN; MAJOR CLINICAL STUDY; MALE; NERVE STIMULATOR; OUTCOME ASSESSMENT; PERONEUS NERVE PARALYSIS; PHYSICAL PERFORMANCE; RANDOMIZED CONTROLLED TRIAL; SKIN IRRITATION; THERAPY EFFECT; WALKING; WALKING SPEED;

EID: 84881002506     PISSN: 15459683     EISSN: 15526844     Source Type: Journal    
DOI: 10.1177/1545968313481278     Document Type: Article
Times cited : (115)

References (24)
  • 1
    • 45449103493 scopus 로고    scopus 로고
    • Foot drop: Where, why and what to do?
    • Stewart JD. Foot drop: where, why and what to do?. Pract Neurol. 2008 ; 8: 158-169
    • (2008) Pract Neurol , vol.8 , pp. 158-169
    • Stewart, J.D.1
  • 3
    • 57849167111 scopus 로고    scopus 로고
    • Neuroprosthesis for footdrop compared with an ankle-foot orthosis: Effects on postural control during walking
    • Ring H, Treger I, Gruendlinger L, Hausdorff JM. Neuroprosthesis for footdrop compared with an ankle-foot orthosis: effects on postural control during walking. J Stroke Cerebrovasc Dis. 2009 ; 18: 41-47
    • (2009) J Stroke Cerebrovasc Dis , vol.18 , pp. 41-47
    • Ring, H.1    Treger, I.2    Gruendlinger, L.3    Hausdorff, J.M.4
  • 5
    • 0032763417 scopus 로고    scopus 로고
    • Clinical use of the Odstock dropped foot stimulator: Its effect on the speed and effort of walking
    • Taylor PN, Burridge JH, Dunkerley AL, et al. Clinical use of the Odstock dropped foot stimulator: its effect on the speed and effort of walking. Arch Phys Med Rehabil. 1999 ; 80: 1577-1583
    • (1999) Arch Phys Med Rehabil , vol.80 , pp. 1577-1583
    • Taylor, P.N.1    Burridge, J.H.2    Dunkerley, A.L.3
  • 6
    • 76649110210 scopus 로고    scopus 로고
    • Long-term therapeutic and orthotic effects of a foot drop stimulator on walking performance in progressive and nonprogressive neurological disorders
    • Stein RB, Everaert DG, Thompson AK, et al. Long-term therapeutic and orthotic effects of a foot drop stimulator on walking performance in progressive and nonprogressive neurological disorders. Neurorehabil Neural Repair. 2010 ; 24: 152-167
    • (2010) Neurorehabil Neural Repair , vol.24 , pp. 152-167
    • Stein, R.B.1    Everaert, D.G.2    Thompson, A.K.3
  • 7
    • 34547476027 scopus 로고    scopus 로고
    • A randomized controlled trial of an implantable 2-channel peroneal nerve stimulator on walking speed and activity in poststroke hemiplegia
    • Kottink AI, Hermens HJ, Nene AV, et al. A randomized controlled trial of an implantable 2-channel peroneal nerve stimulator on walking speed and activity in poststroke hemiplegia. Arch Phys Med Rehabil. 2007 ; 88: 971-978
    • (2007) Arch Phys Med Rehabil , vol.88 , pp. 971-978
    • Kottink, A.I.1    Hermens, H.J.2    Nene, A.V.3
  • 8
    • 34249687116 scopus 로고    scopus 로고
    • Phase II trial to evaluate the ActiGait implanted drop-foot stimulator in established hemiplegia
    • Burridge JH, Haugland M, Larsen B, et al. Phase II trial to evaluate the ActiGait implanted drop-foot stimulator in established hemiplegia. J Rehabil Med. 2007 ; 39: 212-218
    • (2007) J Rehabil Med , vol.39 , pp. 212-218
    • Burridge, J.H.1    Haugland, M.2    Larsen, B.3
  • 9
    • 0031817723 scopus 로고    scopus 로고
    • Functional electrical stimulation: A review of the literature published on common peroneal nerve stimulation for the correction of dropped foot
    • Burridge JH, Swain ID, Taylor PN. Functional electrical stimulation: a review of the literature published on common peroneal nerve stimulation for the correction of dropped foot. Rev Clin Gerontol. 1998 ; 8: 155-161
    • (1998) Rev Clin Gerontol , vol.8 , pp. 155-161
    • Burridge, J.H.1    Swain, I.D.2    Taylor, P.N.3
  • 10
    • 33646819009 scopus 로고    scopus 로고
    • The therapeutic effect of functional and transcutaneous electric stimulation on improving gait speed in stroke patients: A meta-analysis
    • Robbins SM, Houghton PE, Woodbury MG, Brown JL. The therapeutic effect of functional and transcutaneous electric stimulation on improving gait speed in stroke patients: a meta-analysis. Arch Phys Med Rehabil. 2006 ; 87: 853-859
    • (2006) Arch Phys Med Rehabil , vol.87 , pp. 853-859
    • Robbins, S.M.1    Houghton, P.E.2    Woodbury, M.G.3    Brown, J.L.4
  • 11
    • 2542458248 scopus 로고    scopus 로고
    • The orthotic effect of functional electrical stimulation on the improvement of walking in stroke patients with a dropped foot: A systematic review
    • Kottink AI, Oostendorp LJ, Buurke JH, Nene AV, Hermens HJ, IJzerman MJ. The orthotic effect of functional electrical stimulation on the improvement of walking in stroke patients with a dropped foot: a systematic review. Artif Organs. 2004 ; 28: 577-586
    • (2004) Artif Organs , vol.28 , pp. 577-586
    • Kottink, A.I.1    Oostendorp, L.J.2    Buurke, J.H.3    Nene, A.V.4    Hermens, H.J.5    Ijzerman, M.J.6
  • 12
    • 76649124565 scopus 로고    scopus 로고
    • Does functional electrical stimulation for foot drop strengthen corticospinal connections?
    • Everaert DG, Thompson AK, Chong SL, Stein RB. Does functional electrical stimulation for foot drop strengthen corticospinal connections?. Neurorehabil Neural Repair. 2010 ; 24: 168-177
    • (2010) Neurorehabil Neural Repair , vol.24 , pp. 168-177
    • Everaert, D.G.1    Thompson, A.K.2    Chong, S.L.3    Stein, R.B.4
  • 13
    • 0033891878 scopus 로고    scopus 로고
    • Relation between abnormal patterns of muscle activation and response to common peroneal nerve stimulation in hemiplegia
    • Burridge JH, McLellan DL. Relation between abnormal patterns of muscle activation and response to common peroneal nerve stimulation in hemiplegia. J Neurol Neurosurg Psychiatry. 2000 ; 69: 353-361
    • (2000) J Neurol Neurosurg Psychiatry , vol.69 , pp. 353-361
    • Burridge, J.H.1    McLellan, D.L.2
  • 14
    • 37549043507 scopus 로고    scopus 로고
    • Effects of a new radio frequency- controlled neuroprosthesis on gait symmetry and rhythmicity in patients with chronic hemiparesis
    • Hausdorff JM, Ring H. Effects of a new radio frequency- controlled neuroprosthesis on gait symmetry and rhythmicity in patients with chronic hemiparesis. Am J Phys Med Rehabil. 2008 ; 87: 4-13
    • (2008) Am J Phys Med Rehabil , vol.87 , pp. 4-13
    • Hausdorff, J.M.1    Ring, H.2
  • 15
    • 5344229346 scopus 로고    scopus 로고
    • Effects of a simple functional electric system and/or a hinged ankle-foot orthosis on walking in persons with incomplete spinal cord injury
    • Kim CM, Eng JJ, Whittaker MW. Effects of a simple functional electric system and/or a hinged ankle-foot orthosis on walking in persons with incomplete spinal cord injury. Arch Phys Med Rehabil. 2004 ; 85: 1718-1723
    • (2004) Arch Phys Med Rehabil , vol.85 , pp. 1718-1723
    • Kim, C.M.1    Eng, J.J.2    Whittaker, M.W.3
  • 16
    • 33746602702 scopus 로고    scopus 로고
    • Peroneal nerve stimulation versus an ankle foot orthosis for correction of footdrop in stroke: Impact on functional ambulation
    • Sheffler LR, Hennessey MT, Naples GG, Chae J. Peroneal nerve stimulation versus an ankle foot orthosis for correction of footdrop in stroke: impact on functional ambulation. Neurorehabil Neural Repair. 2006 ; 20: 355-360
    • (2006) Neurorehabil Neural Repair , vol.20 , pp. 355-360
    • Sheffler, L.R.1    Hennessey, M.T.2    Naples, G.G.3    Chae, J.4
  • 17
    • 77449113078 scopus 로고    scopus 로고
    • Is transcutaneous peroneal stimulation beneficial to patients with chronic stroke using an ankle-foot orthosis? A within-subjects study of patients' satisfaction, walking speed and physical activity level
    • van Swigchem R, Vloothuis J, den Boer J, Weerdesteyn V, Geurts AC. Is transcutaneous peroneal stimulation beneficial to patients with chronic stroke using an ankle-foot orthosis? A within-subjects study of patients' satisfaction, walking speed and physical activity level. J Rehabil Med. 2010 ; 42: 117-121
    • (2010) J Rehabil Med , vol.42 , pp. 117-121
    • Van Swigchem, R.1    Vloothuis, J.2    Den Boer, J.3    Weerdesteyn, V.4    Geurts, A.C.5
  • 18
    • 0037817686 scopus 로고    scopus 로고
    • Functional recovery following rehabilitation after hemorrhagic and ischemic stroke
    • Kelly PJ, Furie KL, Shafqat S, et al. Functional recovery following rehabilitation after hemorrhagic and ischemic stroke. Arch Phys Med Rehabil. 2003 ; 84: 968-972
    • (2003) Arch Phys Med Rehabil , vol.84 , pp. 968-972
    • Kelly, P.J.1    Furie, K.L.2    Shafqat, S.3
  • 20
    • 0019411938 scopus 로고
    • The evaluation of patient performance using long-term ambulatory monitoring technique in the domiciliary environment
    • MacGregor J. The evaluation of patient performance using long-term ambulatory monitoring technique in the domiciliary environment. Physiotherapy. 1981 ; 67: 30-33
    • (1981) Physiotherapy , vol.67 , pp. 30-33
    • MacGregor, J.1
  • 21
    • 0032905424 scopus 로고    scopus 로고
    • Rivermead Mobility Index: A brief review of research to date
    • Forlander DA, Bohannon RW. Rivermead Mobility Index: a brief review of research to date. Clin Rehabil. 1999 ; 13: 97-100
    • (1999) Clin Rehabil , vol.13 , pp. 97-100
    • Forlander, D.A.1    Bohannon, R.W.2
  • 22
    • 84907040929 scopus 로고
    • The Rivermead Mobility Index: A further development of the Rivermead Motor Assessment
    • Collen FM, Wade DT, Robb GF, Bradshaw CM. The Rivermead Mobility Index: a further development of the Rivermead Motor Assessment. Int Disabil Stud. 1991 ; 13: 50-54
    • (1991) Int Disabil Stud , vol.13 , pp. 50-54
    • Collen, F.M.1    Wade, D.T.2    Robb, G.F.3    Bradshaw, C.M.4
  • 23
    • 4043162788 scopus 로고    scopus 로고
    • The effect of an ankle-foot orthosis on walking ability in chronic stroke patients: A randomized controlled trial
    • de Wit DC, Buurke JH, Nijlant JM, Ijzerman MJ, Hermens HJ. The effect of an ankle-foot orthosis on walking ability in chronic stroke patients: a randomized controlled trial. Clin Rehabil. 2004 ; 18: 550-557
    • (2004) Clin Rehabil , vol.18 , pp. 550-557
    • De Wit, D.C.1    Buurke, J.H.2    Nijlant, J.M.3    Ijzerman, M.J.4    Hermens, H.J.5
  • 24
    • 79961016979 scopus 로고    scopus 로고
    • User experiences, preferences and choices relating to functional electrical stimulation and ankle foot orthoses for foot-drop after stroke
    • Bulley C, Shiels J, Wilkie K, Salisbury L. User experiences, preferences and choices relating to functional electrical stimulation and ankle foot orthoses for foot-drop after stroke. Physiotherapy. 2011 ; 97: 226-233
    • (2011) Physiotherapy , vol.97 , pp. 226-233
    • Bulley, C.1    Shiels, J.2    Wilkie, K.3    Salisbury, L.4