메뉴 건너뛰기




Volumn 15, Issue 8, 2013, Pages 1205-1209

Transcutaneous lead implantation connected to an externalized pacemaker in patients with implantable cardiac defibrillator/pacemaker infection and pacemaker dependency

Author keywords

CIED infection; Pacemaker; Temporary pacing

Indexed keywords

ANTIBIOTIC AGENT; C REACTIVE PROTEIN;

EID: 84880960543     PISSN: 10995129     EISSN: 15322092     Source Type: Journal    
DOI: 10.1093/europace/eut031     Document Type: Article
Times cited : (36)

References (19)
  • 1
    • 50449091204 scopus 로고    scopus 로고
    • The world survey of cardiac pacing and cardioverter-defibrillators: Calendar year 2005 an international cardiac pacing and electrophysiology society (icpes) project
    • Mond HG, Irwin M, Ector H, Proclemer A. The world survey of cardiac pacing and cardioverter-defibrillators: Calendar year 2005 an International Cardiac Pacing and Electrophysiology Society (ICPES) project. Pacing Clin Electrophysiol 2008;31: 1202-12
    • (2008) Pacing Clin Electrophysiol , vol.31 , pp. 1202-1212
    • Mond, H.G.1    Irwin, M.2    Ector, H.3    Proclemer, A.4
  • 2
    • 77953180116 scopus 로고    scopus 로고
    • Implantation trends and patient profiles for pacemakers and implantable cardioverter defibrillators in the united states 1993-2006
    • Kurtz SM, Ochoa JA, Lau E, Shkolnikov Y, Pavri BB, Frisch D et al. Implantation trends and patient profiles for pacemakers and implantable cardioverter defibrillators in the United States: 1993-2006. Pacing Clin Electrophysiol 2010;33:705-11
    • (2010) Pacing Clin Electrophysiol , vol.33 , pp. 705-711
    • Kurtz, S.M.1    Ochoa, J.A.2    Lau, E.3    Shkolnikov, Y.4    Pavri, B.B.5    Frisch, D.6
  • 3
    • 0037149716 scopus 로고    scopus 로고
    • Multicenter automatic defibrillator implantation trial II investigators. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction
    • Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS et al. Multicenter automatic defibrillator implantation trial II investigators. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med 2002;346:877-83
    • (2002) N Engl J Med , vol.346 , pp. 877-883
    • Moss, A.J.1    Zareba, W.2    Hall, W.J.3    Klein, H.4    Wilber, D.J.5    Cannom, D.S.6
  • 4
    • 19944429413 scopus 로고    scopus 로고
    • Sudden cardiac death in heart failure trial (scd-heft) investigators amiodarone or an implantable cardioverter-defibrillator for congestive heart failure
    • Bardy GH, Lee KL, Mark DB, Poole JE, Packer DL, Boineau R et al. Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT) investigators. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. N Engl J Med 2005; 352:225-37
    • (2005) N Engl J Med , vol.352 , pp. 225-237
    • Bardy, G.H.1    Lee, K.L.2    Mark, D.B.3    Poole, J.E.4    Packer, D.L.5    Boineau, R.6
  • 5
    • 33746208049 scopus 로고    scopus 로고
    • Rising rates of cardiac rhythm management device infections in the United States 1996 through 2003
    • Voigt A, Shalaby A, Saba S. Rising rates of cardiac rhythm management device infections in the United States: 1996 through 2003. J Am Coll Cardiol 2006;48:590-1
    • (2006) J Am Coll Cardiol , vol.48 , pp. 590-591
    • Voigt, A.1    Shalaby, A.2    Saba, S.3
  • 6
    • 80052087661 scopus 로고    scopus 로고
    • 16-year trends in the infection burden for pacemakers and implantable cardioverter-defibrillators in the united states 1993 to 2008
    • Greenspon AJ, Patel JD, Lau E, Ochoa JA, Frisch DR, Ho RT et al. 16-year trends in the infection burden for pacemakers and implantable cardioverter-defibrillators in the United States 1993 to 2008. J Am Coll Cardiol 2011;58:1001-6
    • (2011) J Am Coll Cardiol , vol.58 , pp. 1001-1006
    • Greenspon, A.J.1    Patel, J.D.2    Lau, E.3    Ochoa, J.A.4    Frisch, D.R.5    Ho, R.T.6
  • 7
    • 33747114958 scopus 로고    scopus 로고
    • Percutaneous lead implantation connected to an external device in stimulationdependent patients with systemic infection -A prospective and controlled study
    • Braun MU, Rauwolf T, Bock M, Kappert U, Boscheri A, Schnabel A et al. Percutaneous lead implantation connected to an external device in stimulationdependent patients with systemic infection -A prospective and controlled study. Pacing Clin Electrophysiol 2006;29:875-9
    • (2006) Pacing Clin Electrophysiol , vol.29 , pp. 875-879
    • Braun, M.U.1    Rauwolf, T.2    Bock, M.3    Kappert, U.4    Boscheri, A.5    Schnabel, A.6
  • 8
    • 84860192436 scopus 로고    scopus 로고
    • Long-Term outcomes following infection of cardiac implantable electronic devices: A prospective matched cohort study
    • Deharo JC, Quatre A, Mancini J, Khairy P, Le Dolley Y, Casalta JP et al. Long-Term outcomes following infection of cardiac implantable electronic devices: A prospective matched cohort study. Heart 2012;98:724-31
    • (2012) Heart , vol.98 , pp. 724-731
    • Deharo, J.C.1    Quatre, A.2    Mancini, J.3    Khairy, P.4    Le Dolley, Y.5    Casalta, J.P.6
  • 9
    • 76649138577 scopus 로고    scopus 로고
    • American heart association rheumatic fever endocarditis and kawasaki disease committee; council on cardiovascular disease in young; council on cardiovascular surgery and anesthesia; council on cardiovascular nursing; council on clinical cardiology; interdisciplinary council on quality of care
    • American Heart Association. Update on cardiovascular implantable electronic device infections and their management: A scientific statement from the American Heart Association
    • Baddour LM, Epstein AE, Erickson CC, Knight BP, Levison ME, Lockhart PB et al. American Heart Association Rheumatic Fever, Endocarditis, and Kawasaki Disease Committee; Council on Cardiovascular Disease in Young; Council on Cardiovascular Surgery and Anesthesia; Council on Cardiovascular Nursing; Council on Clinical Cardiology; Interdisciplinary Council on Quality of Care; American Heart Association. Update on cardiovascular implantable electronic device infections and their management: A scientific statement from the American Heart Association. Circulation 2010;121:458-77
    • (2010) Circulation , vol.121 , pp. 458-477
    • Baddour, L.M.1    Epstein, A.E.2    Erickson, C.C.3    Knight, B.P.4    Levison, M.E.5    Lockhart, P.B.6
  • 10
    • 67549100824 scopus 로고    scopus 로고
    • Heart rhythm society; american heart association transvenous lead extraction: Heart rhythm society expert consensus on facilities, training, indications, and patient management: This document was endorsed by the american heart association aha)
    • Wilkoff BL, Love CJ, Byrd CL, Bongiorni MG, Carrillo RG, Crossley GH III et al. Heart Rhythm Society; American Heart Association. Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management: This document was endorsed by the American Heart Association (AHA). Heart Rhythm 2009;6:1085-104
    • (2009) Heart Rhythm , vol.6 , pp. 1085-1104
    • Wilkoff, B.L.1    Love, C.J.2    Byrd, C.L.3    Bongiorni, M.G.4    Carrillo, R.G.5    Crossley III, G.H.6
  • 11
    • 78049277251 scopus 로고    scopus 로고
    • Pacemaker and internal cardioverter defibrillator lead extraction: A safe and effective surgical approach
    • Kratz JM, Toole JM. Pacemaker and internal cardioverter defibrillator lead extraction: A safe and effective surgical approach. Ann Thorac Surg 2010;90:1411-7
    • (2010) Ann Thorac Surg , vol.90 , pp. 1411-1417
    • Kratz, J.M.1    Toole, J.M.2
  • 12
    • 77953849157 scopus 로고    scopus 로고
    • Extraction of cardiac rhythm devices: Indications, techniques and outcomes for the removal of pacemaker and defibrillator leads
    • Farooqi FM, Talsania S, Hamid S, Rinaldi CA. Extraction of cardiac rhythm devices: Indications, techniques and outcomes for the removal of pacemaker and defibrillator leads. Int J Clin Pract 2010;64:1140-7
    • (2010) Int J Clin Pract , vol.64 , pp. 1140-1147
    • Farooqi, F.M.1    Talsania, S.2    Hamid, S.3    Rinaldi, C.A.4
  • 13
    • 84863406774 scopus 로고    scopus 로고
    • Trends, indications and outcomes of cardiac implantable device system extraction: A single UK centre experience over the last decade
    • Arujuna A, Williams S, Whittaker J, Shetty A, Roy D, Bostock J et al. Trends, indications and outcomes of cardiac implantable device system extraction: A single UK centre experience over the last decade. Int J Clin Pract 2012;66:218-25
    • (2012) Int J Clin Pract , vol.66 , pp. 218-225
    • Arujuna, A.1    Williams, S.2    Whittaker, J.3    Shetty, A.4    Roy, D.5    Bostock, J.6
  • 14
    • 81255134077 scopus 로고    scopus 로고
    • Complete removal as a routine treatment for any cardiovascular implantable electronic device-Associated infection
    • Pichlmaier M, Knigina L, Kutschka I, Bara C, Oswald H, Klein G et al. Complete removal as a routine treatment for any cardiovascular implantable electronic device-Associated infection. J Thorac Cardiovasc Surg 2011;142:1482-90
    • (2011) J Thorac Cardiovasc Surg , vol.142 , pp. 1482-1490
    • Pichlmaier, M.1    Knigina, L.2    Kutschka, I.3    Bara, C.4    Oswald, H.5    Klein, G.6
  • 15
    • 33645707758 scopus 로고    scopus 로고
    • One stage side-To-side replacement of infected pulse generators and leads
    • Nandyala R, Parsonnet V. One stage side-To-side replacement of infected pulse generators and leads. Pacing Clin Electrophysiol 2006;29:393-6
    • (2006) Pacing Clin Electrophysiol , vol.29 , pp. 393-396
    • Nandyala, R.1    Parsonnet, V.2
  • 16
    • 0033770747 scopus 로고    scopus 로고
    • Diagnosis and management of infections involving implantable electrophysiologic cardiac devices
    • Chua JD, Wilkoff BL, Lee I, Juratli N, Longworth DL, Gordon SM. Diagnosis and management of infections involving implantable electrophysiologic cardiac devices. Ann Intern Med 2000;133:604-8
    • (2000) Ann Intern Med , vol.133 , pp. 604-608
    • Chua, J.D.1    Wilkoff, B.L.2    Lee, I.3    Juratli, N.4    Longworth, D.L.5    Gordon, S.M.6
  • 17
    • 54949091119 scopus 로고    scopus 로고
    • Use of tunnelled active fixation leads allows reliable temporary pacing over prolonged periods
    • Orsbourn G, Lever N, Harding SA. Use of tunnelled active fixation leads allows reliable temporary pacing over prolonged periods. Intern Med J 2008; 38:735-8
    • (2008) Intern Med J , vol.38 , pp. 735-738
    • Orsbourn, G.1    Lever, N.2    Harding, S.A.3
  • 18
    • 84862976427 scopus 로고    scopus 로고
    • Temporary transvenous VDD pacing as a bridge to permanent pacemaker implantation in patients with sepsis and haemodynamically significant atrioventricular block
    • Lepillier A, Otmani A, Waintraub X, Ollitrault J, Le Heuzey J, Lavergne T. Temporary transvenous VDD pacing as a bridge to permanent pacemaker implantation in patients with sepsis and haemodynamically significant atrioventricular block. Europace 2012;14:981-5
    • (2012) Europace , vol.14 , pp. 981-985
    • Lepillier, A.1    Otmani, A.2    Waintraub, X.3    Ollitrault, J.4    Le Heuzey, J.5    Lavergne, T.6
  • 19
    • 0037301989 scopus 로고    scopus 로고
    • Prolonged temporary cardiac pacing using subcutaneous tunnelled active-fixation permanent pacing leads
    • Lever N, Ferguson JD, Bashir Y, Channon KM. Prolonged temporary cardiac pacing using subcutaneous tunnelled active-fixation permanent pacing leads. Heart 2003;89:209-10
    • (2003) Heart , vol.89 , pp. 209-210
    • Lever, N.1    Ferguson, J.D.2    Bashir, Y.3    Channon, K.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.