A novel technique for increasing charge injection capacity of neural electrodes for efficacious and safe neural stimulation

Author keywords

[No Author keywords available]

Indexed keywords

CONTROL SAMPLES; ELECTROCHEMICAL CHARACTERIZATIONS; ELECTRODE ARRAYS; GEOMETRICAL SURFACES; NEURAL ACTIVITY; NEURAL STIMULATIONS; NOVEL TECHNIQUES; SMALL AREA; SPUTTERED IRIDIUM OXIDE; SURFACE AREA; SURFACE AREA OF ELECTRODE; SURFACE MODIFIED ELECTRODES;

EID: 84880957230     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/EMBC.2012.6347151     Document Type: Conference Paper
Times cited : (14)

References (10)
  • 1
    • 34547636880 scopus 로고    scopus 로고
    • Technology insight: Future neuroprosthetic therapies for disorders of the nervous system
    • R. A. Normann, "Technology Insight: future neuroprosthetic therapies for disorders of the nervous system," Nature Clinical Practice: Neurology, vol. 3(8), pp. 444-452, 2007.
    • (2007) Nature Clinical Practice: Neurology , vol.3 , Issue.8 , pp. 444-452
    • Normann, R.A.1
  • 3
    • 12344323809 scopus 로고    scopus 로고
    • Electrical stimulation of excitable tissue: Design of efficacious and safe protocols
    • D. R. Merrill, M. Bikson, J. G. R. Jefferys, "Electrical stimulation of excitable tissue: design of efficacious and safe protocols," Journal of Neuroscience Methods, vol. 141, pp. 171-198, 2005.
    • (2005) Journal of Neuroscience Methods , vol.141 , pp. 171-198
    • Merrill, D.R.1    Bikson, M.2    Jefferys, J.G.R.3
  • 4
    • 50249084472 scopus 로고    scopus 로고
    • Neural stimulation and recording electrodes
    • S. F. Cogan, "Neural Stimulation and Recording Electrodes," Annual Review of Biomedical Engineering, vol. 10, pp. 275-309, 2008.
    • (2008) Annual Review of Biomedical Engineering , vol.10 , pp. 275-309
    • Cogan, S.F.1
  • 5
    • 78049280174 scopus 로고    scopus 로고
    • Wafer scale fabrication of penetrating neural electrode arrays
    • R. Bhandari, S. Negi, and F. Solzbacher, "Wafer Scale Fabrication of Penetrating Neural Electrode Arrays," Biomedical Microdevices, vol. 12 (5), pp. 797-807, 2010.
    • (2010) Biomedical Microdevices , vol.12 , Issue.5 , pp. 797-807
    • Bhandari, R.1    Negi, S.2    Solzbacher, F.3
  • 7
    • 72449176835 scopus 로고    scopus 로고
    • Neural electrode degradation from continuous electrical stimulation: Comparison of sputtered and activated iridium oxide
    • S. Negi, R. Bhandari, L. Rieth, R. V. Wagenen, and F. Solzbacher, "Neural Electrode Degradation from Continuous Electrical Stimulation: Comparison of Sputtered and Activated Iridium Oxide," Journal of Neuroscience Methods, vol. 186, pp. 8-17, 2010.
    • (2010) Journal of Neuroscience Methods , vol.186 , pp. 8-17
    • Negi, S.1    Bhandari, R.2    Rieth, L.3    Wagenen, R.V.4    Solzbacher, F.5
  • 8
    • 77950870803 scopus 로고    scopus 로고
    • In vitro comparison of sputtered iridium oxide and platinum coated neural implantable microelectrodes arrays
    • S. Negi, R. Bhandari, L. Rieth, and F. Solzbacher, "In vitro comparison of sputtered iridium oxide and platinum coated neural implantable microelectrodes arrays," Biomedical materials, vol. 5, 2010.
    • (2010) Biomedical Materials , vol.5
    • Negi, S.1    Bhandari, R.2    Rieth, L.3    Solzbacher, F.4
  • 9
    • 0347927495 scopus 로고    scopus 로고
    • In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
    • J. D. Weiland, D. J. Anderson, and M. S. Humanyun, "In Vitro Electrical Properties for Iridium Oxide versus Titanium Nitride Stimulating Electrodes," IEEE transactions on Biomedical Engineering, vol. 49(12), pp. 1574-1579, 2002.
    • (2002) IEEE Transactions on Biomedical Engineering , vol.49 , Issue.12 , pp. 1574-1579
    • Weiland, J.D.1    Anderson, D.J.2    Humanyun, M.S.3
  • 10
    • 50049128696 scopus 로고    scopus 로고
    • Collagenase-aided intracortical microelectrode array insertion: Effects of insertion force and recording performance
    • Sept
    • K.J. Paralikar, and R.S. Clement, "Collagenase-aided intracortical microelectrode array insertion: Effects of insertion force and recording performance," IEEE Transaction of Biomedical Engineering, vol. 55, pp. 2258-2267, Sept 2008.
    • (2008) IEEE Transaction of Biomedical Engineering , vol.55 , pp. 2258-2267
    • Paralikar, K.J.1    Clement, R.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.