메뉴 건너뛰기




Volumn 31, Issue 7, 2013, Pages 1074-1080

Fast approximation to pixelwise relaxivity maps: Validation in iron overloaded subjects

Author keywords

Fast R2* mapping; Iron overload assessment; Liver

Indexed keywords

ADULT; ALGORITHM; ANALYTICAL ERROR; ARTICLE; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; FEMALE; HUMAN; IMAGE DISPLAY; IMAGE QUALITY; INTERMETHOD COMPARISON; IRON OVERLOAD; LEVENBERG MARQUADT ALGORITHM; LIVER DISEASE; MAJOR CLINICAL STUDY; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SCANNER; OBSERVER BIAS; PRIORITY JOURNAL; PSEUDO PIXELWISE MAPPING ALGORITHM; QUALITATIVE ANALYSIS; QUANTITATIVE ANALYSIS; REFERENCE VALUE; REPRODUCIBILITY; STATISTICAL PARAMETERS; VALIDATION STUDY;

EID: 84880802759     PISSN: 0730725X     EISSN: 18735894     Source Type: Journal    
DOI: 10.1016/j.mri.2013.05.005     Document Type: Article
Times cited : (14)

References (21)
  • 2
    • 20844460608 scopus 로고    scopus 로고
    • Survival and complications in patients with thalassemia major treated with transfusion and deferoxamine
    • Borgna-Pignatti C., Rugolotto S., De Stefano P., et al. Survival and complications in patients with thalassemia major treated with transfusion and deferoxamine. Haematologica 2004, 89(10):1187-1193.
    • (2004) Haematologica , vol.89 , Issue.10 , pp. 1187-1193
    • Borgna-Pignatti, C.1    Rugolotto, S.2    De Stefano, P.3
  • 3
    • 70349545970 scopus 로고    scopus 로고
    • Iron overload and toxicity: the hidden risk of multiple blood transfusions
    • Shander A., Cappellini M.D., Goodnough L.T. Iron overload and toxicity: the hidden risk of multiple blood transfusions. Vox Sang 2009, 97(3):185-197.
    • (2009) Vox Sang , vol.97 , Issue.3 , pp. 185-197
    • Shander, A.1    Cappellini, M.D.2    Goodnough, L.T.3
  • 4
    • 0034601375 scopus 로고    scopus 로고
    • Hepatic iron concentration and total body iron stores in thalassemia major
    • Angelucci E., Brittenham G.M., McLaren C.E., et al. Hepatic iron concentration and total body iron stores in thalassemia major. N Engl J Med 2000, 343(5):327-331.
    • (2000) N Engl J Med , vol.343 , Issue.5 , pp. 327-331
    • Angelucci, E.1    Brittenham, G.M.2    McLaren, C.E.3
  • 5
    • 0028858058 scopus 로고
    • Uneven hepatic iron and phosphorus distribution in beta-thalassemia
    • Ambu R., Crisponi G., Sciot R., et al. Uneven hepatic iron and phosphorus distribution in beta-thalassemia. J Hepatol 1995, 23(5):544-549.
    • (1995) J Hepatol , vol.23 , Issue.5 , pp. 544-549
    • Ambu, R.1    Crisponi, G.2    Sciot, R.3
  • 7
    • 0001265554 scopus 로고    scopus 로고
    • Variability in hepatic iron concentration measurement from needle-biopsy specimens
    • Villeneuve J.P., Bilodeau M., Lepage R., Cote J., Lefebvre M. Variability in hepatic iron concentration measurement from needle-biopsy specimens. J Hepatol 1996, 25(2):172-177.
    • (1996) J Hepatol , vol.25 , Issue.2 , pp. 172-177
    • Villeneuve, J.P.1    Bilodeau, M.2    Lepage, R.3    Cote, J.4    Lefebvre, M.5
  • 8
    • 18044399191 scopus 로고    scopus 로고
    • Cardiovascular T2*-star (T2**) magnetic resonance for the early diagnosis of myocardial iron overload
    • Anderson L.J., Holden S., Davis B., et al. Cardiovascular T2*-star (T2**) magnetic resonance for the early diagnosis of myocardial iron overload. Eur Heart J 2001, 22(23):2171-2179.
    • (2001) Eur Heart J , vol.22 , Issue.23 , pp. 2171-2179
    • Anderson, L.J.1    Holden, S.2    Davis, B.3
  • 9
    • 33645055937 scopus 로고    scopus 로고
    • Evaluation of the efficacy of oral deferiprone in beta-thalassemia major by multislice multiecho T2*
    • Pepe A., Lombardi M., Positano V., et al. Evaluation of the efficacy of oral deferiprone in beta-thalassemia major by multislice multiecho T2*. Eur J Haematol 2006, 76(3):183-192.
    • (2006) Eur J Haematol , vol.76 , Issue.3 , pp. 183-192
    • Pepe, A.1    Lombardi, M.2    Positano, V.3
  • 10
    • 38549150853 scopus 로고    scopus 로고
    • A T2*magnetic resonance imaging study of pancreatic iron overload in thalassemia major
    • Au W.Y., Lam W.W., Chu W., et al. A T2*magnetic resonance imaging study of pancreatic iron overload in thalassemia major. Haematologica 2008, 93(1):116-119.
    • (2008) Haematologica , vol.93 , Issue.1 , pp. 116-119
    • Au, W.Y.1    Lam, W.W.2    Chu, W.3
  • 11
    • 78650392267 scopus 로고    scopus 로고
    • Pancreatic iron loading in chronically transfused sickle cell disease is lower than in thalassaemia major
    • Noetzli L.J., Coates T.D., Wood J.C. Pancreatic iron loading in chronically transfused sickle cell disease is lower than in thalassaemia major. Br J Haematol 2011, 152(2):229-233.
    • (2011) Br J Haematol , vol.152 , Issue.2 , pp. 229-233
    • Noetzli, L.J.1    Coates, T.D.2    Wood, J.C.3
  • 12
    • 84855960714 scopus 로고    scopus 로고
    • Pituitary iron and volume predict hypogonadism in transfusional iron overload
    • Noetzli L.J., Panigrahy A., Mittelman S.D., et al. Pituitary iron and volume predict hypogonadism in transfusional iron overload. Am J Hematol 2012, 87(2):167-171.
    • (2012) Am J Hematol , vol.87 , Issue.2 , pp. 167-171
    • Noetzli, L.J.1    Panigrahy, A.2    Mittelman, S.D.3
  • 13
    • 79951838524 scopus 로고    scopus 로고
    • Relaxivity-iron calibration in hepatic iron overload: probing underlying biophysical mechanisms using a Monte Carlo model
    • Ghugre N.R., Wood J.C. Relaxivity-iron calibration in hepatic iron overload: probing underlying biophysical mechanisms using a Monte Carlo model. Magn Reson Med 2011, 65(3):837-847.
    • (2011) Magn Reson Med , vol.65 , Issue.3 , pp. 837-847
    • Ghugre, N.R.1    Wood, J.C.2
  • 14
    • 23744459788 scopus 로고    scopus 로고
    • MRI R2 and R2* mapping accurately estimates hepatic iron concentration in transfusion-dependent thalassemia and sickle cell disease patients
    • Wood J.C., Enriquez C., Ghugre N., et al. MRI R2 and R2* mapping accurately estimates hepatic iron concentration in transfusion-dependent thalassemia and sickle cell disease patients. Blood 2005, 106(4):1460-1465.
    • (2005) Blood , vol.106 , Issue.4 , pp. 1460-1465
    • Wood, J.C.1    Enriquez, C.2    Ghugre, N.3
  • 15
    • 59249100314 scopus 로고    scopus 로고
    • Improved T2*assessment in liver iron overload by magnetic resonance imaging
    • Positano V., Salani B., Pepe A., et al. Improved T2*assessment in liver iron overload by magnetic resonance imaging. Magn Reson Imaging 2009, 27(2):188-197.
    • (2009) Magn Reson Imaging , vol.27 , Issue.2 , pp. 188-197
    • Positano, V.1    Salani, B.2    Pepe, A.3
  • 16
    • 11244355277 scopus 로고    scopus 로고
    • Noninvasive measurement and imaging of liver iron concentrations using proton magnetic resonance
    • St Pierre T.G., Clark P.R., Chua-anusorn W., et al. Noninvasive measurement and imaging of liver iron concentrations using proton magnetic resonance. Blood 2005, 105(2):855-861.
    • (2005) Blood , vol.105 , Issue.2 , pp. 855-861
    • St Pierre, T.G.1    Clark, P.R.2    Chua-anusorn, W.3
  • 17
    • 84861228543 scopus 로고    scopus 로고
    • Measurement of liver iron overload: noninvasive calibration of MRI-R(2) * by magnetic iron detector susceptometer
    • Gianesin B., Zefiro D., Musso M., et al. Measurement of liver iron overload: noninvasive calibration of MRI-R(2) * by magnetic iron detector susceptometer. Magn Reson Med 2012, 67(6):1782-1786.
    • (2012) Magn Reson Med , vol.67 , Issue.6 , pp. 1782-1786
    • Gianesin, B.1    Zefiro, D.2    Musso, M.3
  • 18
    • 0029657994 scopus 로고    scopus 로고
    • T2* maximum likelihood estimation from multiple spin-echo magnitude images
    • Bonny J.M., Zanca M., Boire J.Y., Veyre A. T2* maximum likelihood estimation from multiple spin-echo magnitude images. Magn Reson Med 1996, 36(2):287-293.
    • (1996) Magn Reson Med , vol.36 , Issue.2 , pp. 287-293
    • Bonny, J.M.1    Zanca, M.2    Boire, J.Y.3    Veyre, A.4
  • 19
    • 16844363974 scopus 로고    scopus 로고
    • Blood oxygen level-dependent MRI of cerebral CO2 reactivity in severe carotid stenosis and occlusion
    • Ziyeh S., Rick J., Reinhard M., Hetzel A., Mader I., Speck O. Blood oxygen level-dependent MRI of cerebral CO2 reactivity in severe carotid stenosis and occlusion. Stroke 2005, 36(4):751-756.
    • (2005) Stroke , vol.36 , Issue.4 , pp. 751-756
    • Ziyeh, S.1    Rick, J.2    Reinhard, M.3    Hetzel, A.4    Mader, I.5    Speck, O.6
  • 20
    • 69149087214 scopus 로고    scopus 로고
    • Quantitative assessment of brain iron by R(2)* relaxometry in patients with clinically isolated syndrome and relapsing-remitting multiple sclerosis
    • Khalil M., Enzinger C., Langkammer C., et al. Quantitative assessment of brain iron by R(2)* relaxometry in patients with clinically isolated syndrome and relapsing-remitting multiple sclerosis. Mult Scler 2009, 15(9):1048-1054.
    • (2009) Mult Scler , vol.15 , Issue.9 , pp. 1048-1054
    • Khalil, M.1    Enzinger, C.2    Langkammer, C.3
  • 21
    • 79952613531 scopus 로고    scopus 로고
    • Magnetosome-like ferrimagnetic iron oxide nanocubes for highly sensitive MRI of single cells and transplanted pancreatic islets
    • Lee N., Kim H., Choi S.H., et al. Magnetosome-like ferrimagnetic iron oxide nanocubes for highly sensitive MRI of single cells and transplanted pancreatic islets. Proc Natl Acad Sci U S A 2011, 108(7):2662-2667.
    • (2011) Proc Natl Acad Sci U S A , vol.108 , Issue.7 , pp. 2662-2667
    • Lee, N.1    Kim, H.2    Choi, S.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.