메뉴 건너뛰기




Volumn 84, Issue 4, 2013, Pages 332-335

First UK evaluation of an automated ultraviolet-C room decontamination device (Tru-D™)

Author keywords

Decontamination; TRU D; Ultraviolet C (UV C)

Indexed keywords

ARTICLE; DISINFECTION; GENERAL MEDICAL DEVICE; HUMAN; METHICILLIN RESISTANT STAPHYLOCOCCUS AUREUS; OPERATING ROOM; PETRI DISH; ULTRAVIOLET C RADIATION; VANCOMYCIN RESISTANT ENTEROCOCCUS;

EID: 84880579726     PISSN: 01956701     EISSN: 15322939     Source Type: Journal    
DOI: 10.1016/j.jhin.2013.05.005     Document Type: Article
Times cited : (48)

References (8)
  • 1
    • 33846921827 scopus 로고    scopus 로고
    • Epic2: National evidence-based guidelines for preventing healthcare-associated infections in NHS Hospitals in England
    • Pratt R.J., Pellowe C.M., Wilson J.A., et al. epic2: National evidence-based guidelines for preventing healthcare-associated infections in NHS Hospitals in England. JHosp Infect 2007, 65(Suppl 1):S1-S64.
    • (2007) JHosp Infect , vol.65 , Issue.SUPPL 1
    • Pratt, R.J.1    Pellowe, C.M.2    Wilson, J.A.3
  • 3
    • 2342485984 scopus 로고    scopus 로고
    • Tackling contamination of the hospital environment by meticillin-resistant Staphylococcus aureus (MRSA): a comparison between conventional terminal cleaning and hydrogen peroxide vapour decontamination
    • French G.L., Otter J.A., Shannon K.P., Adams N.M., Watling D., Parks M.J. Tackling contamination of the hospital environment by meticillin-resistant Staphylococcus aureus (MRSA): a comparison between conventional terminal cleaning and hydrogen peroxide vapour decontamination. JHosp Infect 2004, 57:31-37.
    • (2004) JHosp Infect , vol.57 , pp. 31-37
    • French, G.L.1    Otter, J.A.2    Shannon, K.P.3    Adams, N.M.4    Watling, D.5    Parks, M.J.6
  • 6
    • 0018092382 scopus 로고
    • Inactivation of Bacillus thuringiensis spores by ultraviolet and visible light
    • Griego V.M., Spence K.D. Inactivation of Bacillus thuringiensis spores by ultraviolet and visible light. Appl Environ Microbiol 1978, 35:906-910.
    • (1978) Appl Environ Microbiol , vol.35 , pp. 906-910
    • Griego, V.M.1    Spence, K.D.2
  • 7
    • 77955103443 scopus 로고    scopus 로고
    • Evaluation of an automated ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens in hospital rooms
    • Nerandzic N.M., Cadnum J.L., Pultz M.J., Donskey C.J. Evaluation of an automated ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens in hospital rooms. BMC Infect Dis 2010, 10:197-204.
    • (2010) BMC Infect Dis , vol.10 , pp. 197-204
    • Nerandzic, N.M.1    Cadnum, J.L.2    Pultz, M.J.3    Donskey, C.J.4
  • 8
    • 84859357879 scopus 로고    scopus 로고
    • Comparison of the microbiological efficacy of hydrogen peroxide vapor and ultraviolet light processes for room decontamination
    • Havill N.L., Moore B.A., Boyce J.M. Comparison of the microbiological efficacy of hydrogen peroxide vapor and ultraviolet light processes for room decontamination. Infect Control Hosp Epidemiol 2012, 33:507-512.
    • (2012) Infect Control Hosp Epidemiol , vol.33 , pp. 507-512
    • Havill, N.L.1    Moore, B.A.2    Boyce, J.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.