메뉴 건너뛰기




Volumn 60, Issue 2, 2013, Pages 74-78

Orotracheal intubation difficulty with lighted stylet: Correlation of body mass index and neck circumference;Dificultad para la intubación orotraqueal con estilete luminoso: Correlación del índice de masa corporal y circunferencia cervical

Author keywords

Body mass index; Cervical circumference; Difficult intubation; Lighted stylet; Tracheal intubation

Indexed keywords

ADOLESCENT; ADULT; AGED; AIRWAY OBSTRUCTION; ANTHROPOMETRY; ARTICLE; BODY MASS; BODY SIZE; DIAGNOSTIC IMAGING; ELECTIVE SURGERY; ENDOTRACHEAL INTUBATION; EQUIPMENT; EQUIPMENT DESIGN; FEMALE; GENERAL ANESTHESIA; HISTOLOGY; HUMAN; LARYNGOSCOPE; MALE; MIDDLE AGED; NECK;

EID: 84880431796     PISSN: 00349356     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.redar.2012.09.014     Document Type: Article
Times cited : (3)

References (13)
  • 1
    • 23944457635 scopus 로고    scopus 로고
    • Cervical spine motion: a fluoroscopic comparison during intubation with lighted stylet GlideScope, and Macintosh laryngoscope
    • Turkstra T.P., Craen R.A., Pelz D.M., Gelb A.W. Cervical spine motion: a fluoroscopic comparison during intubation with lighted stylet GlideScope, and Macintosh laryngoscope. Anesth Analg 2005, 101:910-915.
    • (2005) Anesth Analg , vol.101 , pp. 910-915
    • Turkstra, T.P.1    Craen, R.A.2    Pelz, D.M.3    Gelb, A.W.4
  • 2
    • 0034928140 scopus 로고    scopus 로고
    • Lightwand intubation using Trachlight: a brief review of current knowledge
    • Agrò F., Hung O.R., Cataldo R., Carassiti M., Gherardi S. Lightwand intubation using Trachlight: a brief review of current knowledge. Can J Anesth 2001, 48:592-599.
    • (2001) Can J Anesth , vol.48 , pp. 592-599
    • Agrò, F.1    Hung, O.R.2    Cataldo, R.3    Carassiti, M.4    Gherardi, S.5
  • 3
    • 62449245558 scopus 로고    scopus 로고
    • Trachlight assisted proseal laryngeal mask airway insertion
    • Mahajan R., Batra YK Trachlight assisted proseal laryngeal mask airway insertion. Paediatr Anaesth 2009, 19:412-413.
    • (2009) Paediatr Anaesth , vol.19 , pp. 412-413
    • Mahajan, R.1    Batra, Y.K.2
  • 4
    • 44949236956 scopus 로고    scopus 로고
    • Trachlight assited insertion of nasogastric tube (Letter)
    • Mahajan R., Gupta R., Shafi F., Charak D.S. Trachlight assited insertion of nasogastric tube (Letter). Anaesthesia 2008, 63:785.
    • (2008) Anaesthesia , vol.63 , pp. 785
    • Mahajan, R.1    Gupta, R.2    Shafi, F.3    Charak, D.S.4
  • 5
    • 0036071887 scopus 로고    scopus 로고
    • Hemodynamic responses to tracheal intubation with laryngoscope versus lightwand intubating device (Trachlight) in adults with normal airway
    • Takahashi S., Mizutani T., Miyabe M., Toyooka H. Hemodynamic responses to tracheal intubation with laryngoscope versus lightwand intubating device (Trachlight) in adults with normal airway. Anesth Analg 2002, 95:480-484.
    • (2002) Anesth Analg , vol.95 , pp. 480-484
    • Takahashi, S.1    Mizutani, T.2    Miyabe, M.3    Toyooka, H.4
  • 6
    • 0041976007 scopus 로고    scopus 로고
    • Hemodynamic and catecholamine responses during tracheal intubation using a lightwand device (Trachlight) in elderly patients with hypertension
    • Kanaide M., Fukusaki M., Tamura S., Takada M., Miyako M., Sumikawa K. Hemodynamic and catecholamine responses during tracheal intubation using a lightwand device (Trachlight) in elderly patients with hypertension. J Anesth 2003, 17:161-165.
    • (2003) J Anesth , vol.17 , pp. 161-165
    • Kanaide, M.1    Fukusaki, M.2    Tamura, S.3    Takada, M.4    Miyako, M.5    Sumikawa, K.6
  • 7
    • 80052524437 scopus 로고    scopus 로고
    • Comparison between the hemodynamic parameters of rigid laryngoscopy and lighted stylet in patients with coronariopathies
    • Salgado F., Cordeiro V.H., Mota S., Prota M., López M.N., De Lara R.A. Comparison between the hemodynamic parameters of rigid laryngoscopy and lighted stylet in patients with coronariopathies. Rev Bras Anestesiol 2011, 61:447-455.
    • (2011) Rev Bras Anestesiol , vol.61 , pp. 447-455
    • Salgado, F.1    Cordeiro, V.H.2    Mota, S.3    Prota, M.4    López, M.N.5    De Lara, R.A.6
  • 9
    • 0032854849 scopus 로고    scopus 로고
    • Optimal length and angle of a new lightwand device (Trachlight)
    • Nishiyama T., Matsukawa T., Hanaoka K. Optimal length and angle of a new lightwand device (Trachlight). J Clin Anesth 1999, 11:332-335.
    • (1999) J Clin Anesth , vol.11 , pp. 332-335
    • Nishiyama, T.1    Matsukawa, T.2    Hanaoka, K.3
  • 11
    • 33748616557 scopus 로고    scopus 로고
    • Clinical experience of tracheal intubation using Trachlight in patients with unsutable dentition
    • Sugiyama T., Hayashi H., Amano M. Clinical experience of tracheal intubation using Trachlight in patients with unsutable dentition. Anestesiology 2006, 55:999-1001.
    • (2006) Anestesiology , vol.55 , pp. 999-1001
    • Sugiyama, T.1    Hayashi, H.2    Amano, M.3
  • 12
    • 41349096945 scopus 로고    scopus 로고
    • The importance of increased neck circumference to intubation difficulties in obese patients
    • González H., Minville V., Delanoue K., Mazerolles M., Concina D., Fourcade O. The importance of increased neck circumference to intubation difficulties in obese patients. Anesth Analg 2008, 106:1132-1136.
    • (2008) Anesth Analg , vol.106 , pp. 1132-1136
    • González, H.1    Minville, V.2    Delanoue, K.3    Mazerolles, M.4    Concina, D.5    Fourcade, O.6
  • 13
    • 0036763945 scopus 로고    scopus 로고
    • Effectiveness of lightwand (Trachlight) intubation by 1st year anesthesia residents
    • Amornyotin S., Sanansilp V., Amornyien V., Tirawat P. Effectiveness of lightwand (Trachlight) intubation by 1st year anesthesia residents. J Med Assoc Thai 2002, 85(Suppl. 3):S963-S968.
    • (2002) J Med Assoc Thai , vol.85 , Issue.SUPPL. 3
    • Amornyotin, S.1    Sanansilp, V.2    Amornyien, V.3    Tirawat, P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.