메뉴 건너뛰기




Volumn 11, Issue 4, 1999, Pages 332-335

Optimal length and angle of a new lightwand device (Trachlight(TM))

Author keywords

Intubation; Lightwand; Obesity; Tracheal; Transillumination

Indexed keywords

ADULT; AGED; ANESTHESIOLOGICAL TECHNIQUES; ARTICLE; ENDOTRACHEAL INTUBATION; FEMALE; HUMAN; ILLUMINATION; INTUBATION; MAJOR CLINICAL STUDY; MALE; OBESITY; PRIORITY JOURNAL; TRACHEA;

EID: 0032854849     PISSN: 09528180     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0952-8180(99)00056-2     Document Type: Article
Times cited : (16)

References (8)
  • 2
    • 0029829842 scopus 로고    scopus 로고
    • Simulated difficult intubation. Comparison of the gum elastic bougie and the stylet
    • Gataure P.S., Vaughan R.S., Latto I.P. Simulated difficult intubation. Comparison of the gum elastic bougie and the stylet. Anaesthesia. 51:1996;935-938.
    • (1996) Anaesthesia , vol.51 , pp. 935-938
    • Gataure, P.S.1    Vaughan, R.S.2    Latto, I.P.3
  • 3
    • 0023698649 scopus 로고
    • Lightwand intubation in children with abnormal upper airways
    • Holzman R.S., Nargozian C.D., Florence F.B. Lightwand intubation in children with abnormal upper airways. Anesthesiology. 69:1988;784-787.
    • (1988) Anesthesiology , vol.69 , pp. 784-787
    • Holzman, R.S.1    Nargozian, C.D.2    Florence, F.B.3
  • 4
    • 0024584087 scopus 로고
    • Transilluminated tracheal intubation
    • Ainsworth Q.P., Howells T.H. Transilluminated tracheal intubation. Br J Anaesth. 62:1989;494-497.
    • (1989) Br J Anaesth , vol.62 , pp. 494-497
    • Ainsworth, Q.P.1    Howells, T.H.2
  • 5
    • 0029116439 scopus 로고
    • Lightwand intubation: I. A new lightwand device
    • Hung O.R., Stewart R.D. Lightwand intubation: I. A new lightwand device. Can J Anaesth. 42:1995;820-825.
    • (1995) Can J Anaesth , vol.42 , pp. 820-825
    • Hung, O.R.1    Stewart, R.D.2
  • 6
    • 0029142933 scopus 로고
    • Lightwand intubation: II. Clinical trial of a new lightwand for tracheal intubation in patients with difficult airways
    • Hung O.R., Pytka S., Morris I., Murphy M., Stewart R.D. Lightwand intubation: II. Clinical trial of a new lightwand for tracheal intubation in patients with difficult airways. Can J Anaesth. 42:1995;826-830.
    • (1995) Can J Anaesth , vol.42 , pp. 826-830
    • Hung, O.R.1    Pytka, S.2    Morris, I.3    Murphy, M.4    Stewart, R.D.5
  • 8
    • 0029050960 scopus 로고
    • Clinical trial of a new lightwand device (Trachlight) to intubate the trachea
    • Hung O.R., Pytka S., Morris I., et al. Clinical trial of a new lightwand device (Trachlight) to intubate the trachea. Anesthesiology. 83:1995;509-514.
    • (1995) Anesthesiology , vol.83 , pp. 509-514
    • Hung, O.R.1    Pytka, S.2    Morris, I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.