메뉴 건너뛰기




Volumn 186, Issue , 2013, Pages 580-588

Non-dispersive infra-red (NDIR) measurement of carbon dioxide at 4.2 μm in a compact and optically efficient sensor

Author keywords

Carbon dioxide; Gas detection; NDIR; Non dispersive infra red; Optical absorption

Indexed keywords

DETECTOR ELEMENTS; EMITTED RADIATION; GAS DETECTION; LIMIT OF DETECTION; MOULDING TECHNOLOGY; NDIR; OPTICAL PATH LENGTHS; OPTICAL THROUGHPUT;

EID: 84880384851     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2013.06.006     Document Type: Article
Times cited : (180)

References (32)
  • 2
    • 84861934931 scopus 로고    scopus 로고
    • National Building Controls Information Program NBCIP Ankeny, IA, USA
    • 2) Transmitters 2009 NBCIP Ankeny, IA, USA
    • (2009) 2) Transmitters
  • 3
    • 77954822879 scopus 로고    scopus 로고
    • Metal oxide semi-conductor gas sensors in environmental monitoring
    • G.F. Fine, L.M. Cavanagh, A. Afonja, and R. Binions Metal oxide semi-conductor gas sensors in environmental monitoring Sensors 10 2010 5469 5502
    • (2010) Sensors , vol.10 , pp. 5469-5502
    • Fine, G.F.1    Cavanagh, L.M.2    Afonja, A.3    Binions, R.4
  • 14
    • 33745171390 scopus 로고    scopus 로고
    • High-luminosity multipass cell for infrared imaging spectroscopy
    • DOI 10.1364/AO.45.002805
    • R. Viola High-luminosity multipass cell for infrared imaging spectroscopy Applied Optics 45 2006 2805 2809 (Pubitemid 43891997)
    • (2006) Applied Optics , vol.45 , Issue.12 , pp. 2805-2809
    • Viola, R.1
  • 21
    • 84861948601 scopus 로고    scopus 로고
    • Gilway Technical Lamp Inc., Gilway Woburn, MA, USA
    • Gilway Technical Lamp Inc. Engineering Catalogue 168 1999 Gilway Woburn, MA, USA
    • (1999) Engineering Catalogue 168
  • 28
    • 84861940977 scopus 로고    scopus 로고
    • A low cost, optically efficient carbon dioxide sensor based on nondispersive infra-red (NDIR) measurement at 4.2 μm
    • J. Hodgkinson, R. Smith, W.O. Ho, J.R. Saffell, and R.P. Tatam A low cost, optically efficient carbon dioxide sensor based on nondispersive infra-red (NDIR) measurement at 4.2 μm Proceedings of SPIE 8349 2012 8349 8445
    • (2012) Proceedings of SPIE , vol.8349 , pp. 8349-8445
    • Hodgkinson, J.1    Smith, R.2    Ho, W.O.3    Saffell, J.R.4    Tatam, R.P.5
  • 29
    • 84880369312 scopus 로고    scopus 로고
    • Mathcad version 14, PTC, Inc. Needham, MA, USA
    • Mathcad version 14 Mathematical Analysis Software package 2007 PTC, Inc. Needham, MA, USA
    • (2007) Mathematical Analysis Software Package
  • 30
    • 0000722695 scopus 로고
    • The limits of signal averaging in atmospheric trace-gas monitoring by tunable diode-laser absorption spectroscopy (TDLAS)
    • P. Werle, R. Mücke, and F. Slemr The limits of signal averaging in atmospheric trace-gas monitoring by tunable diode-laser absorption spectroscopy (TDLAS) Applied Physics B 57 1993 131 139
    • (1993) Applied Physics B , vol.57 , pp. 131-139
    • Werle, P.1    Mücke, R.2    Slemr, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.