메뉴 건너뛰기




Volumn 19, Issue 4, 2013, Pages 914-918

In situ study of live specimens in an environmental scanning electron microscope

Author keywords

High pressure environment; Hydration system; In situ observation; Live biological sample; Methodology; Monte Carlo simulation

Indexed keywords

WATER;

EID: 84880288136     PISSN: 14319276     EISSN: 14358115     Source Type: Journal    
DOI: 10.1017/S1431927613000603     Document Type: Conference Paper
Times cited : (32)

References (31)
  • 3
    • 0028199978 scopus 로고
    • Minimizing sample evaporation in the environmental scanning electron microscope
    • Cameron, R.E. & Donald, A.M. (1994).Minimizing sample evaporation in the environmental scanning electron microscope. J Microsc 173, 227-237.
    • (1994) J Microsc , vol.173 , pp. 227-237
    • Cameron, R.E.1    Donald, A.M.2
  • 4
    • 84981414214 scopus 로고
    • The examination of fresh or living plant material in an environmental scanning electron microscope
    • Danilatos, G.D. (1981a). The examination of fresh or living plant material in an environmental scanning electron microscope. J Microsc 121, 235-238.
    • (1981) J Microsc , vol.121 , pp. 235-238
    • Danilatos, G.D.1
  • 5
    • 84983960794 scopus 로고
    • Design and construction of an atmospheric or environmental SEM (part 1)
    • Danilatos, G.D. (1981b). Design and construction of an atmospheric or environmental SEM (part 1). Scanning 4, 9-20.
    • (1981) Scanning , vol.4 , pp. 9-20
    • Danilatos, G.D.1
  • 7
    • 84858158029 scopus 로고    scopus 로고
    • Velocity and ejector-jet assisted differential pumping: Novel design stages for environmental SEM
    • Danilatos, G.D. (2012). Velocity and ejector-jet assisted differential pumping: Novel design stages for environmental SEM. Micron 43, 600-611.
    • (2012) Micron , vol.43 , pp. 600-611
    • Danilatos, G.D.1
  • 8
    • 0020329997 scopus 로고
    • The environmental scanning electron microscope and its applications
    • Danilatos, G.D. & Postle, R. (1982). The environmental scanning electron microscope and its applications. Scan Electron Microsc 1982, 1-16.
    • (1982) Scan Electron Microsc , vol.1982 , pp. 1-16
    • Danilatos, G.D.1    Postle, R.2
  • 9
    • 0018307727 scopus 로고
    • Principles of scanning electron microscopy at high specimen pressures
    • Danilatos, G.D. & Robinson, V.N.E. (1979). Principles of scanning electron microscopy at high specimen pressures. Scanning 2, 72-82.
    • (1979) Scanning , vol.2 , pp. 72-82
    • Danilatos, G.D.1    Robinson, V.N.E.2
  • 10
    • 80755135549 scopus 로고    scopus 로고
    • Electron microscopy of specimens in liquid
    • De Jonge, N. & Ross, F.M. (2011). Electron microscopy of specimens in liquid. Nat Nanotech 6, 695-704.
    • (2011) Nat Nanotech , vol.6 , pp. 695-704
    • De Jonge, N.1    Ross, F.M.2
  • 11
    • 0042285021 scopus 로고    scopus 로고
    • The use of environmental scanning electron microscopy for imaging wet and insulating materials
    • Donald, A.M. (2003). The use of environmental scanning electron microscopy for imaging wet and insulating materials. Nat Mater 2, 511-516.
    • (2003) Nat Mater , vol.2 , pp. 511-516
    • Donald, A.M.1
  • 12
    • 36149054260 scopus 로고
    • Wide-band detector for micro-microampere low-energy electron currents
    • Everhart, T.E. & Thornley, R.F.M. (1960). Wide-band detector for micro-microampere low-energy electron currents, J Sci Instrum 37, 246-248.
    • (1960) J Sci Instrum , vol.37 , pp. 246-248
    • Everhart, T.E.1    Thornley, R.F.M.2
  • 13
    • 0344133233 scopus 로고
    • Injection of liquid into environmental cell for in situ observations
    • Fukushima, K., Ishikawa, A. & Fukami, A. (1985). Injection of liquid into environmental cell for in situ observations. J Electron Microsc 34, 47-51.
    • (1985) J Electron Microsc , vol.34 , pp. 47-51
    • Fukushima, K.1    Ishikawa, A.2    Fukami, A.3
  • 14
    • 0001526936 scopus 로고
    • High temperature gas reaction specimen chamber for an electron microscope
    • Hashimoto, H., Naiki, T., Eto, T. & Fujiwara, K. (1968). High temperature gas reaction specimen chamber for an electron microscope. Jpn J Appl Phys 7, 946-953.
    • (1968) Jpn J Appl Phys , vol.7 , pp. 946-953
    • Hashimoto, H.1    Naiki, T.2    Eto, T.3    Fujiwara, K.4
  • 17
    • 77955763807 scopus 로고    scopus 로고
    • Scintillation SE detector for variable pressure scanning electron microscopes
    • Jirák, J., Neděla, V., Černoch, P., Čudek, P. & Runštuk, J. (2010). Scintillation SE detector for variable pressure scanning electron microscopes. J Microsc 239, 233-238.
    • (2010) J Microsc , vol.239 , pp. 233-238
    • Jirák, J.1    Neděla, V.2    Černoch, P.3    Čudek, P.4    Runštuk, J.5
  • 18
    • 33847161340 scopus 로고
    • The environmental control stage
    • Lane,W.C. (1970). The environmental control stage. Scan Electron Microsc 1970, 43-48.
    • (1970) Scan Electron Microsc , vol.1970 , pp. 43-48
    • Lane, W.C.1
  • 19
    • 77954710868 scopus 로고    scopus 로고
    • ESEM imaging of dynamic biological processes: The closure of stomatal pores
    • McGregor, J.E. & Donald, A.M. (2010). ESEM imaging of dynamic biological processes: The closure of stomatal pores. J Microsc 239, 135-141.
    • (2010) J Microsc , vol.239 , pp. 135-141
    • McGregor, J.E.1    Donald, A.M.2
  • 20
    • 33847165777 scopus 로고    scopus 로고
    • Methods for additive hydration allowing observation of fully hydrated state of wet samples in environmental SEM
    • Neděla, V. (2007).Methods for additive hydration allowing observation of fully hydrated state of wet samples in environmental SEM. Microsc Res Tech 70, 95-100.
    • (2007) Microsc Res Tech , vol.70 , pp. 95-100
    • Neděla, V.1
  • 21
    • 72349088450 scopus 로고    scopus 로고
    • Controlled dehydration of a biological sample using an alternative form of environmental SEM
    • Neděla, V. (2010). Controlled dehydration of a biological sample using an alternative form of environmental SEM.J Microsc 237, 7-11.
    • (2010) J Microsc , vol.237 , pp. 7-11
    • Neděla, V.1
  • 23
    • 79958188896 scopus 로고    scopus 로고
    • Comparison of calculated, simulated and measured signal amplification in a variable pressure SEM
    • Neděla, V., Konvalina, I., Lencová, B. & Zlámal, J. (2011). Comparison of calculated, simulated and measured signal amplification in a variable pressure SEM. Nucl Instrum Methods Phys Res A 645, 79-83.
    • (2011) Nucl Instrum Methods Phys Res A , vol.645 , pp. 79-83
    • Neděla, V.1    Konvalina, I.2    Lencová, B.3    Zlámal, J.4
  • 24
    • 79959673483 scopus 로고    scopus 로고
    • Fully hydrated yeast cells imaged with electron microscopy
    • Peckys, D.B., Mazur, P., Gould, K.L. & Jonge, N. (2011). Fully hydrated yeast cells imaged with electron microscopy. Biophys J 100, 2522-2539.
    • (2011) Biophys J , vol.100 , pp. 2522-2539
    • Peckys, D.B.1    Mazur, P.2    Gould, K.L.3    Jonge, N.4
  • 26
    • 0016694791 scopus 로고
    • A wet stage modification to a scanning electron microscope
    • Robinson, V.N.E. (1975). A wet stage modification to a scanning electron microscope. J Microsc 103, 71-77.
    • (1975) J Microsc , vol.103 , pp. 71-77
    • Robinson V. .N., .E.1
  • 28
    • 0035690639 scopus 로고    scopus 로고
    • Radiation damage of water in environmental scanning electron microscopy
    • Royall, C.P., Thiel, B.L. & Donald, A.M. (2001). Radiation damage of water in environmental scanning electron microscopy. J Microsc 204, 185-195.
    • (2001) J Microsc , vol.204 , pp. 185-195
    • Royall, C.P.1    Thiel, B.L.2    Donald, A.M.3
  • 29
    • 34347103405 scopus 로고
    • Beitrag zur übermikroskopischen Abbildung bei höheren Drucken
    • Ruska, E. (1942). Beitrag zur übermikroskopischen Abbildung bei höheren Drucken. Kolloid 100, 212-219.
    • (1942) Kolloid , vol.100 , pp. 212-219
    • Ruska, E.1
  • 30
    • 58449134498 scopus 로고    scopus 로고
    • Investigating biological ultrastructure using environmental scanning electron microscopy (ESEM)
    • Méndez-Vilas, A. (Ed.), Spain: Formatex Research Center
    • Stokes, D.J. (2003). Investigating biological ultrastructure using environmental scanning electron microscopy (ESEM). In Science, Technology and Education of Microscopy an Overview, Méndez-Vilas, A. (Ed.), pp. 564-570. Spain: Formatex Research Center.
    • (2003) Science, Technology and Education of Microscopy An Overview , pp. 564-570
    • Stokes, D.J.1
  • 31
    • 84894898452 scopus 로고    scopus 로고
    • Progress in the study of biological specimens using ESEM
    • Stokes, D.J. (2006). Progress in the study of biological specimens using ESEM. Infocus 2, 64-72.
    • (2006) Infocus , vol.2 , pp. 64-72
    • Stokes, D.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.