-
1
-
-
0242407676
-
Principles of electrosurgery
-
M.V. Sivak, 2nd ed. WB Saunders Philadelphia (Pa)
-
R. Tucker Principles of electrosurgery M.V. Sivak, Gastroenterologic endoscopy 2nd ed. 2000 WB Saunders Philadelphia (Pa) 125 135
-
(2000)
Gastroenterologic Endoscopy
, pp. 125-135
-
-
Tucker, R.1
-
2
-
-
0015816615
-
High frequency currents in endoscopy: A review of principles and precautions
-
L.E. Curtiss High frequency currents in endoscopy: a review of principles and precautions Gastrointest Endosc 20 1973 9 12
-
(1973)
Gastrointest Endosc
, vol.20
, pp. 9-12
-
-
Curtiss, L.E.1
-
3
-
-
77956318778
-
European Society of Gastrointestinal Endoscopy (ESGE) guideline: The use of electrosurgical units
-
J.F. Rey, U. Beilenhoff, and C.S. Neumann European Society of Gastrointestinal Endoscopy (ESGE) guideline: the use of electrosurgical units Endoscopy 42 2010 764 772
-
(2010)
Endoscopy
, vol.42
, pp. 764-772
-
-
Rey, J.F.1
Beilenhoff, U.2
Neumann, C.S.3
-
4
-
-
66949133192
-
Electrosurgery in gastrointestinal endoscopy: Principles to practice
-
M.L. Morris, R.D. Tucker, and T.H. Baron Electrosurgery in gastrointestinal endoscopy: principles to practice Am J Gastroenterol 104 2009 1563 1574
-
(2009)
Am J Gastroenterol
, vol.104
, pp. 1563-1574
-
-
Morris, M.L.1
Tucker, R.D.2
Baron, T.H.3
-
5
-
-
0020048125
-
Endoscopic applications of electrosurgery: A review of basic principles
-
D.E. Barlow Endoscopic applications of electrosurgery: a review of basic principles Gastrointest Endosc 28 1982 73 76
-
(1982)
Gastrointest Endosc
, vol.28
, pp. 73-76
-
-
Barlow, D.E.1
-
7
-
-
84880261393
-
Electrosurgery in Therapeutic Endoscopy
-
G.G. Ginsberg, M.L. Kochman, I.D. Norton, 2nd ed. Saunders/Elsevier St. Louis (Mo)
-
M. Morris, and I.D. Norton Electrosurgery in Therapeutic Endoscopy G.G. Ginsberg, M.L. Kochman, I.D. Norton, Clinical gastrointestinal endoscopy 2nd ed. 2011 Saunders/Elsevier St. Louis (Mo) 69 77
-
(2011)
Clinical Gastrointestinal Endoscopy
, pp. 69-77
-
-
Morris, M.1
Norton, I.D.2
-
8
-
-
1542410050
-
A comparison of depth of tissue injury caused by different modes of electrosurgical current in a pig colon model
-
A. Chino, T. Karasawa, and N. Uragami A comparison of depth of tissue injury caused by different modes of electrosurgical current in a pig colon model Gastrointest Endosc 59 2004 374 379
-
(2004)
Gastrointest Endosc
, vol.59
, pp. 374-379
-
-
Chino, A.1
Karasawa, T.2
Uragami, N.3
-
10
-
-
0036038551
-
Endoscopic resection of large sessile colonic polyps by specialist and non-specialist endoscopists
-
J.C. Brooker, B.P. Saunders, and S.G. Shah Endoscopic resection of large sessile colonic polyps by specialist and non-specialist endoscopists Br J Surg 89 2002 1020 1024
-
(2002)
Br J Surg
, vol.89
, pp. 1020-1024
-
-
Brooker, J.C.1
Saunders, B.P.2
Shah, S.G.3
-
11
-
-
0026704886
-
Colonoscopic snare polypectomy: Analysis of 1485 resections comparing two types of current
-
A. Van Gossum, A. Cozzoli, and M. Adler Colonoscopic snare polypectomy: analysis of 1485 resections comparing two types of current Gastrointest Endosc 38 1992 472 475
-
(1992)
Gastrointest Endosc
, vol.38
, pp. 472-475
-
-
Van Gossum, A.1
Cozzoli, A.2
Adler, M.3
-
12
-
-
33744831779
-
Risk factors for immediate postpolypectomy bleeding of the colon: A multicenter study
-
H.S. Kim, T.I. Kim, and W.H. Kim Risk factors for immediate postpolypectomy bleeding of the colon: a multicenter study Am J Gastroenterol 101 2006 1333 1341
-
(2006)
Am J Gastroenterol
, vol.101
, pp. 1333-1341
-
-
Kim, H.S.1
Kim, T.I.2
Kim, W.H.3
-
13
-
-
33748376271
-
Diagnostic quality of: Polyps resected by snare polypectomy: Does the type of electrosurgical current used matter?
-
L.C. Fry, A.J. Lazenby, and I. Mikolaenko Diagnostic quality of: polyps resected by snare polypectomy: does the type of electrosurgical current used matter? Am J Gastroenterol 101 2006 2123 2127
-
(2006)
Am J Gastroenterol
, vol.101
, pp. 2123-2127
-
-
Fry, L.C.1
Lazenby, A.J.2
Mikolaenko, I.3
-
14
-
-
0031906693
-
Pure cut electrocautery current for sphincterotomy causes less post-procedure pancreatitis than blended current
-
G.H. Elta, J.L. Barnett, and R.T. Wille Pure cut electrocautery current for sphincterotomy causes less post-procedure pancreatitis than blended current Gastrointest Endosc 47 1998 149 153
-
(1998)
Gastrointest Endosc
, vol.47
, pp. 149-153
-
-
Elta, G.H.1
Barnett, J.L.2
Wille, R.T.3
-
15
-
-
4744345389
-
Endoscopic sphincterotomy by using pure-cut electrosurgical current and the risk of post-ERCP pancreatitis: A prospective randomized trial
-
D.G. Macintosh, J. Love, and N.S. Abraham Endoscopic sphincterotomy by using pure-cut electrosurgical current and the risk of post-ERCP pancreatitis: a prospective randomized trial Gastrointest Endosc 60 2004 551 556
-
(2004)
Gastrointest Endosc
, vol.60
, pp. 551-556
-
-
Macintosh, D.G.1
Love, J.2
Abraham, N.S.3
-
16
-
-
0034760420
-
First cut, then blend: An electrocautery technique affecting bleeding at sphincterotomy
-
A. Gorelick, M. Cannon, and J. Barnett First cut, then blend: an electrocautery technique affecting bleeding at sphincterotomy Endoscopy 33 2001 976 980
-
(2001)
Endoscopy
, vol.33
, pp. 976-980
-
-
Gorelick, A.1
Cannon, M.2
Barnett, J.3
-
17
-
-
0037327180
-
A comparative study of postendoscopic sphincterotomy complications with various types of electrosurgical current in patients with choledocholithiasis
-
G. Stefanidis, G. Karamanolis, and N. Viazis A comparative study of postendoscopic sphincterotomy complications with various types of electrosurgical current in patients with choledocholithiasis Gastrointest Endosc 57 2003 192 197
-
(2003)
Gastrointest Endosc
, vol.57
, pp. 192-197
-
-
Stefanidis, G.1
Karamanolis, G.2
Viazis, N.3
-
18
-
-
24444452677
-
Complications of endoscopic sphincterotomy (ES): The role of the electrocautery unit
-
[abstract]
-
F.J. Totta, J. David, and F. Ramirez Complications of endoscopic sphincterotomy (ES): the role of the electrocautery unit [abstract] Gastrointest Endosc 55 2002 AB155
-
(2002)
Gastrointest Endosc
, vol.55
, pp. 155
-
-
Totta, F.J.1
David, J.2
Ramirez, F.3
-
19
-
-
33646451560
-
Safety advantage of endocut mode over endoscopic sphincterotomy for choledocholithiasis
-
H. Akiho, Y. Sumida, and K. Akahoshi Safety advantage of endocut mode over endoscopic sphincterotomy for choledocholithiasis World J Gastroenterol 12 2006 2086 2088
-
(2006)
World J Gastroenterol
, vol.12
, pp. 2086-2088
-
-
Akiho, H.1
Sumida, Y.2
Akahoshi, K.3
-
20
-
-
26244465065
-
A randomized trial of endoscopic biliary sphincterotomy using pure-cut versus combined cut and coagulation waveforms
-
I.D. Norton, B.T. Petersen, and J. Bosco A randomized trial of endoscopic biliary sphincterotomy using pure-cut versus combined cut and coagulation waveforms Clin Gastroenterol Hepatol 3 2005 1029 1033
-
(2005)
Clin Gastroenterol Hepatol
, vol.3
, pp. 1029-1033
-
-
Norton, I.D.1
Petersen, B.T.2
Bosco, J.3
-
21
-
-
12844272459
-
Post-sphincterotomy bleeding after the introduction of microprocessor-controlled electrosurgery: Does the new technology make the difference?
-
R.F. Perini, R. Sadurski, and P.B. Cotton Post-sphincterotomy bleeding after the introduction of microprocessor-controlled electrosurgery: does the new technology make the difference? Gastrointest Endosc 61 2005 53 57
-
(2005)
Gastrointest Endosc
, vol.61
, pp. 53-57
-
-
Perini, R.F.1
Sadurski, R.2
Cotton, P.B.3
-
22
-
-
8344291071
-
Randomized control trial of EST with either endocut mode or conventional pure cut mode
-
[abstract]
-
M. Kida, H. Kikuchi, and M. Araki Randomized control trial of EST with either endocut mode or conventional pure cut mode [abstract] Gastrointest Endosc 59 2004 P201
-
(2004)
Gastrointest Endosc
, vol.59
, pp. 201
-
-
Kida, M.1
Kikuchi, H.2
Araki, M.3
-
23
-
-
33646448031
-
"endocut" technique versus pure cutting current for endoscopic sphincterotomy: A comparison of complication rates
-
[abstract]
-
W. Ellahi, F.E. Kasmin, and S.A. Cohen "Endocut" technique versus pure cutting current for endoscopic sphincterotomy: a comparison of complication rates [abstract] Gastrointest Endosc 53 2001 AB95
-
(2001)
Gastrointest Endosc
, vol.53
, pp. 95
-
-
Ellahi, W.1
Kasmin, F.E.2
Cohen, S.A.3
-
24
-
-
0031878378
-
A new HF current generator with automatically controlled system (Endocut mode) for endoscopic sphincterotomy-preliminary experience
-
A. Kohler, M. Maier, and C. Benz A new HF current generator with automatically controlled system (Endocut mode) for endoscopic sphincterotomy-preliminary experience Endoscopy 30 1998 351 355
-
(1998)
Endoscopy
, vol.30
, pp. 351-355
-
-
Kohler, A.1
Maier, M.2
Benz, C.3
-
25
-
-
0027102124
-
Status evaluation: Hot biopsy forceps. American Society for Gastrointestinal Endoscopy. Technology Assessment Committee
-
D.A. Gilbert, A.J. DiMarino, and D.M. Jensen Status evaluation: hot biopsy forceps. American Society for Gastrointestinal Endoscopy. Technology Assessment Committee Gastrointest Endosc 38 1992 753 756
-
(1992)
Gastrointest Endosc
, vol.38
, pp. 753-756
-
-
Gilbert, D.A.1
Dimarino, A.J.2
Jensen, D.M.3
-
26
-
-
0032107819
-
Technology assessment status evaluation: Bipolar and multipolar accessories, February 1996
-
D.L. Carr-Locke, F.H. al-Kawas, and M.S. Branch Technology assessment status evaluation: bipolar and multipolar accessories, February 1996 Gastroenterol Nurs 21 1998 187 189
-
(1998)
Gastroenterol Nurs
, vol.21
, pp. 187-189
-
-
Carr-Locke, D.L.1
Al-Kawas, F.H.2
Branch, M.S.3
-
29
-
-
56349096427
-
Mucosal ablation devices
-
American Society for Gastrointestinal Endoscopy Technology C
-
American Society for Gastrointestinal Endoscopy Technology C Mucosal ablation devices Gastrointest Endosc 68 2008 1031 1042
-
(2008)
Gastrointest Endosc
, vol.68
, pp. 1031-1042
-
-
-
30
-
-
84861484577
-
The role of endoscopy in the management of acute non-variceal upper GI bleeding
-
J.H. Hwang, D.A. Fisher, and T. Ben-Menachem The role of endoscopy in the management of acute non-variceal upper GI bleeding Gastrointest Endosc 75 2012 1132 1138
-
(2012)
Gastrointest Endosc
, vol.75
, pp. 1132-1138
-
-
Hwang, J.H.1
Fisher, D.A.2
Ben-Menachem, T.3
-
31
-
-
27144457401
-
ASGE Guideline: The role of endoscopy in the management of variceal hemorrhage, updated July 2005
-
W. Qureshi, D.G. Adler, and R. Davila ASGE Guideline: the role of endoscopy in the management of variceal hemorrhage, updated July 2005 Gastrointest Endosc 62 2005 651 655
-
(2005)
Gastrointest Endosc
, vol.62
, pp. 651-655
-
-
Qureshi, W.1
Adler, D.G.2
Davila, R.3
-
32
-
-
27144512124
-
ASGE Guideline: The role of endoscopy in the patient with lower-GI bleeding
-
R.E. Davila, E. Rajan, and D.G. Adler ASGE Guideline: the role of endoscopy in the patient with lower-GI bleeding Gastrointest Endosc 62 2005 656 660
-
(2005)
Gastrointest Endosc
, vol.62
, pp. 656-660
-
-
Davila, R.E.1
Rajan, E.2
Adler, D.G.3
-
33
-
-
45249114642
-
Endoscopic mucosal resection and endoscopic submucosal dissection
-
S.V. Kantsevoy, D.G. Adler, and J. Conway Endoscopic mucosal resection and endoscopic submucosal dissection Gastrointest Endosc 68 2008 11 18
-
(2008)
Gastrointest Endosc
, vol.68
, pp. 11-18
-
-
Kantsevoy, S.V.1
Adler, D.G.2
Conway, J.3
-
34
-
-
77957303474
-
Current practice with endoscopic submucosal dissection in Europe: Position statement from a panel of experts
-
P.H. Deprez, J.J. Bergman, and S. Meisner Current practice with endoscopic submucosal dissection in Europe: position statement from a panel of experts Endoscopy 42 2010 853 858
-
(2010)
Endoscopy
, vol.42
, pp. 853-858
-
-
Deprez, P.H.1
Bergman, J.J.2
Meisner, S.3
-
35
-
-
0035650578
-
Technology status evaluation report. Endoscopic hemostatic devices. May 2001
-
D.B. Nelson, A.N. Barkun, and K.P. Block Technology status evaluation report. Endoscopic hemostatic devices. May 2001 Gastrointest Endosc 54 2001 833 840
-
(2001)
Gastrointest Endosc
, vol.54
, pp. 833-840
-
-
Nelson, D.B.1
Barkun, A.N.2
Block, K.P.3
-
36
-
-
79958149835
-
Radiofrequency ablation for nondysplastic Barrett's esophagus: To treat or not to treat?
-
discussion 2132
-
G. Fernandez-Esparrach, and J. Panes Radiofrequency ablation for nondysplastic Barrett's esophagus: to treat or not to treat? Gastroenterology 140 2011 2130 2132 discussion 2132
-
(2011)
Gastroenterology
, vol.140
, pp. 2130-2132
-
-
Fernandez-Esparrach, G.1
Panes, J.2
-
37
-
-
80051483372
-
Durability of radiofrequency ablation in Barrett's esophagus with dysplasia
-
N.J. Shaheen, B.F. Overholt, and R.E. Sampliner Durability of radiofrequency ablation in Barrett's esophagus with dysplasia Gastroenterology 141 2011 460 468
-
(2011)
Gastroenterology
, vol.141
, pp. 460-468
-
-
Shaheen, N.J.1
Overholt, B.F.2
Sampliner, R.E.3
-
38
-
-
77957307078
-
Endoscopic radiofrequency ablation for Barrett's esophagus: 5-year outcomes from a prospective multicenter trial
-
D.E. Fleischer, B.F. Overholt, and V.K. Sharma Endoscopic radiofrequency ablation for Barrett's esophagus: 5-year outcomes from a prospective multicenter trial Endoscopy 42 2010 781 789
-
(2010)
Endoscopy
, vol.42
, pp. 781-789
-
-
Fleischer, D.E.1
Overholt, B.F.2
Sharma, V.K.3
-
39
-
-
34247341812
-
Commentary on clinical applications of argon plasma coagulation in endoscopy
-
author reply 130
-
R. Tucker Commentary on clinical applications of argon plasma coagulation in endoscopy Gastroenterol Nurs 30 2007 129 130 author reply 130
-
(2007)
Gastroenterol Nurs
, vol.30
, pp. 129-130
-
-
Tucker, R.1
-
40
-
-
0021256836
-
Demodulated low frequency currents from electrosurgical procedures
-
R.D. Tucker, O.H. Schmitt, and C.E. Sievert Demodulated low frequency currents from electrosurgical procedures Surg Gynecol Obstet 159 1984 39 43
-
(1984)
Surg Gynecol Obstet
, vol.159
, pp. 39-43
-
-
Tucker, R.D.1
Schmitt, O.H.2
Sievert, C.E.3
-
41
-
-
0028032454
-
Technology Assessment: Electrocautery use in patients with implanted cardiac devices
-
M.B. Kimmey, F.H. Al-Kawas, and D.A. Burnett Technology Assessment: Electrocautery use in patients with implanted cardiac devices Gastrointest Endosc 40 1994 794
-
(1994)
Gastrointest Endosc
, vol.40
, pp. 794
-
-
Kimmey, M.B.1
Al-Kawas, F.H.2
Burnett, D.A.3
-
42
-
-
33947389713
-
Endoscopy in patients with implanted electronic devices
-
B.T. Petersen, N. Hussain, and J.E. Marine Endoscopy in patients with implanted electronic devices Gastrointest Endosc 65 2007 561 568
-
(2007)
Gastrointest Endosc
, vol.65
, pp. 561-568
-
-
Petersen, B.T.1
Hussain, N.2
Marine, J.E.3
|