메뉴 건너뛰기




Volumn 54, Issue SUPPL.1, 2013, Pages

Evaluation of different fiducial markers for image-guided radiotherapy and particle therapy

Author keywords

carbon ion therapy; fiducial marker; liver tumors; moving organs; raster scanning technique

Indexed keywords

CARBON; COMPUTERIZED TOMOGRAPHY; IONS; IRRADIATION; PHOTONS; PROTON BEAM THERAPY; RADIOTHERAPY; X RAY FILMS; X RAY RADIOGRAPHY;

EID: 84880203934     PISSN: 04493060     EISSN: 13499157     Source Type: Journal    
DOI: 10.1093/jrr/rrt071     Document Type: Article
Times cited : (78)

References (21)
  • 1
    • 33845372171 scopus 로고    scopus 로고
    • Advances in radio-oncology. from precision radiotherapy with photons to ion therapy with protons and carbon ions
    • Combs SE, Schulz-Ertner D, Herfarth KK et al. Advances in radio-oncology. From precision radiotherapy with photons to ion therapy with protons and carbon ions. Chirurg 2006;77:1126-32.
    • (2006) Chirurg , vol.77 , pp. 1126-1132
    • Combs, S.E.1    Schulz-Ertner, D.2    Herfarth, K.K.3
  • 2
    • 77956561901 scopus 로고    scopus 로고
    • Heidelberg Ion Therapy Center (HIT): Initial clinical experience in the first 80 patients
    • Combs SE, Ellerbrock M, Haberer T et al. Heidelberg Ion Therapy Center (HIT): Initial clinical experience in the first 80 patients. Acta Oncol 2010;49:1132-40.
    • (2010) Acta Oncol , vol.49 , pp. 1132-1140
    • Combs, S.E.1    Ellerbrock, M.2    Haberer, T.3
  • 3
    • 77950329106 scopus 로고    scopus 로고
    • Particle therapy at the Heidelberg Ion Therapy Center (HIT)-Integrated research-driven university-hospital-based radiation oncology service in Heidelberg, Germany
    • Combs SE, Jakel O, Haberer T et al. Particle therapy at the Heidelberg Ion Therapy Center (HIT)-Integrated research-driven university-hospital-based radiation oncology service in Heidelberg, Germany. Radiother Oncol 2010;95:41-4.
    • (2010) Radiother Oncol , vol.95 , pp. 41-44
    • Combs, S.E.1    Jakel, O.2    Haberer, T.3
  • 4
    • 79751525739 scopus 로고    scopus 로고
    • Phase i study evaluating the treatment of patients with hepatocellular carcinoma (HCC) with carbon ion radiotherapy: The PROMETHEUS-01 trial
    • Combs SE, Habermehl D, Ganten T et al. Phase i study evaluating the treatment of patients with hepatocellular carcinoma (HCC) with carbon ion radiotherapy: the PROMETHEUS-01 trial. BMC Cancer 2011;11:67.
    • (2011) BMC Cancer , vol.11 , pp. 67
    • Combs, S.E.1    Habermehl, D.2    Ganten, T.3
  • 5
    • 84874796373 scopus 로고    scopus 로고
    • Hypofractionated carbon ion therapy delivered with scanned ion beams for patients with hepatocellular carcinoma-feasibility and clinical response
    • Habermehl D, Debus J, Ganten T et al. Hypofractionated carbon ion therapy delivered with scanned ion beams for patients with hepatocellular carcinoma-feasibility and clinical response. Radiat Oncol 2013;8:59.
    • (2013) Radiat Oncol , vol.8 , pp. 59
    • Habermehl, D.1    Debus, J.2    Ganten, T.3
  • 6
    • 84872874385 scopus 로고    scopus 로고
    • Clinical evaluation of a commercial surface-imaging system for patient positioning in radiotherapy
    • Stieler F, Wenz F, Scherrer D et al. Clinical evaluation of a commercial surface-imaging system for patient positioning in radiotherapy. Strahlenther Onkol 2012;188:1080-4.
    • (2012) Strahlenther Onkol , vol.188 , pp. 1080-1084
    • Stieler, F.1    Wenz, F.2    Scherrer, D.3
  • 7
    • 34047245081 scopus 로고    scopus 로고
    • The influence of metal artefacts on the range of ion beams
    • Jakel O, Reiss P. The influence of metal artefacts on the range of ion beams. Phys Med Biol 2007;52:635-44.
    • (2007) Phys Med Biol , vol.52 , pp. 635-644
    • Jakel, O.1    Reiss, P.2
  • 8
    • 77956576834 scopus 로고    scopus 로고
    • Investigation of the dosimet-ric impact of a Ni-Ti fiducial marker in carbon ion and proton beams
    • Herrmann R, Carl J, Jakel O et al. Investigation of the dosimet-ric impact of a Ni-Ti fiducial marker in carbon ion and proton beams. Acta Oncol 2010;49:1160-4.
    • (2010) Acta Oncol , vol.49 , pp. 1160-1164
    • Herrmann, R.1    Carl, J.2    Jakel, O.3
  • 9
    • 34250370542 scopus 로고    scopus 로고
    • Dosimetric impact of tantalum markers used in the treatment of uveal melanoma with proton beam therapy
    • Newhauser WD, Koch NC, Fontenot JD et al. Dosimetric impact of tantalum markers used in the treatment of uveal melanoma with proton beam therapy. Phys Med Biol 2007;52:3979-90.
    • (2007) Phys Med Biol , vol.52 , pp. 3979-3990
    • Newhauser, W.D.1    Koch, N.C.2    Fontenot, J.D.3
  • 10
    • 78650074915 scopus 로고    scopus 로고
    • Dose perturbations and image artifacts caused by carbon-coated ceramic and stainless steel fiducials used in proton therapy for prostate cancer
    • Cheung J, Kudchadker RJ, Zhu XR et al. Dose perturbations and image artifacts caused by carbon-coated ceramic and stainless steel fiducials used in proton therapy for prostate cancer. Phys Med Biol 2010;55:7135-47.
    • (2010) Phys Med Biol , vol.55 , pp. 7135-7147
    • Cheung, J.1    Kudchadker, R.J.2    Zhu, X.R.3
  • 11
    • 80052263107 scopus 로고    scopus 로고
    • Combination of dose escalation with technological advances (intensity-modulated and image-guided radiotherapy) is not associated with increased morbidity for patients with prostate cancer
    • Pinkawa M, Piroth MD, Holy R et al. Combination of dose escalation with technological advances (intensity-modulated and image-guided radiotherapy) is not associated with increased morbidity for patients with prostate cancer. Strahlenther Onkol 2011;187:479-84.
    • (2011) Strahlenther Onkol , vol.187 , pp. 479-484
    • Pinkawa, M.1    Piroth, M.D.2    Holy, R.3
  • 12
    • 84892902009 scopus 로고    scopus 로고
    • PET-Bildgebung für die Protonen-und Schwerionentherapie: Hintergrund, Entwicklungen und klinische Implementierung
    • Combs SE, Haberkorn U, Debus J, Parodi K. PET-Bildgebung für die Protonen-und Schwerionentherapie: Hintergrund, Entwicklungen und klinische Implementierung. Nuklearmediziner 2011;34:93-8.
    • (2011) Nuklearmediziner , vol.34 , pp. 93-98
    • Combs, S.E.1    Haberkorn, U.2    Debus, J.3    Parodi, K.4
  • 13
    • 42449147956 scopus 로고    scopus 로고
    • Quantification of interplay effects of scanned particle beams and moving targets
    • Bert C, Grozinger SO, Rietzel E. Quantification of interplay effects of scanned particle beams and moving targets. Phys Med Biol 2008;53:2253-65.
    • (2008) Phys Med Biol , vol.53 , pp. 2253-2265
    • Bert, C.1    Grozinger, S.O.2    Rietzel, E.3
  • 14
    • 84862670986 scopus 로고    scopus 로고
    • RapidArc combined with the active breathing coordinator provides an effective and accurate approach for the radiotherapy of hepatocellular carcinoma
    • Gong GZ, Yin Y, Xing LG et al. RapidArc combined with the active breathing coordinator provides an effective and accurate approach for the radiotherapy of hepatocellular carcinoma. Strahlenther Onkol 2012;188:262-8.
    • (2012) Strahlenther Onkol , vol.188 , pp. 262-268
    • Gong, G.Z.1    Yin, Y.2    Xing, L.G.3
  • 15
    • 84865556751 scopus 로고    scopus 로고
    • Real-time tumour tracking in particle therapy: Technological developments and future perspectives
    • Riboldi M, Orecchia R, Baroni G. Real-time tumour tracking in particle therapy: technological developments and future perspectives. Lancet Oncol 2012;13:e383-91.
    • (2012) Lancet Oncol , vol.13
    • Riboldi, M.1    Orecchia, R.2    Baroni, G.3
  • 16
    • 84870385182 scopus 로고    scopus 로고
    • Ion beam therapy fundamentals, technology, clinical applications
    • Berlin; New York: Springer
    • Linz U. (ed) Ion beam therapy fundamentals, technology, clinical applications. In: Biological and Medical Physics, Biomedical Engineering. Berlin; New York: Springer, 2012.
    • (2012) Biological and Medical Physics, Biomedical Engineering
    • Linz, U.1
  • 17
    • 79961060288 scopus 로고    scopus 로고
    • Investigation of dose perturbations and the radiographic visibility of potential fiducials for proton radiation therapy of the prostate
    • Huang JY, Newhauser WD, Zhu XR et al. Investigation of dose perturbations and the radiographic visibility of potential fiducials for proton radiation therapy of the prostate. Phys Med Biol 2011;56:5287-302.
    • (2011) Phys Med Biol , vol.56 , pp. 5287-5302
    • Huang, J.Y.1    Newhauser, W.D.2    Zhu, X.R.3
  • 18
    • 84859963376 scopus 로고    scopus 로고
    • Safety and efficacy of ultrasound-guided fiducial marker implantation for CyberKnife radiation therapy
    • Kim JH, Hong SS, Park HJ et al. Safety and efficacy of ultrasound-guided fiducial marker implantation for CyberKnife radiation therapy. Korean J Radiol 2012;13:307-13.
    • (2012) Korean J Radiol , vol.13 , pp. 307-313
    • Kim, J.H.1    Hong, S.S.2    Park, H.J.3
  • 19
    • 84867314318 scopus 로고    scopus 로고
    • Liver motion during cone beam computed tomography guided stereotactic body radiation therapy
    • Park JC, Park SH, Kim JH et al. Liver motion during cone beam computed tomography guided stereotactic body radiation therapy. Med Phys 2012;39:6431-42.
    • (2012) Med Phys , vol.39 , pp. 6431-6442
    • Park, J.C.1    Park, S.H.2    Kim, J.H.3
  • 20
    • 80052072847 scopus 로고    scopus 로고
    • Treatment precision of image-guided liver SBRT using implanted fiducial markers depends on marker-tumour distance
    • Seppenwoolde Y, Wunderink W, Wunderink-van Veen SR et al. Treatment precision of image-guided liver SBRT using implanted fiducial markers depends on marker-tumour distance. Phys Med Biol 2011;56:5445-68.
    • (2011) Phys Med Biol , vol.56 , pp. 5445-5468
    • Seppenwoolde, Y.1    Wunderink, W.2    Wunderink-Van Veen, S.R.3
  • 21
    • 0030065290 scopus 로고    scopus 로고
    • The calibration of CT Hounsfield units for radiotherapy treatment planning
    • Schneider U, Pedroni E, Lomax A. The calibration of CT Hounsfield units for radiotherapy treatment planning. Phys Med Biol 1996;41:111-24.
    • (1996) Phys Med Biol , vol.41 , pp. 111-124
    • Schneider, U.1    Pedroni, E.2    Lomax, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.