Volumn 24, Issue 2, 2010, Pages 247-252

Tracheal fluid leakage in benchtop trials: Comparison of static versus dynamic ventilation model with and without lubrication

Author keywords

Aspiration; Benchtop trials; PEEP; Tracheal tube cuff

Indexed keywords

ARTICLE; BREATHING; COMPARATIVE STUDY; CONTROLLED STUDY; ENDOTRACHEAL TUBE; LUBRICATION; LUNG MODEL; POSITIVE END EXPIRATORY PRESSURE; TRACHEA;

EID: 77954537962     PISSN: 09138668     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00540-010-0871-z     Document Type: Article
Times cited : (24)

References (13)
  • 1
    • 0030962932 scopus 로고    scopus 로고
    • Leakage of fluid past the tracheal tube cuff in a benchtop model
    • Young PJ, Rollinson M, Downward G, Henderson S. Leakage of fluid past the tracheal tube cuff in a benchtop model. Br J Anaesth. 1997;78:557-562
    • (1997) Br J Anaesth , vol.78 , pp. 557-562
    • Young, P.J.1    Rollinson, M.2    Downward, G.3    Henderson, S.4
  • 2
    • 0030918175 scopus 로고    scopus 로고
    • Leakage of fluid around low-pressure tracheal tube cuffs
    • Oikkonen M, Aromaa U. Leakage of fluid around low-pressure tracheal tube cuffs. Anaesthesia. 1997;52:567-569
    • (1997) Anaesthesia , vol.52 , pp. 567-569
    • Oikkonen, M.1    Aromaa, U.2
  • 3
    • 0242677653 scopus 로고    scopus 로고
    • Fluid leakage past tracheal tube cuffs: Evaluation of the new Microcuff endotracheal tube
    • Dullenkopf A, Gerber A, Weiss M. Fluid leakage past tracheal tube cuffs: evaluation of the new Microcuff endotracheal tube. Intensive Care Med. 2003;29:1849-1853
    • (2003) Intensive Care Med. , vol.29 , pp. 1849-1853
    • Dullenkopf, A.1    Gerber, A.2    Weiss, M.3
  • 5
    • 0031775771 scopus 로고    scopus 로고
    • Evaluation of a new design of tracheal tube cuff to prevent leakage of fluid to the lungs
    • Young PJ, Ridley SA, Downward G. Evaluation of a new design of tracheal tube cuff to prevent leakage of fluid to the lungs. Br J Anaesth. 1998;80:796-799
    • (1998) Br J Anaesth , vol.80 , pp. 796-799
    • Young, P.J.1    Ridley, S.A.2    Downward, G.3
  • 6
    • 0035142470 scopus 로고    scopus 로고
    • Leakage of fluid around high-volume, lowpressure cuffs apparatus: A comparison of four tracheal tubes
    • Asai T, Shingu K. Leakage of fluid around high-volume, lowpressure cuffs apparatus: a comparison of four tracheal tubes. Anaesthesia. 2001;56:38-42.
    • (2001) Anaesthesia , vol.56 , pp. 38-42
    • Asai, T.1    Shingu, K.2
  • 7
    • 46149112982 scopus 로고    scopus 로고
    • A double-layer tracheal tube cuff designed to prevent leakage: A bench-top study
    • Zanella A, Cressoni M, Epp M, Stylianou M, Kolobow T. A double-layer tracheal tube cuff designed to prevent leakage: a bench-top study. Intensive Care Med. 2008;34:1145-1149
    • (2008) Intensive Care Med. , vol.34 , pp. 1145-1149
    • Zanella, A.1    Cressoni, M.2    Epp, M.3    Stylianou, M.4    Kolobow, T.5
  • 8
    • 0032746568 scopus 로고    scopus 로고
    • Improving the shape and compliance characteristics of a high-volume, low-pressure cuff improves tracheal seal
    • Young PJ, Blunt MC. Improving the shape and compliance characteristics of a high-volume, low-pressure cuff improves tracheal seal. Br J Anaesth. 1999;83:887-889
    • (1999) Br J Anaesth. , vol.83 , pp. 887-889
    • Young, P.J.1    Blunt, M.C.2
  • 9
    • 0032996739 scopus 로고    scopus 로고
    • Prevention of tracheal aspiration using the pressure-limited tracheal tube cuff
    • Young PJ, Basson C, Hamilton D, Ridley SA. Prevention of tracheal aspiration using the pressure-limited tracheal tube cuff. Anaesthesia. 1999;54:559-563
    • (1999) Anaesthesia , vol.54 , pp. 559-563
    • Young, P.J.1    Basson, C.2    Hamilton, D.3    Ridley, S.A.4
  • 10
    • 40949155070 scopus 로고    scopus 로고
    • Polyurethane cuffed endotracheal tubes to prevent early postoperative pneumonia after cardiac surgery: A pilot study
    • Poelaert J, Depuydt P, De Wolf A, Van de Velde S, Herck I, Blot S. Polyurethane cuffed endotracheal tubes to prevent early postoperative pneumonia after cardiac surgery: a pilot study. J Thorac Cardiovasc Surg. 2008;135:771-776
    • (2008) J Thorac Cardiovasc Surg. , vol.135 , pp. 771-776
    • Poelaert, J.1    Depuydt, P.2    De Wolf, A.3    Van De Velde, S.4    Herck, I.5    Blot, S.6
  • 11
    • 0034899552 scopus 로고    scopus 로고
    • Gel lubrication of the tracheal tube cuff reduces pulmonary aspiration
    • Blunt MC, Young PJ, Patil A, Haddock A. Gel lubrication of the tracheal tube cuff reduces pulmonary aspiration. Anesthesiology. 2001;95:377-381
    • (2001) Anesthesiology , vol.95 , pp. 377-381
    • Blunt, M.C.1    Young, P.J.2    Patil, A.3    Haddock, A.4
  • 12
    • 33644805641 scopus 로고    scopus 로고
    • The effect of gel lubrication on cuff leakage of double lumen tubes during thoracic surgery
    • Sanjay PS, Miller SA, Corry PR, Russell GN, Pennefather SH. The effect of gel lubrication on cuff leakage of double lumen tubes during thoracic surgery. Anaesthesia. 2006;61:133-137
    • (2006) Anaesthesia , vol.61 , pp. 133-137
    • Sanjay, P.S.1    Miller, S.A.2    Corry, P.R.3    Russell, G.N.4    Pennefather, S.H.5
  • 13
    • 38549158409 scopus 로고    scopus 로고
    • Effect of positive expiratory pressure and type of tracheal cuff on the incidence of aspiration in mechanically ventilated patients in an intensive care unit
    • Lucangelo U, Zin WA, Antonaglia V, Petrucci L, Viviani M, Buscema G, Borelli M, Berlot G. Effect of positive expiratory pressure and type of tracheal cuff on the incidence of aspiration in mechanically ventilated patients in an intensive care unit. Crit Care Med. 2008;36:409-413
    • (2008) Crit Care Med. , vol.36 , pp. 409-413
    • Lucangelo, U.1    Zin, W.A.2    Antonaglia, V.3    Petrucci, L.4    Viviani, M.5    Buscema, G.6    Borelli, M.7    Berlot, G.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.