-
1
-
-
0027999435
-
Biomechanical analysis of cervical stabilization systems: An assessment of transpedicular screw fixation in the cervical spine
-
7855677 10.1097/00007632-199411001-00007 1:STN:280:DyaK2M7lvV2mug%3D%3D
-
Kotani Y, Cunningham BW, Abumi K, McAfee PC (1994) Biomechanical analysis of cervical stabilization systems: an assessment of transpedicular screw fixation in the cervical spine. Spine 19(22):2529-2539
-
(1994)
Spine
, vol.19
, Issue.22
, pp. 2529-2539
-
-
Kotani, Y.1
Cunningham, B.W.2
Abumi, K.3
McAfee, P.C.4
-
2
-
-
0031010622
-
Cervical pedicle screws versus lateral mass screws: Anatomic feasibility and biomechanical comparison
-
9152447 10.1097/00007632-199705010-00009 1:STN:280:DyaK2s3ps12kug%3D%3D
-
Jones EL, Heller JG, Silcox DH, Hutton WC (1997) Cervical pedicle screws versus lateral mass screws: anatomic feasibility and biomechanical comparison. Spine 22(9):977-982
-
(1997)
Spine
, vol.22
, Issue.9
, pp. 977-982
-
-
Jones, E.L.1
Heller, J.G.2
Silcox, D.H.3
Hutton, W.C.4
-
3
-
-
0028012268
-
Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: Description of the techniques and preliminary report
-
8186585 10.1097/00002517-199407010-00003 1:STN:280:DyaK2c3ktlWlsQ%3D%3D
-
Abumi K, Itoh H, Taneichi H, Kaneda K (1994) Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report. J Spinal Disord 7(1):19-28
-
(1994)
J Spinal Disord
, vol.7
, Issue.1
, pp. 19-28
-
-
Abumi, K.1
Itoh, H.2
Taneichi, H.3
Kaneda, K.4
-
4
-
-
84857910220
-
Reconstruction of the subaxial cervical spine using pedicle screw instrumentation
-
22020588 10.1097/BRS.0b013e318239cf1f
-
Abumi K, Ito M, Sudo H (2012) Reconstruction of the subaxial cervical spine using pedicle screw instrumentation. Spine 37(5):E349-E356
-
(2012)
Spine
, vol.37
, Issue.5
-
-
Abumi, K.1
Ito, M.2
Sudo, H.3
-
5
-
-
75049086017
-
Subaxial cervical pedicle screw insertion with newly defined entry point and trajectory: Accuracy evaluation in cadavers
-
19916031 10.1007/s00586-009-1213-4
-
Zheng X, Chaudhari R, Wu C, Mehbod AA, Transfeldt EE (2010) Subaxial cervical pedicle screw insertion with newly defined entry point and trajectory: accuracy evaluation in cadavers. Eur Spine J 19(1):105-112
-
(2010)
Eur Spine J
, vol.19
, Issue.1
, pp. 105-112
-
-
Zheng, X.1
Chaudhari, R.2
Wu, C.3
Mehbod, A.A.4
Transfeldt, E.E.5
-
6
-
-
33644658640
-
Complications of transpedicular screw fixation in the cervical spine
-
15912352 10.1007/s00586-004-0861-7 1:STN:280:DC%2BD287ivV2ktA%3D%3D
-
Kast E, Morh K, Richter HP, Börm W (2006) Complications of transpedicular screw fixation in the cervical spine. Eur Spine J 15(3):327-334
-
(2006)
Eur Spine J
, vol.15
, Issue.3
, pp. 327-334
-
-
Kast, E.1
Morh, K.2
Richter, H.P.3
Börm, W.4
-
7
-
-
84861304427
-
Accuracy of pedicle screw placement- a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation
-
21901328 10.1007/s00586-011-2011-3
-
Gelalis ID, Paschos NK, Pakos EE, Politis AN, Arnaoutoglou CM, Karageorgos AC, Ploumis A, Xenakis TA (2012) Accuracy of pedicle screw placement- a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation. Eur Spine J 21(2):247-255
-
(2012)
Eur Spine J
, vol.21
, Issue.2
, pp. 247-255
-
-
Gelalis, I.D.1
Paschos, N.K.2
Pakos, E.E.3
Politis, A.N.4
Arnaoutoglou, C.M.5
Karageorgos, A.C.6
Ploumis, A.7
Xenakis, T.A.8
-
8
-
-
78149332417
-
Clinical accuracy of three-dimensional fluoroscopy-based computer-assisted cervical pedicle screw placement: A retrospective comparative study of conventional versus computer-assisted cervical pedicle screw placement
-
21039152 10.3171/2010.5.SPINE09993
-
Ishikawa Y, Kanemura T, Yoshida G, Ito Z, Muramoto A, Ohno S (2010) Clinical accuracy of three-dimensional fluoroscopy-based computer-assisted cervical pedicle screw placement: a retrospective comparative study of conventional versus computer-assisted cervical pedicle screw placement. J Neurosurg Spine 13(5):606-611
-
(2010)
J Neurosurg Spine
, vol.13
, Issue.5
, pp. 606-611
-
-
Ishikawa, Y.1
Kanemura, T.2
Yoshida, G.3
Ito, Z.4
Muramoto, A.5
Ohno, S.6
-
9
-
-
70349659518
-
Clinical accuracy of cervical pedicle screw insertion using lateral fluoroscopy: A radiographic analysis of the learning curve
-
19653013 10.1007/s00586-009-1109-3
-
Yoshimoto H, Sato S, Hyakumachi T, Yanagibashi Y, Kanno T, Masuda T (2009) Clinical accuracy of cervical pedicle screw insertion using lateral fluoroscopy: a radiographic analysis of the learning curve. Eur Spine J 18(9):1326-1334
-
(2009)
Eur Spine J
, vol.18
, Issue.9
, pp. 1326-1334
-
-
Yoshimoto, H.1
Sato, S.2
Hyakumachi, T.3
Yanagibashi, Y.4
Kanno, T.5
Masuda, T.6
-
10
-
-
84870385824
-
Cervical pedicle screw placement using the "key slot technique". the feasibility and learning curve
-
(Epub Ahead of Print)
-
Lee SH, Kim KT, Abumi K, Suk KS, Lee JH, Park KJ (2012) Cervical pedicle screw placement using the Key slot technique.The feasibility and learning curve. J Spinal Disord Tech (Epub Ahead of Print)
-
(2012)
J Spinal Disord Tech
-
-
Lee, S.H.1
Kim, K.T.2
Abumi, K.3
Suk, K.S.4
Lee, J.H.5
Park, K.J.6
-
11
-
-
0035890086
-
Accuracy of cervical pedicle screw placement using the funnel technique
-
11707710 10.1097/00007632-200111150-00012 1:STN:280: DC%2BD3MnotFahtA%3D%3D
-
Karaikovic EE, Yingsakmongkol W, Gaines RW Jr (2001) Accuracy of cervical pedicle screw placement using the funnel technique. Spine 26(22):2456-2462
-
(2001)
Spine
, vol.26
, Issue.22
, pp. 2456-2462
-
-
Karaikovic, E.E.1
Yingsakmongkol, W.2
Gaines, Jr.R.W.3
-
12
-
-
84880143535
-
Transpedicular screw fixation for the lower cervical spine: Anatomical measurement
-
(CHN)
-
Jingmign Xie, Zhang Yangjie Lu, Ning Liu Zhongliang, Yingsong Wang, Ying Zhang (2006) Transpedicular screw fixation for the lower cervical spine: anatomical measurement. J Spinal Surg 4(6):354-358 (CHN)
-
(2006)
J Spinal Surg
, vol.4
, Issue.6
, pp. 354-358
-
-
Jingmign, X.1
Zhang Yangjie, L.2
Ning, L.Z.3
Yingsong, W.4
Ying, Z.5
-
13
-
-
45449116497
-
CT evaluation of cervical pedicle in a Chinese population for surgical application of transpedicular screw placement
-
10.1007/s00276-008-0339-0 1:CAS:528:DC%2BD1MXhs12qt7c%3D
-
Zhu RF, Yang HL, Hu XY, He XS, Tang TS, Chen L, Li XG (2008) CT evaluation of cervical pedicle in a Chinese population for surgical application of transpedicular screw placement. Surg Radiol Anat 30(5):389-396
-
(2008)
Surg Radiol Anat
, vol.30
, Issue.5
, pp. 389-396
-
-
Zhu, R.F.1
Yang, H.L.2
Hu, X.Y.3
He, X.S.4
Tang, T.S.5
Chen, L.6
Li, X.G.7
-
14
-
-
77954246251
-
The vertebral artery and the cervical pedicle: Morphometric analysis of a critical neighborhood
-
20594018 10.3171/2010.3.SPINE09231
-
Tomasino A, Parikh K, Koller H, Zink W, Tsiouris J, Steinberger J, Hartl R (2010) The vertebral artery and the cervical pedicle: morphometric analysis of a critical neighborhood. J Neurosurg Spine 13(1):52-60
-
(2010)
J Neurosurg Spine
, vol.13
, Issue.1
, pp. 52-60
-
-
Tomasino, A.1
Parikh, K.2
Koller, H.3
Zink, W.4
Tsiouris, J.5
Steinberger, J.6
Hartl, R.7
-
15
-
-
0036266815
-
Normal variation of vertebral artery on CT angiography and its implications for diagnosis of acquired pathology
-
12016382 10.1097/00004728-200205000-00027
-
Sanelli PC, Tong S, Gonzalez G, Eskey CJ (2002) Normal variation of vertebral artery on CT angiography and its implications for diagnosis of acquired pathology. J Comput Assist Tomogr 26(3):462-470
-
(2002)
J Comput Assist Tomogr
, vol.26
, Issue.3
, pp. 462-470
-
-
Sanelli, P.C.1
Tong, S.2
Gonzalez, G.3
Eskey, C.J.4
-
16
-
-
0033797290
-
Surgical anatomy of the cervical pedicles: Landmarks for posterior cervical pedicle entrance localization
-
10710153 10.1097/00002517-200002000-00013 1:STN:280: DC%2BD3c7ntlertQ%3D%3D
-
Karaikovic EE, Kunakornsawat S, Daubs MD, Madsen TW, Gaines RW Jr (2000) Surgical anatomy of the cervical pedicles: landmarks for posterior cervical pedicle entrance localization. J Spinal Disord 13(1):63-72
-
(2000)
J Spinal Disord
, vol.13
, Issue.1
, pp. 63-72
-
-
Karaikovic, E.E.1
Kunakornsawat, S.2
Daubs, M.D.3
Madsen, T.W.4
Gaines, Jr.R.W.5
-
17
-
-
0034655412
-
Complications of pedicle screw fixation in reconstructive surgery of the cervical spine
-
10767809 10.1097/00007632-200004150-00011 1:STN:280: DC%2BD3c3jt1Sgtw%3D%3D
-
Abumi K, Shono Y, Ito M, Taneichi H, Kotani Y, Kaneda K (2000) Complications of pedicle screw fixation in reconstructive surgery of the cervical spine. Spine 25(8):962-969
-
(2000)
Spine
, vol.25
, Issue.8
, pp. 962-969
-
-
Abumi, K.1
Shono, Y.2
Ito, M.3
Taneichi, H.4
Kotani, Y.5
Kaneda, K.6
-
18
-
-
0033771307
-
Biomechanical evaluation of a new modular rod-screw implant system for posterior instrumentation of the occipito-cervical spine: In vitro comparison with two established implant systems
-
11057536 10.1007/s005860000173 1:STN:280:DC%2BD3crgsFyksQ%3D%3D
-
Richter M, Wilke HJ, Kluger P, Neller S, Claes L, Puhl W (2000) Biomechanical evaluation of a new modular rod-screw implant system for posterior instrumentation of the occipito-cervical spine: in vitro comparison with two established implant systems. Eur Spine J 9(5):417-425
-
(2000)
Eur Spine J
, vol.9
, Issue.5
, pp. 417-425
-
-
Richter, M.1
Wilke, H.J.2
Kluger, P.3
Neller, S.4
Claes, L.5
Puhl, W.6
|