메뉴 건너뛰기




Volumn 186, Issue , 2013, Pages 486-494

Functionalized carbon nanotubes - With silver nanoparticles to fabricate a sensor for the determination of zolmitriptan in its dosage forms and biological samples

Author keywords

Determination; Human urine samples; Multi walled carbon nanotubes; Silver nanoparticles; Voltammetry; Zolmitriptan

Indexed keywords

DETERMINATION; FUNCTIONALIZED CARBON NANOTUBES; FUNCTIONALIZED MULTI-WALLED CARBON NANOTUBES; HUMAN URINE SAMPLES; MODIFIED GLASSY CARBON ELECTRODE; SILVER NANOPARTICLES; VOLTAMMETRIC DETERMINATION; ZOLMITRIPTAN;

EID: 84880072364     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2013.06.055     Document Type: Article
Times cited : (34)

References (62)
  • 3
    • 84868699926 scopus 로고    scopus 로고
    • Development and validation of liquid chromatographic method for the determination of zolmitriptan in pharmaceutical formulations
    • T. Srinivasu, M. Mathrusri Annapurna, and T.G. Chandrasekhar Development and validation of liquid chromatographic method for the determination of zolmitriptan in pharmaceutical formulations Drug Invent. Today 4 2012 450 454
    • (2012) Drug Invent. Today , vol.4 , pp. 450-454
    • Srinivasu, T.1    Mathrusri Annapurna, M.2    Chandrasekhar, T.G.3
  • 7
    • 17244364318 scopus 로고    scopus 로고
    • Determination of zolmitriptan enantiomers in rat liver microsomes by chiral high performance liquid chromatography with fluorescence detection
    • DOI 10.1002/bmc.433
    • L. Yu, T. Yao, S. Ni, and S. Zeng Determination of zolmitriptan enentiomers in rat liver microsomes by chiral high performance liquid chromatography with florescence detection Biomed. Chromatogr. 19 2005 191 195 (Pubitemid 40528584)
    • (2005) Biomedical Chromatography , vol.19 , Issue.3 , pp. 191-195
    • Yu, L.1    Yao, T.2    Ni, S.3    Zeng, S.4
  • 8
    • 2342614752 scopus 로고    scopus 로고
    • High-performance liquid chromatographic analysis of zolmitriptan in human plasma using fluorescence detection
    • DOI 10.1016/j.jpba.2004.01.019, PII S073170850400041X
    • J. Chen, X.G. Jiang, W.M. Jiang, N. Mei, X.L. Gao, and Q.Z. Zhang High performance liquid chromatographic analysis of zolmitriptan in human plasma using florescence detection J. Pharm. Biomed. 35 2004 639 645 (Pubitemid 38609386)
    • (2004) Journal of Pharmaceutical and Biomedical Analysis , vol.35 , Issue.3 , pp. 639-645
    • Chen, J.1    Jiang, X.-G.2    Jiang, W.-M.3    Mei, N.4    Gao, X.-L.5    Zhang, Q.-Z.6
  • 10
    • 33750915825 scopus 로고    scopus 로고
    • Determination of zolmitriptan in human plasma by HPLC-MS and study on bioequivalence of domestic and import zolmitriptan tablets
    • J.S. Ding, R.H. Zhu, Y.G. Zhu, and H.D. Li Determination of zolmitriptan in human plasma by HPLC-MS and study on bioequivalence of domestic and import zolmitriptan tablets Chin. Pharm. J. 41 2006 1488 1490
    • (2006) Chin. Pharm. J. , vol.41 , pp. 1488-1490
    • Ding, J.S.1    Zhu, R.H.2    Zhu, Y.G.3    Li, H.D.4
  • 12
    • 84863782325 scopus 로고    scopus 로고
    • Quantitative determination of zolmitriptan in rat blood and cerebrospinal fluid by reversed phase HPLC-ESI-MS/MS analysis: Application to in vivo preclinical pharmacokinetic study
    • A. Dalpiaz, N. Marchetti, A. Cavazzini, L. Pasti, S. Velaga, E. Gavini, S. Beggiato, and L. Ferraro Quantitative determination of zolmitriptan in rat blood and cerebrospinal fluid by reversed phase HPLC-ESI-MS/MS analysis: application to in vivo preclinical pharmacokinetic study J. Chromatogr. B 901 2012 72 78
    • (2012) J. Chromatogr. B , vol.901 , pp. 72-78
    • Dalpiaz, A.1    Marchetti, N.2    Cavazzini, A.3    Pasti, L.4    Velaga, S.5    Gavini, E.6    Beggiato, S.7    Ferraro, L.8
  • 13
    • 33646159045 scopus 로고    scopus 로고
    • Enantiometric separation of zolmitriptan by CE with a sulfated β-cyclodextrin chiral selector
    • C.Y. Wu, B. Di, X.M. Yao, J. Yang, and W.Y. Liu Enantiometric separation of zolmitriptan by CE with a sulfated β-cyclodextrin chiral selector J. China Pharm. Univ. 37 2006 137 141
    • (2006) J. China Pharm. Univ. , vol.37 , pp. 137-141
    • Wu, C.Y.1    Di, B.2    Yao, X.M.3    Yang, J.4    Liu, W.Y.5
  • 15
    • 38349025898 scopus 로고    scopus 로고
    • A novel spectrophotometric method for the determination of zolmitriptan in pharmaceutical formulations
    • A. Raza, T.M. Ansari, and S.B. Niazi A novel spectrophotometric method for the determination of zolmitriptan in pharmaceutical formulations J. Chin. Chem. Soc. 54 2007 1413 1417
    • (2007) J. Chin. Chem. Soc. , vol.54 , pp. 1413-1417
    • Raza, A.1    Ansari, T.M.2    Niazi, S.B.3
  • 16
    • 35348880264 scopus 로고    scopus 로고
    • Extractive spectrophotometric methods for determination of zolmitriptan in tablets
    • Z. Aydogmus, and I. Inanli Extractive spectrophotometric methods for determination of zolmitriptan in tablets J. AOAC Int. 90 2007 1237 1241 (Pubitemid 47583181)
    • (2007) Journal of AOAC International , vol.90 , Issue.5 , pp. 1237-1241
    • Aydogmus, Z.1    Inanli, I.2
  • 17
    • 77950610747 scopus 로고    scopus 로고
    • Anodic voltammetry of zolmitriptan at boron-doped diamond electrode and its analytical applications
    • B. Uslu, and D. Canbaz Anodic voltammetry of zolmitriptan at boron-doped diamond electrode and its analytical applications Pharmazie 65 2010 245 250
    • (2010) Pharmazie , vol.65 , pp. 245-250
    • Uslu, B.1    Canbaz, D.2
  • 18
    • 32644431876 scopus 로고    scopus 로고
    • The use of nanoparticles in electroanalysis: A review
    • DOI 10.1007/s00216-005-0230-3
    • C.M. Welch, and R.G. Compton The use of nanoparticles in electroanalysis: a review Anal. Bioanal. Chem. 384 2006 601 619 (Pubitemid 43239593)
    • (2006) Analytical and Bioanalytical Chemistry , vol.384 , Issue.3 , pp. 601-619
    • Welch, C.M.1    Compton, R.G.2
  • 19
    • 80051614031 scopus 로고    scopus 로고
    • A review on glucose and hydrogen peroxide biosensor based on modified electrode included silver nanoparticles
    • A.S. Rad, A. Mirabi, E. Binaian, and H. Tayebi A review on glucose and hydrogen peroxide biosensor based on modified electrode included silver nanoparticles Int. J. Electrochem. Sci. 6 2011 3671 3683
    • (2011) Int. J. Electrochem. Sci. , vol.6 , pp. 3671-3683
    • Rad, A.S.1    Mirabi, A.2    Binaian, E.3    Tayebi, H.4
  • 20
    • 84871867070 scopus 로고    scopus 로고
    • Multi-walled carbon nanotube modified glassy carbon electrode as a voltammetric nanosensor for the sensitive determination of anti-viral drug valganciclovir in pharmaceuticals
    • B. Dogan-Topal, B. Bozal-PalabIyIk, B. Uslu, and S.A. Ozkan Multi-walled carbon nanotube modified glassy carbon electrode as a voltammetric nanosensor for the sensitive determination of anti-viral drug valganciclovir in pharmaceuticals Sens. Actuator B 177 2013 841 847
    • (2013) Sens. Actuator B , vol.177 , pp. 841-847
    • Dogan-Topal, B.1    Bozal-Palabiyik, B.2    Uslu, B.3    Ozkan, S.A.4
  • 21
    • 34447558481 scopus 로고    scopus 로고
    • 60-modified electrode as a sensitive voltammetric sensor for detection of nandrolone-An anabolic steroid used in doping
    • DOI 10.1016/j.aca.2007.06.017, PII S000326700701046X
    • 60-modified electrode as a sensitive voltammetric sensor for detection of nandrolone - an anabolic steroid used in doping Anal. Chim. Acta 597 2007 82 89 (Pubitemid 47068384)
    • (2007) Analytica Chimica Acta , vol.597 , Issue.1 , pp. 82-89
    • Goyal, R.N.1    Gupta, V.K.2    Bachheti, N.3
  • 23
    • 65549152984 scopus 로고    scopus 로고
    • 60-modified edge plane pyrolytic graphite electrode for the determination of dexamethasone in pharmaceutical formulations and human biological fluids
    • 60- modified edge plane pyrolytic graphite electrode for the determination of dexamethasone in pharmaceutical formulations and human biological fluids Biosens. Bioelectron. 24 2009 1649 1654
    • (2009) Biosens. Bioelectron. , vol.24 , pp. 1649-1654
    • Goyal, R.N.1    Gupta, V.K.2    Chatterjee, S.3
  • 24
    • 33846178200 scopus 로고    scopus 로고
    • Schiff bases as cadmium(II) selective ionophores in polymeric membrane electrodes
    • DOI 10.1016/j.aca.2006.10.039, PII S0003267006021167
    • V.K. Gupta, A.K. Singh, and B. Gupta Schiff bases as cadmium(II) selective ionophores in polymeric membrane electrodes Anal. Chim. Acta 583 2007 340 348 (Pubitemid 46080373)
    • (2007) Analytica Chimica Acta , vol.583 , Issue.2 , pp. 340-348
    • Gupta, V.K.1    Singh, A.K.2    Gupta, B.3
  • 25
    • 78149465859 scopus 로고    scopus 로고
    • Voltammetric techniques for the assay of pharmaceuticals - A review
    • V.K. Gupta, R. Jain, K. Radhapyari, N. Jadon, and S. Agarwal Voltammetric techniques for the assay of pharmaceuticals - a review Anal. Biochem. 408 2011 179 196
    • (2011) Anal. Biochem. , vol.408 , pp. 179-196
    • Gupta, V.K.1    Jain, R.2    Radhapyari, K.3    Jadon, N.4    Agarwal, S.5
  • 26
    • 0001101267 scopus 로고    scopus 로고
    • A PVC-Based Pentathia-15-Crown-5 Membrane Potentiometric Sensor for Mercury(II)
    • V.K. Gupta, S. Jain, and U. Khurana A PVC-based pentathia-15-crown4 membrane potentiometric sensor for mercury(II) Electroanalysis 9 1997 478 480 (Pubitemid 127444109)
    • (1997) Electroanalysis , vol.9 , Issue.6 , pp. 478-480
    • Gupta, V.K.1    Jain, S.2    Khurana, U.3
  • 27
    • 0000000504 scopus 로고    scopus 로고
    • Determination of uranyl ions using poly(vinyl chloride) based 4-tert-butylcalix[6]arene membrane sensor
    • V.K. Gupta, R. Mangla, U. Khurana, and P. Kumar Determination of uranyl ions using poly(vinyl chloride) based 4-tert-butylcalix[6]arene membrane sensor Electroanalysis 11 1999 573 576
    • (1999) Electroanalysis , vol.11 , pp. 573-576
    • Gupta, V.K.1    Mangla, R.2    Khurana, U.3    Kumar, P.4
  • 28
    • 0036499849 scopus 로고    scopus 로고
    • Dicyclohexano-18-crown-6 as active material in PVC matrix membrane for the fabrication of cadmium selective potentiometric sensor
    • DOI 10.1016/S0013-4686(01)00895-7, PII S0013468601008957
    • V.K. Gupta, S. Chandra, and R. Mangla Dicyclohexano-18-crown-6 as active material in PVC matrix membrane for the fabrication of cadmium selective potentiometric sensor Electrochim. Acta 47 2002 1579 1586 (Pubitemid 34182451)
    • (2002) Electrochimica Acta , vol.47 , Issue.10 , pp. 1579-1586
    • Gupta, V.K.1    Chandra, S.2    Mangla, R.3
  • 29
    • 0037569436 scopus 로고    scopus 로고
    • Preparation of ethambutol-copper(II) complex and fabrication of PVC based membrane potentiometric sensor for copper
    • V.K. Gupta, R. Prasad, and A. Kumar Preparation of ethambutol-copper(II) complex and fabrication of PVC based membrane potentiometric sensor for copper Talanta 60 2003 149 160
    • (2003) Talanta , vol.60 , pp. 149-160
    • Gupta, V.K.1    Prasad, R.2    Kumar, A.3
  • 30
    • 18844399095 scopus 로고    scopus 로고
    • A highly selective mercury electrode based on a diamine donor ligand
    • DOI 10.1016/j.talanta.2004.11.028, PII S0039914004006885
    • V.K. Gupta, S. Chandrab, and H. Lang A highly selective mercury electrode based on a diamine donor ligand Talanta 66 2005 575 580 (Pubitemid 40683817)
    • (2005) Talanta , vol.66 , Issue.3 , pp. 575-580
    • Gupta, V.K.1    Chandra, S.2    Lang, H.3
  • 31
    • 34047129318 scopus 로고    scopus 로고
    • Neutral carriers based polymeric membrane electrodes for selective determination of mercury (II)
    • DOI 10.1016/j.aca.2007.03.014, PII S0003267007004965
    • V.K. Gupta, A.K. Singh, M. Al Khayat, and B. Gupta Neutral carriers based polymeric membrane electrodes for selective determination of mercury (II) Anal. Chim. Acta 590 2007 81 90 (Pubitemid 46528388)
    • (2007) Analytica Chimica Acta , vol.590 , Issue.1 , pp. 81-90
    • Gupta, V.K.1    Singh, A.K.2    Al Khayat, M.3    Gupta, B.4
  • 32
    • 67649378642 scopus 로고    scopus 로고
    • Comparative studies of neodymium (III)-selective PVC membrane sensors
    • V.K. Gupta, R.N. Goyal, and R.A. Sharma Comparative studies of neodymium (III)-selective PVC membrane sensors Anal. Chim. Acta 647 2009 66 71
    • (2009) Anal. Chim. Acta , vol.647 , pp. 66-71
    • Gupta, V.K.1    Goyal, R.N.2    Sharma, R.A.3
  • 33
    • 33646041279 scopus 로고    scopus 로고
    • A cobalt(II)-selective PVC membrane based on a Schiff base complex of N,N-bis(salicylidene)-3,4-diaminotoluene
    • V.K. Gupta, A.K. Singh, S. Mehtab, and B. Gupta A cobalt(II)-selective PVC membrane based on a Schiff base complex of N,N-bis(salicylidene)-3,4- diaminotoluene Anal. Chim. Acta 566 2006 5 10
    • (2006) Anal. Chim. Acta , vol.566 , pp. 5-10
    • Gupta, V.K.1    Singh, A.K.2    Mehtab, S.3    Gupta, B.4
  • 34
    • 33745727650 scopus 로고    scopus 로고
    • Copper(II)-selective potentiometric sensors based on porphyrins in PVC matrix
    • V.K. Gupta, A.K. Jain, G. Maheshwari, H. Lang, and Z. Ishtaiwi Copper(II)-selective potentiometric sensors based on porphyrins in PVC matrix Sens. Actuator B 117 2006 99 106
    • (2006) Sens. Actuator B , vol.117 , pp. 99-106
    • Gupta, V.K.1    Jain, A.K.2    Maheshwari, G.3    Lang, H.4    Ishtaiwi, Z.5
  • 35
    • 33749254455 scopus 로고    scopus 로고
    • PVC-based membranes of N,N′-dibenzyl-1,4,10,13-tetraoxa-7,16- diazacyclooctadecane as Pb(II)-selective sensor
    • DOI 10.1016/j.snb.2006.02.019, PII S0925400506000980
    • V.K. Gupta, A.K. Jain, and P. Kumar PVC-based membranes of N,N′-dibenzyl-1,4,10,13-tetraoxa-7,16-diazacyclooctadecane as Pb(II)-selective sensor Sens. Actuator B 120 2006 259 265 (Pubitemid 44486698)
    • (2006) Sensors and Actuators, B: Chemical , vol.120 , Issue.1 , pp. 259-265
    • Gupta, V.K.1    Jain, A.K.2    Kumar, P.3
  • 36
    • 29244459114 scopus 로고    scopus 로고
    • Chromium(III)-selective sensor based on tri-o-thymotide in PVC matrix
    • DOI 10.1016/j.snb.2005.02.046, PII S0925400505002297
    • V.K. Gupta, A.K. Jain, P. Kumar, S. Agarwal, and G. Maheshwari Chromium(III)-selective sensor based on tri-o-thymotide in PVC matrix Sens. Actuator B 113 2006 182 186 (Pubitemid 41831285)
    • (2006) Sensors and Actuators, B: Chemical , vol.113 , Issue.1 , pp. 182-186
    • Gupta, V.K.1    Jain, A.K.2    Kumar, P.3    Agarwal, S.4    Maheshwari, G.5
  • 37
    • 51649100721 scopus 로고    scopus 로고
    • Sensors for 5-hydroxytryptamine and 5-hydroxyindole acetic acid based on nanomaterial modified electrodes
    • R.N. Goyal, M. Oyama, V.K. Gupta, S.P. Singh, and R.A. Sharma Sensors for 5-hydroxytryptamine and 5-hydroxyindole acetic acid based on nanomaterial modified electrodes Sens. Actuator B 134 2008 816 821
    • (2008) Sens. Actuator B , vol.134 , pp. 816-821
    • Goyal, R.N.1    Oyama, M.2    Gupta, V.K.3    Singh, S.P.4    Sharma, R.A.5
  • 41
    • 67650045961 scopus 로고    scopus 로고
    • A sensitive voltammetric sensor for determination of synthetic corticosteroid triamcinolone, abused for doping
    • R.N. Goyal, V.K. Gupta, and S. Chatterjee A sensitive voltammetric sensor for determination of synthetic corticosteroid triamcinolone, abused for doping Biosens. Bioelectron. 24 2009 3562 3568
    • (2009) Biosens. Bioelectron. , vol.24 , pp. 3562-3568
    • Goyal, R.N.1    Gupta, V.K.2    Chatterjee, S.3
  • 42
    • 67949124550 scopus 로고    scopus 로고
    • Preparation of nano-copper oxide modified glassy carbon electrode by a novel film plating/potential cycling method and its characterization
    • W.Z. Le, and Y.Q. Liu Preparation of nano-copper oxide modified glassy carbon electrode by a novel film plating/potential cycling method and its characterization Sens. Actuator B 141 2009 147 153
    • (2009) Sens. Actuator B , vol.141 , pp. 147-153
    • Le, W.Z.1    Liu, Y.Q.2
  • 43
    • 84868578769 scopus 로고    scopus 로고
    • Monodispersed gold nanoparticles decorated carbon nanotubes as an enhanced sensing platform for nanomolar detection of tramadol
    • N.F. Atta, R.A. Ahmed, H.M.A. Amin, and A. Galal Monodispersed gold nanoparticles decorated carbon nanotubes as an enhanced sensing platform for nanomolar detection of tramadol Electroanalysis 24 2012 2135 2146
    • (2012) Electroanalysis , vol.24 , pp. 2135-2146
    • Atta, N.F.1    Ahmed, R.A.2    Amin, H.M.A.3    Galal, A.4
  • 44
    • 62949196986 scopus 로고    scopus 로고
    • Poly (brilliant cresyl blue) modified glassy carbon electrodes: Electrosynthesis, characterisation and application in biosensors
    • M.E. Ghica, and C.M.A. Brett Poly (brilliant cresyl blue) modified glassy carbon electrodes: electrosynthesis, characterisation and application in biosensors J. Electroanal. Chem. 629 2009 35 42
    • (2009) J. Electroanal. Chem. , vol.629 , pp. 35-42
    • Ghica, M.E.1    Brett, C.M.A.2
  • 45
    • 33645783152 scopus 로고    scopus 로고
    • Voltammetric studies and determination of levodopa and carbidopa in pharmaceutical products
    • M.S. Maio Quintino, M. Yamashita, and L. Angnes Voltammetric studies and determination of levodopa and carbidopa in pharmaceutical products Electroanalysis 18 2006 655 661
    • (2006) Electroanalysis , vol.18 , pp. 655-661
    • Maio Quintino, M.S.1    Yamashita, M.2    Angnes, L.3
  • 48
    • 0344464870 scopus 로고    scopus 로고
    • Development of an amperometric indole-3-acetic acid sensor based on carbon nanotubes film coated glassy carbon electrode
    • K. Wu, Y. Sun, and S. Hu Development of an amperometric indole-3-acetic acid sensor based on carbon nanotubes film coated glassy carbon electrode Sens. Actuator B-Chem. 96 2003 658 662
    • (2003) Sens. Actuator B-Chem. , vol.96 , pp. 658-662
    • Wu, K.1    Sun, Y.2    Hu, S.3
  • 51
    • 84861222691 scopus 로고    scopus 로고
    • Voltammetric and RP-LC assay for determination of benidipine HCl
    • N. Karadas, S. Sanli, M. Gumustas, and S.A. Ozkan Voltammetric and RP-LC assay for determination of benidipine HCl J. Pharm. Biomed. 66 2012 116 125
    • (2012) J. Pharm. Biomed. , vol.66 , pp. 116-125
    • Karadas, N.1    Sanli, S.2    Gumustas, M.3    Ozkan, S.A.4
  • 55
    • 0142197899 scopus 로고    scopus 로고
    • Analysis of pharmaceuticals and biological fluids using modern electroanalytical techniques
    • S.A. Ozkan, B. Uslu, and H.Y. Aboul-Enein Analysis of pharmaceuticals and biological fluids using modern electroanalytical techniques Crit. Rev. Anal. Chem. 33 2003 155 181 (Pubitemid 37317186)
    • (2003) Critical Reviews in Analytical Chemistry , vol.33 , Issue.3 , pp. 155-181
    • Ozkan, S.A.1    Uslu, B.2    Aboul-Enein, H.Y.3
  • 58
    • 0032029299 scopus 로고    scopus 로고
    • Oxidation chemistry and biochemistry of indole and effect of its oxidation product in albino mice
    • DOI 10.1016/S0302-4598(98)00066-X, PII S030245989800066X
    • R.N. Goyal, N. Kumar, and N.K. Singhal Oxidation chemistry and biochemistry of indole and effect of its oxidation product in albino mice Bioelectrochem. Bioenerg. 45 1998 47 53 (Pubitemid 28264405)
    • (1998) Bioelectrochemistry and Bioenergetics , vol.45 , Issue.1 , pp. 47-53
    • Goyal, R.N.1    Kumar, N.2    Singhal, N.K.3
  • 60
    • 0037758014 scopus 로고    scopus 로고
    • Electroanalytical evaluation and determination of 5-(3′-indolyl)-2- thiohydantoin derivatives by voltammetric studies: Possible relevance to in vitro metabolism
    • DOI 10.1039/b300160c
    • S. Suzen, B.T. Demircigil, E. Buyukbingol, and S.A. Ozkan Electroanalytical evaluation and determination of 5-(3′-indolyl)-2- thiohydantoin derivatives by voltammetric studies: possible relevance to in vitro metabolism New J. Chem. 27 2003 1007 1011 (Pubitemid 36774099)
    • (2003) New Journal of Chemistry , vol.27 , Issue.6 , pp. 1007-1011
    • Suzen, S.1    Demircigil, B.T.2    Buyukbingol, E.3    Ozkan, S.A.4
  • 61
    • 77955430276 scopus 로고    scopus 로고
    • Electroanalytical characteristics of antipsychotic drug ziprasidone and its determination in pharmaceuticals and serum samples on solid electrodes
    • D. Kul, M. Gumustas, B. Uslu, and S.A. Ozkan Electroanalytical characteristics of antipsychotic drug ziprasidone and its determination in pharmaceuticals and serum samples on solid electrodes Talanta 82 2010 286 295
    • (2010) Talanta , vol.82 , pp. 286-295
    • Kul, D.1    Gumustas, M.2    Uslu, B.3    Ozkan, S.A.4
  • 62
    • 79957863668 scopus 로고    scopus 로고
    • Pathways of electrochemical oxidation of indolic compounds
    • T.A. Enache, and A.M. Olivera-Brett Pathways of electrochemical oxidation of indolic compounds Electroanalysis 23 2011 1337 1344
    • (2011) Electroanalysis , vol.23 , pp. 1337-1344
    • Enache, T.A.1    Olivera-Brett, A.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.