1
-
-
63449101277
-
Comparison between hot-gas bypass defrosting and reverse-cycle defrosting methods on an air-to-water heat pump
-
D. Huang, Q.X. Li, and X.L. Yuan Comparison between hot-gas bypass defrosting and reverse-cycle defrosting methods on an air-to-water heat pump Appl. Energy 86 2009 1697 1703
-
(2009)
Appl. Energy
, vol.86
, pp. 1697-1703
-
-
Huang, D.1
Li, Q.X.2
Yuan, X.L.3
-
2
-
-
84856382592
-
An experimental study on defrosting heat supplies and energy consumptions during a reverse cycle defrost operation for an air source heat pump
-
J.K. Dong, S.M. Deng, and Y.Q. Jiang An experimental study on defrosting heat supplies and energy consumptions during a reverse cycle defrost operation for an air source heat pump Appl. Therm. Eng. 37 2012 380 387
-
(2012)
Appl. Therm. Eng.
, vol.37
, pp. 380-387
-
-
Dong, J.K.1
Deng, S.M.2
Jiang, Y.Q.3
-
3
-
-
0000722159
-
Heat pump performance under frosting conditions: Part II - Simulation of heat pump cycle characteristics under frosting conditions
-
Y. Yasuda, T. Senshu, S. Kuroda, T. Atsumi, and K. Oguni Heat pump performance under frosting conditions: part II - simulation of heat pump cycle characteristics under frosting conditions ASHRAE Trans. 96 1990 330 336
-
(1990)
ASHRAE Trans.
, vol.96
, pp. 330-336
-
-
Yasuda, Y.1
Senshu, T.2
Kuroda, S.3
Atsumi, T.4
Oguni, K.5
-
4
-
-
0025962072
-
Frosting performance of tube fin heat exchanger with wavy and corrugated fins
-
S.N. Kondepudi, and D.L. O'Neal Frosting performance of tube fin heat exchanger with wavy and corrugated fins Exp. Therm. Fluid Sci. 4 1991 613 618
-
(1991)
Exp. Therm. Fluid Sci.
, vol.4
, pp. 613-618
-
-
Kondepudi, S.N.1
O'Neal, D.L.2
-
5
-
-
39549088476
-
Frost retardation of an air-source heat pump by the hot gas bypass method
-
DOI 10.1016/j.ijrefrig.2007.05.006, PII S0140700707000849
-
J.S. Byun, J. Lee, and C.D. Jeon Frost retardation of an air-source heat pump by the hot gas bypass method Int. J. Refrig. 31 2008 328 334 (Pubitemid 351282402)
-
(2008)
International Journal of Refrigeration
, vol.31
, Issue.2
, pp. 328-334
-
-
Byun, J.-S.1
Lee, J.2
Jeon, C.-D.3
-
6
-
-
4344566422
-
Experiment investigation of reverse cycle defrosting methods on air source heat pump with TXV as the throttle regulator
-
Y.J. Ding, G.Y. Ma, and J. Yi Experiment investigation of reverse cycle defrosting methods on air source heat pump with TXV as the throttle regulator Int. J. Refrig. 27 2004 671 678
-
(2004)
Int. J. Refrig.
, vol.27
, pp. 671-678
-
-
Ding, Y.J.1
Ma, G.Y.2
Yi, J.3
-
7
-
-
10044231379
-
Effect of fan-starting methods on the reverse-cycle defrost performance of an air-source heat pump
-
D. Huang, and X.L. Yuan Effect of fan-starting methods on the reverse-cycle defrost performance of an air-source heat pump Int. J. Refrig. 27 2004 107 112
-
(2004)
Int. J. Refrig.
, vol.27
, pp. 107-112
-
-
Huang, D.1
Yuan, X.L.2
-
8
-
-
34247117965
-
Dynamic characteristics of an air-to-water heat pump under frosting/defrosting conditions
-
DOI 10.1016/j.applthermaleng.2006.12.003, PII S1359431106004339
-
D. Huang, Z.L. He, and X.L. Yuan Dynamic characteristics of an air-to-water heat pump under frosting/defrosting conditions Appl. Therm. Eng. 27 2007 1996 2002 (Pubitemid 46603301)
-
(2007)
Applied Thermal Engineering
, vol.27
, Issue.11-12
, pp. 1996-2002
-
-
Huang, D.1
He, Z.L.2
Yuan, X.L.3
-
9
-
-
2942749983
-
A study on the performance of the airside heat exchanger under frosting in an air source heat pump water heater/chiller unit
-
DOI 10.1016/j.ijheatmasstransfer.2004.03.013, PII S0017931004001097
-
Y. Yao, Y.Q. Jiang, S.M. Deng, and Z.L. Ma A study on the performance of the airside heat exchanger under frosting in an air source heat pump water heater/chiller unit Int. J. Heat Mass Transf. 47 2004 3745 3756 (Pubitemid 38790924)
-
(2004)
International Journal of Heat and Mass Transfer
, vol.47
, Issue.17-18
, pp. 3745-3756
-
-
Yao, Y.1
Jiang, Y.2
Deng, S.3
Ma, Z.4
-
10
-
-
0036679898
-
Experimental investigation on the drop-in performance of R407C as a substitute for R22 in a screw chiller with shell-and-tube heat exchangers
-
DOI 10.1016/S0140-7007(01)00056-1, PII S0140700701000561
-
D.Y. Lee, Y. Ahn, Y. Kim, Y. Kim, Y.S. Chang, and L. Nam Experimental investigation on the drop-in performance of R407C as a substitute for R22 in a screw chiller with shell-and-tube heat exchangers Int. J. Refrig. 25 2002 575 585 (Pubitemid 34771868)
-
(2002)
International Journal of Refrigeration
, vol.25
, Issue.5
, pp. 575-585
-
-
Lee, D.-Y.1
Ahn, Y.2
Kim, Y.3
Kim, Y.4
Chang, Y.-S.5
Nam, L.6
-
11
-
-
0023844053
-
Describing the uncertainties in experimental results
-
R.J. Moffat Describing the uncertainties in experimental results Exp. Therm. Fluid Sci. 1 1988 3 17
-
(1988)
Exp. Therm. Fluid Sci.
, vol.1
, pp. 3-17
-
-
Moffat, R.J.1
-
12
-
-
80052259995
-
Defrosting method adopting dual hot gas bypass for an air-to-air heat pump
-
Hwan-Jong Choi, and Byung-Soon Kim Defrosting method adopting dual hot gas bypass for an air-to-air heat pump Appl. Energy 88 2011 4544 4555
-
(2011)
Appl. Energy
, vol.88
, pp. 4544-4555
-
-
Choi, H.-J.1
Kim, B.-S.2
|