메뉴 건너뛰기




Volumn 27, Issue 11-12, 2007, Pages 1996-2002

Dynamic characteristics of an air-to-water heat pump under frosting/defrosting conditions

Author keywords

Defrosting; Frosting; Heat pump; Hunting; Maldistribution

Indexed keywords

DEFROSTING; EVAPORATORS; FROST EFFECTS; THERMAL EXPANSION; THERMOSTATS; VALVES (MECHANICAL);

EID: 34247117965     PISSN: 13594311     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.applthermaleng.2006.12.003     Document Type: Article
Times cited : (37)

References (12)
  • 1
    • 0022950916 scopus 로고
    • Shorting the defrost time on a heat-pump air conditioner
    • Kuwahara E., Kawamura T., and Yamazaki M. Shorting the defrost time on a heat-pump air conditioner. ASHRAE Transaction 92 (1985) 20-29
    • (1985) ASHRAE Transaction , vol.92 , pp. 20-29
    • Kuwahara, E.1    Kawamura, T.2    Yamazaki, M.3
  • 2
    • 2142800708 scopus 로고
    • Effects of outdoor coil fan pre-start on pressure transient during the reverse cycle defrost of a heat pump
    • Anand N.K., Schliesing J.S., O'Neal D.L., et al. Effects of outdoor coil fan pre-start on pressure transient during the reverse cycle defrost of a heat pump. ASHRAE Transaction 95 (1989) 699-704
    • (1989) ASHRAE Transaction , vol.95 , pp. 699-704
    • Anand, N.K.1    Schliesing, J.S.2    O'Neal, D.L.3
  • 3
    • 0000209811 scopus 로고
    • Refrigeration system dynamics during the reverse cycle defrost
    • O'Neal D.L., Pterson K.T., Anand N.K., et al. Refrigeration system dynamics during the reverse cycle defrost. ASHRAE Transaction 95 (1989) 689-698
    • (1989) ASHRAE Transaction , vol.95 , pp. 689-698
    • O'Neal, D.L.1    Pterson, K.T.2    Anand, N.K.3
  • 4
    • 0025840669 scopus 로고
    • Effect of short-tube orifice size on the performance of an air source heat pump during the reverse-cycle defrost
    • O'Neal D.L., Pterson K.T., and Anand N.K. Effect of short-tube orifice size on the performance of an air source heat pump during the reverse-cycle defrost. International Journal of Refrigeration 14 (1991) 52-57
    • (1991) International Journal of Refrigeration , vol.14 , pp. 52-57
    • O'Neal, D.L.1    Pterson, K.T.2    Anand, N.K.3
  • 5
    • 0029250487 scopus 로고
    • Defrost cycle performance for an air-source heat pump with a scroll and a reciprocating compressor
    • Payne V., and O'Neal D.L. Defrost cycle performance for an air-source heat pump with a scroll and a reciprocating compressor. International Journal of Refrigeration 18 (1995) 107-112
    • (1995) International Journal of Refrigeration , vol.18 , pp. 107-112
    • Payne, V.1    O'Neal, D.L.2
  • 6
    • 0029698127 scopus 로고    scopus 로고
    • Impact of the suction line accumulator on the frost/defrost performance of an air-source heat pump with a scroll compressor
    • Nutter D.W., O'Neal D.L., and Payne W.V. Impact of the suction line accumulator on the frost/defrost performance of an air-source heat pump with a scroll compressor. ASHRAE Transaction 102 (1996) 689-698
    • (1996) ASHRAE Transaction , vol.102 , pp. 689-698
    • Nutter, D.W.1    O'Neal, D.L.2    Payne, W.V.3
  • 7
    • 0036455361 scopus 로고    scopus 로고
    • Frost/defrost performance of a three-row fin staged heat pump evaporator
    • Watters R.J., O'Neal D.L., and Yang J.X. Frost/defrost performance of a three-row fin staged heat pump evaporator. ASHRAE Transaction 108 (2002) 318-329
    • (2002) ASHRAE Transaction , vol.108 , pp. 318-329
    • Watters, R.J.1    O'Neal, D.L.2    Yang, J.X.3
  • 8
    • 0036883435 scopus 로고    scopus 로고
    • Effect of surface treatments on the frosting/defrosting behavior of a fin-tube heat exchanger
    • Jhee S., Lee K.S., and Kim W.S. Effect of surface treatments on the frosting/defrosting behavior of a fin-tube heat exchanger. International Journal of Refrigeration 25 (2002) 1047-1053
    • (2002) International Journal of Refrigeration , vol.25 , pp. 1047-1053
    • Jhee, S.1    Lee, K.S.2    Kim, W.S.3
  • 9
    • 4344566422 scopus 로고    scopus 로고
    • Experiment investigation of reverse cycle defrosting methods on air source heat pump with TXV as the throttle regulator
    • Ding Y., Ma G., and Yi J. Experiment investigation of reverse cycle defrosting methods on air source heat pump with TXV as the throttle regulator. International Journal of Refrigeration 27 6 (2004) 671-678
    • (2004) International Journal of Refrigeration , vol.27 , Issue.6 , pp. 671-678
    • Ding, Y.1    Ma, G.2    Yi, J.3
  • 10
    • 10044231379 scopus 로고    scopus 로고
    • Effect of fan-starting methods on the reverse-cycle defrost performance of an air-source heat pump
    • Huang D., Yuan X.L., et al. Effect of fan-starting methods on the reverse-cycle defrost performance of an air-source heat pump. International Journal of Refrigeration 27 (2004) 107-112
    • (2004) International Journal of Refrigeration , vol.27 , pp. 107-112
    • Huang, D.1    Yuan, X.L.2
  • 11
    • 0023844053 scopus 로고
    • Describing the uncertainties in experimental results
    • Moffat R.J. Describing the uncertainties in experimental results. Experimental Thermal and Fluid Science 1 (1988) 3-17
    • (1988) Experimental Thermal and Fluid Science , vol.1 , pp. 3-17
    • Moffat, R.J.1
  • 12
    • 0002011067 scopus 로고
    • The MSS line - A new approach to the hunting problem
    • Huelle Z.R. The MSS line - A new approach to the hunting problem. ASHRAE Journal 14 8 (1972) 43-46
    • (1972) ASHRAE Journal , vol.14 , Issue.8 , pp. 43-46
    • Huelle, Z.R.1