메뉴 건너뛰기




Volumn 8, Issue 3, 2013, Pages 295-309

Arterial spin labeling magnetic resonance imaging: Intracranial and emerging extracranial applications

Author keywords

Arterial Spin Labeling; MR imaging; Perfusion imaging

Indexed keywords

ARTERIAL SPIN LABELING MAGNETIC RESONANCE IMAGING; ARTICLE; BRAIN BLOOD FLOW; BRAIN PERFUSION; CEREBRAL METABOLIC RATE OF OXYGEN; HEART PERFUSION; HUMAN; KIDNEY PERFUSION; LUNG PERFUSION; MUSCLE PERFUSION; NUCLEAR MAGNETIC RESONANCE IMAGING; OXYGEN EXTRACTION FRACTION; PRIORITY JOURNAL; SCINTIGRAPHY;

EID: 84879605901     PISSN: 15568598     EISSN: 18799809     Source Type: Journal    
DOI: 10.1016/j.cpet.2013.03.003     Document Type: Review
Times cited : (1)

References (94)
  • 1
    • 33645289942 scopus 로고    scopus 로고
    • Gadolinium-a specific trigger for the development of nephrogenic fibrosing dermopathy and nephrogenic systemic fibrosis?
    • T. Grobner Gadolinium-a specific trigger for the development of nephrogenic fibrosing dermopathy and nephrogenic systemic fibrosis? Nephrol Dial Transplant 21 2006 1104 1108
    • (2006) Nephrol Dial Transplant , vol.21 , pp. 1104-1108
    • Grobner, T.1
  • 2
    • 1842418806 scopus 로고    scopus 로고
    • Flow territory mapping of the cerebral arteries with regional perfusion MRI
    • J. Hendrikse, G.J. van der, and H. Lu Flow territory mapping of the cerebral arteries with regional perfusion MRI Stroke 35 2004 882 887
    • (2004) Stroke , vol.35 , pp. 882-887
    • Hendrikse, J.1    Van Der, G.J.2    Lu, H.3
  • 3
    • 58149328543 scopus 로고    scopus 로고
    • Territorial arterial spin labeling in the assessment of collateral circulation: Comparison with digital subtraction angiography
    • S.M. Chng, E.T. Petersen, and I. Zimine Territorial arterial spin labeling in the assessment of collateral circulation: comparison with digital subtraction angiography Stroke 39 2008 3248 3254
    • (2008) Stroke , vol.39 , pp. 3248-3254
    • Chng, S.M.1    Petersen, E.T.2    Zimine, I.3
  • 4
    • 49049091751 scopus 로고    scopus 로고
    • Quantitative evaluation of oxygenation in venous vessels using T2-relaxation-under-spin-tagging MRI
    • H. Lu, and Y. Ge Quantitative evaluation of oxygenation in venous vessels using T2-relaxation-under-spin-tagging MRI Magn Reson Med 60 2008 357 363
    • (2008) Magn Reson Med , vol.60 , pp. 357-363
    • Lu, H.1    Ge, Y.2
  • 5
    • 33744951217 scopus 로고    scopus 로고
    • Velocity-selective arterial spin labeling
    • E.C. Wong, M. Cronin, and W.C. Wu Velocity-selective arterial spin labeling Magn Reson Med 55 2006 1334 1341
    • (2006) Magn Reson Med , vol.55 , pp. 1334-1341
    • Wong, E.C.1    Cronin, M.2    Wu, W.C.3
  • 6
    • 81355161550 scopus 로고    scopus 로고
    • Quantitative Imaging of Extraction of Oxygen and Tissue Consumption (QUIXOTIC) using venular-targeted velocity-selective spin labeling
    • D.S. Bolar, B.R. Rosen, and A.G. Sorensen Quantitative Imaging of Extraction of Oxygen and Tissue Consumption (QUIXOTIC) using venular-targeted velocity-selective spin labeling Magn Reson Med 66 2011 1550 1562
    • (2011) Magn Reson Med , vol.66 , pp. 1550-1562
    • Bolar, D.S.1    Rosen, B.R.2    Sorensen, A.G.3
  • 7
    • 84856998966 scopus 로고    scopus 로고
    • Magnetic resonance imaging of resting OEF and CMRO(2) using a generalized calibration model for hypercapnia and hyperoxia
    • C.J. Gauthier, and R.D. Hoge Magnetic resonance imaging of resting OEF and CMRO(2) using a generalized calibration model for hypercapnia and hyperoxia Neuroimage 60 2012 1212 1225
    • (2012) Neuroimage , vol.60 , pp. 1212-1225
    • Gauthier, C.J.1    Hoge, R.D.2
  • 8
    • 0026542167 scopus 로고
    • Magnetic resonance imaging of perfusion using spin inversion of arterial water
    • D.S. Williams, J.A. Detre, and J.S. Leigh Magnetic resonance imaging of perfusion using spin inversion of arterial water Proc Natl Acad Sci U S A 89 1992 212 216
    • (1992) Proc Natl Acad Sci U S A , vol.89 , pp. 212-216
    • Williams, D.S.1    Detre, J.A.2    Leigh, J.S.3
  • 10
    • 0031821720 scopus 로고    scopus 로고
    • A general kinetic model for quantitative perfusion imaging with arterial spin labeling
    • R.B. Buxton, L.R. Frank, and E.C. Wong A general kinetic model for quantitative perfusion imaging with arterial spin labeling Magn Reson Med 40 1998 383 396
    • (1998) Magn Reson Med , vol.40 , pp. 383-396
    • Buxton, R.B.1    Frank, L.R.2    Wong, E.C.3
  • 11
    • 84939682609 scopus 로고
    • The nitrous oxide method for the quantitative determination of cerebral blood flow in man: Theory, procedure and normal values
    • S.S. Kety, and C.F. Schmidt The nitrous oxide method for the quantitative determination of cerebral blood flow in man: theory, procedure and normal values J Clin Invest 27 1948 476 483
    • (1948) J Clin Invest , vol.27 , pp. 476-483
    • Kety, S.S.1    Schmidt, C.F.2
  • 12
    • 0027936294 scopus 로고
    • Qualitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency
    • R.R. Edelman, B. Siewert, and D.G. Darby Qualitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency Radiology 192 1994 513 520
    • (1994) Radiology , vol.192 , pp. 513-520
    • Edelman, R.R.1    Siewert, B.2    Darby, D.G.3
  • 13
    • 33747590330 scopus 로고    scopus 로고
    • Non-invasive measurement of perfusion: A critical review of arterial spin labelling techniques
    • E.T. Petersen, I. Zimine, and Y.C. Ho Non-invasive measurement of perfusion: a critical review of arterial spin labelling techniques Br J Radiol 79 2006 688 701
    • (2006) Br J Radiol , vol.79 , pp. 688-701
    • Petersen, E.T.1    Zimine, I.2    Ho, Y.C.3
  • 14
    • 0027283766 scopus 로고
    • Magnetic resonance imaging of perfusion in the isolated rat heart using spin inversion of arterial water
    • D.S. Williams, D.J. Grandis, and W. Zhang Magnetic resonance imaging of perfusion in the isolated rat heart using spin inversion of arterial water Magn Reson Med 30 1993 361 365
    • (1993) Magn Reson Med , vol.30 , pp. 361-365
    • Williams, D.S.1    Grandis, D.J.2    Zhang, W.3
  • 15
    • 15944405346 scopus 로고    scopus 로고
    • Amplitude-modulated continuous arterial spin-labeling 3.0-T perfusion MR imaging with a single coil: Feasibility study
    • J. Wang, Y. Zhang, and R.L. Wolf Amplitude-modulated continuous arterial spin-labeling 3.0-T perfusion MR imaging with a single coil: feasibility study Radiology 235 2005 218 228
    • (2005) Radiology , vol.235 , pp. 218-228
    • Wang, J.1    Zhang, Y.2    Wolf, R.L.3
  • 16
    • 57149104587 scopus 로고    scopus 로고
    • Continuous flow-driven inversion for arterial spin labeling using pulsed radio frequency and gradient fields
    • W. Dai, D. Garcia, and C. de Bazelaire Continuous flow-driven inversion for arterial spin labeling using pulsed radio frequency and gradient fields Magn Reson Med 60 2008 1488 1497
    • (2008) Magn Reson Med , vol.60 , pp. 1488-1497
    • Dai, W.1    Garcia, D.2    De Bazelaire, C.3
  • 17
    • 84861713587 scopus 로고    scopus 로고
    • CBF measurements using multidelay pseudocontinuous and velocity-selective arterial spin labeling in patients with long arterial transit delays: Comparison with xenon CT CBF
    • D. Qiu, M. Straka, and Z. Zun CBF measurements using multidelay pseudocontinuous and velocity-selective arterial spin labeling in patients with long arterial transit delays: comparison with xenon CT CBF J Magn Reson Imaging 36 2012 110 119
    • (2012) J Magn Reson Imaging , vol.36 , pp. 110-119
    • Qiu, D.1    Straka, M.2    Zun, Z.3
  • 18
    • 84865464634 scopus 로고    scopus 로고
    • Arterial spin labeling MRI study of age and gender effects on brain perfusion hemodynamics
    • Y. Liu, X. Zhu, and D. Feinberg Arterial spin labeling MRI study of age and gender effects on brain perfusion hemodynamics Magn Reson Med 68 2012 912 922
    • (2012) Magn Reson Med , vol.68 , pp. 912-922
    • Liu, Y.1    Zhu, X.2    Feinberg, D.3
  • 19
    • 0025056547 scopus 로고
    • Cerebral blood flow, blood volume and oxygen utilization. Normal values and effect of age
    • K.L. Leenders, D. Perani, and A.A. Lammertsma Cerebral blood flow, blood volume and oxygen utilization. Normal values and effect of age Brain 113 1990 27 47
    • (1990) Brain , vol.113 , pp. 27-47
    • Leenders, K.L.1    Perani, D.2    Lammertsma, A.A.3
  • 20
    • 0034108310 scopus 로고    scopus 로고
    • Magnetic resonance perfusion imaging in acute ischemic stroke using continuous arterial spin labeling
    • J.A. Chalela, D.C. Alsop, and J.B. Gonzalez-Atavales Magnetic resonance perfusion imaging in acute ischemic stroke using continuous arterial spin labeling Stroke 31 2000 680 687
    • (2000) Stroke , vol.31 , pp. 680-687
    • Chalela, J.A.1    Alsop, D.C.2    Gonzalez-Atavales, J.B.3
  • 21
    • 78649638981 scopus 로고    scopus 로고
    • Multiple inflow pulsed arterial spin-labeling reveals delays in the arterial arrival time in minor stroke and transient ischemic attack
    • B.J. MacIntosh, A.C. Lindsay, and I. Kylintireas Multiple inflow pulsed arterial spin-labeling reveals delays in the arterial arrival time in minor stroke and transient ischemic attack AJNR Am J Neuroradiol 31 2010 1892 1894
    • (2010) AJNR Am J Neuroradiol , vol.31 , pp. 1892-1894
    • Macintosh, B.J.1    Lindsay, A.C.2    Kylintireas, I.3
  • 22
    • 0030615065 scopus 로고    scopus 로고
    • Comparison of EPISTAR and T2*-weighted gadolinium-enhanced perfusion imaging in patients with acute cerebral ischemia
    • B. Siewert, G. Schlaug, and R.R. Edelman Comparison of EPISTAR and T2*-weighted gadolinium-enhanced perfusion imaging in patients with acute cerebral ischemia Neurology 48 1997 673 679
    • (1997) Neurology , vol.48 , pp. 673-679
    • Siewert, B.1    Schlaug, G.2    Edelman, R.R.3
  • 23
    • 77953955149 scopus 로고    scopus 로고
    • Symptomatic carotid artery stenosis: Impairment of cerebral autoregulation measured at the brain tissue level with arterial spin-labeling MR imaging
    • R.P. Bokkers, M.J. van Osch, and H.B. van der Worp Symptomatic carotid artery stenosis: impairment of cerebral autoregulation measured at the brain tissue level with arterial spin-labeling MR imaging Radiology 256 2010 201 208
    • (2010) Radiology , vol.256 , pp. 201-208
    • Bokkers, R.P.1    Van Osch, M.J.2    Van Der Worp, H.B.3
  • 24
    • 0036191571 scopus 로고    scopus 로고
    • Variability of cerebral blood volume and oxygen extraction: Stages of cerebral haemodynamic impairment revisited
    • C.P. Derdeyn, T.O. Videen, and K.D. Yundt Variability of cerebral blood volume and oxygen extraction: stages of cerebral haemodynamic impairment revisited Brain 125 2002 595 607
    • (2002) Brain , vol.125 , pp. 595-607
    • Derdeyn, C.P.1    Videen, T.O.2    Yundt, K.D.3
  • 25
    • 0026063830 scopus 로고
    • Cerebral hemodynamics in ischemic cerebrovascular disease
    • W.J. Powers Cerebral hemodynamics in ischemic cerebrovascular disease Ann Neurol 29 1991 231 240
    • (1991) Ann Neurol , vol.29 , pp. 231-240
    • Powers, W.J.1
  • 26
    • 65549160833 scopus 로고    scopus 로고
    • Relation between cerebral perfusion territories and location of cerebral infarcts
    • J. Hendrikse, E.T. Petersen, and A. Cheze Relation between cerebral perfusion territories and location of cerebral infarcts Stroke 40 2009 1617 1622
    • (2009) Stroke , vol.40 , pp. 1617-1622
    • Hendrikse, J.1    Petersen, E.T.2    Cheze, A.3
  • 27
    • 33846409445 scopus 로고    scopus 로고
    • Symptomatic carotid artery occlusion: Flow territories of major brain-feeding arteries
    • P.J. van Laar, J. Hendrikse, and C.J. Klijn Symptomatic carotid artery occlusion: flow territories of major brain-feeding arteries Radiology 242 2007 526 534
    • (2007) Radiology , vol.242 , pp. 526-534
    • Van Laar, P.J.1    Hendrikse, J.2    Klijn, C.J.3
  • 28
    • 29944438531 scopus 로고    scopus 로고
    • Application of regional perfusion imaging to extra-intracranial bypass surgery and severe stenoses
    • X. Golay, J. Hendrikse, and G.J. van der Application of regional perfusion imaging to extra-intracranial bypass surgery and severe stenoses J Neuroradiol 32 2005 321 324
    • (2005) J Neuroradiol , vol.32 , pp. 321-324
    • Golay, X.1    Hendrikse, J.2    Van Der, G.J.3
  • 29
    • 84860225375 scopus 로고    scopus 로고
    • Whole-brain arterial spin labeling perfusion MRI in patients with acute stroke
    • R.P. Bokkers, D.A. Hernandez, and J.G. Merino Whole-brain arterial spin labeling perfusion MRI in patients with acute stroke Stroke 43 2012 1290 1294
    • (2012) Stroke , vol.43 , pp. 1290-1294
    • Bokkers, R.P.1    Hernandez, D.A.2    Merino, J.G.3
  • 30
    • 77958505934 scopus 로고    scopus 로고
    • Combined use of pulsed arterial spin-labeling and susceptibility-weighted imaging in stroke at 3T
    • M. Viallon, S. Altrichter, and V.M. Pereira Combined use of pulsed arterial spin-labeling and susceptibility-weighted imaging in stroke at 3T Eur Neurol 64 2010 286 296
    • (2010) Eur Neurol , vol.64 , pp. 286-296
    • Viallon, M.1    Altrichter, S.2    Pereira, V.M.3
  • 31
    • 84861713584 scopus 로고    scopus 로고
    • Comparison of arterial spin labeling and bolus perfusion-weighted imaging for detecting mismatch in acute stroke
    • G. Zaharchuk, I.S. EI Mogy, and N.J. Fischbein Comparison of arterial spin labeling and bolus perfusion-weighted imaging for detecting mismatch in acute stroke Stroke 43 2012 1843 1848
    • (2012) Stroke , vol.43 , pp. 1843-1848
    • Zaharchuk, G.1    Ei Mogy, I.S.2    Fischbein, N.J.3
  • 32
    • 16544372976 scopus 로고    scopus 로고
    • Internal carotid artery occlusion assessed at pulsed arterial spin-labeling perfusion MR imaging at multiple delay times
    • J. Hendrikse, M.J. van Osch, and D.R. Rutgers Internal carotid artery occlusion assessed at pulsed arterial spin-labeling perfusion MR imaging at multiple delay times Radiology 233 2004 899 904
    • (2004) Radiology , vol.233 , pp. 899-904
    • Hendrikse, J.1    Van Osch, M.J.2    Rutgers, D.R.3
  • 33
    • 32544441071 scopus 로고    scopus 로고
    • Model-free arterial spin labeling quantification approach for perfusion MRI
    • E.T. Petersen, T. Lim, and X. Golay Model-free arterial spin labeling quantification approach for perfusion MRI Magn Reson Med 55 2006 219 232
    • (2006) Magn Reson Med , vol.55 , pp. 219-232
    • Petersen, E.T.1    Lim, T.2    Golay, X.3
  • 34
    • 0034757715 scopus 로고    scopus 로고
    • Arterial spin labeling in combination with a look-locker sampling strategy: Inflow turbo-sampling EPI-FAIR (ITS-FAIR)
    • M. Gunther, M. Bock, and L.R. Schad Arterial spin labeling in combination with a look-locker sampling strategy: inflow turbo-sampling EPI-FAIR (ITS-FAIR) Magn Reson Med 46 2001 974 984
    • (2001) Magn Reson Med , vol.46 , pp. 974-984
    • Gunther, M.1    Bock, M.2    Schad, L.R.3
  • 35
    • 80052419889 scopus 로고    scopus 로고
    • Arterial spin-labeling MRI can identify the presence and intensity of collateral perfusion in patients with moyamoya disease
    • G. Zaharchuk, H.M. Do, and M.P. Marks Arterial spin-labeling MRI can identify the presence and intensity of collateral perfusion in patients with moyamoya disease Stroke 42 2011 2485 2491
    • (2011) Stroke , vol.42 , pp. 2485-2491
    • Zaharchuk, G.1    Do, H.M.2    Marks, M.P.3
  • 36
    • 84878715284 scopus 로고    scopus 로고
    • Arterial spin-labeling magnetic resonance imaging after revascularization of moyamoya disease
    • [Epub ahead of print]
    • T. Sugino, T. Mikami, and K. Miyata Arterial spin-labeling magnetic resonance imaging after revascularization of moyamoya disease J Stroke Cerebrovasc Dis 2012 [Epub ahead of print]
    • (2012) J Stroke Cerebrovasc Dis
    • Sugino, T.1    Mikami, T.2    Miyata, K.3
  • 37
    • 58149489492 scopus 로고    scopus 로고
    • Delayed intracerebral hemorrhage after superficial temporal artery-middle cerebral artery anastomosis in a patient with moyamoya disease: Possible involvement of cerebral hyperperfusion and increased vascular permeability
    • M. Fujimura, H. Shimizu, and S. Mugikura Delayed intracerebral hemorrhage after superficial temporal artery-middle cerebral artery anastomosis in a patient with moyamoya disease: possible involvement of cerebral hyperperfusion and increased vascular permeability Surg Neurol 71 2009 223 227
    • (2009) Surg Neurol , vol.71 , pp. 223-227
    • Fujimura, M.1    Shimizu, H.2    Mugikura, S.3
  • 38
    • 79952899669 scopus 로고    scopus 로고
    • Significance of focal cerebral hyperperfusion as a cause of transient neurologic deterioration after extracranial-intracranial bypass for moyamoya disease: Comparative study with non-moyamoya patients using N-isopropyl-p-[(123) I]iodoamphetamine single-photon emission computed tomography
    • M. Fujimura, H. Shimizu, and T. Inoue Significance of focal cerebral hyperperfusion as a cause of transient neurologic deterioration after extracranial-intracranial bypass for moyamoya disease: comparative study with non-moyamoya patients using N-isopropyl-p-[(123)I]iodoamphetamine single-photon emission computed tomography Neurosurgery 68 2011 957 964
    • (2011) Neurosurgery , vol.68 , pp. 957-964
    • Fujimura, M.1    Shimizu, H.2    Inoue, T.3
  • 39
    • 42449105196 scopus 로고    scopus 로고
    • Arteriovenous shunt visualization in arteriovenous malformations with arterial spin-labeling MR imaging
    • R.L. Wolf, J. Wang, and J.A. Detre Arteriovenous shunt visualization in arteriovenous malformations with arterial spin-labeling MR imaging AJNR Am J Neuroradiol 29 2008 681 687
    • (2008) AJNR Am J Neuroradiol , vol.29 , pp. 681-687
    • Wolf, R.L.1    Wang, J.2    Detre, J.A.3
  • 40
    • 79954415402 scopus 로고    scopus 로고
    • Flow-sensitive alternating inversion recovery (fair) imaging for retrograde cortical venous drainage related to intracranial dural arteriovenous fistula
    • K. Noguchi, N. Kuwayama, and M. Kubo Flow-sensitive alternating inversion recovery (fair) imaging for retrograde cortical venous drainage related to intracranial dural arteriovenous fistula Neuroradiology 53 2011 153 158
    • (2011) Neuroradiology , vol.53 , pp. 153-158
    • Noguchi, K.1    Kuwayama, N.2    Kubo, M.3
  • 41
    • 84856112752 scopus 로고    scopus 로고
    • Identification of venous signal on arterial spin labeling improves diagnosis of dural arteriovenous fistulas and small arteriovenous malformations
    • T.T. Le, N.J. Fischbein, and J.B. Andre Identification of venous signal on arterial spin labeling improves diagnosis of dural arteriovenous fistulas and small arteriovenous malformations AJNR Am J Neuroradiol 33 2012 61 68
    • (2012) AJNR Am J Neuroradiol , vol.33 , pp. 61-68
    • Le, T.T.1    Fischbein, N.J.2    Andre, J.B.3
  • 42
    • 77249147459 scopus 로고    scopus 로고
    • Cerebral arteriovenous malformations at 3.0 T: Intraindividual comparative study of 4D-MRA in combination with selective arterial spin labeling and digital subtraction angiography
    • G.M. Kukuk, D.R. Hadizadeh, and A. Bostrom Cerebral arteriovenous malformations at 3.0 T: intraindividual comparative study of 4D-MRA in combination with selective arterial spin labeling and digital subtraction angiography Invest Radiol 45 2010 126 132
    • (2010) Invest Radiol , vol.45 , pp. 126-132
    • Kukuk, G.M.1    Hadizadeh, D.R.2    Bostrom, A.3
  • 43
    • 78650824503 scopus 로고    scopus 로고
    • Response of arteriovenous malformations to gamma knife therapy evaluated with pulsed arterial spin-labeling MRI perfusion
    • J.M. Pollock, C.T. Whitlow, and J. Simonds Response of arteriovenous malformations to gamma knife therapy evaluated with pulsed arterial spin-labeling MRI perfusion AJR Am J Roentgenol 196 2011 15 22
    • (2011) AJR Am J Roentgenol , vol.196 , pp. 15-22
    • Pollock, J.M.1    Whitlow, C.T.2    Simonds, J.3
  • 44
    • 0042844535 scopus 로고    scopus 로고
    • Quantification of blood flow in brain tumors: Comparison of arterial spin labeling and dynamic susceptibility-weighted contrast-enhanced MR imaging
    • C. Warmuth, M. Gunther, and C. Zimmer Quantification of blood flow in brain tumors: comparison of arterial spin labeling and dynamic susceptibility-weighted contrast-enhanced MR imaging Radiology 228 2003 523 532
    • (2003) Radiology , vol.228 , pp. 523-532
    • Warmuth, C.1    Gunther, M.2    Zimmer, C.3
  • 45
    • 84866020207 scopus 로고    scopus 로고
    • Arterial spin labeling of hemangioblastoma: Differentiation from metastatic brain tumors based on quantitative blood flow measurement
    • K. Yamashita, T. Yoshiura, and A. Hiwatashi Arterial spin labeling of hemangioblastoma: differentiation from metastatic brain tumors based on quantitative blood flow measurement Neuroradiology 54 2012 809 813
    • (2012) Neuroradiology , vol.54 , pp. 809-813
    • Yamashita, K.1    Yoshiura, T.2    Hiwatashi, A.3
  • 46
    • 84873741459 scopus 로고    scopus 로고
    • Differentiating primary CNS lymphoma from glioblastoma multiforme: Assessment using arterial spin labeling, diffusion-weighted imaging, and (18)F-fluorodeoxyglucose positron emission tomography
    • K. Yamashita, T. Yoshiura, and A. Hiwatashi Differentiating primary CNS lymphoma from glioblastoma multiforme: assessment using arterial spin labeling, diffusion-weighted imaging, and (18)F-fluorodeoxyglucose positron emission tomography Neuroradiology 55 2 2012 135 143
    • (2012) Neuroradiology , vol.55 , Issue.2 , pp. 135-143
    • Yamashita, K.1    Yoshiura, T.2    Hiwatashi, A.3
  • 47
    • 84879601808 scopus 로고    scopus 로고
    • Presurgical assessment of the feeding vasculature in extra-axial tumors with superselective arterial spin labeling
    • Montreal (Québec)
    • Helle M, Janssen O. Presurgical assessment of the feeding vasculature in extra-axial tumors with superselective arterial spin labeling. Proceedings of the 19th annual meeting ISMRM. Montreal (Québec): 2011.
    • (2011) Proceedings of the 19th Annual Meeting ISMRM
    • Helle, M.1    Janssen, O.2
  • 48
    • 56449126967 scopus 로고    scopus 로고
    • Usefulness of pulsed arterial spin labeling MR imaging in mesial temporal lobe epilepsy
    • Y.M. Lim, Y.W. Cho, and S. Shamim Usefulness of pulsed arterial spin labeling MR imaging in mesial temporal lobe epilepsy Epilepsy Res 82 2008 183 189
    • (2008) Epilepsy Res , vol.82 , pp. 183-189
    • Lim, Y.M.1    Cho, Y.W.2    Shamim, S.3
  • 49
    • 0034907799 scopus 로고    scopus 로고
    • Detection of mesial temporal lobe hypoperfusion in patients with temporal lobe epilepsy by use of arterial spin labeled perfusion MR imaging
    • R.L. Wolf, D.C. Alsop, and I. Levy-Reis Detection of mesial temporal lobe hypoperfusion in patients with temporal lobe epilepsy by use of arterial spin labeled perfusion MR imaging AJNR Am J Neuroradiol 22 2001 1334 1341
    • (2001) AJNR Am J Neuroradiol , vol.22 , pp. 1334-1341
    • Wolf, R.L.1    Alsop, D.C.2    Levy-Reis, I.3
  • 50
    • 77649190354 scopus 로고    scopus 로고
    • Interictal arterial spin-labeling MRI perfusion in intractable epilepsy
    • N. Pendse, M. Wissmeyer, and S. Altrichter Interictal arterial spin-labeling MRI perfusion in intractable epilepsy J Neuroradiol 37 2010 60 63
    • (2010) J Neuroradiol , vol.37 , pp. 60-63
    • Pendse, N.1    Wissmeyer, M.2    Altrichter, S.3
  • 51
    • 84862869359 scopus 로고    scopus 로고
    • Ictal focal hyperperfusion demonstrated by arterial spin-labeling perfusion MRI in partial epilepsy status
    • M. Oishi, G. Ishida, and K. Morii Ictal focal hyperperfusion demonstrated by arterial spin-labeling perfusion MRI in partial epilepsy status Neuroradiology 54 2012 653 656
    • (2012) Neuroradiology , vol.54 , pp. 653-656
    • Oishi, M.1    Ishida, G.2    Morii, K.3
  • 52
    • 53249122892 scopus 로고    scopus 로고
    • Pulsed-arterial-spin-labeling perfusion 3T MRI following single seizure: A first case report study
    • F. Pizzini, P. Farace, and T. Zanoni Pulsed-arterial-spin-labeling perfusion 3T MRI following single seizure: a first case report study Epilepsy Res 81 2008 225 227
    • (2008) Epilepsy Res , vol.81 , pp. 225-227
    • Pizzini, F.1    Farace, P.2    Zanoni, T.3
  • 53
    • 84856393576 scopus 로고    scopus 로고
    • Localisation value of ictal arterial spin-labelled sequences in partial seizures
    • M. Toledo, J. Munuera, and X. Salas-Puig Localisation value of ictal arterial spin-labelled sequences in partial seizures Epileptic Disord 13 2011 336 339
    • (2011) Epileptic Disord , vol.13 , pp. 336-339
    • Toledo, M.1    Munuera, J.2    Salas-Puig, X.3
  • 54
    • 0033976957 scopus 로고    scopus 로고
    • Assessment of cerebral blood flow in Alzheimer's disease by spin-labeled magnetic resonance imaging
    • D.C. Alsop, J.A. Detre, and M. Grossman Assessment of cerebral blood flow in Alzheimer's disease by spin-labeled magnetic resonance imaging Ann Neurol 47 2000 93 100
    • (2000) Ann Neurol , vol.47 , pp. 93-100
    • Alsop, D.C.1    Detre, J.A.2    Grossman, M.3
  • 55
    • 84863934532 scopus 로고    scopus 로고
    • Quantitative assessment of cerebral hemodynamic parameters by QUASAR arterial spin labeling in Alzheimer's disease and cognitively normal elderly adults at 3-Tesla
    • H.K. Mak, Q. Chan, and Z. Zhang Quantitative assessment of cerebral hemodynamic parameters by QUASAR arterial spin labeling in Alzheimer's disease and cognitively normal elderly adults at 3-Tesla J Alzheimers Dis 31 2012 33 44
    • (2012) J Alzheimers Dis , vol.31 , pp. 33-44
    • Mak, H.K.1    Chan, Q.2    Zhang, Z.3
  • 56
    • 68549111123 scopus 로고    scopus 로고
    • Simultaneous measurement of arterial transit time, arterial blood volume, and cerebral blood flow using arterial spin-labeling in patients with Alzheimer disease
    • T. Yoshiura, A. Hiwatashi, and K. Yamashita Simultaneous measurement of arterial transit time, arterial blood volume, and cerebral blood flow using arterial spin-labeling in patients with Alzheimer disease AJNR Am J Neuroradiol 30 2009 1388 1393
    • (2009) AJNR Am J Neuroradiol , vol.30 , pp. 1388-1393
    • Yoshiura, T.1    Hiwatashi, A.2    Yamashita, K.3
  • 57
    • 82955243781 scopus 로고    scopus 로고
    • Voxel-level comparison of arterial spin-labeled perfusion MRI and FDG-PET in Alzheimer disease
    • Y. Chen, D.A. Wolk, and J.S. Reddin Voxel-level comparison of arterial spin-labeled perfusion MRI and FDG-PET in Alzheimer disease Neurology 77 2011 1977 1985
    • (2011) Neurology , vol.77 , pp. 1977-1985
    • Chen, Y.1    Wolk, D.A.2    Reddin, J.S.3
  • 58
    • 84856003965 scopus 로고    scopus 로고
    • Direct comparison of fluorodeoxyglucose positron emission tomography and arterial spin labeling magnetic resonance imaging in Alzheimer's disease
    • E.S. Musiek, Y. Chen, and M. Korczykowski Direct comparison of fluorodeoxyglucose positron emission tomography and arterial spin labeling magnetic resonance imaging in Alzheimer's disease Alzheimers Dement 8 2012 51 59
    • (2012) Alzheimers Dement , vol.8 , pp. 51-59
    • Musiek, E.S.1    Chen, Y.2    Korczykowski, M.3
  • 59
    • 77949708300 scopus 로고    scopus 로고
    • Reliability and precision of pseudo-continuous arterial spin labeling perfusion MRI on 3.0 T and comparison with 15O-water PET in elderly subjects at risk for Alzheimer's disease
    • G. Xu, H.A. Rowley, and G. Wu Reliability and precision of pseudo-continuous arterial spin labeling perfusion MRI on 3.0 T and comparison with 15O-water PET in elderly subjects at risk for Alzheimer's disease NMR Biomed 23 2010 286 293
    • (2010) NMR Biomed , vol.23 , pp. 286-293
    • Xu, G.1    Rowley, H.A.2    Wu, G.3
  • 60
    • 7044263028 scopus 로고    scopus 로고
    • Renal disease: Value of functional magnetic resonance imaging with flow and perfusion measurements
    • H.J. Michaely, S.O. Schoenberg, and C. Ittrich Renal disease: value of functional magnetic resonance imaging with flow and perfusion measurements Invest Radiol 39 2004 698 705
    • (2004) Invest Radiol , vol.39 , pp. 698-705
    • Michaely, H.J.1    Schoenberg, S.O.2    Ittrich, C.3
  • 61
    • 84863393460 scopus 로고    scopus 로고
    • Repeatability of renal arterial spin labelling MRI in healthy subjects
    • M. Cutajar, D.L. Thomas, and T. Banks Repeatability of renal arterial spin labelling MRI in healthy subjects MAGMA 25 2012 145 153
    • (2012) MAGMA , vol.25 , pp. 145-153
    • Cutajar, M.1    Thomas, D.L.2    Banks, T.3
  • 62
    • 14844343251 scopus 로고    scopus 로고
    • Arterial spin labeling blood flow magnetic resonance imaging for the characterization of metastatic renal cell carcinoma
    • B.C. de, N.M. Rofsky, and G. Duhamel Arterial spin labeling blood flow magnetic resonance imaging for the characterization of metastatic renal cell carcinoma Acad Radiol 12 2005 347 357
    • (2005) Acad Radiol , vol.12 , pp. 347-357
    • De, B.C.1    Rofsky, N.M.2    Duhamel, G.3
  • 63
    • 53049106264 scopus 로고    scopus 로고
    • Magnetic resonance imaging-measured blood flow change after antiangiogenic therapy with PTK787/ZK 222584 correlates with clinical outcome in metastatic renal cell carcinoma
    • B.C. de, D.C. Alsop, and D. George Magnetic resonance imaging-measured blood flow change after antiangiogenic therapy with PTK787/ZK 222584 correlates with clinical outcome in metastatic renal cell carcinoma Clin Cancer Res 14 2008 5548 5554
    • (2008) Clin Cancer Res , vol.14 , pp. 5548-5554
    • De, B.C.1    Alsop, D.C.2    George, D.3
  • 64
    • 0023938605 scopus 로고
    • Regional muscle blood flow capacity and exercise hyperemia in high-intensity trained rats
    • M.H. Laughlin, R.J. Korthuis, and W.L. Sexton Regional muscle blood flow capacity and exercise hyperemia in high-intensity trained rats J Appl Phys 64 1988 2420 2427
    • (1988) J Appl Phys , vol.64 , pp. 2420-2427
    • Laughlin, M.H.1    Korthuis, R.J.2    Sexton, W.L.3
  • 65
    • 30344436687 scopus 로고    scopus 로고
    • Fast perfusion measurements in rat skeletal muscle at rest and during exercise with single-voxel FAIR (flow-sensitive alternating inversion recovery)
    • R. Pohmann, B. Kunnecke, and J. Fingerle Fast perfusion measurements in rat skeletal muscle at rest and during exercise with single-voxel FAIR (flow-sensitive alternating inversion recovery) Magn Reson Med 55 2006 108 115
    • (2006) Magn Reson Med , vol.55 , pp. 108-115
    • Pohmann, R.1    Kunnecke, B.2    Fingerle, J.3
  • 66
    • 0031764521 scopus 로고    scopus 로고
    • Simultaneous measurement of perfusion and oxygenation changes using a multiple gradient-echo sequence: Application to human muscle study
    • V. Lebon, P.G. Carlier, and C. Brillault-Salvat Simultaneous measurement of perfusion and oxygenation changes using a multiple gradient-echo sequence: application to human muscle study Magn Reson Imaging 16 1998 721 729
    • (1998) Magn Reson Imaging , vol.16 , pp. 721-729
    • Lebon, V.1    Carlier, P.G.2    Brillault-Salvat, C.3
  • 67
    • 0032840942 scopus 로고    scopus 로고
    • Dynamic imaging of perfusion in human skeletal muscle during exercise with arterial spin labeling
    • L.R. Frank, E.C. Wong, and L.J. Haseler Dynamic imaging of perfusion in human skeletal muscle during exercise with arterial spin labeling Magn Reson Med 42 1999 258 267
    • (1999) Magn Reson Med , vol.42 , pp. 258-267
    • Frank, L.R.1    Wong, E.C.2    Haseler, L.J.3
  • 68
    • 49049120690 scopus 로고    scopus 로고
    • Transit delay and flow quantification in muscle with continuous arterial spin labeling perfusion-MRI
    • W.C. Wu, J. Wang, and J.A. Detre Transit delay and flow quantification in muscle with continuous arterial spin labeling perfusion-MRI J Magn Reson Imaging 28 2008 445 452
    • (2008) J Magn Reson Imaging , vol.28 , pp. 445-452
    • Wu, W.C.1    Wang, J.2    Detre, J.A.3
  • 69
    • 66949151329 scopus 로고    scopus 로고
    • Skeletal muscle microvascular flow in progressive peripheral artery disease: Assessment with continuous arterial spin-labeling perfusion magnetic resonance imaging
    • W.C. Wu, E. Mohler 3rd, and S.J. Ratcliffe Skeletal muscle microvascular flow in progressive peripheral artery disease: assessment with continuous arterial spin-labeling perfusion magnetic resonance imaging J Am Coll Cardiol 53 2009 2372 2377
    • (2009) J Am Coll Cardiol , vol.53 , pp. 2372-2377
    • Wu, W.C.1    Mohler III, E.2    Ratcliffe, S.J.3
  • 70
    • 11144282635 scopus 로고    scopus 로고
    • Defective myocardial blood flow and altered function of the left ventricle in type 2 diabetic rats: A noninvasive in vivo study using perfusion and cine magnetic resonance imaging
    • I. Iltis, F. Kober, and M. Desrois Defective myocardial blood flow and altered function of the left ventricle in type 2 diabetic rats: a noninvasive in vivo study using perfusion and cine magnetic resonance imaging Invest Radiol 40 2005 19 26
    • (2005) Invest Radiol , vol.40 , pp. 19-26
    • Iltis, I.1    Kober, F.2    Desrois, M.3
  • 71
    • 19344373840 scopus 로고    scopus 로고
    • Impaired resting perfusion in viable myocardium distal to chronic coronary stenosis in rats
    • C. Waller, T. Engelhorn, and K.H. Hiller Impaired resting perfusion in viable myocardium distal to chronic coronary stenosis in rats Am J Physiol Heart Circ Physiol 288 2005 H2588 H2593
    • (2005) Am J Physiol Heart Circ Physiol , vol.288
    • Waller, C.1    Engelhorn, T.2    Hiller, K.H.3
  • 72
    • 65249115842 scopus 로고    scopus 로고
    • Arterial spin-labeled MR perfusion imaging: Clinical applications
    • J.M. Pollock, H. Tan, and R.A. Kraft Arterial spin-labeled MR perfusion imaging: clinical applications Magn Reson Imaging Clin N Am 17 2009 315 338
    • (2009) Magn Reson Imaging Clin N Am , vol.17 , pp. 315-338
    • Pollock, J.M.1    Tan, H.2    Kraft, R.A.3
  • 73
    • 0141841839 scopus 로고    scopus 로고
    • Pediatric perfusion imaging using pulsed arterial spin labeling
    • J. Wang, D.J. Licht, and G.-H. Jahng Pediatric perfusion imaging using pulsed arterial spin labeling J Magn Reson Imaging 18 2003 404 413
    • (2003) J Magn Reson Imaging , vol.18 , pp. 404-413
    • Wang, J.1    Licht, D.J.2    Jahng, G.-H.3
  • 74
    • 0015886330 scopus 로고
    • Quantitative growth and development of human brain
    • J. Dobbing, and J. Sands Quantitative growth and development of human brain Arch Dis Child 48 1973 757 767
    • (1973) Arch Dis Child , vol.48 , pp. 757-767
    • Dobbing, J.1    Sands, J.2
  • 76
    • 0021991039 scopus 로고
    • What is the correct value for the brain-blood partition coefficient for water?
    • P. Herscovitch, and M.E. Raichle What is the correct value for the brain-blood partition coefficient for water? J Cereb Blood Flow Metab 5 1985 65 69
    • (1985) J Cereb Blood Flow Metab , vol.5 , pp. 65-69
    • Herscovitch, P.1    Raichle, M.E.2
  • 77
    • 0035719913 scopus 로고    scopus 로고
    • Developmental aspects of pediatric fMRI: Considerations for image acquisition, analysis, and interpretation
    • W.D. Gaillard, C.B. Grandin, and B. Xu Developmental aspects of pediatric fMRI: considerations for image acquisition, analysis, and interpretation Neuroimage 13 2001 239 249
    • (2001) Neuroimage , vol.13 , pp. 239-249
    • Gaillard, W.D.1    Grandin, C.B.2    Xu, B.3
  • 78
    • 37849032997 scopus 로고    scopus 로고
    • Assessment of functional development in normal infant brain using arterial spin labeled perfusion MRI
    • Z. Wang, M. Fernandez-Seara, and D.C. Alsop Assessment of functional development in normal infant brain using arterial spin labeled perfusion MRI Neuroimage 39 2008 973 978
    • (2008) Neuroimage , vol.39 , pp. 973-978
    • Wang, Z.1    Fernandez-Seara, M.2    Alsop, D.C.3
  • 79
    • 60549084357 scopus 로고    scopus 로고
    • Arterial spin labeling perfusion MRI in pediatric arterial ischemic stroke: Initial experiences
    • J. Chen, D.J. Licht, and S.E. Smith Arterial spin labeling perfusion MRI in pediatric arterial ischemic stroke: initial experiences J Magn Reson Imaging 29 2009 282 290
    • (2009) J Magn Reson Imaging , vol.29 , pp. 282-290
    • Chen, J.1    Licht, D.J.2    Smith, S.E.3
  • 80
    • 84858740039 scopus 로고    scopus 로고
    • Arterial spin labeling measurement of cerebral perfusion in children with sickle cell disease
    • S. Gevers, A.J. Nederveen, and K. Fijnvandraat Arterial spin labeling measurement of cerebral perfusion in children with sickle cell disease J Magn Reson Imaging 35 2012 779 787
    • (2012) J Magn Reson Imaging , vol.35 , pp. 779-787
    • Gevers, S.1    Nederveen, A.J.2    Fijnvandraat, K.3
  • 81
    • 0037406939 scopus 로고    scopus 로고
    • Sickle cell disease: Continuous arterial spin-labeling perfusion MR imaging in children
    • K.K. Oguz, X. Golay, and F.B. Pizzini Sickle cell disease: continuous arterial spin-labeling perfusion MR imaging in children Radiology 227 2003 567 574
    • (2003) Radiology , vol.227 , pp. 567-574
    • Oguz, K.K.1    Golay, X.2    Pizzini, F.B.3
  • 82
    • 33745622409 scopus 로고    scopus 로고
    • Inverse correlation between cerebral blood flow measured by continuous arterial spin-labeling (CASL) MRI and neurocognitive function in children with sickle cell anemia (SCA)
    • J.J. Strouse, C.S. Cox, and E.R. Melhem Inverse correlation between cerebral blood flow measured by continuous arterial spin-labeling (CASL) MRI and neurocognitive function in children with sickle cell anemia (SCA) Blood 108 2006 379 381
    • (2006) Blood , vol.108 , pp. 379-381
    • Strouse, J.J.1    Cox, C.S.2    Melhem, E.R.3
  • 83
    • 58149385349 scopus 로고    scopus 로고
    • Arterial spin-labeled perfusion combined with segmentation techniques to evaluate cerebral blood flow in white and gray matter of children with sickle cell anemia
    • K.J. Helton, A. Paydar, and J. Glass Arterial spin-labeled perfusion combined with segmentation techniques to evaluate cerebral blood flow in white and gray matter of children with sickle cell anemia Pediatr Blood Cancer 52 2009 85 91
    • (2009) Pediatr Blood Cancer , vol.52 , pp. 85-91
    • Helton, K.J.1    Paydar, A.2    Glass, J.3
  • 84
    • 84862702247 scopus 로고    scopus 로고
    • Non-invasive pulmonary perfusion assessment in young patients with cystic fibrosis using an arterial spin labeling MR technique at 1.5 T
    • C. Schraml, N.F. Schwenzer, and P. Martirosian Non-invasive pulmonary perfusion assessment in young patients with cystic fibrosis using an arterial spin labeling MR technique at 1.5 T MAGMA 25 2012 155 162
    • (2012) MAGMA , vol.25 , pp. 155-162
    • Schraml, C.1    Schwenzer, N.F.2    Martirosian, P.3
  • 85
    • 33747616876 scopus 로고    scopus 로고
    • Noninvasive measurements of regional cerebral perfusion in preterm and term neonates by magnetic resonance arterial spin labeling
    • M.J. Miranda, K. Olofsson, and K. Sidaros Noninvasive measurements of regional cerebral perfusion in preterm and term neonates by magnetic resonance arterial spin labeling Pediatr Res 60 2006 359 363
    • (2006) Pediatr Res , vol.60 , pp. 359-363
    • Miranda, M.J.1    Olofsson, K.2    Sidaros, K.3
  • 86
    • 78851469408 scopus 로고    scopus 로고
    • A method for rapid in vivo measurement of blood T1
    • M. Varela, J.V. Hajnal, and E.T. Petersen A method for rapid in vivo measurement of blood T1 NMR Biomed 24 2011 80 88
    • (2011) NMR Biomed , vol.24 , pp. 80-88
    • Varela, M.1    Hajnal, J.V.2    Petersen, E.T.3
  • 87
    • 33645062189 scopus 로고    scopus 로고
    • Why perfusion in neonates with congenital heart defects is negative-technical issues related to pulsed arterial spin labeling
    • J. Wang, D.J. Licht, and D.W. Silvestre Why perfusion in neonates with congenital heart defects is negative-technical issues related to pulsed arterial spin labeling Magn Reson Imaging 24 2006 249 254
    • (2006) Magn Reson Imaging , vol.24 , pp. 249-254
    • Wang, J.1    Licht, D.J.2    Silvestre, D.W.3
  • 88
    • 9644270151 scopus 로고    scopus 로고
    • Preoperative cerebral blood flow is diminished in neonates with severe congenital heart defects
    • D.J. Licht, J. Wang, and D.W. Silvestre Preoperative cerebral blood flow is diminished in neonates with severe congenital heart defects J Thorac Cardiovasc Surg 128 2004 841 849
    • (2004) J Thorac Cardiovasc Surg , vol.128 , pp. 841-849
    • Licht, D.J.1    Wang, J.2    Silvestre, D.W.3
  • 89
    • 84866149129 scopus 로고    scopus 로고
    • A quantitative method for correlating observations of decreased apparent diffusion coefficient with elevated cerebral blood perfusion in newborns presenting cerebral ischemic insults
    • R. Pienaar, M.J. Paldino, and N. Madan A quantitative method for correlating observations of decreased apparent diffusion coefficient with elevated cerebral blood perfusion in newborns presenting cerebral ischemic insults Neuroimage 63 3 2012 1510 1518
    • (2012) Neuroimage , vol.63 , Issue.3 , pp. 1510-1518
    • Pienaar, R.1    Paldino, M.J.2    Madan, N.3
  • 90
    • 84861684873 scopus 로고    scopus 로고
    • New insights in perinatal arterial ischemic stroke by assessing brain perfusion
    • P. Wintermark, and S. Warfield New insights in perinatal arterial ischemic stroke by assessing brain perfusion Transl Stroke Res 2 2012 255 262
    • (2012) Transl Stroke Res , vol.2 , pp. 255-262
    • Wintermark, P.1    Warfield, S.2
  • 91
    • 84455191520 scopus 로고    scopus 로고
    • Brain perfusion in asphyxiated newborns treated with therapeutic hypothermia
    • P. Wintermark, A. Hansen, and M.C. Gregas Brain perfusion in asphyxiated newborns treated with therapeutic hypothermia AJNR Am J Neuroradiol 32 2011 2023 2029
    • (2011) AJNR Am J Neuroradiol , vol.32 , pp. 2023-2029
    • Wintermark, P.1    Hansen, A.2    Gregas, M.C.3
  • 92
    • 0031966050 scopus 로고    scopus 로고
    • Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II)
    • E.C. Wong, R.B. Buxton, and L.R. Frank Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II) Magn Reson Med 39 1998 702 708
    • (1998) Magn Reson Med , vol.39 , pp. 702-708
    • Wong, E.C.1    Buxton, R.B.2    Frank, L.R.3
  • 93
    • 0032997648 scopus 로고    scopus 로고
    • QUIPSS II with thin-slice TI1 periodic saturation: A method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labeling
    • W.M. Luh, E.C. Wong, and P.A. Bandettini QUIPSS II with thin-slice TI1 periodic saturation: a method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labeling Magn Reson Med 41 1999 1246 1254
    • (1999) Magn Reson Med , vol.41 , pp. 1246-1254
    • Luh, W.M.1    Wong, E.C.2    Bandettini, P.A.3
  • 94
    • 0031022848 scopus 로고    scopus 로고
    • Correction for vascular artifacts in cerebral blood flow values measured by using arterial spin tagging techniques
    • F.Q. Ye, V.S. Mattay, and P. Jezzard Correction for vascular artifacts in cerebral blood flow values measured by using arterial spin tagging techniques Magn Reson Med 37 1997 226 235
    • (1997) Magn Reson Med , vol.37 , pp. 226-235
    • Ye, F.Q.1    Mattay, V.S.2    Jezzard, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.