-
1
-
-
20544461913
-
Multislice spiral computed tomographic angiography of coronary arteries in patients with suspected coronary artery disease: An effective filter before catheter angiography?
-
15976796 10.1016/j.ahj.2005.02.048
-
Haberl R, Tittus J, Böhme E, Czernik A, Richartz BM, Buck J, Steinbigler P (2005) Multislice spiral computed tomographic angiography of coronary arteries in patients with suspected coronary artery disease: an effective filter before catheter angiography? Am Heart J 149:1112-1119
-
(2005)
Am Heart J
, vol.149
, pp. 1112-1119
-
-
Haberl, R.1
Tittus, J.2
Böhme, E.3
Czernik, A.4
Richartz, B.M.5
Buck, J.6
Steinbigler, P.7
-
2
-
-
59649127716
-
Estimated radiation dose associated with cardiac CT angiography
-
19190314 10.1001/jama.2009.54 1:CAS:528:DC%2BD1MXhtlyksbk%3D
-
Hausleiter J, Meyer T, Hermann F, Hadamitzky M, Krebs M, Gerber TC, McCollough C, Martinoff S, Kastrati A, Schömig A, Achenbach S (2009) Estimated radiation dose associated with cardiac CT angiography. JAMA 301:500-507
-
(2009)
JAMA
, vol.301
, pp. 500-507
-
-
Hausleiter, J.1
Meyer, T.2
Hermann, F.3
Hadamitzky, M.4
Krebs, M.5
Gerber, T.C.6
McCollough, C.7
Martinoff, S.8
Kastrati, A.9
Schömig, A.10
Achenbach, S.11
-
3
-
-
77956825812
-
Adaptive statistical iterative reconstruction: Assessment of image noise and image quality in coronary CT angiography
-
20729442 10.2214/AJR.10.4285
-
Leipsic J, Labounty TM, Heilbron B, Min JK, Mancini GB, Lin FY, Taylor C, Dunning A, Earls JP (2010) Adaptive statistical iterative reconstruction: assessment of image noise and image quality in coronary CT angiography. AJR Am J Roentgenol 195:649-654
-
(2010)
AJR Am J Roentgenol
, vol.195
, pp. 649-654
-
-
Leipsic, J.1
Labounty, T.M.2
Heilbron, B.3
Min, J.K.4
Mancini, G.B.5
Lin, F.Y.6
Taylor, C.7
Dunning, A.8
Earls, J.P.9
-
4
-
-
80054984676
-
Iterative reconstruction in image space (IRIS) in cardiac computed tomography: Initial experience
-
21120612 10.1007/s10554-010-9756-3
-
Bittencourt MS, Schmidt B, Seltmann M, Muschiol G, Ropers D, Daniel WG, Achenbach S (2011) Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience. Int J Cardiovasc Imaging 27:1081-1087
-
(2011)
Int J Cardiovasc Imaging
, vol.27
, pp. 1081-1087
-
-
Bittencourt, M.S.1
Schmidt, B.2
Seltmann, M.3
Muschiol, G.4
Ropers, D.5
Daniel, W.G.6
Achenbach, S.7
-
5
-
-
84870402674
-
Iterative reconstruction of dual-source coronary CT angiography: Assessment of image quality and radiation dose
-
(Epub ahead of print)
-
Park EA, Lee W, Kim KW, Kim KG, Thomas A, Chung JW, Park JH (2011) Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose. Int J Cardiovasc Imaging (Epub ahead of print)
-
(2011)
Int J Cardiovasc Imaging
-
-
Park, E.A.1
Lee, W.2
Kim, K.W.3
Kim, K.G.4
Thomas, A.5
Chung, J.W.6
Park, J.H.7
-
6
-
-
69949096664
-
Iterative reconstruction technique for reducing body radiation dose at CT: Feasibility study
-
19696291 10.2214/AJR.09.2397
-
Hara AK, Paden RG, Silva AC, Kujak JL, Lawder HJ, Pavlicek W (2009) Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study. AJR Am J Roentgenol 193:764-771
-
(2009)
AJR Am J Roentgenol
, vol.193
, pp. 764-771
-
-
Hara, A.K.1
Paden, R.G.2
Silva, A.C.3
Kujak, J.L.4
Lawder, H.J.5
Pavlicek, W.6
-
7
-
-
70349571729
-
Radiation dose modulation techniques in the multidetector CT era: From basics to practice
-
18794318 10.1148/rg.285075075
-
Lee CH, Goo JM, Ye HJ, Ye SJ, Park CM, Chun EJ, Im JG (2008) Radiation dose modulation techniques in the multidetector CT era: from basics to practice. Radiographics 28:1451-1459
-
(2008)
Radiographics
, vol.28
, pp. 1451-1459
-
-
Lee, C.H.1
Goo, J.M.2
Ye, H.J.3
Ye, S.J.4
Park, C.M.5
Chun, E.J.6
Im, J.G.7
-
8
-
-
39849088121
-
Effects of nitroglycerin on the diagnostic accuracy of electrocardiogram-gated coronary computed tomography angiography
-
18303294 10.1097/rct.0b013e318059befa
-
Chun EJ, Lee W, Choi YH, Koo BK, Choi SI, Jae HJ, Kim HC, So YH, Chung JW, Park JH (2008) Effects of nitroglycerin on the diagnostic accuracy of electrocardiogram-gated coronary computed tomography angiography. J Comput Assist Tomogr 32:86-92
-
(2008)
J Comput Assist Tomogr
, vol.32
, pp. 86-92
-
-
Chun, E.J.1
Lee, W.2
Choi, Y.H.3
Koo, B.K.4
Choi, S.I.5
Jae, H.J.6
Kim, H.C.7
So, Y.H.8
Chung, J.W.9
Park, J.H.10
-
9
-
-
84855310125
-
CT radiation dose optimization and estimation: An update for radiologists
-
22247630 10.3348/kjr.2012.13.1.1
-
Goo HW (2012) CT radiation dose optimization and estimation: an update for radiologists. Korean J Radiol 13:1-11
-
(2012)
Korean J Radiol
, vol.13
, pp. 1-11
-
-
Goo, H.W.1
-
10
-
-
79751531405
-
Computed tomography-old ideas and new technology
-
21249371 10.1007/s00330-011-2056-z
-
Fleischmann D, Boas FE (2011) Computed tomography-old ideas and new technology. Eur Radiol 21:510-517
-
(2011)
Eur Radiol
, vol.21
, pp. 510-517
-
-
Fleischmann, D.1
Boas, F.E.2
-
11
-
-
77954708865
-
Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: A pilot study
-
20566805 10.2214/AJR.09.3855
-
Flicek KT, Hara AK, Silva AC, Wu Q, Peter MB, Johnson CD (2010) Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: a pilot study. AJR Am J Roentgenol 195:126-131
-
(2010)
AJR Am J Roentgenol
, vol.195
, pp. 126-131
-
-
Flicek, K.T.1
Hara, A.K.2
Silva, A.C.3
Wu, Q.4
Peter, M.B.5
Johnson, C.D.6
-
12
-
-
0028873150
-
Clinical evaluation of pulmonary nodules with single-exposure dual-energy subtraction chest radiography with an iterative noise-reduction algorithm
-
7824718 1:STN:280:DyaK2M7isFaisQ%3D%3D
-
Kido S, Ikezoe J, Naito H, Arisawa J, Tamura S, Kozuka T, Ito W, Shimura K, Kato H (1995) Clinical evaluation of pulmonary nodules with single-exposure dual-energy subtraction chest radiography with an iterative noise-reduction algorithm. Radiology 194:407-412
-
(1995)
Radiology
, vol.194
, pp. 407-412
-
-
Kido, S.1
Ikezoe, J.2
Naito, H.3
Arisawa, J.4
Tamura, S.5
Kozuka, T.6
Ito, W.7
Shimura, K.8
Kato, H.9
-
13
-
-
78649700320
-
A prospective evaluation of dose reduction and image quality in chest CT using adaptive statistical iterative reconstruction
-
20966312 10.2214/AJR.09.4050
-
Leipsic J, Nguyen G, Brown J, Sin D, Mayo JR (2010) A prospective evaluation of dose reduction and image quality in chest CT using adaptive statistical iterative reconstruction. AJR Am J Roentgenol 195:1095-1099
-
(2010)
AJR Am J Roentgenol
, vol.195
, pp. 1095-1099
-
-
Leipsic, J.1
Nguyen, G.2
Brown, J.3
Sin, D.4
Mayo, J.R.5
-
14
-
-
75349092506
-
Low-tube-voltage, high-tube-current multidetector abdominal CT: Improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm-initial clinical experience
-
20032149 10.1148/radiol.09090094
-
Marin D, Nelson RC, Schindera ST, Richard S, Youngblood RS, Yoshizumi TT, Samei E (2010) Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm-initial clinical experience. Radiology 254:145-153
-
(2010)
Radiology
, vol.254
, pp. 145-153
-
-
Marin, D.1
Nelson, R.C.2
Schindera, S.T.3
Richard, S.4
Youngblood, R.S.5
Yoshizumi, T.T.6
Samei, E.7
-
15
-
-
79959960464
-
Dose reduction in abdominal computed tomography: Intraindividual comparison of image quality of full-dose standard and half-dose iterative reconstructions with dual-source computed tomography
-
21467948 10.1097/RLI.0b013e31821690a1
-
May MS, Wüst W, Brand M, Stahl C, Allmendinger T, Schmidt B, Uder M, Lell MM (2011) Dose reduction in abdominal computed tomography: intraindividual comparison of image quality of full-dose standard and half-dose iterative reconstructions with dual-source computed tomography. Invest Radiol 46:465-470
-
(2011)
Invest Radiol
, vol.46
, pp. 465-470
-
-
May, M.S.1
Wüst, W.2
Brand, M.3
Stahl, C.4
Allmendinger, T.5
Schmidt, B.6
Uder, M.7
Lell, M.M.8
-
16
-
-
79751526184
-
Chest computed tomography using iterative reconstruction versus filtered back projection (Part 2): Image quality of low-dose CT examinations in 80 patients
-
21080171 10.1007/s00330-010-1991-4
-
Pontana F, Duhamel A, Pagniez J, Flohr T, Faivre JB, Hachulla AL, Remy J, Remy-Jardin M (2011) Chest computed tomography using iterative reconstruction versus filtered back projection (Part 2): image quality of low-dose CT examinations in 80 patients. Eur Radiol 21:636-643
-
(2011)
Eur Radiol
, vol.21
, pp. 636-643
-
-
Pontana, F.1
Duhamel, A.2
Pagniez, J.3
Flohr, T.4
Faivre, J.B.5
Hachulla, A.L.6
Remy, J.7
Remy-Jardin, M.8
-
17
-
-
79751534189
-
Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): Evaluation of image noise reduction in 32 patients
-
21053003 10.1007/s00330-010-1990-5
-
Pontana F, Pagniez J, Flohr T, Faivre JB, Duhamel A, Remy J, Remy-Jardin M (2011) Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): evaluation of image noise reduction in 32 patients. Eur Radiol 21:627-635
-
(2011)
Eur Radiol
, vol.21
, pp. 627-635
-
-
Pontana, F.1
Pagniez, J.2
Flohr, T.3
Faivre, J.B.4
Duhamel, A.5
Remy, J.6
Remy-Jardin, M.7
-
18
-
-
77956841482
-
Abdominal CT: Comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients
-
20729451 10.2214/AJR.09.2989
-
Sagara Y, Hara AK, Pavlicek W, Silva AC, Paden RG, Wu Q (2010) Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients. AJR Am J Roentgenol 195:713-719
-
(2010)
AJR Am J Roentgenol
, vol.195
, pp. 713-719
-
-
Sagara, Y.1
Hara, A.K.2
Pavlicek, W.3
Silva, A.C.4
Paden, R.G.5
Wu, Q.6
-
19
-
-
79960687077
-
Iterative reconstruction algorithm for abdominal multidetector CT at different tube voltages: Assessment of diagnostic accuracy, image quality, and radiation dose in a phantom study
-
21493795 10.1148/radiol.11102217
-
Schindera ST, Diedrichsen L, Müller HC, Rusch O, Marin D, Schmidt B, Raupach R, Vock P, Szucs-Farkas Z (2011) Iterative reconstruction algorithm for abdominal multidetector CT at different tube voltages: assessment of diagnostic accuracy, image quality, and radiation dose in a phantom study. Radiology 260:454-462
-
(2011)
Radiology
, vol.260
, pp. 454-462
-
-
Schindera, S.T.1
Diedrichsen, L.2
Müller, H.C.3
Rusch, O.4
Marin, D.5
Schmidt, B.6
Raupach, R.7
Vock, P.8
Szucs-Farkas, Z.9
-
20
-
-
79955036642
-
Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: A pilot study
-
21386048 10.1148/radiol.11101450
-
Singh S, Kalra MK, Gilman MD, Hsieh J, Pien HH, Digumarthy SR, Shepard JA (2011) Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study. Radiology 259:565-573
-
(2011)
Radiology
, vol.259
, pp. 565-573
-
-
Singh, S.1
Kalra, M.K.2
Gilman, M.D.3
Hsieh, J.4
Pien, H.H.5
Digumarthy, S.R.6
Shepard, J.A.7
-
21
-
-
77958569748
-
Abdominal CT: Comparison of adaptive statistical iterative and filtered back projection reconstruction techniques
-
20829535 10.1148/radiol.10092212
-
Singh S, Kalra MK, Hsieh J, Licato PE, Do S, Pien HH, Blake MA (2010) Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction techniques. Radiology 257:373-383
-
(2010)
Radiology
, vol.257
, pp. 373-383
-
-
Singh, S.1
Kalra, M.K.2
Hsieh, J.3
Licato, P.E.4
Do, S.5
Pien, H.H.6
Blake, M.A.7
-
23
-
-
0025465145
-
Scale-space and edge detection using anisotropic diffusion
-
10.1109/34.56205
-
Perona P, Malik J (1990) Scale-space and edge detection using anisotropic diffusion. IEEE Trans Pattern Anal Mach Intell 12:629-639
-
(1990)
IEEE Trans Pattern Anal Mach Intell
, vol.12
, pp. 629-639
-
-
Perona, P.1
Malik, J.2
-
24
-
-
80054899972
-
Coronary CT angiography of patients with a normal body mass index using 80 versus 100 kVp: A prospective, multicenter, multivendor randomized trial
-
22021533 10.2214/AJR.11.6787
-
LaBounty TM, Leipsic J, Poulter R, Wood D, Johnson M, Srichai MB, Cury RC, Heilbron B, Hague C, Lin FY, Taylor C, Mayo JR, Thakur Y, Earls JP, Mancini GB, Dunning A, Gomez MJ, Min JK (2011) Coronary CT angiography of patients with a normal body mass index using 80 versus 100 kVp: a prospective, multicenter, multivendor randomized trial. AJR Am J Roentgenol 197:W860-W867
-
(2011)
AJR Am J Roentgenol
, vol.197
-
-
Labounty, T.M.1
Leipsic, J.2
Poulter, R.3
Wood, D.4
Johnson, M.5
Srichai, M.B.6
Cury, R.C.7
Heilbron, B.8
Hague, C.9
Lin, F.Y.10
Taylor, C.11
Mayo, J.R.12
Thakur, Y.13
Earls, J.P.14
Mancini, G.B.15
Dunning, A.16
Gomez, M.J.17
Min, J.K.18
-
25
-
-
66849138266
-
The image quality and radiation dose of 100-kVp versus 120-kVp ECG-gated 16-slice CT coronary angiography
-
19412511 10.3348/kjr.2009.10.3.235
-
Park EA, Lee W, Kang JH, Yin YH, Chung JW, Park JH (2009) The image quality and radiation dose of 100-kVp versus 120-kVp ECG-gated 16-slice CT coronary angiography. Korean J Radiol 10:235-243
-
(2009)
Korean J Radiol
, vol.10
, pp. 235-243
-
-
Park, E.A.1
Lee, W.2
Kang, J.H.3
Yin, Y.H.4
Chung, J.W.5
Park, J.H.6
-
26
-
-
79957814030
-
A prospective randomized controlled trial to assess the diagnostic performance of reduced tube voltage for coronary CT angiography
-
21427328 10.2214/AJR.10.5786
-
Leipsic J, LaBounty TM, Mancini GB, Heilbron B, Taylor C, Johnson MA, Hague C, Earls JP, Ajlan A, Min JK (2011) A prospective randomized controlled trial to assess the diagnostic performance of reduced tube voltage for coronary CT angiography. AJR Am J Roentgenol 196:801-806
-
(2011)
AJR Am J Roentgenol
, vol.196
, pp. 801-806
-
-
Leipsic, J.1
Labounty, T.M.2
Mancini, G.B.3
Heilbron, B.4
Taylor, C.5
Johnson, M.A.6
Hague, C.7
Earls, J.P.8
Ajlan, A.9
Min, J.K.10
-
27
-
-
49049120370
-
Prospective versus retrospective ECG-gated 64-detector coronary CT angiography: Assessment of image quality, stenosis, and radiation dose
-
18574140 10.1148/radiol.2482071804
-
Hirai N, Horiguchi J, Fujioka C, Kiguchi M, Yamamoto H, Matsuura N, Kitagawa T, Teragawa H, Kohno N, Ito K (2008) Prospective versus retrospective ECG-gated 64-detector coronary CT angiography: assessment of image quality, stenosis, and radiation dose. Radiology 248:424-430
-
(2008)
Radiology
, vol.248
, pp. 424-430
-
-
Hirai, N.1
Horiguchi, J.2
Fujioka, C.3
Kiguchi, M.4
Yamamoto, H.5
Matsuura, N.6
Kitagawa, T.7
Teragawa, H.8
Kohno, N.9
Ito, K.10
-
28
-
-
0036834823
-
Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: Influence of physiological and technical prerequisite on image quality
-
12386756
-
Herzog C, Abolmaali N, Balzer JO, Baunach S, Ackermann H, Dogan S, Britten MB, Vogl TJ (2002) Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality. Eur Radiol 12:2670-2678
-
(2002)
Eur Radiol
, vol.12
, pp. 2670-2678
-
-
Herzog, C.1
Abolmaali, N.2
Balzer, J.O.3
Baunach, S.4
Ackermann, H.5
Dogan, S.6
Britten, M.B.7
Vogl, T.J.8
-
29
-
-
50249178242
-
Low-dose CT coronary angiography in the step-and-shoot mode: Diagnostic performance
-
18519548 10.1136/hrt.2008.149971 1:STN:280:DC%2BD1crhvVersA%3D%3D
-
Scheffel H, Alkadhi H, Leschka S, Plass A, Desbiolles L, Guber I, Krauss T, Gruenenfelder J, Genoni M, Luescher TF, Marincek B, Stolzmann P (2008) Low-dose CT coronary angiography in the step-and-shoot mode: diagnostic performance. Heart 94:1132-1137 Technology
-
(2008)
Heart
, vol.94
, pp. 1132-1137
-
-
Scheffel, H.1
Alkadhi, H.2
Leschka, S.3
Plass, A.4
Desbiolles, L.5
Guber, I.6
Krauss, T.7
Gruenenfelder, J.8
Genoni, M.9
Luescher, T.F.10
Marincek, B.11
Stolzmann, P.12
|