Volumn 24, Issue 4, 2013, Pages 642-645

Feature based retention time alignment for improved HDX MS analysis

Author keywords

Chromatographic alignment; Fitting; Hydrogen deuterium exchange; Isotopic cluster; Mass spectrometry; Retention time correction

Indexed keywords

DEUTERIUM INCORPORATIONS; DISTANCE MINIMIZATIONS; FITTING; HYDROGEN-DEUTERIUM EXCHANGE; ISOTOPIC CLUSTER; PAIR-WISE COMPARISON; RETENTION TIME; RETENTION TIME ALIGNMENTS;

EID: 84879536137     PISSN: 10440305     EISSN: 18791123     Source Type: Journal    
DOI: 10.1007/s13361-012-0566-9     Document Type: Article
Times cited : (10)

References (11)
  • 1
    • 79251597334 scopus 로고    scopus 로고
    • Peak alignment using wavelet pattern matching and differential evolution
    • 10.1016/j.talanta.2010.08.008 1:CAS:528:DC%2BC3MXktV2ltQ%3D%3D
    • Zhang, Z.M.; Chen, S.; Liang, Y.Z.: Peak alignment using wavelet pattern matching and differential evolution. Talanta 83, 1108-1117 (2011)
    • (2011) Talanta , vol.83 , pp. 1108-1117
    • Zhang, Z.M.1    Chen, S.2    Liang, Y.Z.3
  • 2
    • 4444351752 scopus 로고    scopus 로고
    • Correlation optimized warping and dynamic time warping as preprocessing methods for chromatographic data
    • 10.1002/cem.859 1:CAS:528:DC%2BD2cXnvVWgtbg%3D
    • Tomasi, G.; van der Berg, F.; Andersson, C.: Correlation optimized warping and dynamic time warping as preprocessing methods for chromatographic data. J. Chemometr. 18, 231-241 (2004)
    • (2004) J. Chemometr. , vol.18 , pp. 231-241
    • Tomasi, G.1    Van Der Berg, F.2    Andersson, C.3
  • 4
    • 68549083763 scopus 로고    scopus 로고
    • ChromA: Signal-based retention time alignment for chromatography-mass spectrometry data
    • 10.1093/bioinformatics/btp343 1:CAS:528:DC%2BD1MXpslersbk%3D
    • Hoffmann, N.; Stoye, J.: ChromA: Signal-based retention time alignment for chromatography-mass spectrometry data. Bioinformatics 25, 2080-2081 (2009)
    • (2009) Bioinformatics , vol.25 , pp. 2080-2081
    • Hoffmann, N.1    Stoye, J.2
  • 5
    • 65249132985 scopus 로고    scopus 로고
    • MetAlign: Interface-driven, versatile metabolomics tool for hyphenated full-scan mass spectrometry data preprocessing
    • 10.1021/ac900036d 1:CAS:528:DC%2BD1MXjsVKktbo%3D
    • Lommen, A.: MetAlign: Interface-driven, versatile metabolomics tool for hyphenated full-scan mass spectrometry data preprocessing. Anal. Chem. 81, 3079-3086 (2009)
    • (2009) Anal. Chem. , vol.81 , pp. 3079-3086
    • Lommen, A.1
  • 6
    • 77956520033 scopus 로고    scopus 로고
    • Chromaligner: A web server for chromatogram alignment
    • 10.1093/bioinformatics/btq337 1:CAS:528:DC%2BC3cXhtFGhu7vM
    • Wang, S.Y.; Ho, T.J.; Kuo, C.H.; Tseng, Y.J.: Chromaligner: A web server for chromatogram alignment. Bioinformatics 26, 2338-2339 (2010)
    • (2010) Bioinformatics , vol.26 , pp. 2338-2339
    • Wang, S.Y.1    Ho, T.J.2    Kuo, C.H.3    Tseng, Y.J.4
  • 7
    • 79951887389 scopus 로고    scopus 로고
    • Hydrogen exchange mass spectrometry for studying protein structure and dynamics
    • 10.1039/c0cs00113a 1:CAS:528:DC%2BC3MXit1Kitrk%3D
    • Konermann, L.; Pan, J.; Liu, Y.H.: Hydrogen exchange mass spectrometry for studying protein structure and dynamics. Chem. Soc. Rev. 40, 1224-1234 (2011)
    • (2011) Chem. Soc. Rev. , vol.40 , pp. 1224-1234
    • Konermann, L.1    Pan, J.2    Liu, Y.H.3
  • 8
    • 84879520833 scopus 로고    scopus 로고
    • Center, S.P.: Software:ReAdW Accessed September 3, 2012
    • Center, S.P.: Software:ReAdW. (2012); Available at: http://tools. proteomecenter.org/wiki/index.php?title=Software:ReAdW#Current-Version. Accessed September 3, 2012
    • (2012)
  • 10
    • 30044445240 scopus 로고    scopus 로고
    • Quantitating the statistical distribution of deuterium incorporation to extend the utility of H/D exchange MS data
    • 10.1021/ac050988l 1:CAS:528:DC%2BD2MXht1WisLzF
    • Chik, J.K.; Graaf, J.L.V.; Schriemer, D.C.: Quantitating the statistical distribution of deuterium incorporation to extend the utility of H/D exchange MS data. Anal. Chem. 78, 207-214 (2006)
    • (2006) Anal. Chem. , vol.78 , pp. 207-214
    • Chik, J.K.1    Graaf, J.L.V.2    Schriemer, D.C.3
  • 11
    • 33144462544 scopus 로고    scopus 로고
    • Probing protein ligand interactions by automated hydrogen/deuterium exchange mass spectrometry
    • 10.1021/ac051294f 1:CAS:528:DC%2BD28XjtFSqsw%3D%3D
    • Chalmers, M.J.; Busby, S.A.; Pascal, B.D.; He, Y.; Hendrickson, C.L.; Marshall, A.G.; Griffin, P.R.: Probing protein ligand interactions by automated hydrogen/deuterium exchange mass spectrometry. Anal. Chem. 78, 1005-1014 (2006)
    • (2006) Anal. Chem. , vol.78 , pp. 1005-1014
    • Chalmers, M.J.1    Busby, S.A.2    Pascal, B.D.3    He, Y.4    Hendrickson, C.L.5    Marshall, A.G.6    Griffin, P.R.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.