메뉴 건너뛰기




Volumn 31, Issue 6, 2013, Pages 942-945

Magnitude of D-dimer matters for diagnosing pulmonary embolus

Author keywords

[No Author keywords available]

Indexed keywords

CONTRAST MEDIUM; D DIMER;

EID: 84879073543     PISSN: 07356757     EISSN: 15328171     Source Type: Journal    
DOI: 10.1016/j.ajem.2013.03.009     Document Type: Article
Times cited : (11)

References (32)
  • 1
    • 0141796729 scopus 로고    scopus 로고
    • Evaluation of D-dimer in the diagnosis of suspected deep-vein thrombosis
    • P.S. Wells, D.R. Anderson, and M. Rodger Evaluation of D-dimer in the diagnosis of suspected deep-vein thrombosis N Engl J Med 349 2003 1227 1235
    • (2003) N Engl J Med , vol.349 , pp. 1227-1235
    • Wells, P.S.1    Anderson, D.R.2    Rodger, M.3
  • 2
    • 0023777954 scopus 로고
    • Diagnostic value of plasma D-dimer in suspected pulmonary embolism
    • H. Bounameaux, D. Slosman, and P.A. De Moerloose Diagnostic value of plasma D-dimer in suspected pulmonary embolism Lancet 332 8611 1988 628 629
    • (1988) Lancet , vol.332 , Issue.8611 , pp. 628-629
    • Bounameaux, H.1    Slosman, D.2    De Moerloose, P.A.3
  • 3
    • 0024598376 scopus 로고
    • Plasma D-dimer and pulmonary embolism
    • F. Bridey, C. Phlipotteau, and M. Dreyfus Plasma D-dimer and pulmonary embolism Lancet 333 8641 1989 791 792
    • (1989) Lancet , vol.333 , Issue.8641 , pp. 791-792
    • Bridey, F.1    Phlipotteau, C.2    Dreyfus, M.3
  • 4
    • 0026069416 scopus 로고
    • Measurement of D-dimer in plasma as diagnostic aid in suspected pulmonary embolism
    • H.P. Bounameaux, P. Cirafici, and P. De Moerloose Measurement of D-dimer in plasma as diagnostic aid in suspected pulmonary embolism Lancet 337 8735 1991 196 200
    • (1991) Lancet , vol.337 , Issue.8735 , pp. 196-200
    • Bounameaux, H.P.1    Cirafici, P.2    De Moerloose, P.3
  • 5
    • 0028896398 scopus 로고
    • Application of a novel and rapid whole blood assay for D-dimer in patients with clinically suspected pulmonary embolism
    • J.S. Ginsberg, P.S. Wells, and P.E. Brill-Edwards Application of a novel and rapid whole blood assay for D-dimer in patients with clinically suspected pulmonary embolism Thromb Haemost 73 1 1995 35
    • (1995) Thromb Haemost , vol.73 , Issue.1 , pp. 35
    • Ginsberg, J.S.1    Wells, P.S.2    Brill-Edwards, P.E.3
  • 6
    • 0029870420 scopus 로고    scopus 로고
    • Diagnosis of pulmonary embolism by a decision analysis-based strategy including clinical probability, D-dimer levels, and ultrasonography: A management study
    • A. Perrier, H. Bounameaux, and A. Morabia Diagnosis of pulmonary embolism by a decision analysis-based strategy including clinical probability, D-dimer levels, and ultrasonography: a management study Arch Intern Med 156 5 1996 531
    • (1996) Arch Intern Med , vol.156 , Issue.5 , pp. 531
    • Perrier, A.1    Bounameaux, H.2    Morabia, A.3
  • 7
    • 0030754108 scopus 로고    scopus 로고
    • D-dimer testing for suspected pulmonary embolism in outpatients
    • A. Perrier, S. Desmarais, and C. Goehring D-dimer testing for suspected pulmonary embolism in outpatients Am J Respir Crit Care Med 156 2 1997 492
    • (1997) Am J Respir Crit Care Med , vol.156 , Issue.2 , pp. 492
    • Perrier, A.1    Desmarais, S.2    Goehring, C.3
  • 8
    • 17444375639 scopus 로고    scopus 로고
    • Sensitivity and specificity of a rapid whole-blood assay for D-dimer in the diagnosis of pulmonary embolism
    • J.S. Ginsberg, P.S. Wells, and C. Kearon Sensitivity and specificity of a rapid whole-blood assay for D-dimer in the diagnosis of pulmonary embolism Ann Intern Med 129 12 1998 1006 1011
    • (1998) Ann Intern Med , vol.129 , Issue.12 , pp. 1006-1011
    • Ginsberg, J.S.1    Wells, P.S.2    Kearon, C.3
  • 9
    • 0034063321 scopus 로고    scopus 로고
    • Derivation of a simple clinical model to categorize patients probability of pulmonary embolism: Increasing the models utility with the SimpliRED D-dimer
    • P.S. Wells, D.R. Anderson, and M. Rodger Derivation of a simple clinical model to categorize patients probability of pulmonary embolism: increasing the models utility with the SimpliRED D-dimer Thromb Haemost 83 2000 416 420
    • (2000) Thromb Haemost , vol.83 , pp. 416-420
    • Wells, P.S.1    Anderson, D.R.2    Rodger, M.3
  • 10
    • 0035902631 scopus 로고    scopus 로고
    • Excluding pulmonary embolism at the bedside without diagnostic imaging: Management of patients with suspected pulmonary embolism presenting to the emergency department by using a simple clinical model and D-dimer
    • P.S. Wells, D.R. Anderson, and M. Rodger Excluding pulmonary embolism at the bedside without diagnostic imaging: management of patients with suspected pulmonary embolism presenting to the emergency department by using a simple clinical model and D-dimer Ann Intern Med 135 2 2001 98 107
    • (2001) Ann Intern Med , vol.135 , Issue.2 , pp. 98-107
    • Wells, P.S.1    Anderson, D.R.2    Rodger, M.3
  • 11
    • 0037158139 scopus 로고    scopus 로고
    • Use of a clinical decision rule in combination with D-dimer concentration in diagnostic workup of patients with suspected pulmonary embolism: A prospective management study
    • M.J. Kruip, M.J. Slob, and J.H. Schijen Use of a clinical decision rule in combination with D-dimer concentration in diagnostic workup of patients with suspected pulmonary embolism: a prospective management study Arch Intern Med 162 2002 1631 1635
    • (2002) Arch Intern Med , vol.162 , pp. 1631-1635
    • Kruip, M.J.1    Slob, M.J.2    Schijen, J.H.3
  • 12
    • 19944430823 scopus 로고    scopus 로고
    • Non-invasive diagnostic work-up of patients with clinically suspected pulmonary embolism; Results of a management study
    • M. Ten Wolde, P.J. Hagen, and M.R. Macgillavry Non-invasive diagnostic work-up of patients with clinically suspected pulmonary embolism; results of a management study J Thromb Haemost 2 2004 1110 1117
    • (2004) J Thromb Haemost , vol.2 , pp. 1110-1117
    • Ten Wolde, M.1    Hagen, P.J.2    Macgillavry, M.R.3
  • 13
    • 30444431617 scopus 로고    scopus 로고
    • Effectiveness of managing suspected pulmonary embolism using an algorithm combining clinical probability, D-dimer testing, and computed tomography
    • A. van Belle, H.R. Buller, and M.V. Huisman Effectiveness of managing suspected pulmonary embolism using an algorithm combining clinical probability, D-dimer testing, and computed tomography JAMA 295 2006 172 179
    • (2006) JAMA , vol.295 , pp. 172-179
    • Van Belle, A.1    Buller, H.R.2    Huisman, M.V.3
  • 14
    • 13244256881 scopus 로고    scopus 로고
    • Clinical criteria to prevent unnecessary diagnostic testing in emergency department patients with suspected pulmonary embolism
    • J.A. Kline, A.M. Mitchell, and C. Kabrhel Clinical criteria to prevent unnecessary diagnostic testing in emergency department patients with suspected pulmonary embolism J Thromb Haemost 2 8 2004 1247 1255
    • (2004) J Thromb Haemost , vol.2 , Issue.8 , pp. 1247-1255
    • Kline, J.A.1    Mitchell, A.M.2    Kabrhel, C.3
  • 15
    • 42149084404 scopus 로고    scopus 로고
    • Prospective multicenter evaluation of the pulmonary embolism rule-out criteria
    • J.A. Kline, D.M. Courtney, and C. Kabrhel Prospective multicenter evaluation of the pulmonary embolism rule-out criteria J Thromb Haemost 6 5 2008 772 780
    • (2008) J Thromb Haemost , vol.6 , Issue.5 , pp. 772-780
    • Kline, J.A.1    Courtney, D.M.2    Kabrhel, C.3
  • 16
    • 0035952293 scopus 로고    scopus 로고
    • The impact of the introduction of a rapid D-dimer assay on the diagnostic evaluation of suspected pulmonary embolism
    • N.M. Goldstein, M.H. Kollef, and S. Ward The impact of the introduction of a rapid D-dimer assay on the diagnostic evaluation of suspected pulmonary embolism Arch Intern Med 161 2001 567 571
    • (2001) Arch Intern Med , vol.161 , pp. 567-571
    • Goldstein, N.M.1    Kollef, M.H.2    Ward, S.3
  • 17
    • 33746404331 scopus 로고    scopus 로고
    • A highly sensitive ELISA D-dimer increases testing but not diagnosis of pulmonary embolism
    • C. Kabrhel, C. Matts, and M. McNamara A highly sensitive ELISA D-dimer increases testing but not diagnosis of pulmonary embolism Acad Emerg Med 13 5 2006 519 524
    • (2006) Acad Emerg Med , vol.13 , Issue.5 , pp. 519-524
    • Kabrhel, C.1    Matts, C.2    McNamara, M.3
  • 18
    • 79955765656 scopus 로고    scopus 로고
    • Time trends in pulmonary embolism in the United States: Evidence of overdiagnosis
    • R.S. Wiener, L.M. Schwartz, and S. Woloshin Time trends in pulmonary embolism in the United States: evidence of overdiagnosis Arch Intern Med 171 9 2011 831 837
    • (2011) Arch Intern Med , vol.171 , Issue.9 , pp. 831-837
    • Wiener, R.S.1    Schwartz, L.M.2    Woloshin, S.3
  • 19
    • 78649519120 scopus 로고    scopus 로고
    • Computed tomography use in the adult emergency department of an academic urban hospital from 2001 to 2007
    • J. Lee, J. Kirschner, S. Pawa, D. Wiener, D. Newman, and K. Shah Computed tomography use in the adult emergency department of an academic urban hospital from 2001 to 2007 Ann Emerg Med 56 6 2010 591 596
    • (2010) Ann Emerg Med , vol.56 , Issue.6 , pp. 591-596
    • Lee, J.1    Kirschner, J.2    Pawa, S.3    Wiener, D.4    Newman, D.5    Shah, K.6
  • 20
    • 20444486581 scopus 로고    scopus 로고
    • Quantitative high D-dimer value is predictive of pulmonary embolism occurrence independently of clinical score in a well-defined low risk factor population
    • J.L. Bosson, C. Barro, and B. Satger Quantitative high D-dimer value is predictive of pulmonary embolism occurrence independently of clinical score in a well-defined low risk factor population J Thromb Haemost 3 2005 93 99
    • (2005) J Thromb Haemost , vol.3 , pp. 93-99
    • Bosson, J.L.1    Barro, C.2    Satger, B.3
  • 21
    • 2442674382 scopus 로고    scopus 로고
    • Role of quantitative D-dimer assay in determining the need for CT angiography of acute pulmonary embolism
    • P.W. Abcarian, J.D. Sweet, and J.T. Watabe Role of quantitative D-dimer assay in determining the need for CT angiography of acute pulmonary embolism Am J Radiol 182 2004 1377 1381
    • (2004) Am J Radiol , vol.182 , pp. 1377-1381
    • Abcarian, P.W.1    Sweet, J.D.2    Watabe, J.T.3
  • 22
    • 46949085753 scopus 로고    scopus 로고
    • High D-dimer levels increase the likelihood of pulmonary embolism
    • L.W. Tick, M. Nijkeuter, and M.H.H. Kramer High D-dimer levels increase the likelihood of pulmonary embolism J Intern Med 264 2 2008 195 200
    • (2008) J Intern Med , vol.264 , Issue.2 , pp. 195-200
    • Tick, L.W.1    Nijkeuter, M.2    Kramer, M.H.H.3
  • 23
    • 65249117766 scopus 로고    scopus 로고
    • Potential impact of adjusting the threshold of the quantitative D-dimer based on pretest probability of acute pulmonary embolism
    • C. Kabrhel, D.M. Courtney, and C.A. Camargo Potential impact of adjusting the threshold of the quantitative D-dimer based on pretest probability of acute pulmonary embolism Acad Emerg Med 16 4 2009 325 332
    • (2009) Acad Emerg Med , vol.16 , Issue.4 , pp. 325-332
    • Kabrhel, C.1    Courtney, D.M.2    Camargo, C.A.3
  • 24
    • 45549093216 scopus 로고    scopus 로고
    • D-dimer for venous thromboembolism diagnosis: 20 years later
    • M. Righini, A. Perrier, and P. De Moerloose D-dimer for venous thromboembolism diagnosis: 20 years later J Thromb Haemost 6 7 2008 1059 1071
    • (2008) J Thromb Haemost , vol.6 , Issue.7 , pp. 1059-1071
    • Righini, M.1    Perrier, A.2    De Moerloose, P.3
  • 25
    • 84861529520 scopus 로고    scopus 로고
    • Right-sizing testing for pulmonary embolism: Recognizing the risks of detecting any clot
    • S.M. Green, and D.M. Yealy Right-sizing testing for pulmonary embolism: recognizing the risks of detecting any clot Ann Emerg Med 59 6 2012 524 526
    • (2012) Ann Emerg Med , vol.59 , Issue.6 , pp. 524-526
    • Green, S.M.1    Yealy, D.M.2
  • 26
    • 77950309096 scopus 로고    scopus 로고
    • Are clinical parameters and biomarkers predictive of severity of acute pulmonary emboli on CTPA?
    • V. Jeebun, S.J. Doe, and L. Singh Are clinical parameters and biomarkers predictive of severity of acute pulmonary emboli on CTPA? QJM 103 2 2010 91 97
    • (2010) QJM , vol.103 , Issue.2 , pp. 91-97
    • Jeebun, V.1    Doe, S.J.2    Singh, L.3
  • 27
    • 65349182938 scopus 로고    scopus 로고
    • The association of D-dimer levels with clinical outcomes in patients presenting with acute pulmonary embolism
    • J. Blamoun, M. Alfakir, and A.I. Sedfawy The association of D-dimer levels with clinical outcomes in patients presenting with acute pulmonary embolism Lab Hematol 15 1 2009 4 9
    • (2009) Lab Hematol , vol.15 , Issue.1 , pp. 4-9
    • Blamoun, J.1    Alfakir, M.2    Sedfawy, A.I.3
  • 28
    • 70449384607 scopus 로고    scopus 로고
    • D-dimer levels and 15-day outcome in acute pulmonary embolism. Findings from the RIETE Registry
    • J.L. Lobo, V. Zorilla, and F. Aizpuru D-dimer levels and 15-day outcome in acute pulmonary embolism. Findings from the RIETE Registry J Thromb Haemost 7 11 2009 1795 1801
    • (2009) J Thromb Haemost , vol.7 , Issue.11 , pp. 1795-1801
    • Lobo, J.L.1    Zorilla, V.2    Aizpuru, F.3
  • 29
    • 33744503127 scopus 로고    scopus 로고
    • Multidetector computed tomography for acute pulmonary embolism
    • P.D. Stein, S.E. Fowler, and L.R. Goodman Multidetector computed tomography for acute pulmonary embolism N Engl J Med 354 22 2006 2317 2327
    • (2006) N Engl J Med , vol.354 , Issue.22 , pp. 2317-2327
    • Stein, P.D.1    Fowler, S.E.2    Goodman, L.R.3
  • 30
    • 77951708399 scopus 로고    scopus 로고
    • Potential of an age adjusted D-dimer cut-off value to improve the exclusion of pulmonary embolism in older patients: A retrospective analysis of three large cohorts
    • R.A. Douma, G. le Gal, and M. Sohne Potential of an age adjusted D-dimer cut-off value to improve the exclusion of pulmonary embolism in older patients: a retrospective analysis of three large cohorts BMJ 340 3 2010 c1475
    • (2010) BMJ , vol.340 , Issue.3 , pp. 1475
    • Douma, R.A.1    Le Gal, G.2    Sohne, M.3
  • 31
    • 84859176927 scopus 로고    scopus 로고
    • D-dimer threshold increase with pretest probability unlikely for pulmonary embolism to decrease unnecessary computerized tomographic pulmonary angiography
    • J.A. Kline, M.M. Hogg, D.M. Courtney, C.D. Miller, A.E. Jones, and H.A. Smithline D-dimer threshold increase with pretest probability unlikely for pulmonary embolism to decrease unnecessary computerized tomographic pulmonary angiography J Thromb Haemost 10 2012 572 581
    • (2012) J Thromb Haemost , vol.10 , pp. 572-581
    • Kline, J.A.1    Hogg, M.M.2    Courtney, D.M.3    Miller, C.D.4    Jones, A.E.5    Smithline, H.A.6
  • 32
    • 77958552234 scopus 로고    scopus 로고
    • Subsegmental pulmonary embolism diagnosed by computed tomography: Incidence and clinical implications. A systematic review and meta-analysis of the management outcome studies subsegmental pulmonary embolism diagnosed by computed tomography
    • M. Carrier Subsegmental pulmonary embolism diagnosed by computed tomography: incidence and clinical implications. A systematic review and meta-analysis of the management outcome studies subsegmental pulmonary embolism diagnosed by computed tomography J Thromb Haemost 8 8 2010 1716 1722
    • (2010) J Thromb Haemost , vol.8 , Issue.8 , pp. 1716-1722
    • Carrier, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.