메뉴 건너뛰기




Volumn 223, Issue 1, 2013, Pages 61-68

Determination of three-dimensional muscle architectures: Validation of the DTI-based fiber tractography method by manual digitization

Author keywords

Diffusion tensor imaging; Fascicle orientation; m. soleus; MicroScribe; Muscle geometry; Pennation angle

Indexed keywords

ANIMAL TISSUE; ARTICLE; DIFFUSION TENSOR IMAGING; FEMALE; INTERMETHOD COMPARISON; MANUAL DIGITIZATION; MUSCLE CELL; MUSCULOSKELETAL SYSTEM PARAMETERS; NONHUMAN; PRIORITY JOURNAL; VALIDATION PROCESS;

EID: 84878958811     PISSN: 00218782     EISSN: 14697580     Source Type: Journal    
DOI: 10.1111/joa.12062     Document Type: Article
Times cited : (61)

References (58)
  • 1
    • 0038311010 scopus 로고    scopus 로고
    • Documentation and three-dimensional modelling of human soleus muscle architecture
    • Agur AM, Ng-Thow-Hing V, Ball KA, et al. (2003) Documentation and three-dimensional modelling of human soleus muscle architecture. Clin Anat 16, 285-293.
    • (2003) Clin Anat , vol.16 , pp. 285-293
    • Agur, A.M.1    Ng-Thow-Hing, V.2    Ball, K.A.3
  • 4
    • 84896691859 scopus 로고    scopus 로고
    • Three-dimensional surface geometries of the rabbit soleus muscle during contraction: input for biomechanical modelling and its validation
    • DOI 10.1007/s10237-013-0476-1.
    • Bol M, Leichsenring K, Weichert C, et al. (2013) Three-dimensional surface geometries of the rabbit soleus muscle during contraction: input for biomechanical modelling and its validation. Biomech Model Mechanobiol, DOI 10.1007/s10237-013-0476-1.
    • (2013) Biomech Model Mechanobiol
    • Bol, M.1    Leichsenring, K.2    Weichert, C.3
  • 5
    • 79958795109 scopus 로고    scopus 로고
    • A new approach for the validation of skeletal muscle modelling using MRI data
    • Böl M, Sturmat M, Weichert C, et al. (2011a) A new approach for the validation of skeletal muscle modelling using MRI data. Comput Mech 47, 591-601.
    • (2011) Comput Mech , vol.47 , pp. 591-601
    • Böl, M.1    Sturmat, M.2    Weichert, C.3
  • 6
    • 79960565244 scopus 로고    scopus 로고
    • A coupled electromechanical model for the excitation-dependent contraction of skeletal muscle
    • Böl M, Weikert R, Weichert C (2011b) A coupled electromechanical model for the excitation-dependent contraction of skeletal muscle. J Mech Behav Biomed Mater 4, 1299-1310.
    • (2011) J Mech Behav Biomed Mater , vol.4 , pp. 1299-1310
    • Böl, M.1    Weikert, R.2    Weichert, C.3
  • 7
    • 0036299019 scopus 로고    scopus 로고
    • Validation of diffusion tensor MRI-based muscle fiber tracking
    • Damon BM, Ding Z, Anderson AW, et al. (2002) Validation of diffusion tensor MRI-based muscle fiber tracking. Magn Reson Med 48, 97-104.
    • (2002) Magn Reson Med , vol.48 , pp. 97-104
    • Damon, B.M.1    Ding, Z.2    Anderson, A.W.3
  • 8
    • 0030003428 scopus 로고    scopus 로고
    • Determination of muscle fibre orientation using diffusion-weighted MRI
    • van Doorn A, Bovendeerd PH, Nicolay K, et al. (1996) Determination of muscle fibre orientation using diffusion-weighted MRI. Eur J Morphol 34, 5-10.
    • (1996) Eur J Morphol , vol.34 , pp. 5-10
    • van Doorn, A.1    Bovendeerd, P.H.2    Nicolay, K.3
  • 9
    • 49749142004 scopus 로고    scopus 로고
    • Scaling of muscle architecture and fiber types in the rat hindlimb
    • Eng CM, Smallwood LH, Rainiero MP, et al. (2008) Scaling of muscle architecture and fiber types in the rat hindlimb. J Exp Biol 211, 2336-2345.
    • (2008) J Exp Biol , vol.211 , pp. 2336-2345
    • Eng, C.M.1    Smallwood, L.H.2    Rainiero, M.P.3
  • 10
    • 0036184578 scopus 로고    scopus 로고
    • Half-Fourier single-shot STEAM MRI
    • Finsterbusch J, Frahm J (2002) Half-Fourier single-shot STEAM MRI. Magn Reson Med 47, 611-615.
    • (2002) Magn Reson Med , vol.47 , pp. 611-615
    • Finsterbusch, J.1    Frahm, J.2
  • 11
    • 66249109288 scopus 로고    scopus 로고
    • Three-dimensional study of pectoralis major muscle and tendon architecture
    • Fung L, Wong B, Ravichandiran K, et al. (2009) Three-dimensional study of pectoralis major muscle and tendon architecture. Clin Anat 22, 500-508.
    • (2009) Clin Anat , vol.22 , pp. 500-508
    • Fung, L.1    Wong, B.2    Ravichandiran, K.3
  • 12
    • 0020028564 scopus 로고
    • Fiber architecture and muscle function
    • Gans C (1982) Fiber architecture and muscle function. Exerc Sport Sci Rev 10, 160-207.
    • (1982) Exerc Sport Sci Rev , vol.10 , pp. 160-207
    • Gans, C.1
  • 13
    • 0023243401 scopus 로고
    • Functional bases of fiber length and angulation in muscle
    • Gans C, de Vree F (1987) Functional bases of fiber length and angulation in muscle. J Morphol 192, 63-85.
    • (1987) J Morphol , vol.192 , pp. 63-85
    • Gans, C.1    de Vree, F.2
  • 14
    • 0026909877 scopus 로고
    • The isometric length-force models of nine different skeletal muscles
    • Gareis H, Solomonow M, Baratta R, et al. (1992) The isometric length-force models of nine different skeletal muscles. J Biomech 25, 903-916.
    • (1992) J Biomech , vol.25 , pp. 903-916
    • Gareis, H.1    Solomonow, M.2    Baratta, R.3
  • 15
    • 36549064665 scopus 로고    scopus 로고
    • Implementation and electrophysiological validation of combined fMRI and DTI imaging for visualization of cortico-subcortical connectivity
    • Gharabaghi A, Saur R, Kunath F, et al. (2007) Implementation and electrophysiological validation of combined fMRI and DTI imaging for visualization of cortico-subcortical connectivity. Z Med Phys 17, 266-272.
    • (2007) Z Med Phys , vol.17 , pp. 266-272
    • Gharabaghi, A.1    Saur, R.2    Kunath, F.3
  • 16
    • 0034358901 scopus 로고    scopus 로고
    • Three-dimensional analysis of the arrangement and length distribution of fascicles in the triceps muscle of Galea musteloides (Rodentia, Cavimorpha)
    • Gorb SN, Fischer MS (2000) Three-dimensional analysis of the arrangement and length distribution of fascicles in the triceps muscle of Galea musteloides (Rodentia, Cavimorpha). Zoomorphology 1210, 91-97.
    • (2000) Zoomorphology , vol.1210 , pp. 91-97
    • Gorb, S.N.1    Fischer, M.S.2
  • 17
    • 0036335676 scopus 로고    scopus 로고
    • Fiber tracking from DTI using linear state space models: detectability of the pyramidal tract
    • Gossl C, Fahrmeir L, Putz B, et al. (2002) Fiber tracking from DTI using linear state space models: detectability of the pyramidal tract. Neuroimage 16, 378-388.
    • (2002) Neuroimage , vol.16 , pp. 378-388
    • Gossl, C.1    Fahrmeir, L.2    Putz, B.3
  • 18
  • 19
    • 82955209040 scopus 로고    scopus 로고
    • Denoising for diffusion tensor imaging with low signal to noise ratios: method and Monte Carlo validation
    • Hahn KR, Prigarin S, Rodenacker KMH (2010) Denoising for diffusion tensor imaging with low signal to noise ratios: method and Monte Carlo validation. Int J Biomath Biostat, 6, 3-81.
    • (2010) Int J Biomath Biostat , vol.6 , pp. 3-81
    • Hahn, K.R.1    Prigarin, S.2    Rodenacker, K.M.H.3
  • 20
    • 19544365262 scopus 로고    scopus 로고
    • Determination of mouse skeletal muscle architecture using three-dimensional diffusion tensor imaging
    • Heemskerk AM, Strijkers GJ, Vilanova A, et al. (2005) Determination of mouse skeletal muscle architecture using three-dimensional diffusion tensor imaging. Magn Reson Med 53, 1333-1340.
    • (2005) Magn Reson Med , vol.53 , pp. 1333-1340
    • Heemskerk, A.M.1    Strijkers, G.J.2    Vilanova, A.3
  • 21
    • 60549089070 scopus 로고    scopus 로고
    • Quantitative assessment of DTI-based muscle fiber tracking and optimal tracking parameters
    • Heemskerk AM, Sinha TK, Wilson KJ, et al. (2009) Quantitative assessment of DTI-based muscle fiber tracking and optimal tracking parameters. Magn Reson Med 61, 467-472.
    • (2009) Magn Reson Med , vol.61 , pp. 467-472
    • Heemskerk, A.M.1    Sinha, T.K.2    Wilson, K.J.3
  • 22
    • 77949683741 scopus 로고    scopus 로고
    • Repeatability of DTI-based skeletal muscle fiber tracking
    • Heemskerk AM, Sinha TK, Wilson KJ, et al. (2010) Repeatability of DTI-based skeletal muscle fiber tracking. NMR Biomed 23, 294-303.
    • (2010) NMR Biomed , vol.23 , pp. 294-303
    • Heemskerk, A.M.1    Sinha, T.K.2    Wilson, K.J.3
  • 23
    • 84860417786 scopus 로고    scopus 로고
    • Diffusion weighted inner volume imaging of lumbar disks based on turbo-STEAM acquisition
    • Hiepe P, Herrmann KH, Ros C, et al. (2011) Diffusion weighted inner volume imaging of lumbar disks based on turbo-STEAM acquisition. Z Med Phys 21, 216-227.
    • (2011) Z Med Phys , vol.21 , pp. 216-227
    • Hiepe, P.1    Herrmann, K.H.2    Ros, C.3
  • 24
    • 0035384136 scopus 로고    scopus 로고
    • A global optimisation method for robust affine registration of brain images
    • Jenkinson M, Smith S (2001) A global optimisation method for robust affine registration of brain images. Med Image Anal 5, 143-156.
    • (2001) Med Image Anal , vol.5 , pp. 143-156
    • Jenkinson, M.1    Smith, S.2
  • 25
    • 79251620144 scopus 로고    scopus 로고
    • Tractography of peripheral nerves and skeletal muscles
    • Khalil C, Budzik JF, Kermarrec E, et al. (2010) Tractography of peripheral nerves and skeletal muscles. Eur J Radiol 76, 391-397.
    • (2010) Eur J Radiol , vol.76 , pp. 391-397
    • Khalil, C.1    Budzik, J.F.2    Kermarrec, E.3
  • 26
    • 34548504602 scopus 로고    scopus 로고
    • Three-dimensional study of the musculotendinous architecture of supraspinatus and its functional correlations
    • Kim SY, Boynton EL, Ravichandiran K, et al. (2007) Three-dimensional study of the musculotendinous architecture of supraspinatus and its functional correlations. Clin Anat 20, 648-655.
    • (2007) Clin Anat , vol.20 , pp. 648-655
    • Kim, S.Y.1    Boynton, E.L.2    Ravichandiran, K.3
  • 27
    • 29744469838 scopus 로고    scopus 로고
    • Segmentation of the white matter in the brain based on MR-DTI fiber directions
    • Klose U, Erb M, Saur R, et al. (2005) Segmentation of the white matter in the brain based on MR-DTI fiber directions. Z Med Phys 15, 247-255.
    • (2005) Z Med Phys , vol.15 , pp. 247-255
    • Klose, U.1    Erb, M.2    Saur, R.3
  • 28
    • 39049190081 scopus 로고    scopus 로고
    • Computational model of the movement of the human muscles of mastication during opening and closing of the jaw
    • Leon LM, Liebgott B, Agur AM, et al. (2006) Computational model of the movement of the human muscles of mastication during opening and closing of the jaw. Comput Methods Biomech Biomed Engin 9, 387-398.
    • (2006) Comput Methods Biomech Biomed Engin , vol.9 , pp. 387-398
    • Leon, L.M.1    Liebgott, B.2    Agur, A.M.3
  • 29
    • 0024570560 scopus 로고
    • Skeletal muscle architecture of the rabbit hindlimb: functional implications of muscle design
    • Lieber RL, Blevins FT (1989) Skeletal muscle architecture of the rabbit hindlimb: functional implications of muscle design. J Morphol 199, 93-101.
    • (1989) J Morphol , vol.199 , pp. 93-101
    • Lieber, R.L.1    Blevins, F.T.2
  • 30
    • 0033752246 scopus 로고    scopus 로고
    • Functional and clinical significance of skeletal muscle architecture
    • Lieber RL, Friden J (2000) Functional and clinical significance of skeletal muscle architecture. Muscle Nerve 23, 1647-1666.
    • (2000) Muscle Nerve , vol.23 , pp. 1647-1666
    • Lieber, R.L.1    Friden, J.2
  • 31
    • 0043011512 scopus 로고    scopus 로고
    • Intramuscular innervation of the human soleus muscle: a 3D model
    • Loh EY, Agur AM, McKee NH (2003) Intramuscular innervation of the human soleus muscle: a 3D model. Clin Anat 16, 378-382.
    • (2003) Clin Anat , vol.16 , pp. 378-382
    • Loh, E.Y.1    Agur, A.M.2    McKee, N.H.3
  • 32
    • 0027178113 scopus 로고
    • The axial torque of the lumbar back muscles: torsion strength of the back muscles
    • Macintosh JE, Pearcy MJ, Bogduk N (1993) The axial torque of the lumbar back muscles: torsion strength of the back muscles. Aust N Z J Surg 63, 205-212.
    • (1993) Aust N Z J Surg , vol.63 , pp. 205-212
    • Macintosh, J.E.1    Pearcy, M.J.2    Bogduk, N.3
  • 33
    • 0037812473 scopus 로고    scopus 로고
    • Fiber tractography in MR-DTI
    • Masuya Y (2003) Fiber tractography in MR-DTI. Nippon Acta Radiol 63, 8-12.
    • (2003) Nippon Acta Radiol , vol.63 , pp. 8-12
    • Masuya, Y.1
  • 34
    • 84855181446 scopus 로고    scopus 로고
    • Diffusion tensor MRI to assess damage in healthy and dystrophic skeletal muscle after lengthening contractions
    • McMillan AB, Shi D, Pratt SJP, et al. (2011) Diffusion tensor MRI to assess damage in healthy and dystrophic skeletal muscle after lengthening contractions. J Biomed Biotechnol 2011, 10.
    • (2011) J Biomed Biotechnol , vol.2011 , pp. 10
    • McMillan, A.B.1    Shi, D.2    Pratt, S.J.P.3
  • 35
    • 53149120385 scopus 로고    scopus 로고
    • FEM-simulation of skeletal muscle: the influence of inertia during activation and deactivation
    • (ed. Herzog W) -, Chichester: John Wiley & Sons.
    • Meier P, Blickhan R (2000) FEM-simulation of skeletal muscle: the influence of inertia during activation and deactivation. In: Skeletal Muscle Mechanics: From Mechanisms to Function (ed. Herzog W), pp. 207-223, Chichester: John Wiley & Sons.
    • (2000) Skeletal Muscle Mechanics: From Mechanisms to Function , pp. 207-223
    • Meier, P.1    Blickhan, R.2
  • 36
    • 70649090053 scopus 로고    scopus 로고
    • Effect of rotator cuff muscle imbalance on forceful internal impingement and peel-back of the superior labrum: a cadaveric study
    • Mihata T, Gates J, McGarry MH, et al. (2009) Effect of rotator cuff muscle imbalance on forceful internal impingement and peel-back of the superior labrum: a cadaveric study. Am J Sports Med 37, 2222-2227.
    • (2009) Am J Sports Med , vol.37 , pp. 2222-2227
    • Mihata, T.1    Gates, J.2    McGarry, M.H.3
  • 37
    • 33748047806 scopus 로고    scopus 로고
    • Principles of diffusion tensor imaging and its applications to basic neuroscience research
    • Mori S, Zhang J (2006) Principles of diffusion tensor imaging and its applications to basic neuroscience research. Neuron 51, 527-539.
    • (2006) Neuron , vol.51 , pp. 527-539
    • Mori, S.1    Zhang, J.2
  • 38
    • 0033007902 scopus 로고    scopus 로고
    • Three-dimensional tracking of axonal projections in the brain by magnetic resonance imaging
    • Mori S, Crain BJ, Chacko VP, et al. (1999) Three-dimensional tracking of axonal projections in the brain by magnetic resonance imaging. Ann Neurol 45, 265-269.
    • (1999) Ann Neurol , vol.45 , pp. 265-269
    • Mori, S.1    Crain, B.J.2    Chacko, V.P.3
  • 39
    • 0035016041 scopus 로고    scopus 로고
    • Quantitative analysis of three-dimensional-resolved fiber architecture in heterogeneous skeletal muscle tissue using nmr and optical imaging methods
    • Napadow VJ, Chen Q, Mai V, et al. (2001) Quantitative analysis of three-dimensional-resolved fiber architecture in heterogeneous skeletal muscle tissue using nmr and optical imaging methods. Biophys J 80, 2968-2975.
    • (2001) Biophys J , vol.80 , pp. 2968-2975
    • Napadow, V.J.1    Chen, Q.2    Mai, V.3
  • 41
    • 84865021881 scopus 로고    scopus 로고
    • Diffusion property differences of the lower leg musculature between athletes and non-athletes using 1.5T MRI
    • Okamoto Y, Mori S, Kujiraoka Y, et al. (2012) Diffusion property differences of the lower leg musculature between athletes and non-athletes using 1.5T MRI. MAGMA 25, 277-284.
    • (2012) MAGMA , vol.25 , pp. 277-284
    • Okamoto, Y.1    Mori, S.2    Kujiraoka, Y.3
  • 43
    • 0021678840 scopus 로고
    • Predictability of skeletal muscle tension from architectural determinations in guinea pig hindlimbs
    • Powell PL, Roy RR, Kanim P, et al. (1984) Predictability of skeletal muscle tension from architectural determinations in guinea pig hindlimbs. J Appl Physiol 57, 1715-1721.
    • (1984) J Appl Physiol , vol.57 , pp. 1715-1721
    • Powell, P.L.1    Roy, R.R.2    Kanim, P.3
  • 44
    • 77954667483 scopus 로고    scopus 로고
    • Multiplane loading of the extensor mechanism alters the patellar ligament force/quadriceps force ratio
    • Powers CM, Chen YJ, Scher IS, et al. (2010) Multiplane loading of the extensor mechanism alters the patellar ligament force/quadriceps force ratio. J Biomech Eng 132, 024503.
    • (2010) J Biomech Eng , vol.132 , pp. 024503
    • Powers, C.M.1    Chen, Y.J.2    Scher, I.S.3
  • 45
    • 78650329147 scopus 로고    scopus 로고
    • Fibre bundle element method of determining physiological cross-sectional area from three-dimensional computer muscle models created from digitised fibre bundle data
    • Ravichandiran K, Ravichandiran M, Oliver ML, et al. (2010) Fibre bundle element method of determining physiological cross-sectional area from three-dimensional computer muscle models created from digitised fibre bundle data. Comput Methods Biomech Biomed Engin 13, 741-748.
    • (2010) Comput Methods Biomech Biomed Engin , vol.13 , pp. 741-748
    • Ravichandiran, K.1    Ravichandiran, M.2    Oliver, M.L.3
  • 46
    • 0028872003 scopus 로고
    • Imaging myocardial fiber architecture in vivo with magnetic resonance
    • Reese TG, Weisskoff RM, Smith RN, et al. (1995) Imaging myocardial fiber architecture in vivo with magnetic resonance. Magn Reson Med 34, 786-791.
    • (1995) Magn Reson Med , vol.34 , pp. 786-791
    • Reese, T.G.1    Weisskoff, R.M.2    Smith, R.N.3
  • 47
    • 55149085639 scopus 로고    scopus 로고
    • Bridging scales: a three-dimensional electromechanical finite element model of skeletal muscle
    • Röhrle O, Davidson JB, Pullan AJ (2008) Bridging scales: a three-dimensional electromechanical finite element model of skeletal muscle. SIAM J Sci Computing 30, 2882-2904.
    • (2008) SIAM J Sci Computing , vol.30 , pp. 2882-2904
    • Röhrle, O.1    Davidson, J.B.2    Pullan, A.J.3
  • 48
    • 50949085151 scopus 로고    scopus 로고
    • Three-dimensional study of the musculotendinous architecture of lumbar multifidus and its functional implications
    • Rosatelli AL, Ravichandiran K, Agur AM (2008) Three-dimensional study of the musculotendinous architecture of lumbar multifidus and its functional implications. Clin Anat 21, 539-546.
    • (2008) Clin Anat , vol.21 , pp. 539-546
    • Rosatelli, A.L.1    Ravichandiran, K.2    Agur, A.M.3
  • 49
    • 84878983807 scopus 로고    scopus 로고
    • Analyse der paravertebralen Muskulatur kleiner Säugetiere
    • (eds R Grieshaber, W Schneider) -. Leipzig: Monade Agentur für Kommunikation.
    • Schilling N, Stark H, Fischer MS (2003) Analyse der paravertebralen Muskulatur kleiner Säugetiere. In: Prävention von arbeitsbedingten Gesundheitsgefahren und Erkrankungen (eds R Grieshaber, W Schneider ), pp. 343-354. Leipzig: Monade Agentur für Kommunikation.
    • (2003) Prävention von arbeitsbedingten Gesundheitsgefahren und Erkrankungen , pp. 343-354
    • Schilling, N.1    Stark, H.2    Fischer, M.S.3
  • 50
    • 84891332143 scopus 로고    scopus 로고
    • Work partitioning of transversally loaded muscle: experimentation and simulation
    • DOI 10.1080/10255842.2012.675056.
    • Siebert T, Till O, Blickhan R (2012) Work partitioning of transversally loaded muscle: experimentation and simulation. Comput Methods Biomech Biomed Engin, DOI 10.1080/10255842.2012.675056.
    • (2012) Comput Methods Biomech Biomed Engin
    • Siebert, T.1    Till, O.2    Blickhan, R.3
  • 51
    • 33745714408 scopus 로고    scopus 로고
    • In vivo diffusion tensor imaging of the human calf muscle
    • Sinha S, Sinha U, Edgerton VR (2006) In vivo diffusion tensor imaging of the human calf muscle. J Magn Reson Imaging 24, 182-190.
    • (2006) J Magn Reson Imaging , vol.24 , pp. 182-190
    • Sinha, S.1    Sinha, U.2    Edgerton, V.R.3
  • 52
    • 79954575739 scopus 로고    scopus 로고
    • Human soleus muscle architecture at different ankle joint angles from magnetic resonance diffusion tensor imaging
    • Sinha U, Sinha S, Hodgson JA, et al. (2011) Human soleus muscle architecture at different ankle joint angles from magnetic resonance diffusion tensor imaging. J Appl Physiol 110, 807-819.
    • (2011) J Appl Physiol , vol.110 , pp. 807-819
    • Sinha, U.1    Sinha, S.2    Hodgson, J.A.3
  • 53
    • 78149283023 scopus 로고    scopus 로고
    • A novel method of studying fascicle architecture in relaxed and contracted muscles
    • Stark H, Schilling N (2010) A novel method of studying fascicle architecture in relaxed and contracted muscles. J Biomech 43, 2897-2903.
    • (2010) J Biomech , vol.43 , pp. 2897-2903
    • Stark, H.1    Schilling, N.2
  • 55
    • 67549146551 scopus 로고    scopus 로고
    • Diffusion toolkit: a software package for diffusion imaging data processing and tractography
    • Wang R, Benner T, Sorensen AG, et al. (2007) Diffusion toolkit: a software package for diffusion imaging data processing and tractography. Proc Int Soc Mag Reson Med 15, 3720.
    • (2007) Proc Int Soc Mag Reson Med , vol.15 , pp. 3720
    • Wang, R.1    Benner, T.2    Sorensen, A.G.3
  • 56
    • 0009868489 scopus 로고    scopus 로고
    • Noise reduction in images: some recent edge-preserving methods
    • Winkler G, Aurich V, Hahn KR, et al. (1999) Noise reduction in images: some recent edge-preserving methods. J Patt Recog Image Analysis 9(4), 749-766.
    • (1999) J Patt Recog Image Analysis , vol.9 , Issue.4 , pp. 749-766
    • Winkler, G.1    Aurich, V.2    Hahn, K.R.3
  • 57
    • 0242709605 scopus 로고    scopus 로고
    • Extramuscular myofascial force transmission: experiments and finite element modeling
    • Yucesoy CA, Koopman BH, Baan GC, et al. (2003) Extramuscular myofascial force transmission: experiments and finite element modeling. Arch Physiol Biochem 111, 377-388.
    • (2003) Arch Physiol Biochem , vol.111 , pp. 377-388
    • Yucesoy, C.A.1    Koopman, B.H.2    Baan, G.C.3
  • 58
    • 84871504955 scopus 로고    scopus 로고
    • In ovo serial skeletal muscle diffusion tractography of the developing chick embryo using DTI: feasibility and correlation with histology
    • Zhou Z, Delproposto Z, Wu L, et al. (2012) In ovo serial skeletal muscle diffusion tractography of the developing chick embryo using DTI: feasibility and correlation with histology. BMC Dev Biol 12, 38.
    • (2012) BMC Dev Biol , vol.12 , pp. 38
    • Zhou, Z.1    Delproposto, Z.2    Wu, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.