메뉴 건너뛰기




Volumn 60, Issue 6, 2013, Pages 1272-1276

Correspondence: Lead-free intravascular ultrasound transducer using BZT-50BCT ceramics

Author keywords

[No Author keywords available]

Indexed keywords

BIOMEDICAL IMAGING APPLICATIONS; CORONARY ARTERIES; HIGH DIELECTRIC CONSTANTS; HIGH FREQUENCY HF; INTRAVASCULAR IMAGING; INTRAVASCULAR ULTRASOUND; LEAD-FREE PIEZOELECTRIC MATERIALS; PIEZOELECTRIC COEFFICIENT;

EID: 84878780183     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.2013.2692     Document Type: Article
Times cited : (59)

References (22)
  • 1
    • 0034768314 scopus 로고    scopus 로고
    • Correlation between high frequency intravascular ultrasound and histomorphology in human coronary arteries
    • F. Prati, E. Arbustini, A. Labellarte, B. D. Bello, L. Sommariva, M. T. Mallus, A. Pagano, and A. Boccanelli, "Correlation between high frequency intravascular ultrasound and histomorphology in human coronary arteries," Heart, vol. 85, no. 5, pp. 567-570, 2001. (Pubitemid 32973504)
    • (2001) Heart , vol.85 , Issue.5 , pp. 567-570
    • Prati, F.1    Arbustini, E.2    Labellarte, A.3    Dal Bello, B.4    Sommariva, L.5    Mallus, M.T.6    Pagano, A.7    Boccanelli, A.8
  • 2
    • 0035970098 scopus 로고    scopus 로고
    • Intravascular ultrasound: Novel pathophysiological insights and current clinical applications
    • S . E. Nissen and P. Yock, "Intravascular ultrasound novel pathophysiological insights and current clinical applications," Circulation, vol. 103, no. 4, pp. 604-616, 2001. (Pubitemid 32116248)
    • (2001) Circulation , vol.103 , Issue.4 , pp. 604-616
    • Nissen, S.E.1    Yock, P.2
  • 3
    • 67649371687 scopus 로고    scopus 로고
    • 60 MHz PMN-PT based 1-3 composite transducer for IVUS imaging
    • J. Yuan, S. Rhee, and X. N. Jiang, "60 MHz PMN-PT based 1-3 composite transducer for IVUS imaging," in Proc. IEEE Ultrasonics Symp., 2008, pp. 682-685.
    • (2008) Proc. IEEE Ultrasonics Symp. , pp. 682-685
    • Yuan, J.1    Rhee, S.2    Jiang, X.N.3
  • 6
    • 77957658325 scopus 로고    scopus 로고
    • High-resolution coregistered intravascular imaging with integrated ultrasound and optical coherence tomography probe
    • art. no. 133702
    • X. Li, J. C. Yin, C. H. Hu, Q. F. Zhou, K. K. Shung, and Z. P. Chen, "High-resolution coregistered intravascular imaging with integrated ultrasound and optical coherence tomography probe," Appl. Phys. Lett., vol. 97, no. 13, art. no. 133702, 2010.
    • (2010) Appl. Phys. Lett , vol.97 , Issue.13
    • Li, X.1    Yin, J.C.2    Hu, C.H.3    Zhou, Q.F.4    Shung, K.K.5    Chen, Z.P.6
  • 7
    • 84876542570 scopus 로고    scopus 로고
    • Intravascular photoacoustic imaging at 35 and 80 MHz
    • art. no. 106005
    • X. Li, W. Wei, Q. F. Zhou, K. K. Shung, and Z. Chen, "Intravascular photoacoustic imaging at 35 and 80 MHz," J. Biomed. Opt., vol. 17, no. 10, art. no. 106005, 2012.
    • (2012) J. Biomed. Opt , vol.17 , Issue.10
    • Li, X.1    Wei, W.2    Zhou, Q.F.3    Shung, K.K.4    Chen, Z.5
  • 8
    • 2942748658 scopus 로고    scopus 로고
    • Ferroelectric lead magnesium niobate-lead titanate single crystals for ultrasonic hydrophone applications
    • S . T. Lau, K. H. Lam, H. L. W. Chan, C. L. Choy, H. S. Luo, Q. R. Yin, and Z. W. Yin, "Ferroelectric lead magnesium niobate-lead titanate single crystals for ultrasonic hydrophone applications," Mater. Sci. Eng. B, vol. 111, no. 1, pp. 25-30, 2004.
    • (2004) Mater. Sci. Eng. B , vol.111 , Issue.1 , pp. 25-30
    • Lau, S.T.1    Lam, K.H.2    Chan, H.L.W.3    Choy, C.L.4    Luo, H.S.5    Yin, Q.R.6    Yin, Z.W.7
  • 9
    • 33750712084 scopus 로고    scopus 로고
    • PMN-PT single-crystal transducer for non-destructive evaluation
    • DOI 10.1016/j.sna.2006.02.024, PII S092442470600152X
    • G. Edwards, H. L. W. Chan, A. Batten, K. H. Lam, H. S. Luo, and D. A. Scott, "PMN-PT single-crystal transducer for non-destructive evaluation," Sens. Actuators A, vol. 132, no. 2, pp. 434-440, 2006. (Pubitemid 44708668)
    • (2006) Sensors and Actuators, A: Physical , vol.132 , Issue.2 , pp. 434-440
    • Edwards, G.1    Chan, H.L.W.2    Batten, A.3    Lam, K.H.4    Luo, H.S.5    Scott, D.A.6
  • 11
    • 80054682151 scopus 로고    scopus 로고
    • PMN-PT single crystal focusing transducer fabricated using a mechanical dimpling technique
    • K. H. Lam, Y. Chen, K. F. Cheung, and J. Y. Dai, "PMN-PT single crystal focusing transducer fabricated using a mechanical dimpling technique," Ultrasonics, vol. 52, no. 1, pp. 20-24, 2012.
    • (2012) Ultrasonics , vol.52 , Issue.1 , pp. 20-24
    • Lam, K.H.1    Chen, Y.2    Cheung, K.F.3    Dai, J.Y.4
  • 12
    • 84868475279 scopus 로고    scopus 로고
    • A review on lead-free piezoelectric ceramics studies in China
    • Y . Q. Lu and Y. X. Li, "A review on lead-free piezoelectric ceramics studies in China," J. Adv. Dielectr., vol. 1, no. 3, pp. 269-288, 2011.
    • (2011) J. Adv. Dielectr , vol.1 , Issue.3 , pp. 269-288
    • Lu, Y.Q.1    Li, Y.X.2
  • 13
    • 68949194549 scopus 로고    scopus 로고
    • Review: Environmental friendly lead-free piezoelectric materials
    • P. K. Panda, "Review: Environmental friendly lead-free piezoelectric materials," J. Mater. Sci., vol. 44, no. 19, pp. 5049-5062, 2009.
    • (2009) J. Mater. Sci , vol.44 , Issue.19 , pp. 5049-5062
    • Panda, P.K.1
  • 14
    • 78249246358 scopus 로고    scopus 로고
    • Piezoelectric films for high frequency ultrasonic transducers in biomedical applications
    • Q. F. Zhou, S. T. Lau, D. W. Wu, and K. K. Shung, "Piezoelectric films for high frequency ultrasonic transducers in biomedical applications," Prog. Mater. Sci., vol. 56, no. 2, pp. 139-174, 2011.
    • (2011) Prog. Mater. Sci , vol.56 , Issue.2 , pp. 139-174
    • Zhou, Q.F.1    Lau, S.T.2    Wu, D.W.3    Shung, K.K.4
  • 17
    • 72049102611 scopus 로고    scopus 로고
    • Large piezoelectric effect in Pb-free ceramics
    • art. no 257602
    • W. F. Liu and X. B. Ren, "Large piezoelectric effect in Pb-free ceramics," Phys. Rev. Lett., vol. 103, no. 25, art. no. 257602, 2009.
    • (2009) Phys. Rev. Lett , vol.103 , Issue.25
    • Liu, W.F.1    Ren, X.B.2
  • 19
    • 0343415339 scopus 로고
    • Standard methods for testing single-element pulse-echo ultrasonic transducers-AIUM interim standard
    • K. R. Erikson, R. A. Banjavic, and P. L. Carson, "Standard methods for testing single-element pulse-echo ultrasonic transducers-AIUM interim standard," J. Ultrasound Med., vol. 1, suppl. S, pp. 1-18,1981.
    • (1981) J. Ultrasound Med , vol.1 , Issue.SUPPL. S , pp. 1-18
    • Erikson, K.R.1    Banjavic, R.A.2    Carson, P.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.