메뉴 건너뛰기




Volumn 52, Issue 1, 2012, Pages 20-24

PMN-PT single crystal focusing transducer fabricated using a mechanical dimpling technique

Author keywords

Focusing transducer; PMN PT single crystal; Ultrasound

Indexed keywords

ACTIVE ELEMENTS; CRYSTAL SURFACES; CRYSTAL WAFERS; ELECTROMECHANICAL COUPLING COEFFICIENTS; FINITE ELEMENT SIMULATIONS; FOCUSED BEAMS; HIGH RESOLUTION; PLANE TRANSDUCER; PMN-PT SINGLE CRYSTAL; ULTRASOUND TRANSDUCERS;

EID: 80054682151     PISSN: 0041624X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultras.2011.06.004     Document Type: Article
Times cited : (45)

References (23)
  • 2
    • 70350413533 scopus 로고    scopus 로고
    • Embedded piezo-transducer in concrete for property diagnosis
    • Z.J. Li, L. Qin, and S.F. Huang Embedded piezo-transducer in concrete for property diagnosis J. Mater. Civ. Eng. 21 2009 643 647
    • (2009) J. Mater. Civ. Eng. , vol.21 , pp. 643-647
    • Li, Z.J.1    Qin, L.2    Huang, S.F.3
  • 3
    • 76349100980 scopus 로고    scopus 로고
    • Application of electromechanical impedance technique for engineering structures: Review and future issues
    • V.G.M. Annamdas, and C.K. Soh Application of electromechanical impedance technique for engineering structures: review and future issues J. Intell. Mater. Syst. Struct. 21 2010 41 59
    • (2010) J. Intell. Mater. Syst. Struct. , vol.21 , pp. 41-59
    • Annamdas, V.G.M.1    Soh, C.K.2
  • 4
    • 67650733519 scopus 로고    scopus 로고
    • Multiple-frequency ultrasonic imaging by transmitting pulsed waves of two frequencies
    • N. Yoshizumi, S. Saito, D. Koyama, K. Nakamura, A. Ohya, and I. Akiyama Multiple-frequency ultrasonic imaging by transmitting pulsed waves of two frequencies J. Med. Ultrason. 36 2009 53 60
    • (2009) J. Med. Ultrason. , vol.36 , pp. 53-60
    • Yoshizumi, N.1    Saito, S.2    Koyama, D.3    Nakamura, K.4    Ohya, A.5    Akiyama, I.6
  • 7
    • 33947319496 scopus 로고    scopus 로고
    • Self-focused high frequency ultrasonic transducers based on ZnO piezoelectric films
    • Q.F. Zhou, C. Sharp, J.M. Cannata, K.K. Shung, G.H. Feng, and E.S. Kim Self-focused high frequency ultrasonic transducers based on ZnO piezoelectric films Appl. Phys. Lett 90 2007 113502
    • (2007) Appl. Phys. Lett , vol.90 , pp. 113502
    • Zhou, Q.F.1    Sharp, C.2    Cannata, J.M.3    Shung, K.K.4    Feng, G.H.5    Kim, E.S.6
  • 8
    • 34247485510 scopus 로고    scopus 로고
    • Lens-focused transducer modeling using an extended KLM model
    • DOI 10.1016/j.ultras.2007.01.006, PII S0041624X07000194
    • P. Marechal, F. Levassort, L.P. Tran-Huu-Hue, and M. Lethiecq Lens-focused transducer modeling using an extended KLM model Ultrasonics 46 2007 155 167 (Pubitemid 46654145)
    • (2007) Ultrasonics , vol.46 , Issue.2 , pp. 155-167
    • Marechal, P.1    Levassort, F.2    Tran-Huu-Hue, L.-P.3    Lethiecq, M.4
  • 10
    • 77953530412 scopus 로고    scopus 로고
    • Ultrasound focusing using magnetic resonance acoustic radiation force imaging: Application to ultrasound transcranial therapy
    • Y. Hertzberg, A. Volovick, Y. Zur, Y. Medan, S. Vitek, and G. Navon Ultrasound focusing using magnetic resonance acoustic radiation force imaging: application to ultrasound transcranial therapy Med. Phys 37 2010 2934 2942
    • (2010) Med. Phys , vol.37 , pp. 2934-2942
    • Hertzberg, Y.1    Volovick, A.2    Zur, Y.3    Medan, Y.4    Vitek, S.5    Navon, G.6
  • 13
    • 67649312323 scopus 로고    scopus 로고
    • Design and fabrication of a 40 MHz transducer with enhanced bandwidth
    • J. H. Liu, S. Y. Chen and P. C. Li, Design and fabrication of a 40 MHz transducer with enhanced bandwidth, in: Proc. IEEE on Ultra. Symp. 2008, pp. 799-802.
    • (2008) Proc. IEEE on Ultra. Symp. , pp. 799-802
    • Liu, J.H.1    Chen, S.Y.2    Li, P.C.3
  • 14
    • 73349092367 scopus 로고    scopus 로고
    • Broadband poly(vinylidenefiuoride-trifiuoroethylene) ultrasound focusing transducers for determining elastic constants of coating materials
    • C.H. Chung, and Y.C. Lee Broadband poly(vinylidenefiuoride- trifiuoroethylene) ultrasound focusing transducers for determining elastic constants of coating materials J. Nondestruct. Eval 28 2009 101 110
    • (2009) J. Nondestruct. Eval , vol.28 , pp. 101-110
    • Chung, C.H.1    Lee, Y.C.2
  • 16
    • 0031211577 scopus 로고    scopus 로고
    • Ultrahigh strain and piezoelectric behavior in relaxor based ferroelectric single crystals
    • S.E. Park, and T.R. Shrout Ultrahigh strain and piezoelectric behavior in relaxor-based ferroelectric single crystals J. Appl. Phys. 82 1997 1804 1811 (Pubitemid 127590063)
    • (1997) Journal of Applied Physics , vol.82 , Issue.4 , pp. 1804-1811
    • Park, S.-E.1    Shrout, T.R.2
  • 17
    • 67249135682 scopus 로고    scopus 로고
    • Multiple matching scheme for broadband transducer 0.72Pb(Mg1/3Nb2/3)O-3- 0.28PbTiO(3) single crystal phased-array
    • S.T. Lau, H. Li, K.S. Wong, Q.F. Zhou, D. Zhou, Y.C. Li, H.S. Luo, K.K. Shung, and J.Y. Dai Multiple matching scheme for broadband transducer 0.72Pb(Mg1/3Nb2/3)O-3-0.28PbTiO(3) single crystal phased-array J. Appl. Phys 105 2009 094908
    • (2009) J. Appl. Phys , vol.105 , pp. 094908
    • Lau, S.T.1    Li, H.2    Wong, K.S.3    Zhou, Q.F.4    Zhou, D.5    Li, Y.C.6    Luo, H.S.7    Shung, K.K.8    Dai, J.Y.9
  • 19
    • 0013231056 scopus 로고    scopus 로고
    • Study of new piezoelectric material-relaxor ferroelectric single crystals
    • H. Luo, G. Shen, P. Wang, X. Le, and Z. Yin Study of new piezoelectric material-relaxor ferroelectric single crystals J. Inorg. Mater. 12 1997 768
    • (1997) J. Inorg. Mater. , vol.12 , pp. 768
    • Luo, H.1    Shen, G.2    Wang, P.3    Le, X.4    Yin, Z.5
  • 22
    • 0026838720 scopus 로고
    • Calculation of pressure fields from arbitrarily shaped apodized, and excited ultrasound transducers
    • J.A. Jensen, and J.B. Svendsen Calculation of pressure fields from arbitrarily shaped apodized, and excited ultrasound transducers IEEE Trans. Ultrason. Ferroelec. Freq. Control 39 1992 262 267
    • (1992) IEEE Trans. Ultrason. Ferroelec. Freq. Control , vol.39 , pp. 262-267
    • Jensen, J.A.1    Svendsen, J.B.2
  • 23
    • 0343415339 scopus 로고
    • Standard methods for testing single-element transducers - AIUM Interim Standard
    • K.R. Erikson, R.A. Banjavic, and P.L. Carson Standard methods for testing single-element transducers - AIUM Interim Standard J. Ultrasound Med. 1 1982 S1 18
    • (1982) J. Ultrasound Med. , vol.1 , pp. 1-18
    • Erikson, K.R.1    Banjavic, R.A.2    Carson, P.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.