메뉴 건너뛰기




Volumn 8, Issue 5, 2013, Pages

Prospective ECG-Triggered Coronary CT Angiography: Clinical Value of Noise-Based Tube Current Reduction Method with Iterative Reconstruction

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ARTICLE; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; CONTROLLED STUDY; CORONARY COMPUTED TOMOGRAPHIC ANGIOGRAPHY; DIAGNOSTIC VALUE; ELECTRIC POTENTIAL; ELECTROCARDIOGRAPHY; FEMALE; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; IMAGE RECONSTRUCTION; MAJOR CLINICAL STUDY; MALE; NOISE REDUCTION; PROSPECTIVE STUDY; QUALITATIVE ANALYSIS; RADIATION DOSE REDUCTION; RANDOMIZED CONTROLLED TRIAL; SIGNAL DETECTION; SIGNAL NOISE RATIO;

EID: 84878614280     PISSN: None     EISSN: 19326203     Source Type: Journal    
DOI: 10.1371/journal.pone.0065025     Document Type: Article
Times cited : (13)

References (23)
  • 2
    • 33645749654 scopus 로고    scopus 로고
    • Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates
    • Hausleiter J, Meyer T, Hadamitzky M, Huber E, Zankl M, et al. (2006) Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates. Circulation 113: 1305-1310.
    • (2006) Circulation , vol.113 , pp. 1305-1310
    • Hausleiter, J.1    Meyer, T.2    Hadamitzky, M.3    Huber, E.4    Zankl, M.5
  • 3
    • 34447558140 scopus 로고    scopus 로고
    • Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography
    • Einstein AJ, Henzlova MJ, Rajagopalan S, (2007) Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography. JAMA 298: 317-323.
    • (2007) JAMA , vol.298 , pp. 317-323
    • Einstein, A.J.1    Henzlova, M.J.2    Rajagopalan, S.3
  • 4
    • 33750547401 scopus 로고    scopus 로고
    • Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography
    • Hsieh J, Londt J, Vass M, Li J, Tang X, et al. (2006) Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography. Med Phys 33: 4236-4248.
    • (2006) Med Phys , vol.33 , pp. 4236-4248
    • Hsieh, J.1    Londt, J.2    Vass, M.3    Li, J.4    Tang, X.5
  • 5
    • 84855588423 scopus 로고    scopus 로고
    • Prospective versus retrospective ECG-gated multislice CT coronary angiography: a systematic review of radiation dose and diagnostic accuracy
    • Sun Z, Ng KH, (2012) Prospective versus retrospective ECG-gated multislice CT coronary angiography: a systematic review of radiation dose and diagnostic accuracy. Eur J Radiol 81: e94-e100.
    • (2012) Eur J Radiol , vol.81
    • Sun, Z.1    Ng, K.H.2
  • 6
    • 84861150020 scopus 로고    scopus 로고
    • Image quality and radiation exposure with prospectively ECG-triggered axial scanning for coronary CT angiography: the multicenter, multivendor, randomized PROTECTION-III study
    • Hausleiter J, Meyer TS, Martuscelli E, Spagnolo P, Yamamoto H, et al. (2012) Image quality and radiation exposure with prospectively ECG-triggered axial scanning for coronary CT angiography: the multicenter, multivendor, randomized PROTECTION-III study. JACC Cardiovasc Imaging 5: 484-493.
    • (2012) JACC Cardiovasc Imaging , vol.5 , pp. 484-493
    • Hausleiter, J.1    Meyer, T.S.2    Martuscelli, E.3    Spagnolo, P.4    Yamamoto, H.5
  • 7
    • 84856605802 scopus 로고    scopus 로고
    • CT image quality improvement using Adaptive Iterative Dose Reduction with wide-volume acquisition on 320-detector CT
    • Gervaise A, Osemont B, Lecocq S, Noel A, Micard E, et al. (2012) CT image quality improvement using Adaptive Iterative Dose Reduction with wide-volume acquisition on 320-detector CT. Eur Radiol 22: 295-301.
    • (2012) Eur Radiol , vol.22 , pp. 295-301
    • Gervaise, A.1    Osemont, B.2    Lecocq, S.3    Noel, A.4    Micard, E.5
  • 8
    • 79751531405 scopus 로고    scopus 로고
    • Computed tomography-old ideas and new technology
    • Fleischmann D, Boas FE, (2011) Computed tomography-old ideas and new technology. Eur Radiol 21: 510-517.
    • (2011) Eur Radiol , vol.21 , pp. 510-517
    • Fleischmann, D.1    Boas, F.E.2
  • 9
    • 69949096664 scopus 로고    scopus 로고
    • Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study
    • Hara AK, Paden RG, Silva AC, Kujak JL, Lawder HJ, et al. (2009) Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study. AJR Am J Roentgenol 193: 764-771.
    • (2009) AJR Am J Roentgenol , vol.193 , pp. 764-771
    • Hara, A.K.1    Paden, R.G.2    Silva, A.C.3    Kujak, J.L.4    Lawder, H.J.5
  • 10
    • 73449113287 scopus 로고    scopus 로고
    • Method for automatic tube current selection for obtaining a consistent image quality and dose optimization in a cardiac multidetector CT
    • Qi W, Li J, Du X, (2009) Method for automatic tube current selection for obtaining a consistent image quality and dose optimization in a cardiac multidetector CT. Korean J Radiol 10: 568-574.
    • (2009) Korean J Radiol , vol.10 , pp. 568-574
    • Qi, W.1    Li, J.2    Du, X.3
  • 11
    • 77956825812 scopus 로고    scopus 로고
    • Adaptive statistical iterative reconstruction: assessment of image noise and image quality in coronary CT angiography
    • Leipsic J, Labounty TM, Heilbron B, Min JK, Mancini GB, et al. (2010) Adaptive statistical iterative reconstruction: assessment of image noise and image quality in coronary CT angiography. AJR Am J Roentgenol 195: 649-654.
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 649-654
    • Leipsic, J.1    Labounty, T.M.2    Heilbron, B.3    Min, J.K.4    Mancini, G.B.5
  • 12
    • 84871920983 scopus 로고    scopus 로고
    • Noise-based tube current reduction method with iterative reconstruction for reduction of radiation exposure in coronary CT angiography
    • Shen J, Du X, Guo D, Cao L, Gao Y, et al. (2012) Noise-based tube current reduction method with iterative reconstruction for reduction of radiation exposure in coronary CT angiography. Eur J Radiol. http://dx.doi.org/10.1016/j.ejrad.2012.10.008.
    • (2012) Eur J Radiol
    • Shen, J.1    Du, X.2    Guo, D.3    Cao, L.4    Gao, Y.5
  • 15
    • 59649127716 scopus 로고    scopus 로고
    • Estimated radiation dose associated with cardiac CT angiography
    • Hausleiter J, Meyer T, Hermann F, Hadamitzky M, Krebs M, et al. (2009) Estimated radiation dose associated with cardiac CT angiography. JAMA 301: 500-507.
    • (2009) JAMA , vol.301 , pp. 500-507
    • Hausleiter, J.1    Meyer, T.2    Hermann, F.3    Hadamitzky, M.4    Krebs, M.5
  • 16
    • 56949100981 scopus 로고    scopus 로고
    • Narrowing the phase window width in prospectively ECG-gated single heart beat 320-detector row coronary CT angiography
    • Steigner ML, Otero HJ, Cai T, Mitsouras D, Nallamshetty L, et al. (2009) Narrowing the phase window width in prospectively ECG-gated single heart beat 320-detector row coronary CT angiography. Int J Cardiovasc Imaging 25: 85-90.
    • (2009) Int J Cardiovasc Imaging , vol.25 , pp. 85-90
    • Steigner, M.L.1    Otero, H.J.2    Cai, T.3    Mitsouras, D.4    Nallamshetty, L.5
  • 17
    • 67849090536 scopus 로고    scopus 로고
    • Low-dose prospectively gated 256-slice coronary computed tomographic angiography
    • Weigold W, Olszewski M, Walker MJ (2009) Low-dose prospectively gated 256-slice coronary computed tomographic angiography. Int J Cardiovasc Imaging (suppl 2): 217-230.
    • (2009) Int J Cardiovasc Imaging , Issue.SUPPL. 2 , pp. 217-230
    • Weigold, W.1    Olszewski, M.2    Walker, M.J.3
  • 18
    • 63049134660 scopus 로고    scopus 로고
    • Evaluation of a body mass index-adapted protocol for low-dose 64-MDCT coronary angiography with prospective ECG triggering
    • Tatsugami F, Husmann L, Herzog BA, Burkhard N, Valenta I, et al. (2009) Evaluation of a body mass index-adapted protocol for low-dose 64-MDCT coronary angiography with prospective ECG triggering. AJR Am J Roentgenol 192: 635-638.
    • (2009) AJR Am J Roentgenol , vol.192 , pp. 635-638
    • Tatsugami, F.1    Husmann, L.2    Herzog, B.A.3    Burkhard, N.4    Valenta, I.5
  • 19
    • 79958139045 scopus 로고    scopus 로고
    • Use of 100 kV versus 120 kV in cardiac dual source computed tomography: effect on radiation dose and image quality
    • Blankstein R, Bolen MA, Pale R, Murphy MK, Shah AB, et al. (2011) Use of 100 kV versus 120 kV in cardiac dual source computed tomography: effect on radiation dose and image quality. Int J Cardiovasc Imaging 27: 579-586.
    • (2011) Int J Cardiovasc Imaging , vol.27 , pp. 579-586
    • Blankstein, R.1    Bolen, M.A.2    Pale, R.3    Murphy, M.K.4    Shah, A.B.5
  • 20
    • 34347226381 scopus 로고    scopus 로고
    • Uniform image quality achieved by tube current modulation using SD of attenuation in coronary CT angiography
    • Hur G, Hong SW, Kim SY, Kim YH, Hwang YJ, et al. (2007) Uniform image quality achieved by tube current modulation using SD of attenuation in coronary CT angiography. AJR Am J Roentgenol 189: 188-196.
    • (2007) AJR Am J Roentgenol , vol.189 , pp. 188-196
    • Hur, G.1    Hong, S.W.2    Kim, S.Y.3    Kim, Y.H.4    Hwang, Y.J.5
  • 21
    • 77956832667 scopus 로고    scopus 로고
    • Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: the ERASIR study
    • Leipsic J, Labounty TM, Heilbron B, Min JK, Mancini GB, et al. (2010) Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: the ERASIR study. AJR Am J Roentgenol 195: 655-660.
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 655-660
    • Leipsic, J.1    Labounty, T.M.2    Heilbron, B.3    Min, J.K.4    Mancini, G.B.5
  • 22
    • 84869875841 scopus 로고    scopus 로고
    • The optimal dose reduction level using iterative reconstruction with prospective ECG-triggered coronary CTA using 256-slice MDCT
    • Hou Y, Xu S, Guo W, Vembar M, Guo Q, (2012) The optimal dose reduction level using iterative reconstruction with prospective ECG-triggered coronary CTA using 256-slice MDCT. Eur J Radiol 81: 3905-3911.
    • (2012) Eur J Radiol , vol.81 , pp. 3905-3911
    • Hou, Y.1    Xu, S.2    Guo, W.3    Vembar, M.4    Guo, Q.5
  • 23
    • 84856974997 scopus 로고    scopus 로고
    • Coronary artery plaques: cardiac CT with model-based and adaptive-statistical iterative reconstruction technique
    • Scheffel H, Stolzmann P, Schlett CL, Engel LC, Major GP, et al. (2012) Coronary artery plaques: cardiac CT with model-based and adaptive-statistical iterative reconstruction technique. Eur J Radiol 81: e363-e369.
    • (2012) Eur J Radiol , vol.81
    • Scheffel, H.1    Stolzmann, P.2    Schlett, C.L.3    Engel, L.C.4    Major, G.P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.