메뉴 건너뛰기




Volumn 51, Issue 6, 2013, Pages 1685-1691

Rapid detection of human immunodeficiency virus types 1 and 2 by use of an improved piezoelectric biosensor

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ARTICLE; BIOSENSOR; DIAGNOSTIC TEST ACCURACY STUDY; HIV TEST; HUMAN; HUMAN IMMUNODEFICIENCY VIRUS 1; HUMAN IMMUNODEFICIENCY VIRUS 2; LIMIT OF DETECTION; NONHUMAN; NUCLEIC ACID AMPLIFICATION; PIEZOELECTRIC BIOSENSOR; POINT OF CARE TESTING; POLYMERASE CHAIN REACTION; PRIORITY JOURNAL; RAPID TEST; SENSITIVITY AND SPECIFICITY; VIRUS DETECTION; VIRUS LOAD;

EID: 84878499483     PISSN: 00951137     EISSN: 1098660X     Source Type: Journal    
DOI: 10.1128/JCM.03041-12     Document Type: Article
Times cited : (22)

References (29)
  • 2
    • 44449146690 scopus 로고    scopus 로고
    • Postexposure immunization and prophylaxis of bloodborne pathogens following a traumatic explosive event: Preliminary recommendations
    • Subbarao I, Steinbrecher R, Tan L, Peleg K, Zeiger J, James JJ. 2007. Postexposure immunization and prophylaxis of bloodborne pathogens following a traumatic explosive event: preliminary recommendations. Disaster Med. Public Health Prep. 1:106-109.
    • (2007) Disaster Med. Public Health Prep. , vol.1 , pp. 106-109
    • Subbarao, I.1    Steinbrecher, R.2    Tan, L.3    Peleg, K.4    Zeiger, J.5    James, J.J.6
  • 3
    • 70449356839 scopus 로고    scopus 로고
    • Poor sensitivity of field rapid HIV testing: Implications for mother-to-child transmission programme
    • Black V, von Mollendorf CE, Moyes JA, Scott LE, Puren A, Stevens WS. 2009. Poor sensitivity of field rapid HIV testing: implications for mother-to-child transmission programme. BJOG 116:1805-1808.
    • (2009) BJOG , vol.116 , pp. 1805-1808
    • Black, V.1    Von Mollendorf, C.E.2    Moyes, J.A.3    Scott, L.E.4    Puren, A.5    Stevens, W.S.6
  • 4
    • 35348983426 scopus 로고    scopus 로고
    • Surface acoustic wave sensors in the bioanalytical field: Recent trends and challenges
    • DOI 10.1016/j.aca.2007.09.056, PII S0003267007016078
    • Gronewold TM. 2007. Surface acoustic wave sensors in the bioanalytical field: recent trends and challenges. Anal. Chim. Acta 603:119-128. (Pubitemid 47600118)
    • (2007) Analytica Chimica Acta , vol.603 , Issue.2 , pp. 119-128
    • Gronewold, T.M.A.1
  • 5
    • 79954778134 scopus 로고    scopus 로고
    • Point-of-care nucleic acid testing for infectious diseases
    • Niemz A, Ferguson TM, Boyle DS. 2011. Point-of-care nucleic acid testing for infectious diseases. Trends Biotechnol. 29:240-250.
    • (2011) Trends Biotechnol. , vol.29 , pp. 240-250
    • Niemz, A.1    Ferguson, T.M.2    Boyle, D.S.3
  • 6
    • 85126151667 scopus 로고    scopus 로고
    • Surface generated acoustic wave biosensors for the detection of pathogens: A review
    • Rocha-Gaso MI, March-Iborra C, Montoya-Baides A, Arnau-Vives A. 2009. Surface generated acoustic wave biosensors for the detection of pathogens: a review. Sensors 9:5740-5769.
    • (2009) Sensors , vol.9 , pp. 5740-5769
    • Rocha-Gaso, M.I.1    March-Iborra, C.2    Montoya-Baides, A.3    Arnau-Vives, A.4
  • 7
    • 45849085364 scopus 로고    scopus 로고
    • Surface acoustic wave biosensors: A review
    • Länge K, Rapp BE, Rapp M. 2008. Surface acoustic wave biosensors: a review. Anal. Biol. Chem. 391:1509-1519.
    • (2008) Anal. Biol. Chem. , vol.391 , pp. 1509-1519
    • Länge, K.1    Rapp, B.E.2    Rapp, M.3
  • 8
    • 58149174428 scopus 로고    scopus 로고
    • Biosensors for biomarkers in medical diagnostics
    • Mascini M, Tombelli S. 2008. Biosensors for biomarkers in medical diagnostics. Biomarkers 13:637-657.
    • (2008) Biomarkers , vol.13 , pp. 637-657
    • Mascini, M.1    Tombelli, S.2
  • 9
    • 55749084734 scopus 로고    scopus 로고
    • Acoustic wave-based detection in bioanalytical chemistry: Competition for surface plasmon resonance?
    • Sheikh S, Blaszykowski C, Thompson M. 2008. Acoustic wave-based detection in bioanalytical chemistry: competition for surface plasmon resonance? Anal. Lett. 41:2525-2538.
    • (2008) Anal. Lett. , vol.41 , pp. 2525-2538
    • Sheikh, S.1    Blaszykowski, C.2    Thompson, M.3
  • 10
    • 84857363887 scopus 로고    scopus 로고
    • Acoustic wave based MEMS devices for biosensing applications
    • Voiculescu I, Nordin AN. 2012. Acoustic wave based MEMS devices for biosensing applications. Biosens. Bioelectron. 33:1-9.
    • (2012) Biosens. Bioelectron. , vol.33 , pp. 1-9
    • Voiculescu, I.1    Nordin, A.N.2
  • 11
    • 1042298974 scopus 로고    scopus 로고
    • 3
    • DOI 10.1016/j.bios.2003.08.020
    • Branch DW, Brozik SM. 2004. Low-level detection of a Bacillus anthracis simulant using Love-wave biosensors on 36 degrees YX LiTaO3. Biosens. Bioelectron. 19:849-859. (Pubitemid 38201335)
    • (2004) Biosensors and Bioelectronics , vol.19 , Issue.8 , pp. 849-859
    • Branch, D.W.1    Brozik, S.M.2
  • 13
    • 24944535421 scopus 로고    scopus 로고
    • Isolation and quantification of HIV from lymph nodes
    • Tamalet C. 2005. Isolation and quantification of HIV from lymph nodes. Methods Mol. Biol. 304:87-94.
    • (2005) Methods Mol. Biol. , vol.304 , pp. 87-94
    • Tamalet, C.1
  • 15
    • 76649092701 scopus 로고    scopus 로고
    • UNAIDS/WHO. UNAIDS/WHO, Geneva, Switzerland
    • UNAIDS/WHO. 2008. Report on the global AIDS epidemic. UNAIDS/WHO, Geneva, Switzerland.
    • (2008) Report on the Global AIDS Epidemic
  • 16
    • 63449124466 scopus 로고    scopus 로고
    • Emerging concepts in the immunopathogenesis of AIDS
    • 18947296
    • Douek DC, Roederer M, Koup RA. 2009. Emerging concepts in the immunopathogenesis of AIDS. Annu. Rev. Med. 60:471-484. 18947296.
    • (2009) Annu. Rev. Med. , vol.60 , pp. 471-484
    • Douek, D.C.1    Roederer, M.2    Koup, R.A.3
  • 17
    • 79961046007 scopus 로고    scopus 로고
    • HIV-2 Infection Surveillance - United States, 1987-2009
    • Centers for Disease Control and Prevention
    • Centers for Disease Control and Prevention. 2011. HIV-2 Infection Surveillance - United States, 1987-2009. MMWR Morb. Mortal. Wkly. Rep. 60:985-988.
    • (2011) MMWR Morb. Mortal. Wkly. Rep. , vol.60 , pp. 985-988
  • 19
    • 84856414956 scopus 로고    scopus 로고
    • Special aspects of the treatment of HIV-2-infected patients
    • Camacho RJ. 2012. Special aspects of the treatment of HIV-2-infected patients. Intervirology 55:179-183.
    • (2012) Intervirology , vol.55 , pp. 179-183
    • Camacho, R.J.1
  • 20
    • 84861700063 scopus 로고    scopus 로고
    • Novel agents for the treatment of HIV-2 infection
    • Peterson K, Rowland-Jones S. 2012. Novel agents for the treatment of HIV-2 infection. Antivir. Ther. 17:435-438.
    • (2012) Antivir. Ther. , vol.17 , pp. 435-438
    • Peterson, K.1    Rowland-Jones, S.2
  • 21
    • 79952138726 scopus 로고    scopus 로고
    • An underestimated lentivirus model: What can HIV-2 research contribute to the development of an effective HIV-1 vaccine?
    • Hodges-Mameletzis I, De Bree GJ, Rowland-Jones SL. 2011. An underestimated lentivirus model: what can HIV-2 research contribute to the development of an effective HIV-1 vaccine? Expert Rev. Anti Infect. Ther. 9:195-206.
    • (2011) Expert Rev. Anti Infect. Ther. , vol.9 , pp. 195-206
    • Hodges-Mameletzis, I.1    De Bree, G.J.2    Rowland-Jones, S.L.3
  • 22
    • 33646589636 scopus 로고    scopus 로고
    • Development and evaluation of a real-time RT-PCR assay for quantification of cell-free human immunodeficiency virus type 2 using a Brome Mosaic Virus internal control
    • DOI 10.1016/j.jviromet.2006.02.005, PII S0166093406000590
    • Ferns RB, Garson JA. 2006. Development and evaluation of a real-time RT-PCR assay for quantification of cell-free human immunodeficiency virus type 2 using a Brome Mosaic Virus internal control. J. Virol. Methods 135:102-108. (Pubitemid 43728849)
    • (2006) Journal of Virological Methods , vol.135 , Issue.1 , pp. 102-108
    • Ferns, R.B.1    Garson, J.A.2
  • 24
    • 0032810236 scopus 로고    scopus 로고
    • Immunosensing of photoimmobilized proteins on surface acoustic wave sensors
    • DOI 10.1016/S0927-7765(99)00047-8, PII S0927776599000478
    • Wessa T, Rapp M, Sigrist H. 1999. Immunosensing of photoimmobilized proteins on surface acoustic wave sensors. Colloids Surf. B Biointerfaces 15:139-146. (Pubitemid 29393108)
    • (1999) Colloids and Surfaces B: Biointerfaces , vol.15 , Issue.2 , pp. 139-146
    • Wessa, T.1    Rapp, M.2    Sigrist, H.3
  • 26
    • 49549117777 scopus 로고    scopus 로고
    • A shear horizontal surface acoustic wave sensor for the detection of antigen-antibody reactions for medical diagnosis
    • Rupp S, von Schickfus M, Hunklinger S, Eipel H, Priebe A, Enders D, Pucci A. 2008. A shear horizontal surface acoustic wave sensor for the detection of antigen-antibody reactions for medical diagnosis. Sensors Actuators 134:225-229.
    • (2008) Sensors Actuators , vol.134 , pp. 225-229
    • Rupp, S.1    Von Schickfus, M.2    Hunklinger, S.3    Eipel, H.4    Priebe, A.5    Enders, D.6    Pucci, A.7
  • 27
    • 79958117429 scopus 로고    scopus 로고
    • New oligoethylene glycol linkers for the surface modification of an ultrahigh frequency acoustic wave biosensor
    • Sheikh S, Chih-Chieh Sheng J, Blaszykowski C, Thompson M. 2010. New oligoethylene glycol linkers for the surface modification of an ultrahigh frequency acoustic wave biosensor. Chem. Sci. 1:271-275.
    • (2010) Chem. Sci. , vol.1 , pp. 271-275
    • Sheikh, S.1    Chih-Chieh Sheng, J.2    Blaszykowski, C.3    Thompson, M.4
  • 28
    • 79958178404 scopus 로고    scopus 로고
    • Label-free detection of HIV-2 antibodies in serum with an ultra-high frequency acoustic wave sensor
    • Sheikh S, Blaszykowski C, Thompson M. 2011. Label-free detection of HIV-2 antibodies in serum with an ultra-high frequency acoustic wave sensor. Talanta 85:816-819.
    • (2011) Talanta , vol.85 , pp. 816-819
    • Sheikh, S.1    Blaszykowski, C.2    Thompson, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.