메뉴 건너뛰기




Volumn 91, Issue 4, 2013, Pages

Biomechanical diagnosis of keratoconus: Evaluation of the keratoconus match index and the keratoconus match probability

Author keywords

keratoconus; keratoconus match index; keratoconus probability index; Ocular Response Analyser; Pentacam; Scheimpflug camera

Indexed keywords

ADULT; AMSLER KRUMEICH CLASSIFICATION; ARTICLE; BIOMECHANICS; CENTRAL CORNEAL THICKNESS; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; DIAGNOSTIC VALUE; DISEASE CLASSIFICATION; DISEASE SEVERITY; EYE EXAMINATION; HUMAN; INTRAOCULAR PRESSURE; KERATOCONUS; KERATOCONUS MATCH INDEX; KERATOCONUS MATCH PROBABILITY; KERATOMETRY; MAJOR CLINICAL STUDY; NAMED INVENTORIES, QUESTIONNAIRES AND RATING SCALES; OPHTHALMOLOGICAL EQUIPMENT; PREDICTIVE VALUE; PRIORITY JOURNAL; RECEIVER OPERATING CHARACTERISTIC; SENSITIVITY AND SPECIFICITY; VISUAL SYSTEM PARAMETERS;

EID: 84878453230     PISSN: 1755375X     EISSN: 17553768     Source Type: Journal    
DOI: 10.1111/aos.12056     Document Type: Article
Times cited : (44)

References (17)
  • 2
    • 33745216716 scopus 로고    scopus 로고
    • Corneal higher order aberrations: A method to grade keratoconus
    • Alio JL, &, Shabayek MH, (2006): Corneal higher order aberrations: a method to grade keratoconus. J Refract Surg 22: 539-545.
    • (2006) J Refract Surg , vol.22 , pp. 539-545
    • Alio, J.L.1    Shabayek, M.H.2
  • 4
    • 0022577146 scopus 로고
    • A 48-year clinical and epidemiologic study of keratoconus
    • Kennedy RH, Bourne WM, &, Dyer JA, (1986): A 48-year clinical and epidemiologic study of keratoconus. Am J Ophthalmol 101: 267-273.
    • (1986) Am J Ophthalmol , vol.101 , pp. 267-273
    • Kennedy, R.H.1    Bourne, W.M.2    Dyer, J.A.3
  • 5
    • 46949110019 scopus 로고    scopus 로고
    • Corneal hysteresis and corneal resistance factor in keratectasia: Finding using the Reichert ocular response analyser
    • Kirwan C, Omalley D, &, O' Keefe M, (2008): Corneal hysteresis and corneal resistance factor in keratectasia: finding using the Reichert ocular response analyser. Opthalmologica 222: 334-337.
    • (2008) Opthalmologica , vol.222 , pp. 334-337
    • Kirwan, C.1    Omalley, D.2    Keefe M, O.'.3
  • 6
    • 79955039196 scopus 로고    scopus 로고
    • Reproducibility of viscoelastic property and intraocular pressure measurements obtained with the Ocular Response Analyzer
    • Kopito R, Gaujoux T, Montard R, Touzeau O, Allouch C, Borderie V, &, Laroche L, (2011): Reproducibility of viscoelastic property and intraocular pressure measurements obtained with the Ocular Response Analyzer. Acta Ophthalmol 89: 225-230.
    • (2011) Acta Ophthalmol , vol.89 , pp. 225-230
    • Kopito, R.1    Gaujoux, T.2    Montard, R.3    Touzeau, O.4    Allouch, C.5    Borderie, V.6    Laroche, L.7
  • 7
    • 77953655709 scopus 로고    scopus 로고
    • Anterior chamber characteristics of keratoconus assessed by rotating Scheimpflug imaging
    • Kovács I, Miháltz K, Németh J, &, Nagy ZZ, (2010): Anterior chamber characteristics of keratoconus assessed by rotating Scheimpflug imaging. J Cataract Refract Surg 36: 1101-1106.
    • (2010) J Cataract Refract Surg , vol.36 , pp. 1101-1106
    • Kovács, I.1    Miháltz, K.2    Németh, J.3    Nagy, Z.Z.4
  • 9
    • 7044235467 scopus 로고    scopus 로고
    • Quality of life in keratoconus; The Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study Group
    • Kymes SM, Walline JJ, Zadnik K, &, Gordon MO, (2004): Quality of life in keratoconus; the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study Group. Am J Ophthalmol 138: 527-535.
    • (2004) Am J Ophthalmol , vol.138 , pp. 527-535
    • Kymes, S.M.1    Walline, J.J.2    Zadnik, K.3    Gordon, M.O.4
  • 10
    • 13844317411 scopus 로고    scopus 로고
    • Determining in-vivo biomechanical properties of the cornea with an ocular response analyzer
    • Luce D, (2005): Determining in-vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg 31: 156-162.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 156-162
    • Luce, D.1
  • 12
    • 77951941860 scopus 로고    scopus 로고
    • Corneal volume, pachymetry, and correlation of anterior and posterior corneal shape in subclinical and different stages of clinical keratoconus
    • Piñero DP, Alió JL, Alesón A, Escaf Vergara M, &, Miranda M, (2010): Corneal volume, pachymetry, and correlation of anterior and posterior corneal shape in subclinical and different stages of clinical keratoconus. J Cataract Refract Surg 36: 814-825.
    • (2010) J Cataract Refract Surg , vol.36 , pp. 814-825
    • Piñero, D.P.1    Alió, J.L.2    Alesón, A.3    Escaf Vergara, M.4    Miranda, M.5
  • 13
    • 84887018331 scopus 로고
    • Major review keratoconus
    • Rabinowitz YS, (1987): Major review keratoconus. Surv Ophthalmol 42: 297-319.
    • (1987) Surv Ophthalmol , vol.42 , pp. 297-319
    • Rabinowitz, Y.S.1
  • 15
    • 34548022426 scopus 로고    scopus 로고
    • Assessment of biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes
    • Shah S, Laiquzzaman M, Bhojwani R, Mantry S, &, Cunliffe I, (2007): Assessment of biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes. Invest Ophthalmol Vis Sci 48: 3026-3031.
    • (2007) Invest Ophthalmol Vis Sci , vol.48 , pp. 3026-3031
    • Shah, S.1    Laiquzzaman, M.2    Bhojwani, R.3    Mantry, S.4    Cunliffe, I.5
  • 16
    • 50549178869 scopus 로고
    • Electron microscopic study of the pathology of keratoconus. Part 1
    • Teng CC, (1963): Electron microscopic study of the pathology of keratoconus. Part 1. Am J Ophthalmol 55: 18-47.
    • (1963) Am J Ophthalmol , vol.55 , pp. 18-47
    • Teng, C.C.1