메뉴 건너뛰기




Volumn 27, Issue 3, 2013, Pages 281-288

Reference values for volumetric capnography-derived non-invasive parameters in healthy individuals

Author keywords

CO2; Dead space; Mechanical ventilation; Slope of phase III; Volumetric capnography

Indexed keywords

DEAD SPACE; HEALTHY INDIVIDUALS; HEALTHY VOLUNTEERS; INTER QUARTILE RANGES; MECHANICAL VENTILATION; RESPIRATORY RATE; SLOPE OF PHASE III; VOLUMETRIC CAPNOGRAPHY;

EID: 84878332567     PISSN: 13871307     EISSN: 15732614     Source Type: Journal    
DOI: 10.1007/s10877-013-9433-x     Document Type: Article
Times cited : (33)

References (37)
  • 1
    • 0002409260 scopus 로고
    • The respiratory dead space measured by single breath analysis of oxygen, carbon dioxide, nitrogen or helium
    • 13117963 10.1172/JCI102868 1:STN:280:DyaG2c%2FjvV2htw%3D%3D
    • Bartels J, Severinghaus JW, Forster RE, Briscoe WA, Bates DV. The respiratory dead space measured by single breath analysis of oxygen, carbon dioxide, nitrogen or helium. J Clin Invest. 1954;33:41-8.
    • (1954) J Clin Invest , vol.33 , pp. 41-48
    • Bartels, J.1    Severinghaus, J.W.2    Forster, R.E.3    Briscoe, W.A.4    Bates, D.V.5
  • 2
    • 0019350807 scopus 로고
    • The concept of deadspace with special reference to the single breath test for carbon dioxide
    • 6779846 10.1093/bja/53.1.77 1:STN:280:DyaL3M7htVajug%3D%3D
    • Fletcher R, Jonson B. The concept of deadspace with special reference to the single breath test for carbon dioxide. Br J Anaesth. 1981;53:77-88.
    • (1981) Br J Anaesth , vol.53 , pp. 77-88
    • Fletcher, R.1    Jonson, B.2
  • 4
    • 84972105555 scopus 로고
    • Über die Lungeatmung
    • 10.1111/j.1748-1716.1891.tb00581.x
    • Bohr C. Über die Lungeatmung. Skand Arch Physiol. 1891;2:236-8.
    • (1891) Skand Arch Physiol , vol.2 , pp. 236-238
    • Bohr, C.1
  • 5
    • 84859102668 scopus 로고    scopus 로고
    • Rationale of dead space measurement by volumetric capnography
    • 22383673 10.1213/ANE.0b013e318247f6cc
    • Tusman G, Suarez Sipmann F, Bohm SH. Rationale of dead space measurement by volumetric capnography. Anesth Analg. 2012;114:866-74.
    • (2012) Anesth Analg , vol.114 , pp. 866-874
    • Tusman, G.1    Suarez Sipmann, F.2    Bohm, S.H.3
  • 6
    • 79954608305 scopus 로고    scopus 로고
    • Capnography reflects ventilation/perfusion distribution in a model of acute lung injury
    • 21342153 10.1111/j.1399-6576.2011.02404.x 1:STN:280: DC%2BC3MfkvFCqtg%3D%3D
    • Tusman G, Suarez Sipmann F, Bohm SH, Borges JB, Hedenstierna G. Capnography reflects ventilation/perfusion distribution in a model of acute lung injury. Acta Anaesthesiol Scand. 2011;55:597-606.
    • (2011) Acta Anaesthesiol Scand , vol.55 , pp. 597-606
    • Tusman, G.1    Suarez Sipmann, F.2    Bohm, S.H.3    Borges, J.B.4    Hedenstierna, G.5
  • 8
    • 0000359459 scopus 로고
    • Volumen inefficax. Bemerkungen zur Frage des schädlichen Raumes
    • Enghoff H. Volumen inefficax. Bemerkungen zur Frage des schädlichen Raumes. Uppsala Läkareforen Forhandl. 1938;44:191-218.
    • (1938) Uppsala Läkareforen Forhandl , vol.44 , pp. 191-218
    • Enghoff, H.1
  • 9
    • 0022034694 scopus 로고
    • Deadspace, invasive and non-invasive
    • 3919744 10.1093/bja/57.3.245 1:STN:280:DyaL2M7kvFygtA%3D%3D
    • Fletcher R. Deadspace, invasive and non-invasive. Br J Anaesth. 1985;57:245-9.
    • (1985) Br J Anaesth , vol.57 , pp. 245-249
    • Fletcher, R.1
  • 10
    • 52449110337 scopus 로고    scopus 로고
    • Causes of high physiological dead space in critically ill patients
    • 18492224 10.1186/cc6888
    • Wagner P. Causes of high physiological dead space in critically ill patients. Crit Care. 2008;12:148-9.
    • (2008) Crit Care , vol.12 , pp. 148-149
    • Wagner, P.1
  • 12
    • 34447103117 scopus 로고    scopus 로고
    • Systematic errors and susceptibility to noise of four methods for calculating anatomical dead space from the CO2 expirogram
    • 17470845 10.1093/bja/aem090 1:STN:280:DC%2BD2szgs1Ontw%3D%3D
    • Tang Y, Turner MJ, Baker AB. Systematic errors and susceptibility to noise of four methods for calculating anatomical dead space from the CO2 expirogram. Br J Anaesth. 2007;98:828-34.
    • (2007) Br J Anaesth , vol.98 , pp. 828-834
    • Tang, Y.1    Turner, M.J.2    Baker, A.B.3
  • 13
    • 68349128654 scopus 로고    scopus 로고
    • Model fitting of volumetric capnograms improves calculations of airway dead space and slope of phase III
    • 10.1007/s10877-009-9182-z
    • Tusman G, Scandurra A, Bohm SH, Suarez Sipmann F, Clara F. Model fitting of volumetric capnograms improves calculations of airway dead space and slope of phase III. J Clin Monitor Computing. 2009;23:197-206.
    • (2009) J Clin Monitor Computing , vol.23 , pp. 197-206
    • Tusman, G.1    Scandurra, A.2    Bohm, S.H.3    Suarez Sipmann, F.4    Clara, F.5
  • 15
    • 0023832551 scopus 로고
    • Numerical and experimental study of steady-state CO2 and inert gas washout
    • 3130367 10.1063/1.341911 1:STN:280:DyaL1c3htlajug%3D%3D
    • Scherer PW, Gobran SJ, Baumgardner JE, Bartkowski R, Neufeld GR. Numerical and experimental study of steady-state CO2 and inert gas washout. J Appl Physiol. 1988;64:1022-9.
    • (1988) J Appl Physiol , vol.64 , pp. 1022-1029
    • Scherer, P.W.1    Gobran, S.J.2    Baumgardner, J.E.3    Bartkowski, R.4    Neufeld, G.R.5
  • 16
    • 22144484195 scopus 로고    scopus 로고
    • Accuracy of physiological dead space measurements in patients with ARDS using volumetric capnography: Comparison with the metabolic monitor method
    • 15807908
    • Kallet RH, Daniel BM, Garcia O, Matthay MA. Accuracy of physiological dead space measurements in patients with ARDS using volumetric capnography: comparison with the metabolic monitor method. Respir Care. 2005;50:462-7.
    • (2005) Respir Care , vol.50 , pp. 462-467
    • Kallet, R.H.1    Daniel, B.M.2    Garcia, O.3    Matthay, M.A.4
  • 17
    • 84861904513 scopus 로고
    • Lung function studies II. The respiratory dead space
    • 18101134 1:STN:280:DyaH1M%2Fgt1Ogsg%3D%3D
    • Fowler WS. Lung function studies II. The respiratory dead space. Am J Physiol. 1948;154:405-16.
    • (1948) Am J Physiol , vol.154 , pp. 405-416
    • Fowler, W.S.1
  • 18
    • 0015623550 scopus 로고
    • Cyclical variations in FRC and other respiratory variables in resting man
    • 4703744 1:STN:280:DyaE3s7nsFequw%3D%3D
    • Hlastala MP, Wranne B, Lenfant CJ. Cyclical variations in FRC and other respiratory variables in resting man. J Appl Physiol. 1973;34:670-6.
    • (1973) J Appl Physiol , vol.34 , pp. 670-676
    • Hlastala, M.P.1    Wranne, B.2    Lenfant, C.J.3
  • 19
    • 24044492606 scopus 로고    scopus 로고
    • Volumetric capnography: Reliability and reproducibility in spontaneously breathing patients
    • 16117730 10.1111/j.1475-097X.2005.00620.x
    • Verschuren F, Heinonen E, Clause D, Zech F, Reynaert MS, Liistro G. Volumetric capnography: reliability and reproducibility in spontaneously breathing patients. Clin Physiol Funct Imaging. 2005;25:275-80.
    • (2005) Clin Physiol Funct Imaging , vol.25 , pp. 275-280
    • Verschuren, F.1    Heinonen, E.2    Clause, D.3    Zech, F.4    Reynaert, M.S.5    Liistro, G.6
  • 20
    • 0034438773 scopus 로고    scopus 로고
    • Non-steady state monitoring by respiratory gas exchange
    • 10.1023/A:1011447500984 1:STN:280:DC%2BD3s%2FmvFylsg%3D%3D
    • Breen PH, Isserles SA, Taitelman UZ. Non-steady state monitoring by respiratory gas exchange. J Clin Monit. 2000;16:351-60.
    • (2000) J Clin Monit , vol.16 , pp. 351-360
    • Breen, P.H.1    Isserles, S.A.2    Taitelman, U.Z.3
  • 21
    • 0021987676 scopus 로고
    • Functional Residual Capacity, Thoracoabdominal Dimensions, and Central Blood Volume during General Anesthesia with Muscle Paralysis and Mechanical Ventilation
    • 3977112 10.1097/00000542-198503000-00007 1:CAS:528:DyaL2MXhs1Sgt7w%3D
    • Hedenstierna G, Strandberg Å, Brismar B, Lundquist H, Svensson L, Tokics L. Functional Residual Capacity, Thoracoabdominal Dimensions, and Central Blood Volume during General Anesthesia with Muscle Paralysis and Mechanical Ventilation. Anesthesiology. 1985;62:247-54.
    • (1985) Anesthesiology , vol.62 , pp. 247-254
    • Hedenstierna, G.1    Strandberg, Å.2    Brismar, B.3    Lundquist, H.4    Svensson, L.5    Tokics, L.6
  • 22
    • 0028832980 scopus 로고
    • Ventilation-perfusion relationships during anaesthesia
    • 7886658 10.1136/thx.50.1.85 1:STN:280:DyaK2M7pt12htg%3D%3D
    • Hedenstierna G. Ventilation-perfusion relationships during anaesthesia. Thorax. 1995;50:85-91.
    • (1995) Thorax , vol.50 , pp. 85-91
    • Hedenstierna, G.1
  • 23
    • 0021928256 scopus 로고
    • Pulmonary densities during anaesthesia with muscular relaxation - A proposal of atelectasis
    • 3885791 10.1097/00000542-198504000-00009 1:STN:280:DyaL2M7nt1KqsA%3D%3D
    • Brismar B, Hedenstierna G, Lundquist H, Strandberg Å, Svensson L, Tokics L. Pulmonary densities during anaesthesia with muscular relaxation - A proposal of atelectasis. Anesthesiology. 1985;62:422-8.
    • (1985) Anesthesiology , vol.62 , pp. 422-428
    • Brismar, B.1    Hedenstierna, G.2    Lundquist, H.3    Strandberg, Å.4    Svensson, L.5    Tokics, L.6
  • 24
    • 33846307424 scopus 로고    scopus 로고
    • Tidal hyperinflation during low tidal volume ventilation in acute respiratory distress syndrome
    • 17038660 10.1164/rccm.200607-915OC 1:CAS:528:DC%2BD2sXitVansb8%3D
    • Terragni PP, Rosboch G, Tealdi A, Corno E, Menaldo E, Davini O. Tidal hyperinflation during low tidal volume ventilation in acute respiratory distress syndrome. Am J Respir Crit Care Med. 2007;175:160-6.
    • (2007) Am J Respir Crit Care Med , vol.175 , pp. 160-166
    • Terragni, P.P.1    Rosboch, G.2    Tealdi, A.3    Corno, E.4    Menaldo, E.5    Davini, O.6
  • 25
    • 0013970040 scopus 로고
    • The expiratory capnogram: A measure of ventilation-perfusion inequalities
    • 10.1136/thx.21.6.518
    • Hofbrand BI. The expiratory capnogram: a measure of ventilation-perfusion inequalities. Thorax. 1966;21:518-24.
    • (1966) Thorax , vol.21 , pp. 518-524
    • Hofbrand, B.I.1
  • 26
    • 0033038768 scopus 로고    scopus 로고
    • Relationship between expired capnogram and respiratory system resistance in critically ill patients during total ventilatory support
    • 10414403 10.1034/j.1399-3003.1999.13e19.x 1:STN:280:DyaK1MzktFemsQ%3D%3D
    • Blanch LL, Fernandez R, Saura P, Baigorri F, Artigas A. Relationship between expired capnogram and respiratory system resistance in critically ill patients during total ventilatory support. Eur Respir J. 1999;13:1048-54.
    • (1999) Eur Respir J , vol.13 , pp. 1048-1054
    • Blanch, L.L.1    Fernandez, R.2    Saura, P.3    Baigorri, F.4    Artigas, A.5
  • 28
    • 34547807610 scopus 로고    scopus 로고
    • Ventilation heterogeneity is a major determinant of airway hyperresponsiveness in asthma, independent of airway inflammation
    • 17311839 10.1136/thx.2006.069682
    • Downie SR, Salome CM, Verbank S, Thompson B, Berend N, King GG. Ventilation heterogeneity is a major determinant of airway hyperresponsiveness in asthma, independent of airway inflammation. Thorax. 2007;62:684-9.
    • (2007) Thorax , vol.62 , pp. 684-689
    • Downie, S.R.1    Salome, C.M.2    Verbank, S.3    Thompson, B.4    Berend, N.5    King, G.G.6
  • 29
    • 7044274362 scopus 로고    scopus 로고
    • Alveolar recruitment improves ventilatory efficiency of the lungs during anesthesia
    • 15310643 10.1007/BF03018433
    • Tusman G, Böhm SH, Suárez Sipmann F, Turchetto E. Alveolar recruitment improves ventilatory efficiency of the lungs during anesthesia. Can J Anesth. 2004;51:723-7.
    • (2004) Can J Anesth , vol.51 , pp. 723-727
    • Tusman, G.1    Böhm, S.H.2    Suárez Sipmann, F.3    Turchetto, E.4
  • 30
    • 0033772788 scopus 로고    scopus 로고
    • Partitioning of dead space - A method and reference values in the awake human
    • 11106209 10.1034/j.1399-3003.2000.16d16.x
    • Åström E, Niklason L, Drefeldt B, Bajc M, Jonson B. Partitioning of dead space - a method and reference values in the awake human. Eur Respir J. 2000;16:659-64.
    • (2000) Eur Respir J , vol.16 , pp. 659-664
    • Åström, E.1    Niklason, L.2    Drefeldt, B.3    Bajc, M.4    Jonson, B.5
  • 31
    • 0021366124 scopus 로고
    • Deadspace and the single breath test for carbon dioxide during anaesthesia and artificial ventilation. Effects of tidal volume and frequency of respiration
    • 6419753 10.1093/bja/56.2.109 1:STN:280:DyaL2c7gsVGhsg%3D%3D
    • Fletcher R, Jonson B. Deadspace and the single breath test for carbon dioxide during anaesthesia and artificial ventilation. Effects of tidal volume and frequency of respiration. Br J Anaesth. 1984;56:109-19.
    • (1984) Br J Anaesth , vol.56 , pp. 109-119
    • Fletcher, R.1    Jonson, B.2
  • 34
    • 0001118039 scopus 로고
    • Alveolar deadspace as an index of distribution of blood flow in pulmonary capillaries
    • Severinhaus JW, Stupfel M. Alveolar deadspace as an index of distribution of blood flow in pulmonary capillaries. J Appl Physiol. 1957;10:335-48.
    • (1957) J Appl Physiol , vol.10 , pp. 335-348
    • Severinhaus, J.W.1    Stupfel, M.2
  • 35
    • 0028339207 scopus 로고
    • Pulmonary dead space and airway dimensions in dogs at different levels of lung inflation
    • 8063647 1:STN:280:DyaK2czkt1Wlug%3D%3D
    • Schulz A, Schlz H, Heilmann P, Brand P, Heyder J. Pulmonary dead space and airway dimensions in dogs at different levels of lung inflation. J Appl Physiol. 1994;76:1896-902.
    • (1994) J Appl Physiol , vol.76 , pp. 1896-1902
    • Schulz, A.1    Schlz, H.2    Heilmann, P.3    Brand, P.4    Heyder, J.5
  • 36
    • 0016829884 scopus 로고
    • The effect of anaesthesia and intermittent positive pressure ventilation with different frequencies on the anatomical and alveolar deadspace
    • 1103915 10.1093/bja/47.8.847 1:STN:280:DyaE28%2FmtF2isw%3D%3D
    • Hedenstierna G, McCarthy G. The effect of anaesthesia and intermittent positive pressure ventilation with different frequencies on the anatomical and alveolar deadspace. Br J Anaesth. 1975;47:847-52.
    • (1975) Br J Anaesth , vol.47 , pp. 847-852
    • Hedenstierna, G.1    McCarthy, G.2
  • 37
    • 72849165961 scopus 로고
    • Respiratory dead space and arterial to end-tidal CO2 difference in anesthetized man
    • 14427915 1:STN:280:DyaF3c7otVKhsw%3D%3D
    • Nunn JF, Hill DW. Respiratory dead space and arterial to end-tidal CO2 difference in anesthetized man. J Appl Physiol. 1960;15:383-9.
    • (1960) J Appl Physiol , vol.15 , pp. 383-389
    • Nunn, J.F.1    Hill, D.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.