메뉴 건너뛰기




Volumn 85, Issue 10, 2013, Pages 4944-4950

Catch and release: Integrated system for multiplexed detection of bacteria

Author keywords

[No Author keywords available]

Indexed keywords

DOSE-RESPONSE CURVES; IMMUNOMAGNETIC SEPARATION; INTEGRATED SYSTEMS; LIMITS OF DETECTION; MICROFLOW CYTOMETER; MULTIPLEXED DETECTION; OPTICAL DETECTION; OPTICAL INTERROGATION;

EID: 84878313437     PISSN: 00032700     EISSN: 15206882     Source Type: Journal    
DOI: 10.1021/ac303801v     Document Type: Article
Times cited : (35)

References (34)
  • 1
    • 33747086959 scopus 로고    scopus 로고
    • Microfluidic diagnostic technologies for global public health
    • Yager, P.; Edwards, T.; Fu, E.; Helton, K.; Nelson, K.; Tam, M. R.; Weigl, B. H. Microfluidic diagnostic technologies for global public health Nature 2006, 442 (7101) 412-418
    • (2006) Nature , vol.442 , Issue.7101 , pp. 412-418
    • Yager, P.1    Edwards, T.2    Fu, E.3    Helton, K.4    Nelson, K.5    Tam, M.R.6    Weigl, B.H.7
  • 2
    • 33745726976 scopus 로고    scopus 로고
    • Monitoring and telemedicine support in remote environments and in human space flight
    • Cermack, M. Monitoring and telemedicine support in remote environments and in human space flight Br. J. Anaesth. 2006, 97 (1) 107-114
    • (2006) Br. J. Anaesth. , vol.97 , Issue.1 , pp. 107-114
    • Cermack, M.1
  • 3
    • 34547756976 scopus 로고    scopus 로고
    • Biomimetic sensors for toxic pesticides and inorganics based on Optoelectronic/Electrochemical transducers - An overview
    • Rao, T. P.; Prasad, K.; Kala, R.; Gladis, J. M. Biomimetic sensors for toxic pesticides and inorganics based on Optoelectronic/Electrochemical transducers-An overview Crit. Rev. Anal. Chem. 2007, 37 (3) 191-210
    • (2007) Crit. Rev. Anal. Chem. , vol.37 , Issue.3 , pp. 191-210
    • Rao, T.P.1    Prasad, K.2    Kala, R.3    Gladis, J.M.4
  • 4
    • 63849184210 scopus 로고    scopus 로고
    • Toxin Detection by Surface Plasmon Resonance
    • Hodnik, V.; Anderluh, G. Toxin Detection by Surface Plasmon Resonance Sensors 2009, 9 (3) 1339-1354
    • (2009) Sensors , vol.9 , Issue.3 , pp. 1339-1354
    • Hodnik, V.1    Anderluh, G.2
  • 5
    • 79959834074 scopus 로고    scopus 로고
    • Microfluidics-Based Lab-on-Chip Systems in DNA-Based Biosensing: An Overview
    • Dutse, S. W.; Yusof, N. A. Microfluidics-Based Lab-on-Chip Systems in DNA-Based Biosensing: An Overview Sensors 2011, 11 (6) 5754-5768
    • (2011) Sensors , vol.11 , Issue.6 , pp. 5754-5768
    • Dutse, S.W.1    Yusof, N.A.2
  • 6
    • 33644874614 scopus 로고    scopus 로고
    • Protein biochip systems for the clinical laboratory
    • Dupuy, A. M.; Lehmann, S.; Cristol, J. P. Protein biochip systems for the clinical laboratory Clin. Chem. Lab. Med. 2005, 43 (12) 1291-1302
    • (2005) Clin. Chem. Lab. Med. , vol.43 , Issue.12 , pp. 1291-1302
    • Dupuy, A.M.1    Lehmann, S.2    Cristol, J.P.3
  • 9
    • 84866981245 scopus 로고    scopus 로고
    • Recent advances in paper-based sensors
    • Liana, D. D.; Raguse, B.; Gooding, J. J.; Chow, E. Recent advances in paper-based sensors Sensors 2012, 12 (9) 11505-11526
    • (2012) Sensors , vol.12 , Issue.9 , pp. 11505-11526
    • Liana, D.D.1    Raguse, B.2    Gooding, J.J.3    Chow, E.4
  • 13
    • 0029989857 scopus 로고    scopus 로고
    • Functional Integration of PCR Amplification and Capillary Electrophoresis in a Microfabricated DNA Analysis Device
    • Woolley, A. T.; Hadley, D.; Landre, P.; deMello, A. J.; Mathies, R. A.; Northrup, M. A. Functional Integration of PCR Amplification and Capillary Electrophoresis in a Microfabricated DNA Analysis Device Anal. Chem. 1996, 68 (23) 4081-4086
    • (1996) Anal. Chem. , vol.68 , Issue.23 , pp. 4081-4086
    • Woolley, A.T.1    Hadley, D.2    Landre, P.3    Demello, A.J.4    Mathies, R.A.5    Northrup, M.A.6
  • 14
    • 33746798062 scopus 로고    scopus 로고
    • Multichannel PCR-CE microdevice for genetic analysis
    • Liu, C. N.; Toriello, N. M.; Mathies, R. A. Multichannel PCR-CE microdevice for genetic analysis Anal. Chem. 2006, 78 (15) 5474-9
    • (2006) Anal. Chem. , vol.78 , Issue.15 , pp. 5474-5479
    • Liu, C.N.1    Toriello, N.M.2    Mathies, R.A.3
  • 15
    • 41449108885 scopus 로고    scopus 로고
    • Identification of respiratory pathogen Bordetella Pertussis using integrated microfluidic chip technology
    • Prakash, A. R.; Rosa, C.; Fox, J.; Kaler, K. I. S. Identification of respiratory pathogen Bordetella Pertussis using integrated microfluidic chip technology Microfluid. Nanofluid. 2008, 4 (5) 451-456
    • (2008) Microfluid. Nanofluid. , vol.4 , Issue.5 , pp. 451-456
    • Prakash, A.R.1    Rosa, C.2    Fox, J.3    Kaler, K.I.S.4
  • 16
    • 33747086959 scopus 로고    scopus 로고
    • Microfluidic diagnostic technologies for global public health
    • Yager, P.; Edwards, T.; Fu, E.; Helton, K.; Nelson, K.; Tam, M. R.; Weigl, B. H. Microfluidic diagnostic technologies for global public health Nature 2006, 442 (7101) 412-8
    • (2006) Nature , vol.442 , Issue.7101 , pp. 412-418
    • Yager, P.1    Edwards, T.2    Fu, E.3    Helton, K.4    Nelson, K.5    Tam, M.R.6    Weigl, B.H.7
  • 18
    • 11144303020 scopus 로고    scopus 로고
    • Microfluidic system integration in sample preparation chip-sets - A summary
    • Grodzinski, P.; Liu, R.; Yang, J.; Ward, M. D. Microfluidic system integration in sample preparation chip-sets-a summary Proc. Annu. Int. IEEE EMBS 2004, 26, 2615-2618
    • (2004) Proc. Annu. Int. IEEE EMBS , vol.26 , pp. 2615-2618
    • Grodzinski, P.1    Liu, R.2    Yang, J.3    Ward, M.D.4
  • 19
    • 33845910922 scopus 로고    scopus 로고
    • Lab-on-A-chip devices for global health: Past studies and future opportunities
    • Chin, C. D.; Linder, V.; Sia, S. K. Lab-on-a-chip devices for global health: past studies and future opportunities Lab Chip 2007, 7 (1) 41-57
    • (2007) Lab Chip , vol.7 , Issue.1 , pp. 41-57
    • Chin, C.D.1    Linder, V.2    Sia, S.K.3
  • 20
    • 79957473583 scopus 로고    scopus 로고
    • Fish-on-A-chip: A sensitive detection microfluidic system for Alzheimer's disease
    • Devadhasan, J. P.; Kim, S.; An, J. Fish-on-a-chip: a sensitive detection microfluidic system for Alzheimer's disease J. Biomed. Sci. 2011, 18, 33
    • (2011) J. Biomed. Sci. , vol.18 , pp. 33
    • Devadhasan, J.P.1    Kim, S.2    An, J.3
  • 21
    • 23644448617 scopus 로고    scopus 로고
    • Development of a microfluidic biosensor module for pathogen detection
    • Zaytseva, N. V.; Goral, V. N.; Montagna, R. A.; Baeumner, A. J. Development of a microfluidic biosensor module for pathogen detection Lab Chip 2005, 5 (8) 805-811
    • (2005) Lab Chip , vol.5 , Issue.8 , pp. 805-811
    • Zaytseva, N.V.1    Goral, V.N.2    Montagna, R.A.3    Baeumner, A.J.4
  • 24
    • 66149119779 scopus 로고    scopus 로고
    • Integrated capture, concentration, polymerase chain reaction, and capillary electrophoretic analysis of pathogens on a chip
    • Beyor, N.; Yi, L.; Seo, T. S.; Mathies, R. A. Integrated capture, concentration, polymerase chain reaction, and capillary electrophoretic analysis of pathogens on a chip Anal. Chem. 2009, 81 (9) 3523-3528
    • (2009) Anal. Chem. , vol.81 , Issue.9 , pp. 3523-3528
    • Beyor, N.1    Yi, L.2    Seo, T.S.3    Mathies, R.A.4
  • 25
    • 80053542204 scopus 로고    scopus 로고
    • Committee on Effectiveness of National Biosurveillance Systems: BioWatch and the Public Health System, N. R. C. The National Academies Press: Washington, DC.
    • Committee on Effectiveness of National Biosurveillance Systems: BioWatch and the Public Health System, N. R. C. BioWatch and Public Health Surveillance: Evaluating Systems for the Early Detection of Biological Threats; The National Academies Press: Washington, DC, 2011.
    • (2011) BioWatch and Public Health Surveillance: Evaluating Systems for the Early Detection of Biological Threats
  • 27
    • 67650751073 scopus 로고    scopus 로고
    • Rapid multiplexed flow cytometric assay for botulinum neurotoxin detection using an automated fluidic microbead-trapping flow cell for enhanced sensitivity
    • Ozanich, R. M., Jr.; Bruckner-Lea, C. J.; Warner, M. G.; Miller, K.; Antolick, K. C.; Marks, J. D.; Lou, J.; Grate, J. W. Rapid multiplexed flow cytometric assay for botulinum neurotoxin detection using an automated fluidic microbead-trapping flow cell for enhanced sensitivity Anal. Chem. 2009, 81 (14) 5783-5793
    • (2009) Anal. Chem. , vol.81 , Issue.14 , pp. 5783-5793
    • Ozanich Jr., R.M.1    Bruckner-Lea, C.J.2    Warner, M.G.3    Miller, K.4    Antolick, K.C.5    Marks, J.D.6    Lou, J.7    Grate, J.W.8
  • 30
    • 84868638780 scopus 로고    scopus 로고
    • Automated processing integrated with a microflow cytometer for pathogen detection in clinical matrices
    • Golden, J. P.; Verbarg, J.; Howell, P. B.; Shriver-Lake, L. C.; Ligler, F. S. Automated processing integrated with a microflow cytometer for pathogen detection in clinical matrices Biosens. Bioelectron. 2013, 40, 10-16
    • (2013) Biosens. Bioelectron. , vol.40 , pp. 10-16
    • Golden, J.P.1    Verbarg, J.2    Howell, P.B.3    Shriver-Lake, L.C.4    Ligler, F.S.5
  • 32
    • 67649997689 scopus 로고    scopus 로고
    • Multiplexed Detection of Bacteria and Toxins Using a Microflow Cytometer
    • Kim, J. S.; Anderson, G. P.; Erickson, J. S.; Golden, J. P.; Nasir, M.; Ligler, F. S. Multiplexed Detection of Bacteria and Toxins Using a Microflow Cytometer Anal. Chem. 2009, 81 (13) 5426-5432
    • (2009) Anal. Chem. , vol.81 , Issue.13 , pp. 5426-5432
    • Kim, J.S.1    Anderson, G.P.2    Erickson, J.S.3    Golden, J.P.4    Nasir, M.5    Ligler, F.S.6
  • 33
    • 79959776548 scopus 로고    scopus 로고
    • Surface Modification and Biomolecule Immobilization on Polymer Spheres for Biosensing Applications
    • In; Hurst, S. J. Humana Press: New York, Vol.
    • Taitt, C. R.; Shriver-Lake, L. C.; Anderson, G. P.; Ligler, F. S. Surface Modification and Biomolecule Immobilization on Polymer Spheres for Biosensing Applications. In Biomedical Nanotechnology; Hurst, S. J., Ed.; Humana Press: New York, 2011; Vol. 726, pp 77-94.
    • (2011) Biomedical Nanotechnology , vol.726 , pp. 77-94
    • Taitt, C.R.1    Shriver-Lake, L.C.2    Anderson, G.P.3    Ligler, F.S.4