메뉴 건너뛰기




Volumn 43, Issue 6, 2013, Pages 1233-1236

Implantation of rotary blood pumps into 115 patients: A single-centre experience

Author keywords

Heartmate II; Heartware; Left ventricular assist device; Outcome

Indexed keywords

ADULT; ARTICLE; BLOOD PUMP; CARDIAC IMPLANT; CARDIOVASCULAR MORTALITY; CENTRIFUGAL PUMP; CONTROLLED STUDY; EXTRACORPOREAL OXYGENATION; FEMALE; FOLLOW UP; HEART FAILURE; HEART GRAFT; HOSPITAL DISCHARGE; HOSPITALIZATION; HUMAN; INOTROPISM; ISCHEMIC CARDIOMYOPATHY; LEFT VENTRICULAR ASSIST DEVICE; MAJOR CLINICAL STUDY; MALE; NONISCHEMIC CARDIOMYOPATHY; PRIORITY JOURNAL; SURGICAL MORTALITY;

EID: 84878191263     PISSN: 10107940     EISSN: 1873734X     Source Type: Journal    
DOI: 10.1093/ejcts/ezs568     Document Type: Article
Times cited : (12)

References (16)
  • 3
    • 49549110298 scopus 로고    scopus 로고
    • Right heart dysfunction after left ventricular assist device implantation: a comparison of the pulsatile HeartMate I and axial-flow HeartMate II devices
    • discussion 832-40
    • Patel ND, Weiss ES, Schaffer J, Ullrich SL, Rivard DC, Shah AS et al. Right heart dysfunction after left ventricular assist device implantation: a comparison of the pulsatile HeartMate I and axial-flow HeartMate II devices. Ann Thorac Surg 2008;86:832-40. discussion 832-40.
    • (2008) Ann Thorac Surg , vol.86 , pp. 832-840
    • Patel, N.D.1    Weiss, E.S.2    Schaffer, J.3    Ullrich, S.L.4    Rivard, D.C.5    Shah, A.S.6
  • 4
    • 62649146948 scopus 로고    scopus 로고
    • Renal function and outcome after continuous flow left ventricular assist device implantation
    • Sandner SE, Zimpfer D, Zrunek P, Rajek A, Schima H, Dunkler D et al. Renal function and outcome after continuous flow left ventricular assist device implantation. Ann Thorac Surg 2009;87:1072-8.
    • (2009) Ann Thorac Surg , vol.87 , pp. 1072-1078
    • Sandner, S.E.1    Zimpfer, D.2    Zrunek, P.3    Rajek, A.4    Schima, H.5    Dunkler, D.6
  • 5
    • 34748926436 scopus 로고    scopus 로고
    • Hemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices
    • Haft J, Armstrong W, Dyke DB, Aaronson KD, Koelling TM, Farrar DJ et al. Hemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices. Circulation 2007;116(11 Suppl):I8-15.
    • (2007) Circulation , vol.116 , Issue.11 SUPPL.
    • Haft, J.1    Armstrong, W.2    Dyke, D.B.3    Aaronson, K.D.4    Koelling, T.M.5    Farrar, D.J.6
  • 7
    • 78049287188 scopus 로고    scopus 로고
    • HVAD Clinical Investigators Initial clinical experience with a novel left ventricular assist device with a magnetically levitated rotor in a multi-institutional trial
    • Wieselthaler GM, O'Driscoll G, Jansz P, Khaghani A, Strueber M; HVAD Clinical Investigators. Initial clinical experience with a novel left ventricular assist device with a magnetically levitated rotor in a multi-institutional trial. J Heart Lung Transplant 2010;29:1218-25.
    • (2010) J Heart Lung Transplant , vol.29 , pp. 1218-1225
    • Wieselthaler, G.M.1    O'Driscoll, G.2    Jansz, P.3    Khaghani, A.4    Strueber, M.5
  • 8
    • 84855359650 scopus 로고    scopus 로고
    • Preoperative treatment with levosimendan in candidates for mechanical circulatory support
    • Sponga S, Ivanitskaia E, Potapov E, Krabatsch T, Hetzer R, Lehmkuhl H. Preoperative treatment with levosimendan in candidates for mechanical circulatory support. ASAIO J 2012;58:6-11.
    • (2012) ASAIO J , vol.58 , pp. 6-11
    • Sponga, S.1    Ivanitskaia, E.2    Potapov, E.3    Krabatsch, T.4    Hetzer, R.5    Lehmkuhl, H.6
  • 9
    • 34548297997 scopus 로고    scopus 로고
    • Outcomes of left ventricular assist device implantation as destination therapy in the post-REMATCH era: implications for patient selection
    • Lietz K, Long JW, Kfoury AG, Slaughter MS, Silver MA, Milano CA et al. Outcomes of left ventricular assist device implantation as destination therapy in the post-REMATCH era: implications for patient selection. Circulation 2007;116:497-505.
    • (2007) Circulation , vol.116 , pp. 497-505
    • Lietz, K.1    Long, J.W.2    Kfoury, A.G.3    Slaughter, M.S.4    Silver, M.A.5    Milano, C.A.6
  • 10
    • 78650962548 scopus 로고    scopus 로고
    • Results of HeartMate II left ventricular assist device implantation on renal function in patients requiring post-implant renal replacement therapy
    • Demirozu ZT, Etheridge WB, Radovancevic R, Frazier OH. Results of HeartMate II left ventricular assist device implantation on renal function in patients requiring post-implant renal replacement therapy. J Heart Lung Transplant 2011;30:182-7.
    • (2011) J Heart Lung Transplant , vol.30 , pp. 182-187
    • Demirozu, Z.T.1    Etheridge, W.B.2    Radovancevic, R.3    Frazier, O.H.4
  • 11
    • 84865691860 scopus 로고    scopus 로고
    • Long-term mechanical circulatory support (destination therapy): on track to compete with heart transplantation?
    • Kirklin JK, Naftel DC, Pagani FD, Kormos RL, Stevenson L, Miller M et al. Long-term mechanical circulatory support (destination therapy): on track to compete with heart transplantation? J Thorac Cardiovasc Surg 2012; 144:584-603.
    • (2012) J Thorac Cardiovasc Surg , vol.144 , pp. 584-603
    • Kirklin, J.K.1    Naftel, D.C.2    Pagani, F.D.3    Kormos, R.L.4    Stevenson, L.5    Miller, M.6
  • 12
    • 84857611468 scopus 로고    scopus 로고
    • Clinical experience with HeartWare left ventricular assist device in patients with end-stage heart failure
    • Popov AF, Hosseini MT, Zych B, Mohite P, Hards R, Krueger H et al. Clinical experience with HeartWare left ventricular assist device in patients with end-stage heart failure. Ann Thorac Surg 2012;93:810-5.
    • (2012) Ann Thorac Surg , vol.93 , pp. 810-815
    • Popov, A.F.1    Hosseini, M.T.2    Zych, B.3    Mohite, P.4    Hards, R.5    Krueger, H.6
  • 14
    • 84863195802 scopus 로고    scopus 로고
    • Use of an intrapericardial, continuous-flow, centrifugal pump in patients awaiting heart transplantation
    • Aaronson KD, Slaughter MS, Miller LW, McGee EC, Cotts WG, Acker MA et al. Use of an intrapericardial, continuous-flow, centrifugal pump in patients awaiting heart transplantation. Circulation 2012;125: 3191-200.
    • (2012) Circulation , vol.125 , pp. 3191-3200
    • Aaronson, K.D.1    Slaughter, M.S.2    Miller, L.W.3    McGee, E.C.4    Cotts, W.G.5    Acker, M.A.6
  • 15
    • 78650155308 scopus 로고    scopus 로고
    • Acquired von Willebrand syndrome in patients with an axial flow left ventricular assist device
    • Meyer AL, Malehsa D, Bara C, Budde U, Slaughter MS, Haverich A et al. Acquired von Willebrand syndrome in patients with an axial flow left ventricular assist device. Circ Heart Fail 2010;3:675-81.
    • (2010) Circ Heart Fail , vol.3 , pp. 675-681
    • Meyer, A.L.1    Malehsa, D.2    Bara, C.3    Budde, U.4    Slaughter, M.S.5    Haverich, A.6
  • 16
    • 77952583879 scopus 로고    scopus 로고
    • Post-operative heparin may not be required for transitioning patients with a HeartMate II left ventricular assist system to long-term warfarin therapy
    • Slaughter MS, Naka Y, John R, Boyle A, Conte JV, Russell SD et al. Post-operative heparin may not be required for transitioning patients with a HeartMate II left ventricular assist system to long-term warfarin therapy. J Heart Lung Transplant 2010;29:616-24.
    • (2010) J Heart Lung Transplant , vol.29 , pp. 616-624
    • Slaughter, M.S.1    Naka, Y.2    John, R.3    Boyle, A.4    Conte, J.V.5    Russell, S.D.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.