메뉴 건너뛰기




Volumn 27, Issue 12, 2013, Pages 1329-1334

Continuous-flow liquid microjunction surface sampling probe connected on-line with high-performance liquid chromatography/mass spectrometry for spatially resolved analysis of small molecules and proteins

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD; CHROMATOGRAPHIC ANALYSIS; DRUG PRODUCTS; ELECTROSPRAY IONIZATION; EXTRACTION; HIGH PERFORMANCE LIQUID CHROMATOGRAPHY; ION SOURCES; MASS SPECTROMETRY; MOLECULES; PROBES; TISSUE;

EID: 84878068848     PISSN: 09514198     EISSN: 10970231     Source Type: Journal    
DOI: 10.1002/rcm.6580     Document Type: Article
Times cited : (75)

References (30)
  • 1
    • 0037115677 scopus 로고    scopus 로고
    • Thin-layer chromatography and electrospray mass spectrometry coupled using a surface sampling probe
    • G. J. Van Berkel, A. D. Sanchez, J. M. E. Quirke,. Thin-layer chromatography and electrospray mass spectrometry coupled using a surface sampling probe. Anal. Chem. 2002, 74, 6216.
    • (2002) Anal. Chem. , vol.74 , pp. 6216
    • Van Berkel, G.J.1    Sanchez, A.D.2    Quirke, J.M.E.3
  • 2
    • 3042594616 scopus 로고    scopus 로고
    • An improved thin-layer chromatography/mass spectrometry coupling using a surface sampling probe electrospray ion trap system
    • M. J. Ford, G. J. Van Berkel,. An improved thin-layer chromatography/mass spectrometry coupling using a surface sampling probe electrospray ion trap system. Rapid Commun. Mass Spectrom. 2004, 18, 1303.
    • (2004) Rapid Commun. Mass Spectrom. , vol.18 , pp. 1303
    • Ford, M.J.1    Van Berkel, G.J.2
  • 3
    • 23244463508 scopus 로고    scopus 로고
    • Thin layer chromatography/electrospray ionization triple quadrupole linear ion trap mass spectrometry system: Analysis of rhodamine dyes separated on reversed-phase C8 plates
    • M. J. Ford, V. Kertesz, G. J. Van Berkel,. Thin layer chromatography/electrospray ionization triple quadrupole linear ion trap mass spectrometry system: analysis of rhodamine dyes separated on reversed-phase C8 plates. J. Mass Spectrom. 2005, 40, 866.
    • (2005) J. Mass Spectrom. , vol.40 , pp. 866
    • Ford, M.J.1    Kertesz, V.2    Van Berkel, G.J.3
  • 4
    • 27544480441 scopus 로고    scopus 로고
    • Quantitative thin-layer chromatography/mass spectrometry analysis of caffeine using a surface sampling probe electrospray ionization tandem mass spectrometry system
    • M. J. Ford, M. A. Deibel, B. A. Tomkins, G. J. Van Berkel,. Quantitative thin-layer chromatography/mass spectrometry analysis of caffeine using a surface sampling probe electrospray ionization tandem mass spectrometry system. Anal. Chem. 2005, 77, 4385.
    • (2005) Anal. Chem. , vol.77 , pp. 4385
    • Ford, M.J.1    Deibel, M.A.2    Tomkins, B.A.3    Van Berkel, G.J.4
  • 5
    • 33645524387 scopus 로고    scopus 로고
    • Evaluation of a surface sampling probe electrospray mass spectrometry system for the analysis of surface deposited and affinity captured proteins
    • G. J. Van Berkel, M. J. Ford, M. J. Doktycz, S. J. Kennel,. Evaluation of a surface sampling probe electrospray mass spectrometry system for the analysis of surface deposited and affinity captured proteins. Rapid Commun. Mass Spectrom. 2006, 20, 1144.
    • (2006) Rapid Commun. Mass Spectrom. , vol.20 , pp. 1144
    • Van Berkel, G.J.1    Ford, M.J.2    Doktycz, M.J.3    Kennel, S.J.4
  • 6
    • 42049103628 scopus 로고    scopus 로고
    • Liquid micro-junction surface sampling probe electrospray mass spectrometry for detection of drugs and metabolites in thin tissue sections
    • G. J. Van Berkel, V. Kertesz, K. A. Koeplinger, M. Vavrek, A. T. Kong,. Liquid micro-junction surface sampling probe electrospray mass spectrometry for detection of drugs and metabolites in thin tissue sections. J. Mass Spectrom. 2008, 43, 500.
    • (2008) J. Mass Spectrom. , vol.43 , pp. 500
    • Van Berkel, G.J.1    Kertesz, V.2    Koeplinger, K.A.3    Vavrek, M.4    Kong, A.T.5
  • 7
    • 68849103518 scopus 로고    scopus 로고
    • High-throughput mode liquid microjunction surface sampling probe
    • G. J. Van Berkel, V. Kertesz, R. C. King,. High-throughput mode liquid microjunction surface sampling probe. Anal. Chem. 2009, 81, 7096.
    • (2009) Anal. Chem. , vol.81 , pp. 7096
    • Van Berkel, G.J.1    Kertesz, V.2    King, R.C.3
  • 8
    • 77149125967 scopus 로고    scopus 로고
    • Direct analysis of reversed-phase HPTLC separated tryptic protein digests using a liquid microjunction surface sampling probe/ESI-MS system
    • J. F. Emory, M. J. Walworth, G. J. Van Berkel, M. Schulz, S. Minarik,. Direct analysis of reversed-phase HPTLC separated tryptic protein digests using a liquid microjunction surface sampling probe/ESI-MS system. Eur. J. Mass Spectrom. 2009, 16, 21.
    • (2009) Eur. J. Mass Spectrom. , vol.16 , pp. 21
    • Emory, J.F.1    Walworth, M.J.2    Van Berkel, G.J.3    Schulz, M.4    Minarik, S.5
  • 9
    • 79960110209 scopus 로고    scopus 로고
    • Utility of spatially resolved atmospheric pressure surface sampling ionization techniques as alternatives to mass spectrometric imaging (MSI) techniques in drug metabolism
    • E. Q. Blatherwick, G. J. Van Berkel, K. Pickup, M-E. Beaudoin, R. Cole, J. M. Day, M. K. Johannson, S. Iverson, J. H. Scrivens, D. J. Weston,. Utility of spatially resolved atmospheric pressure surface sampling ionization techniques as alternatives to mass spectrometric imaging (MSI) techniques in drug metabolism. Xenobiotica 2011, 41, 720.
    • (2011) Xenobiotica , vol.41 , pp. 720
    • Blatherwick, E.Q.1    Van Berkel, G.J.2    Pickup, K.3    Beaudoin, M.-E.4    Cole, R.5    Day, J.M.6    Johannson, M.K.7    Iverson, S.8    Scrivens, J.H.9    Weston, D.J.10
  • 10
    • 23844554824 scopus 로고    scopus 로고
    • Self-aspirating atmospheric pressure chemical ionization source for direct sampling of analytes on surfaces and in liquid solutions
    • K. G. Asano, M. J. Ford, B. A. Tomkins, G. J. Van Berkel,. Self-aspirating atmospheric pressure chemical ionization source for direct sampling of analytes on surfaces and in liquid solutions. Rapid Commun. Mass Spectrom. 2005, 19, 2305.
    • (2005) Rapid Commun. Mass Spectrom. , vol.19 , pp. 2305
    • Asano, K.G.1    Ford, M.J.2    Tomkins, B.A.3    Van Berkel, G.J.4
  • 11
    • 77955833712 scopus 로고    scopus 로고
    • Nanospray desorption electrospray ionization: An ambient method for liquid-extraction surface sampling in mass spectrometry
    • P. J. Roach, J. Laskin, A. Laskin,. Nanospray desorption electrospray ionization: An ambient method for liquid-extraction surface sampling in mass spectrometry. Analyst 2010, 135, 2233.
    • (2010) Analyst , vol.135 , pp. 2233
    • Roach, P.J.1    Laskin, J.2    Laskin, A.3
  • 13
    • 77954628710 scopus 로고    scopus 로고
    • Liquid microjunction surface sampling coupled with HPLC for analysis of drugs and metabolites in whole-body thin tissue sections
    • V. Kertesz, G. J. Van Berkel,. Liquid microjunction surface sampling coupled with HPLC for analysis of drugs and metabolites in whole-body thin tissue sections. Anal. Chem. 2010, 82, 5917.
    • (2010) Anal. Chem. , vol.82 , pp. 5917
    • Kertesz, V.1    Van Berkel, G.J.2
  • 14
    • 77749237328 scopus 로고    scopus 로고
    • Fully automated liquid extraction-based surface sampling and ionization using a chip-based robotic nanoelectrospray platform
    • V. Kertesz, G. J. Van Berkel,. Fully automated liquid extraction-based surface sampling and ionization using a chip-based robotic nanoelectrospray platform. J. Mass Spectrom. 2010, 45, 252.
    • (2010) J. Mass Spectrom. , vol.45 , pp. 252
    • Kertesz, V.1    Van Berkel, G.J.2
  • 15
    • 85159249095 scopus 로고    scopus 로고
    • http://www.advion.com/products/triversa-nanomate/mode-3-liquid- extraction-surface-analysis-lesa/.
  • 16
    • 79960021220 scopus 로고    scopus 로고
    • Liquid microjunction surface sampling probe fluid dynamics: Computational and experimental analysis of coaxial intercapillary positioning effects on sample manipulation
    • M. S. ElNaggar, C. Barbier, G. J. Van Berkel,. Liquid microjunction surface sampling probe fluid dynamics: Computational and experimental analysis of coaxial intercapillary positioning effects on sample manipulation. J. Am. Soc. Mass Spectrom. 2011, 22, 1157.
    • (2011) J. Am. Soc. Mass Spectrom. , vol.22 , pp. 1157
    • Elnaggar, M.S.1    Barbier, C.2    Van Berkel, G.J.3
  • 17
    • 81555215472 scopus 로고    scopus 로고
    • Liquid extraction surface analysis mass spectrometry (LESA-MS) as a novel profiling tool for drug distribution and metabolism analysis: The terfenadine example
    • D. Eikel, M. Vavrek, S. Smith, C. Bason, S. Yeh, W. A. Korfmacher, J. D. Henion,. Liquid extraction surface analysis mass spectrometry (LESA-MS) as a novel profiling tool for drug distribution and metabolism analysis: The terfenadine example. Rapid Commun. Mass Spectrom. 2011, 25, 3587.
    • (2011) Rapid Commun. Mass Spectrom. , vol.25 , pp. 3587
    • Eikel, D.1    Vavrek, M.2    Smith, S.3    Bason, C.4    Yeh, S.5    Korfmacher, W.A.6    Henion, J.D.7
  • 18
    • 79960936454 scopus 로고    scopus 로고
    • Direct sampling and analysis from solid phase extraction cards using an automated liquid extraction surface analysis nanoelectrospray mass spectrometry system
    • M. J. Walworth, M. S. ElNaggar, J. J. Stankovich, C. Witkowski, J. L. Norris, G. J. Van Berkel,. Direct sampling and analysis from solid phase extraction cards using an automated liquid extraction surface analysis nanoelectrospray mass spectrometry system. Rapid Commun. Mass Spectrom. 2011, 25, 2389.
    • (2011) Rapid Commun. Mass Spectrom. , vol.25 , pp. 2389
    • Walworth, M.J.1    Elnaggar, M.S.2    Stankovich, J.J.3    Witkowski, C.4    Norris, J.L.5    Van Berkel, G.J.6
  • 19
    • 70350675595 scopus 로고    scopus 로고
    • Application of a liquid extraction based sealing surface sampling probe for mass spectrometric analysis of dried blood spots and mouse-whole body thin tissue sections
    • G. J. Van Berkel, V. Kertesz,. Application of a liquid extraction based sealing surface sampling probe for mass spectrometric analysis of dried blood spots and mouse-whole body thin tissue sections. Anal. Chem. 2009, 81, 9146.
    • (2009) Anal. Chem. , vol.81 , pp. 9146
    • Van Berkel, G.J.1    Kertesz, V.2
  • 20
    • 72449175156 scopus 로고    scopus 로고
    • Direct quantitative bioanalysis of drugs in dried blood spots samples using a thin-layer chromatography mass spectrometer interface
    • P. Abu-Rabie, N. Spooner,. Direct quantitative bioanalysis of drugs in dried blood spots samples using a thin-layer chromatography mass spectrometer interface. Anal. Chem. 2009, 81, 10275.
    • (2009) Anal. Chem. , vol.81 , pp. 10275
    • Abu-Rabie, P.1    Spooner, N.2
  • 21
    • 79952012645 scopus 로고    scopus 로고
    • Sensitive determination of a drug candidate in dried blood spots using a TLC-MS interface integrated into a column switching LC-MS/MS system
    • K. Heinig, T. Wirz, A. Gajate-Perez,. Sensitive determination of a drug candidate in dried blood spots using a TLC-MS interface integrated into a column switching LC-MS/MS system. Bioanalysis 2010, 2, 1873.
    • (2010) Bioanalysis , vol.2 , pp. 1873
    • Heinig, K.1    Wirz, T.2    Gajate-Perez, A.3
  • 22
    • 84859641214 scopus 로고    scopus 로고
    • Dried matrix spot direct analysis: Evaluating the robustness of a direct elution technique for use in quantitative bioanalysis
    • P. Abu-Rabie, N. Spooner,. Dried matrix spot direct analysis: Evaluating the robustness of a direct elution technique for use in quantitative bioanalysis. Bioanalysis 2011, 3, 2769.
    • (2011) Bioanalysis , vol.3 , pp. 2769
    • Abu-Rabie, P.1    Spooner, N.2
  • 23
    • 80054870367 scopus 로고    scopus 로고
    • Exploration of a new concept for automated dried blood spot analysis using flow-through desorption and on-line SPE-MS/MS
    • J. A. Ooms, L. Knegt, E. H. M. Koster,. Exploration of a new concept for automated dried blood spot analysis using flow-through desorption and on-line SPE-MS/MS. Bioanalysis 2011, 3, 2311.
    • (2011) Bioanalysis , vol.3 , pp. 2311
    • Ooms, J.A.1    Knegt, L.2    Koster, E.H.M.3
  • 24
    • 84859104662 scopus 로고    scopus 로고
    • Direct analysis of dried blood spots coupled with mass spectrometry: Concepts and biomedical applications
    • J. Deglon, A. Thomas, P. Mangin, C. Staub,. Direct analysis of dried blood spots coupled with mass spectrometry: Concepts and biomedical applications. Anal. Bioanal. Chem. 2012, 402, 2485.
    • (2012) Anal. Bioanal. Chem. , vol.402 , pp. 2485
    • Deglon, J.1    Thomas, A.2    Mangin, P.3    Staub, C.4
  • 25
    • 0032010153 scopus 로고    scopus 로고
    • A universal algorithm for fast and automated charge state deconvolution of electrospray mass-to-charge ratio spectra
    • Z. Zhang, A. G. Marshall,. A universal algorithm for fast and automated charge state deconvolution of electrospray mass-to-charge ratio spectra. J. Am. Soc. Mass Spectrom. 1998, 9, 225.
    • (1998) J. Am. Soc. Mass Spectrom. , vol.9 , pp. 225
    • Zhang, Z.1    Marshall, A.G.2
  • 26
    • 46849092966 scopus 로고    scopus 로고
    • Comparison of drug distribution images from whole-body tissue thin sections obtained using desorption electrospray ionization and tandem mass spectrometry and autoradiography
    • V. Kertesz, G. J. Van Berkel, M. Vavrek, K. A. Koeplinger, B. B. Schneider, T. R. Covey,. Comparison of drug distribution images from whole-body tissue thin sections obtained using desorption electrospray ionization and tandem mass spectrometry and autoradiography. Anal. Chem. 2008, 80, 5168.
    • (2008) Anal. Chem. , vol.80 , pp. 5168
    • Kertesz, V.1    Van Berkel, G.J.2    Vavrek, M.3    Koeplinger, K.A.4    Schneider, B.B.5    Covey, T.R.6
  • 27
    • 78751520982 scopus 로고    scopus 로고
    • Hydrophobic treatment enabling analysis of wettable surface using a liquid microjunction surface sampling probe/electrospray ionization-mass spectrometry system
    • M. J. Walworth, J. J. Stankovich, G. J. Van Berkel, M. Schulz, S. Minarik, J. Nichols, E. Reich,. Hydrophobic treatment enabling analysis of wettable surface using a liquid microjunction surface sampling probe/electrospray ionization-mass spectrometry system. Anal. Chem. 2011, 83, 591.
    • (2011) Anal. Chem. , vol.83 , pp. 591
    • Walworth, M.J.1    Stankovich, J.J.2    Van Berkel, G.J.3    Schulz, M.4    Minarik, S.5    Nichols, J.6    Reich, E.7
  • 28
    • 79954624236 scopus 로고    scopus 로고
    • Hemoglobin variant analysis via direct surface sampling of dried blood spots coupled with high-resolution mass spectrometry
    • R. L. Edwards, A. J. Creese, M. Baumert, P. Griffiths, J. Bunch, H. J. Cooper,. Hemoglobin variant analysis via direct surface sampling of dried blood spots coupled with high-resolution mass spectrometry. Anal. Chem. 2011, 83, 2265.
    • (2011) Anal. Chem. , vol.83 , pp. 2265
    • Edwards, R.L.1    Creese, A.J.2    Baumert, M.3    Griffiths, P.4    Bunch, J.5    Cooper, H.J.6
  • 29
    • 85159255290 scopus 로고    scopus 로고
    • http://www.uniprot.org/uniprot/Q28745.
  • 30
    • 85159245809 scopus 로고    scopus 로고
    • http://www.uniprot.org/uniprot/P02075.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.