메뉴 건너뛰기




Volumn 8, Issue 3, 2013, Pages 379-393

Positioning error evaluation of GPU-based 3D ultrasound surgical navigation system for moving targets by using optical tracking system

Author keywords

CUDA; GPU; Image guided; Surgical navigation; Ultrasound

Indexed keywords

ABDOMINAL SURGERY; ARTICLE; BREATHING; CALCULATION; CONTROLLED STUDY; ECHOGRAPHY; ELECTRONICS; ERROR; FETUS SURGERY; GRAPHICS PROCESSING UNIT; HUMAN; IMAGE GUIDED ECHOGRAPHY; IMAGE PROCESSING; IMAGING SYSTEM; MEASUREMENT ACCURACY; MEDICAL DEVICE; MOTION; OPTICAL TRACKING SYSTEM; PHANTOM; POSITIONING ERROR; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; SURGICAL APPROACH; SURGICAL NAVIGATION SYSTEM; THREE DIMENSIONAL IMAGING;

EID: 84878012906     PISSN: 18616410     EISSN: 18616429     Source Type: Journal    
DOI: 10.1007/s11548-012-0789-z     Document Type: Article
Times cited : (9)

References (17)
  • 2
    • 0037980434 scopus 로고    scopus 로고
    • 3D ultrasound-based navigation for radiofrequency thermal ablation in the treatment of liver malignancies
    • 10.1007/s00464-002-9116-z 12632127 1:STN:280:DC%2BD3s3nvFakug%3D%3D 10.1007/s00464-002-9116-z
    • Sjolie E, Lango T, Ystgaard B, Tangen GA, Nagelhus Hernes TA, Marvik R (2003) 3D ultrasound-based navigation for radiofrequency thermal ablation in the treatment of liver malignancies. Surg Endosc 17(6): 933-938. doi: 10.1007/s00464-002-9116-z
    • (2003) Surg Endosc , vol.17 , Issue.6 , pp. 933-938
    • Sjolie, E.1    Lango, T.2    Ystgaard, B.3    Tangen, G.A.4    Nagelhus Hernes, T.A.5    Marvik, R.6
  • 3
    • 27744493685 scopus 로고    scopus 로고
    • Alignment of sparse freehand 3-D ultrasound with preoperative images of the liver using models of respiratory motion and deformation
    • 10.1109/TMI.2005.856751 16279078 10.1109/TMI.2005.856751
    • Blackall JM, Penney GP, King AP, Hawkes DJ (2005) Alignment of sparse freehand 3-D ultrasound with preoperative images of the liver using models of respiratory motion and deformation. IEEE Trans Med Imaging 24(11): 1405-1416. doi: 10.1109/TMI.2005.856751
    • (2005) IEEE Trans Med Imaging , vol.24 , Issue.11 , pp. 1405-1416
    • Blackall, J.M.1    Penney, G.P.2    King, A.P.3    Hawkes, D.J.4
  • 4
    • 34547592775 scopus 로고    scopus 로고
    • Feasibility of navigated resection of liver tumors using multiplanar visualization of intraoperative 3-dimensional ultrasound data
    • 10.1097/01.sla.0000264233.48306.99 17667508 10.1097/01.sla.0000264233. 48306.99
    • Beller S, Hunerbein M, Eulenstein S, Lange T, Schlag PM (2007) Feasibility of navigated resection of liver tumors using multiplanar visualization of intraoperative 3-dimensional ultrasound data. Ann Surg 246(2): 288-294. doi: 10.1097/01.sla.0000264233.48306.99
    • (2007) Ann Surg , vol.246 , Issue.2 , pp. 288-294
    • Beller, S.1    Hunerbein, M.2    Eulenstein, S.3    Lange, T.4    Schlag, P.M.5
  • 5
    • 34548410467 scopus 로고    scopus 로고
    • Recovery of respiratory motion and deformation of the liver using laparoscopic freehand 3D ultrasound system
    • 10.1016/j.media.2007.07.009 17822946 10.1016/j.media.2007.07.009
    • Nakamoto M, Hirayama H, Sato Y, Konishi K, Kakeji Y, Hashizume M, Tamura S (2007) Recovery of respiratory motion and deformation of the liver using laparoscopic freehand 3D ultrasound system. Med Image Anal 11(5): 429-442. doi: 10.1016/j.media.2007.07.009
    • (2007) Med Image Anal , vol.11 , Issue.5 , pp. 429-442
    • Nakamoto, M.1    Hirayama, H.2    Sato, Y.3    Konishi, K.4    Kakeji, Y.5    Hashizume, M.6    Tamura, S.7
  • 11
    • 59749102751 scopus 로고    scopus 로고
    • GPU-based interactive visualization framework for ultrasound datasets
    • 10.1002/cav.v20:1 10.1002/cav.279
    • Lim S, Kwon K, Shin B-S (2009) GPU-based interactive visualization framework for ultrasound datasets. Comput Animat Virtual Worlds 20(1): 11-23. doi: 10.1002/cav.v20:1
    • (2009) Comput Animat Virtual Worlds , vol.20 , Issue.1 , pp. 11-23
    • Lim, S.1    Kwon, K.2    Shin, B.-S.3
  • 12
    • 63649110322 scopus 로고    scopus 로고
    • Visualization and GPU-accelerated simulation of medical ultrasound from CT images
    • 10.1016/j.cmpb.2008.12.011 10.1016/j.cmpb.2008.12.011
    • Kutter O, Shams R, Navab N (2009) Visualization and GPU-accelerated simulation of medical ultrasound from CT images. Comput Methods Prog Biomed 94(3): 250-266. doi: 10.1016/j.cmpb.2008.12.011
    • (2009) Comput Methods Prog Biomed , vol.94 , Issue.3 , pp. 250-266
    • Kutter, O.1    Shams, R.2    Navab, N.3
  • 13
    • 80054863945 scopus 로고    scopus 로고
    • Medical ultrasound imaging: To GPU or not to GPU
    • 10.1109/MM.2011.65
    • So HKH, Junying C, Yiu BYS, Yu ACH (2011) Medical ultrasound imaging: to GPU or not to GPU. IEEE Micro 31(5): 54-65
    • (2011) IEEE Micro , vol.31 , Issue.5 , pp. 54-65
    • So, H.K.H.1    Junying, C.2    Yiu, B.Y.S.3    Yu, A.C.H.4
  • 14
    • 84890517975 scopus 로고
    • Least-squares fitting of two 3-d point sets
    • 21869429 1:STN:280:DC%2BC3MjovFyqtQ%3D%3D 10.1109/TPAMI.1987.4767965
    • Arun KS, Huang TS, Blostein SD (1987) Least-squares fitting of two 3-d point sets. IEEE Trans Pattern Anal Mach Intell 9(5): 698-700
    • (1987) IEEE Trans Pattern Anal Mach Intell , vol.9 , Issue.5 , pp. 698-700
    • Arun, K.S.1    Huang, T.S.2    Blostein, S.D.3
  • 16
    • 0028588488 scopus 로고
    • Ultrasound quantitation of respiratory organ motion in the upper abdomen
    • 10.1259/0007-1285-67-803-1096 7820402 1:STN:280:DyaK2M7itVeisA%3D%3D 10.1259/0007-1285-67-803-1096
    • Davies SC, Hill AL, Holmes RB, Halliwell M, Jackson PC (1994) Ultrasound quantitation of respiratory organ motion in the upper abdomen. Br J Radiol 67(803): 1096-1102. doi: 10.1259/0007-1285-67-803-1096
    • (1994) Br J Radiol , vol.67 , Issue.803 , pp. 1096-1102
    • Davies, S.C.1    Hill, A.L.2    Holmes, R.B.3    Halliwell, M.4    Jackson, P.C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.