-
1
-
-
35848938680
-
Finite element analysis of anterior lumbar intrbody fusion: Threaded cylindrical cage and pedicle screw fixation
-
Kim Y. Finite element analysis of anterior lumbar intrbody fusion: threaded cylindrical cage and pedicle screw fixation. Spine 2007; 32: 2558-2568.
-
(2007)
Spine
, vol.32
, pp. 2558-2568
-
-
Kim, Y.1
-
2
-
-
34447513136
-
Comparison of anterior-and posterior-approach instrumented lumbar interbody fusion for spondylolisthesis
-
Min JH, Jang JS, Lee SH. Comparison of anterior-and posterior-approach instrumented lumbar interbody fusion for spondylolisthesis. J Neurosurg Spine 2007; 7: 21-26.
-
(2007)
J Neurosurg Spine
, vol.7
, pp. 21-26
-
-
Min, J.H.1
Jang, J.S.2
Lee, S.H.3
-
3
-
-
0030473152
-
Adjacent-segment degeneration after lumbar fusion with instrumentation: A retrospective study
-
Rahm MD, Hall BB. Adjacent-segment degeneration after lumbar fusion with instrumentation: a retrospective study. J Spinal Disord 1996; 9: 392-400.
-
(1996)
J Spinal Disord
, vol.9
, pp. 392-400
-
-
Rahm, M.D.1
Hall, B.B.2
-
4
-
-
0034881417
-
Evaluation of the mobility of adjacent segments after posterior thoracolumbar fixation: A biomechanical study
-
Bastian L, Lange U, Knop C, Tusch C, Blauth M. Evaluation of the mobility of adjacent segments after posterior thoracolumbar fixation: a biomechanical study. Eur Spine J 2001; 10: 295-300.
-
(2001)
Eur Spine J
, vol.10
, pp. 295-300
-
-
Bastian, L.1
Lange, U.2
Knop, C.3
Tusch, C.4
Blauth, M.5
-
6
-
-
0027137831
-
The effects of immobilization of long segments of the spine on the adjacent and distal facet force and lumbosacral motion
-
Nagata H, Schendel MJ, Transfeldt EE, Lewis JL. The effects of immobilization of long segments of the spine on the adjacent and distal facet force and lumbosacral motion. Spine 1993; 18: 2471-2479.
-
(1993)
Spine
, vol.18
, pp. 2471-2479
-
-
Nagata, H.1
Schendel, M.J.2
Transfeldt, E.E.3
Lewis, J.L.4
-
7
-
-
12744268815
-
Surgical treatment of adjacent instability after lumbar spine fusion
-
Chen WJ, Lai PL, Niu CC, Chen LH, Fu TS, Wong CB. Surgical treatment of adjacent instability after lumbar spine fusion. Spine 2001; 26: E519-E524.
-
(2001)
Spine
, vol.26
-
-
Chen, W.J.1
Lai, P.L.2
Niu, C.C.3
Chen, L.H.4
Fu, T.S.5
Wong, C.B.6
-
9
-
-
0029919012
-
Lumbar motion segment pathology adjacent to thoracolumbar, lumbar, and lumbosacral fusions
-
Schlegel JD, Smith JA, Schleusener RL. Lumbar motion segment pathology adjacent to thoracolumbar, lumbar, and lumbosacral fusions. Spine 1996; 21: 970-981.
-
(1996)
Spine
, vol.21
, pp. 970-981
-
-
Schlegel, J.D.1
Smith, J.A.2
Schleusener, R.L.3
-
10
-
-
4444329571
-
Adjacent segment disease after lumbar or lumbosacral fusion: Review of the literature
-
Park P, Garton HJ, Gala VC, Hoff JT, McGillicuddy JE. Adjacent segment disease after lumbar or lumbosacral fusion: review of the literature. Spine 2004; 29: 1938-1944.
-
(2004)
Spine
, vol.29
, pp. 1938-1944
-
-
Park, P.1
Garton, H.J.2
Gala, V.C.3
Hoff, J.T.4
McGillicuddy, J.E.5
-
11
-
-
34548708963
-
Long-term actuarial survivorship analysis of an interspinous stabilization system
-
Senegas J, Vital JM, Pointillart V, Manqione Pl. Long-term actuarial survivorship analysis of an interspinous stabilization system. Eur Spine J 2007; 16: 1279-1287.
-
(2007)
Eur Spine J
, vol.16
, pp. 1279-1287
-
-
Senegas, J.1
Vital, J.M.2
Pointillart, V.3
Manqione, P.L.4
-
12
-
-
0036033686
-
Mechanical supplementation by non-rigid fixation in degenerative intervertebral lumbar segments: The Wallis system
-
Senegas J. Mechanical supplementation by non-rigid fixation in degenerative intervertebral lumbar segments: the Wallis system. Eur Spine J 2002; 11: 164-169.
-
(2002)
Eur Spine J
, vol.11
, pp. 164-169
-
-
Senegas, J.1
-
13
-
-
34548757246
-
A biomechanical evaluation of an interspinous device (Coflex) used to stabilize the lumbar spine
-
Tsai KJ, Murakami H, Lowery GL, Hutton WC. A biomechanical evaluation of an interspinous device (Coflex) used to stabilize the lumbar spine. J Surg Orthop Adv 2006; 15: 167-172.
-
(2006)
J Surg Orthop Adv
, vol.15
, pp. 167-172
-
-
Tsai, K.J.1
Murakami, H.2
Lowery, G.L.3
Hutton, W.C.4
-
14
-
-
0036571297
-
Measurement of cadaver lumbar spine motion segment stiffness
-
Brown MD, Holmes DC, Heiner AD. Measurement of cadaver lumbar spine motion segment stiffness. Spine 2002; 27: 918-922.
-
(2002)
Spine
, vol.27
, pp. 918-922
-
-
Brown, M.D.1
Holmes, D.C.2
Heiner, A.D.3
-
15
-
-
0032894508
-
Risk factors for adjacent-segment failure following lumbar fixation with rigid instrumentation for degenerative instability
-
Etebar S, Cahill DW. Risk factors for adjacent-segment failure following lumbar fixation with rigid instrumentation for degenerative instability. J Neurosurg 1999; 90: 163-169.
-
(1999)
J Neurosurg
, vol.90
, pp. 163-169
-
-
Etebar, S.1
Cahill, D.W.2
-
16
-
-
0034802078
-
Stress analysis of the disc adjacent to interbody fusion in lumbar spine
-
Chen CS, Cheng CK, Liu CL, Lo WH. Stress analysis of the disc adjacent to interbody fusion in lumbar spine. Med Eng Phys 2001; 23: 483-491.
-
(2001)
Med Eng Phys
, vol.23
, pp. 483-491
-
-
Chen, C.S.1
Cheng, C.K.2
Liu, C.L.3
Lo, W.H.4
-
17
-
-
18144451929
-
The biomechanical effect of postoperative hypolordosis in instrumented lumbar fusion on instrumented and adjacent spinal segments
-
Umehara S, Zindrick MR, Patwardhan AG, Havey RM, Vrbos LA, Knight GW, et al. The biomechanical effect of postoperative hypolordosis in instrumented lumbar fusion on instrumented and adjacent spinal segments. Spine 2000; 25: 1617-1624.
-
(2000)
Spine
, vol.25
, pp. 1617-1624
-
-
Umehara, S.1
Zindrick, M.R.2
Patwardhan, A.G.3
Havey, R.M.4
Vrbos, L.A.5
Knight, G.W.6
-
18
-
-
78650141938
-
Adjacent segment disease after interbody fusion and pedicle screw fixations for isolated L4-L5 spondylolisthesis a minimum five-year follow-up
-
Kim KH, Lee SH, Shim CS, Lee DY, Park HS, Pan WJ, et al. Adjacent segment disease after interbody fusion and pedicle screw fixations for isolated L4-L5 spondylolisthesis a minimum five-year follow-up. Spine 2010; 35: 625-634.
-
(2010)
Spine
, vol.35
, pp. 625-634
-
-
Kim, K.H.1
Lee, S.H.2
Shim, C.S.3
Lee, D.Y.4
Park, H.S.5
Pan, W.J.6
-
19
-
-
3042824007
-
Adjacent segment degeneration in the lumbar spine
-
Ghiselli G, Wang JC, Bhatia NN, Hsu WK, Dawson EG. Adjacent segment degeneration in the lumbar spine. J Bone Joint Surg Am 2004; 86: 1497-1503.
-
(2004)
J Bone Joint Surg Am
, vol.86
, pp. 1497-1503
-
-
Ghiselli, G.1
Wang, J.C.2
Bhatia, N.N.3
Hsu, W.K.4
Dawson, E.G.5
-
20
-
-
0032894508
-
Risk factors for adjacent-segment failure following lumbar fixation with rigid instrumentation for degenerative instability
-
Etebar S, Cahill DW. Risk factors for adjacent-segment failure following lumbar fixation with rigid instrumentation for degenerative instability. J Neurosurg 1999; 90: 163-169.
-
(1999)
J Neurosurg
, vol.90
, pp. 163-169
-
-
Etebar, S.1
Cahill, D.W.2
-
21
-
-
26244438031
-
Adjacent segment stenosis after lumbar fusion requiring second operation
-
Aiki H, Ohwada O, Kobayashi H, Hayakawa M, Kawaguchi S, Takebayashi T, et al. Adjacent segment stenosis after lumbar fusion requiring second operation. J Orthop Sci 2005; 10: 490-495.
-
(2005)
J Orthop Sci
, vol.10
, pp. 490-495
-
-
Aiki, H.1
Ohwada, O.2
Kobayashi, H.3
Hayakawa, M.4
Kawaguchi, S.5
Takebayashi, T.6
-
22
-
-
0026533222
-
Intraoperative measurement of lumbar spinal instability
-
Ebara S, Harada T, Hosono N, Inoue M, Tanaka M, Morimoto Y, et al. Intraoperative measurement of lumbar spinal instability. Spine 1992; 17: 44-50.
-
(1992)
Spine
, vol.17
, pp. 44-50
-
-
Ebara, S.1
Harada, T.2
Hosono, N.3
Inoue, M.4
Tanaka, M.5
Morimoto, Y.6
-
23
-
-
0142056033
-
Intraoperative biomechanical assessment of lumbar spinal instability: Validation of radiographic parameters indicating anterior column support in lumbar spinal fusion
-
Kanayama M, Hashimoto T, Shigenobu K, Oha F, Ishida T, Yamane S. Intraoperative biomechanical assessment of lumbar spinal instability: validation of radiographic parameters indicating anterior column support in lumbar spinal fusion. Spine 2003; 28: 2368-2372.
-
(2003)
Spine
, vol.28
, pp. 2368-2372
-
-
Kanayama, M.1
Hashimoto, T.2
Shigenobu, K.3
Oha, F.4
Ishida, T.5
Yamane, S.6
-
24
-
-
34447558123
-
New interspinous implant evaluation using an in vitro biomechanical study combined with a finite-element analysis
-
Lafage V, Gangnet N, Sénégas J, Lavaste F, Skalli W. New interspinous implant evaluation using an in vitro biomechanical study combined with a finite-element analysis. Spine 2007; 32: 1706-1713.
-
(2007)
Spine
, vol.32
, pp. 1706-1713
-
-
Lafage, V.1
Gangnet, N.2
Sénégas, J.3
Lavaste, F.4
Skalli, W.5
-
25
-
-
0036571294
-
Intraoperative measurement of lumbar spine motion segment stiffness
-
Brown MD, Holmes DC, Heiner AD, Wehman KF. Intraoperative measurement of lumbar spine motion segment stiffness. Spine 2002; 27: 954-958.
-
(2002)
Spine
, vol.27
, pp. 954-958
-
-
Brown, M.D.1
Holmes, D.C.2
Heiner, A.D.3
Wehman, K.F.4
-
26
-
-
67649135869
-
Does Wallis implant reduce adjacent segment degeneration above lumbosacral instrumented fusion?
-
Panagiotis K, Thomas R, Spyros Z, Zafiropoulos A. Does Wallis implant reduce adjacent segment degeneration above lumbosacral instrumented fusion? Eur Spine J 2009; 18: 830-840.
-
(2009)
Eur Spine J
, vol.18
, pp. 830-840
-
-
Panagiotis, K.1
Thomas, R.2
Spyros, Z.3
Zafiropoulos, A.4
-
27
-
-
34248556035
-
One-year outcome evaluation after interspinous implantation for degenerative spinal stenosis with segmental instability
-
Kong DS, Kim ES, Eoh W. One-year outcome evaluation after interspinous implantation for degenerative spinal stenosis with segmental instability. J Korean Med Sci 2007; 22: 330-335.
-
(2007)
J Korean Med Sci
, vol.22
, pp. 330-335
-
-
Kong, D.S.1
Kim, E.S.2
Eoh, W.3
|