메뉴 건너뛰기




Volumn 64, Issue 2, 2013, Pages 119-129

Strategies for reducing radiation exposure from multidetector computed tomography in the acute care setting

Author keywords

Computed tomography; Computed tomography dose index; Dose length product; Protocols; Radiation exposure; Strategies

Indexed keywords

ARTICLE; ARTIFACT; CLINICAL PROTOCOL; COMPUTER; COMPUTER PROGRAM; CONE BEAM COMPUTED TOMOGRAPHY; CONTRAST ENHANCEMENT; CONTRAST TO NOISE RATIO; ELECTRIC POTENTIAL; EMERGENCY CARE; EMERGENCY WARD; HEALTH CARE QUALITY; HUMAN; IMAGE QUALITY; KERNEL METHOD; MULTIDETECTOR COMPUTED TOMOGRAPHY; RADIATION DOSE REDUCTION; RADIATION EXPOSURE; RADIATION INDUCED NEOPLASM; RADIATION MONITORING; THICKNESS; X RAY;

EID: 84876557125     PISSN: 08465371     EISSN: 14882361     Source Type: Journal    
DOI: 10.1016/j.carj.2013.01.002     Document Type: Review
Times cited : (17)

References (66)
  • 2
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography - An increasing source of radiation exposure
    • DOI 10.1056/NEJMra072149
    • D.J. Brenner, and E.J. Hall Computed tomography: an increasing source of radiation exposure N Engl J Med 357 2007 2277 2284 (Pubitemid 350190758)
    • (2007) New England Journal of Medicine , vol.357 , Issue.22 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 3
    • 64949151537 scopus 로고    scopus 로고
    • Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults
    • A. Sodickson, P.F. Baeyens, and K.P. Andriole Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults Radiology 251 2009 175 184
    • (2009) Radiology , vol.251 , pp. 175-184
    • Sodickson, A.1    Baeyens, P.F.2    Andriole, K.P.3
  • 4
    • 73149113560 scopus 로고    scopus 로고
    • Projected cancer risks from computed tomographic scans performed in the United States in 2007
    • A. Berrington de Gonzalez, M. Mahesh, and K.P. Kim Projected cancer risks from computed tomographic scans performed in the United States in 2007 Arch Intern Med 169 2009 2071 2077
    • (2009) Arch Intern Med , vol.169 , pp. 2071-2077
    • Berrington De Gonzalez, A.1    Mahesh, M.2    Kim, K.P.3
  • 5
    • 77949419896 scopus 로고    scopus 로고
    • Radiologic and nuclear medicine studies in the United States and worldwide: Frequency, radiation dose, and comparison with other radiation sources - 1950-2007
    • F.A. Mettler, M. Bhargavan, and K. Faulkner Radiologic and nuclear medicine studies in the United States and worldwide: frequency, radiation dose, and comparison with other radiation sources - 1950-2007 Radiology 253 2009 520 531
    • (2009) Radiology , vol.253 , pp. 520-531
    • Mettler, F.A.1    Bhargavan, M.2    Faulkner, K.3
  • 6
    • 69349096036 scopus 로고    scopus 로고
    • Exposure to low-dose ionizing radiation from medical imaging procedures
    • R. Fazel, H.M. Krumholz, and Y. Wang Exposure to low-dose ionizing radiation from medical imaging procedures N Engl J Med 361 2009 849 857
    • (2009) N Engl J Med , vol.361 , pp. 849-857
    • Fazel, R.1    Krumholz, H.M.2    Wang, Y.3
  • 8
    • 0035902631 scopus 로고    scopus 로고
    • Excluding pulmonary embolism at the bedside without diagnostic imaging: Management of patients with suspected pulmonary embolism presenting to the emergency department by using a simple clinical model and D-dimer
    • P.S. Wells, D.R. Anderson, and M. Rodger Excluding pulmonary embolism at the bedside without diagnostic imaging: management of patients with suspected pulmonary embolism presenting to the emergency department by using a simple clinical model and d-dimer Ann Intern Med 135 2001 98 107 (Pubitemid 32661192)
    • (2001) Annals of Internal Medicine , vol.135 , Issue.2 , pp. 98-107
    • Wells, P.S.1    Anderson, D.R.2    Rodger, M.3    Stiell, I.4    Dreyer, J.F.5    Barnes, D.6    Forgie, M.7    Kovacs, G.8    Ward, J.9    Kovacs, M.J.10
  • 10
    • 84876540642 scopus 로고
    • The Canadian C-spine rule for radiography in alert and stable trauma patients
    • I.G. Stiell, G.A. Wells, and K.L. Vandemheen The Canadian C-spine rule for radiography in alert and stable trauma patients JAMA 2001 1841 286
    • (1841) JAMA , vol.2001 , pp. 286
    • Stiell, I.G.1    Wells, G.A.2    Vandemheen, K.L.3
  • 11
    • 84928095964 scopus 로고    scopus 로고
    • Can radiology professional society guidelines be converted to effective decision support?
    • R. Khorasani Can radiology professional society guidelines be converted to effective decision support? J Am Coll Radiol 7 2010 561 562
    • (2010) J Am Coll Radiol , vol.7 , pp. 561-562
    • Khorasani, R.1
  • 12
    • 44349104791 scopus 로고    scopus 로고
    • American College of Radiology Accessed June 8, 2011
    • American College of Radiology. ACR Appropriateness Criteria. Available at: http://www.acr.org/secondarymainmenucategories/quality-safety/app-criteria. aspx. Accessed June 8, 2011.
    • ACR Appropriateness Criteria
  • 13
    • 84857380279 scopus 로고    scopus 로고
    • Effect of computerized clinical decision support on the use and yield of CT pulmonary angiography in the emergency department
    • A.S. Raja, I.K. Ip, and L.M. Prevedello Effect of computerized clinical decision support on the use and yield of CT pulmonary angiography in the emergency department Radiology 262 2012 468 474
    • (2012) Radiology , vol.262 , pp. 468-474
    • Raja, A.S.1    Ip, I.K.2    Prevedello, L.M.3
  • 14
    • 63849157519 scopus 로고    scopus 로고
    • Cumulative radiation exposure and cancer risk estimates in emergency department patients undergoing repeat or multiple CT
    • R.T. Griffey, and A. Sodickson Cumulative radiation exposure and cancer risk estimates in emergency department patients undergoing repeat or multiple CT AJR Am J Roentgenol 192 2009 887 892
    • (2009) AJR Am J Roentgenol , vol.192 , pp. 887-892
    • Griffey, R.T.1    Sodickson, A.2
  • 15
    • 44349176789 scopus 로고    scopus 로고
    • Radiation safety in the era of helical CT: A patient-based protection program currently in place in two community hospitals in New Hampshire
    • S. Birnbaum Radiation safety in the era of helical CT: a patient-based protection program currently in place in two community hospitals in New Hampshire J Am Coll Radiol 5 2008 714 718.e5
    • (2008) J Am Coll Radiol , vol.5
    • Birnbaum, S.1
  • 16
    • 79960689293 scopus 로고    scopus 로고
    • Outside imaging in emergency department transfer patients: CD import reduces rates of subsequent imaging utilization
    • A. Sodickson, J. Opraseuth, and S. Ledbetter Outside imaging in emergency department transfer patients: CD import reduces rates of subsequent imaging utilization Radiology 260 2011 408 413
    • (2011) Radiology , vol.260 , pp. 408-413
    • Sodickson, A.1    Opraseuth, J.2    Ledbetter, S.3
  • 17
    • 84926231840 scopus 로고    scopus 로고
    • Using the Internet for image transfer in a regional trauma network: Effect on CT repeat rate, cost, and radiation exposure
    • P.T. Flanagan, A. Relyea-Chew, and J.A. Gross Using the Internet for image transfer in a regional trauma network: effect on CT repeat rate, cost, and radiation exposure J Am Coll Radiol 9 2012 648 656
    • (2012) J Am Coll Radiol , vol.9 , pp. 648-656
    • Flanagan, P.T.1    Relyea-Chew, A.2    Gross, J.A.3
  • 18
    • 84857862496 scopus 로고    scopus 로고
    • Reducing the rate of repeat imaging: Import of outside images to PACS
    • M.T. Lu, W.M. Tellis, and N. Fidelman Reducing the rate of repeat imaging: import of outside images to PACS AJR Am J Roentgenol 198 2012 628 634
    • (2012) AJR Am J Roentgenol , vol.198 , pp. 628-634
    • Lu, M.T.1    Tellis, W.M.2    Fidelman, N.3
  • 19
    • 77956028576 scopus 로고    scopus 로고
    • Massachusetts Medical Society Accessed September 9, 2011
    • Massachusetts Medical Society. Investigation of Defensive Medicine in Massachusetts. 2008. Available at: www.massmed.org/defensivemedicine. Accessed September 9, 2011.
    • (2008) Investigation of Defensive Medicine in Massachusetts
  • 20
    • 79957830946 scopus 로고    scopus 로고
    • The effect of self-referral on utilization of advanced diagnostic imaging
    • D.C. Levin, and V.M. Rao The effect of self-referral on utilization of advanced diagnostic imaging AJR Am J Roentgenol 196 2011 848 852
    • (2011) AJR Am J Roentgenol , vol.196 , pp. 848-852
    • Levin, D.C.1    Rao, V.M.2
  • 21
    • 0036831529 scopus 로고    scopus 로고
    • AAPM/RSNA Physics tutorial for residents: Topics in CT. Radiation dose in CT
    • M.F. McNitt-Gray AAPM/RSNA Physics tutorial for residents: topics in CT. Radiation dose in CT Radiographics 22 2002 1541 1553
    • (2002) Radiographics , vol.22 , pp. 1541-1553
    • McNitt-Gray, M.F.1
  • 23
    • 79955015001 scopus 로고    scopus 로고
    • CT dose index and patient dose: They are not the same thing
    • C.H. McCollough, S. Leng, and L. Yu CT dose index and patient dose: they are not the same thing Radiology 259 2011 311 316
    • (2011) Radiology , vol.259 , pp. 311-316
    • McCollough, C.H.1    Leng, S.2    Yu, L.3
  • 24
    • 79551676578 scopus 로고    scopus 로고
    • The feasibility of patient size-corrected, scanner-independent organ dose estimates for abdominal CT exams
    • A.C. Turner, D. Zhang, and M. Khatonabadi The feasibility of patient size-corrected, scanner-independent organ dose estimates for abdominal CT exams Med Phys 38 2011 820 829
    • (2011) Med Phys , vol.38 , pp. 820-829
    • Turner, A.C.1    Zhang, D.2    Khatonabadi, M.3
  • 25
    • 33846471867 scopus 로고    scopus 로고
    • Patient radiation doses from adult and pediatric CT
    • W. Huda, and A. Vance Patient radiation doses from adult and pediatric CT AJR Am J Roentgenol 188 2007 540
    • (2007) AJR Am J Roentgenol , vol.188 , pp. 540
    • Huda, W.1    Vance, A.2
  • 27
    • 63849158516 scopus 로고    scopus 로고
    • Assessment of patient dose in CT. NRPB-PE/1/2004
    • Accessed March 29, 2013
    • Shrimpton P. Assessment of patient dose in CT. NRPB-PE/1/2004. Chilton, England: National Radiological Protection Board, 2004. Also available at http://www.msct.eu/PDF-FILES/Appendix%20paediatric%20CT%20Dosimetry.pdf. Accessed March 29, 2013.
    • (2004) Chilton, England: National Radiological Protection Board
    • Shrimpton, P.1
  • 29
    • 77950600954 scopus 로고    scopus 로고
    • How effective is effective dose as a predictor of radiation risk?
    • C.H. McCollough, J.A. Christner, and J.M. Kofler How effective is effective dose as a predictor of radiation risk? AJR Am J Roentgenol 194 2010 890 896
    • (2010) AJR Am J Roentgenol , vol.194 , pp. 890-896
    • McCollough, C.H.1    Christner, J.A.2    Kofler, J.M.3
  • 30
    • 84856553013 scopus 로고    scopus 로고
    • Accessed February 4, 2013
    • Padilla A, Alquist EK. California Senate Bill 1237. 2010. Available at: http://info.sen.ca.gov/pub/09-10/bill/sen/sb-1201-1250/sb-1237-bill-20100929- chaptered.html. Accessed February 4, 2013.
    • (2010) California Senate Bill 1237
    • Padilla, A.1    Alquist, E.K.2
  • 33
    • 44349094357 scopus 로고    scopus 로고
    • The American College of Radiology Accessed September 9, 2011
    • The American College of Radiology. ACR Practice Guideline for Diagnostic Reference Levels in Medical X-Ray Imaging. 2008. Available at: www.acr.org/SecondaryMainMenuCategories/quality-safety/guidelines/med-phys/ reference-levels.aspx. Accessed September 9, 2011.
    • (2008) ACR Practice Guideline for Diagnostic Reference Levels in Medical X-Ray Imaging
  • 34
    • 1342266221 scopus 로고    scopus 로고
    • Strategies for CT radiation dose optimization
    • M.K. Kalra, M.M. Maher, and T.L. Toth Strategies for CT radiation dose optimization Radiology 230 2004 619
    • (2004) Radiology , vol.230 , pp. 619
    • Kalra, M.K.1    Maher, M.M.2    Toth, T.L.3
  • 36
    • 84856588732 scopus 로고    scopus 로고
    • The Alliance for Radiation Safety in Pediatric Imaging Accessed May 26, 2011
    • The Alliance for Radiation Safety in Pediatric Imaging. Image Gently. Available at: http://www.pedrad.org/associations/5364/ig/index.cfm?page=614. Accessed May 26, 2011.
    • Image Gently
  • 37
    • 77950614409 scopus 로고    scopus 로고
    • Image Gently: Ten steps you can take to optimize image quality and lower CT dose for pediatric patients
    • K.J. Strauss, M.J. Goske, and S.C. Kaste Image Gently: ten steps you can take to optimize image quality and lower CT dose for pediatric patients AJR Am J Roentgenol 194 2010 868
    • (2010) AJR Am J Roentgenol , vol.194 , pp. 868
    • Strauss, K.J.1    Goske, M.J.2    Kaste, S.C.3
  • 38
    • 0004234405 scopus 로고    scopus 로고
    • 3rd ed. Publicis Publishing Erlangen, Germany
    • W.A. Kalendar Computed Tomography 3rd ed. 2011 Publicis Publishing Erlangen, Germany
    • (2011) Computed Tomography
    • Kalendar, W.A.1
  • 39
    • 33645562681 scopus 로고    scopus 로고
    • CT dose reduction and dose management tools: Overview of available options
    • DOI 10.1148/rg.262055138
    • C.H. McCollough, M.R. Bruesewitz, and J.M. Kofler CT dose reduction and dose management tools: overview of available options Radiographics 26 2006 503 512 (Pubitemid 43515321)
    • (2006) Radiographics , vol.26 , Issue.2 , pp. 503-512
    • McCollough, C.H.1    Bruesewitz, M.R.2    Kofler Jr., J.M.3
  • 40
    • 84876563003 scopus 로고    scopus 로고
    • Variation in organ dose from abdomen-pelvis CT exams performed with tube current modulation (TCM): Evaluation of patient size effects
    • November 28-December 3 Chicago, IL
    • Sodickson A, Turner AC, McGlamery K, et al. Variation in organ dose from abdomen-pelvis CT exams performed with tube current modulation (TCM): evaluation of patient size effects. Paper presented at the 96th Scientific Assembly and Annual Meeting of the Radiographic Society of North America. November 28-December 3, 2010; Chicago, IL.
    • (2010) 96th Scientific Assembly and Annual Meeting of the Radiographic Society of North America
    • Sodickson, A.1    Turner, A.C.2    McGlamery, K.3
  • 41
    • 78649740074 scopus 로고    scopus 로고
    • Patient size and radiation exposure in thoracic, pelvic, and abdominal CT examinations performed with automatic exposure control
    • G.M. Israel, L. Cicchiello, and J. Brink Patient size and radiation exposure in thoracic, pelvic, and abdominal CT examinations performed with automatic exposure control AJR Am J Roentgenol 195 2010 1342
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 1342
    • Israel, G.M.1    Cicchiello, L.2    Brink, J.3
  • 43
    • 56149119702 scopus 로고    scopus 로고
    • Abdominal aorta: Evaluation with dual-source dual-energy multidetector CT after endovascular repair of aneurysms-initial observations
    • H. Chandarana, M.C.B. Godoy, and I. Vlahos Abdominal aorta: evaluation with dual-source dual-energy multidetector CT after endovascular repair of aneurysms-initial observations Radiology 249 2008 692 700
    • (2008) Radiology , vol.249 , pp. 692-700
    • Chandarana, H.1    Godoy, M.C.B.2    Vlahos, I.3
  • 44
    • 78549284651 scopus 로고    scopus 로고
    • Dual-energy computed tomography imaging of the aorta
    • I. Vlahos, M.C.B. Godoy, and D.P. Naidich Dual-energy computed tomography imaging of the aorta J Thorac Imaging 25 2010 289 300
    • (2010) J Thorac Imaging , vol.25 , pp. 289-300
    • Vlahos, I.1    Godoy, M.C.B.2    Naidich, D.P.3
  • 45
    • 34547583507 scopus 로고    scopus 로고
    • Split-bolus MDCT urography with synchronous nephrographic and excretory phase enhancement
    • L.C. Chow, S.W. Kwan, and E.W. Olcott Split-bolus MDCT urography with synchronous nephrographic and excretory phase enhancement AJR Am J Roentgenol 189 2007 314
    • (2007) AJR Am J Roentgenol , vol.189 , pp. 314
    • Chow, L.C.1    Kwan, S.W.2    Olcott, E.W.3
  • 46
    • 67650067593 scopus 로고    scopus 로고
    • Effects of adaptive section collimation on patient radiation dose in multisection spiral CT
    • P.D. Deak, O. Langner, and M. Lell Effects of adaptive section collimation on patient radiation dose in multisection spiral CT Radiology 252 2009 140
    • (2009) Radiology , vol.252 , pp. 140
    • Deak, P.D.1    Langner, O.2    Lell, M.3
  • 47
    • 0345015508 scopus 로고    scopus 로고
    • Radiation dose is reduced with a single-pass whole-body multi-detector row CT trauma protocol compared with a conventional segmented method: Initial experience
    • T. Ptak, J.T. Rhea, and R.A. Novelline Radiation dose is reduced with a single-pass whole-body multi-detector row CT trauma protocol compared with a conventional segmented method: initial experience Radiology 229 2003 902
    • (2003) Radiology , vol.229 , pp. 902
    • Ptak, T.1    Rhea, J.T.2    Novelline, R.A.3
  • 48
    • 58149263158 scopus 로고    scopus 로고
    • Evaluation of a single-pass continuous whole-body 16-MDCT protocol for patients with polytrauma
    • D. Nguyen, A. Platon, and K. Shanmuganathan Evaluation of a single-pass continuous whole-body 16-MDCT protocol for patients with polytrauma AJR Am J Roentgenol 192 2009 3
    • (2009) AJR Am J Roentgenol , vol.192 , pp. 3
    • Nguyen, D.1    Platon, A.2    Shanmuganathan, K.3
  • 49
    • 33947704171 scopus 로고    scopus 로고
    • Low-dose versus standard-dose CT protocol in patients with clinically suspected renal colic
    • P.A. Poletti, A. Platon, and O.T. Rutschmann Low-dose versus standard-dose CT protocol in patients with clinically suspected renal colic AJR Am J Roentgenol 188 2007 927
    • (2007) AJR Am J Roentgenol , vol.188 , pp. 927
    • Poletti, P.A.1    Platon, A.2    Rutschmann, O.T.3
  • 50
    • 77953948373 scopus 로고    scopus 로고
    • Intravenous contrast medium administration and scan timing at CT: Considerations and approaches
    • K.T. Bae Intravenous contrast medium administration and scan timing at CT: considerations and approaches Radiology 256 2010 32
    • (2010) Radiology , vol.256 , pp. 32
    • Bae, K.T.1
  • 51
    • 84871292595 scopus 로고    scopus 로고
    • Effects of patient size on radiation dose reduction and image quality in low-kVp CT pulmonary angiography performed with reduced IV contrast dose
    • A. Sodickson, and M. Weiss Effects of patient size on radiation dose reduction and image quality in low-kVp CT pulmonary angiography performed with reduced IV contrast dose Emerg Radiol 19 2012 437 445
    • (2012) Emerg Radiol , vol.19 , pp. 437-445
    • Sodickson, A.1    Weiss, M.2
  • 52
    • 22544435185 scopus 로고    scopus 로고
    • Comparison of different body size parameters for individual dose adaptation in body CT of adults
    • J. Menke Comparison of different body size parameters for individual dose adaptation in body CT of adults Radiology 236 2005 565
    • (2005) Radiology , vol.236 , pp. 565
    • Menke, J.1
  • 53
    • 67849094250 scopus 로고    scopus 로고
    • Low kVp imaging for dose reduction in dual-source cardiac CT
    • M. Luaces, S. Akers, and H. Litt Low kVp imaging for dose reduction in dual-source cardiac CT Int J Cardiovasc Imaging 25 2009 165 175
    • (2009) Int J Cardiovasc Imaging , vol.25 , pp. 165-175
    • Luaces, M.1    Akers, S.2    Litt, H.3
  • 54
    • 84876578843 scopus 로고    scopus 로고
    • CARE kV - Automated Dose-Optimized Selection of X-ray Tube Voltage
    • Accessed September 9, 2011
    • Grant K, Schmidt B. CARE kV - Automated Dose-Optimized Selection of X-ray Tube Voltage. White Paper. Siemens; 2011. Available at: http://www.medical. siemens.com/siemens/en-US/gg-ct-FBAs/files/Case-Studies/CarekV-White-Paper.pdf. Accessed September 9, 2011.
    • (2011) White Paper. Siemens
    • Grant, K.1    Schmidt, B.2
  • 55
    • 73649148717 scopus 로고    scopus 로고
    • Automatic selection of tube potential for radiation dose reduction in CT: A general strategy
    • L. Yu, H. Li, and J.G. Fletcher Automatic selection of tube potential for radiation dose reduction in CT: a general strategy Med Phys 37 2010 234 243
    • (2010) Med Phys , vol.37 , pp. 234-243
    • Yu, L.1    Li, H.2    Fletcher, J.G.3
  • 57
    • 79958042280 scopus 로고    scopus 로고
    • The obese emergency patient: Imaging challenges and solutions
    • M.J. Modica, K.M. Kanal, and M.L. Gunn The obese emergency patient: imaging challenges and solutions Radiographics 31 2011 811 823
    • (2011) Radiographics , vol.31 , pp. 811-823
    • Modica, M.J.1    Kanal, K.M.2    Gunn, M.L.3
  • 58
    • 84878703896 scopus 로고    scopus 로고
    • Thibault, Jean-Baptiste Accessed December 21, 2012
    • Thibault, Jean-Baptiste. Veo - CT Model-Based Iterative Reconstruction. Available at: http://www.gehealthcare.com/dose/pdfs/Veo-white-paper.pdf. Accessed December 21, 2012.
    • Veo - CT Model-Based Iterative Reconstruction
  • 59
    • 84876585599 scopus 로고    scopus 로고
    • Siemens Accessed December 21, 2012
    • Siemens. SAFIRE - Sinogram Affirmed Iterative Reconstruction. Available at: https://www.medical.siemens.com/siemens/en-INT/gg-ct-FBAs/files/brochures/ SAFIRE-Brochure.pdf. Accessed December 21, 2012.
    • SAFIRE - Sinogram Affirmed Iterative Reconstruction
  • 61
    • 82455199803 scopus 로고    scopus 로고
    • Philips Accessed December 21, 2012
    • Philips. iDose4 iterative reconstruction technique. Available at: http://www.healthcare.philips.com/pwc-hc/main/shared/Assets/Documents/ct/ idose-white-paper-452296267841.pdf. Accessed December 21, 2012.
    • IDose4 Iterative Reconstruction Technique
  • 62
    • 84928096642 scopus 로고    scopus 로고
    • Patient-centric radiation dose monitoring in the electronic health record: What are some of the barriers and key next steps?
    • A. Sodickson, and R. Khorasani Patient-centric radiation dose monitoring in the electronic health record: what are some of the barriers and key next steps? J Am Coll Radiol 7 2010 752 753
    • (2010) J Am Coll Radiol , vol.7 , pp. 752-753
    • Sodickson, A.1    Khorasani, R.2
  • 64
    • 81255161356 scopus 로고    scopus 로고
    • Informatics in radiology: RADIANCE: an automated, enterprise-wide solution for archiving and reporting CT radiation dose estimates
    • T.S. Cook, S.L. Zimmerman, and S.R. Steingall Informatics in radiology: RADIANCE: an automated, enterprise-wide solution for archiving and reporting CT radiation dose estimates Radiographics 31 2011 1833 1846
    • (2011) Radiographics , vol.31 , pp. 1833-1846
    • Cook, T.S.1    Zimmerman, S.L.2    Steingall, S.R.3
  • 65
    • 84864371144 scopus 로고    scopus 로고
    • Exposing exposure: Automated anatomy-specific CT radiation exposure extraction for quality assurance and radiation monitoring
    • A. Sodickson, G.I. Warden, and C.E. Farkas Exposing exposure: automated anatomy-specific CT radiation exposure extraction for quality assurance and radiation monitoring Radiology 264 2012 397 405
    • (2012) Radiology , vol.264 , pp. 397-405
    • Sodickson, A.1    Warden, G.I.2    Farkas, C.E.3
  • 66
    • 80054892076 scopus 로고    scopus 로고
    • Automated framework for digital radiation dose index reporting from CT dose reports
    • G. Shih, Z.F. Lu, and R. Zabih Automated framework for digital radiation dose index reporting from CT dose reports AJR Am J Roentgenol 197 2011 1170 1174
    • (2011) AJR Am J Roentgenol , vol.197 , pp. 1170-1174
    • Shih, G.1    Lu, Z.F.2    Zabih, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.