메뉴 건너뛰기




Volumn 25, Issue 4, 2010, Pages 289-300

Dual-energy computed tomography imaging of the aorta

Author keywords

aortic imaging; dual energy computed tomography; dual source computed tomography; low kilovoltage imaging; material specific imaging

Indexed keywords

IODINATED CONTRAST MEDIUM; IODINE; IOPROMIDE;

EID: 78549284651     PISSN: 08835993     EISSN: None     Source Type: Journal    
DOI: 10.1097/RTI.0b013e3181dc2b4c     Document Type: Conference Paper
Times cited : (42)

References (21)
  • 1
    • 67651085238 scopus 로고    scopus 로고
    • Basic principles and postprocessing techniques of dual-energy CT: Illustrated by selected congenital abnormalities of the thorax
    • Godoy MC, Naidich DP, Marchiori E, et al. Basic principles and postprocessing techniques of dual-energy CT: illustrated by selected congenital abnormalities of the thorax. J Thorac Imaging. 2009;24:152-159.
    • (2009) J Thorac Imaging. , vol.24 , pp. 152-159
    • Godoy, M.C.1    Naidich, D.P.2    Marchiori, E.3
  • 2
    • 67049110250 scopus 로고    scopus 로고
    • Vascular enhancement and image quality of MDCT pulmonary angiography in 400 cases: Comparison of standard and low kilovoltage settings
    • Matsuoka S, Hunsaker AR, Gill RR, et al. Vascular enhancement and image quality of MDCT pulmonary angiography in 400 cases: comparison of standard and low kilovoltage settings. AJR Am J Roentgenol. 2009;192:1651-1656.
    • (2009) AJR Am J Roentgenol. , vol.192 , pp. 1651-1656
    • Matsuoka, S.1    Hunsaker, A.R.2    Gill, R.R.3
  • 3
    • 33846695725 scopus 로고    scopus 로고
    • CT angiography of pulmonary arteries to detect pulmonary embolism: Improvement of vascular enhancement with low kilovoltage settings
    • Schueller-Weidekamm C, Schaefer-Prokop CM, Weber M, et al. CT angiography of pulmonary arteries to detect pulmonary embolism: improvement of vascular enhancement with low kilovoltage settings. Radiology. 2006;241:899-907.
    • (2006) Radiology. , vol.241 , pp. 899-907
    • Schueller-Weidekamm, C.1    Schaefer-Prokop, C.M.2    Weber, M.3
  • 4
    • 15344342736 scopus 로고    scopus 로고
    • Improved vascular opacification in cerebral computed tomography angiography with 80-kVp
    • Bahner ML, Bengel A, Brix G, et al. Improved vascular opacification in cerebral computed tomography angiography with 80-kVp. Invest Radiol. 2005;40:229-234.
    • (2005) Invest Radiol. , vol.40 , pp. 229-234
    • Bahner, M.L.1    Bengel, A.2    Brix, G.3
  • 5
    • 66849138266 scopus 로고    scopus 로고
    • The image quality and radiation dose of 100-kVp versus 120-kVp ECG-gated 16-slice CT coronary angiography
    • Park EA, Lee W, Kang JH, et al. The image quality and radiation dose of 100-kVp versus 120-kVp ECG-gated 16-slice CT coronary angiography. Korean J Radiol. 2009;10:235-243.
    • (2009) Korean J Radiol. , vol.10 , pp. 235-243
    • Park, E.A.1    Lee, W.2    Kang, J.H.3
  • 6
    • 67650790313 scopus 로고    scopus 로고
    • Is body weight the most appropriate criterion to select patients eligible for lowdose pulmonary CT angiography? Analysis of objective and subjective image quality at 80-kVp in 100 patients
    • Szucs-Farkas Z, Strautz T, Patak MA, et al. Is body weight the most appropriate criterion to select patients eligible for lowdose pulmonary CT angiography? Analysis of objective and subjective image quality at 80-kVp in 100 patients. Eur Radiol. 2009;19:1914-1922.
    • (2009) Eur Radiol. , vol.19 , pp. 1914-1922
    • Szucs-Farkas, Z.1    Strautz, T.2    Patak, M.A.3
  • 7
    • 59649088090 scopus 로고    scopus 로고
    • Patient exposure and image quality of low-dose pulmonary computed tomography angiography: Comparison of 100-and 80-kVp protocols
    • Szucs-Farkas Z, Kurmann L, Strautz T, et al. Patient exposure and image quality of low-dose pulmonary computed tomography angiography: comparison of 100-and 80-kVp protocols. Invest Radiol. 2008;43:871-876.
    • (2008) Invest Radiol. , vol.43 , pp. 871-876
    • Szucs-Farkas, Z.1    Kurmann, L.2    Strautz, T.3
  • 8
    • 65349110338 scopus 로고    scopus 로고
    • Image fusion in dual energy computed tomography: Effect on contrast enhancement, signal-to-noise ratio and image quality in computed tomography angiography
    • Behrendt FF, Schmidt B, Plumhans C, et al. Image fusion in dual energy computed tomography: effect on contrast enhancement, signal-to-noise ratio and image quality in computed tomography angiography. Invest Radiol. 2009; 44:1-6.
    • (2009) Invest Radiol. , vol.44 , pp. 1-6
    • Behrendt, F.F.1    Schmidt, B.2    Plumhans, C.3
  • 9
    • 61349119238 scopus 로고    scopus 로고
    • Image quality optimization and evaluation of linearly mixed images in dual-source, dualenergy CT
    • Yu L, Primak AN, Liu X, et al. Image quality optimization and evaluation of linearly mixed images in dual-source, dualenergy CT. Med Phys. 2009;36:1019-1024.
    • (2009) Med Phys. , vol.36 , pp. 1019-1024
    • Yu, L.1    Primak, A.N.2    Liu, X.3
  • 10
    • 67649111075 scopus 로고    scopus 로고
    • Multidetector computed tomography chest examinations with low-kilovoltage protocols in adults: Effect on image quality and radiation dose
    • Kim MJ, Park CH, Choi SJ, et al. Multidetector computed tomography chest examinations with low-kilovoltage protocols in adults: effect on image quality and radiation dose. J Comput Assist Tomogr. 2009;33:416-421.
    • (2009) J Comput Assist Tomogr. , vol.33 , pp. 416-421
    • Kim, M.J.1    Park, C.H.2    Choi, S.J.3
  • 11
    • 1442280959 scopus 로고    scopus 로고
    • MDCT evaluation of thoracic aortic anomalies in pediatric patients and young adults: Comparison of axial, multiplanar, and 3D images
    • Lee EY, Siegel MJ, Hildebolt CF, et al. MDCT evaluation of thoracic aortic anomalies in pediatric patients and young adults: comparison of axial, multiplanar, and 3D images. AJR Am J Roentgenol. 2004;182:777-784.
    • (2004) AJR Am J Roentgenol. , vol.182 , pp. 777-784
    • Lee, E.Y.1    Siegel, M.J.2    Hildebolt, C.F.3
  • 12
    • 1642389455 scopus 로고    scopus 로고
    • Lowkilovoltage multi-detector row chest CT in adults: Feasibility and effect on image quality and iodine dose
    • Sigal-Cinqualbre AB, Hennequin R, Abada HT, et al. Lowkilovoltage multi-detector row chest CT in adults: feasibility and effect on image quality and iodine dose. Radiology. 2004; 231:169-174.
    • (2004) Radiology. , vol.231 , pp. 169-174
    • Sigal-Cinqualbre, A.B.1    Hennequin, R.2    Abada, H.T.3
  • 13
    • 7944220516 scopus 로고    scopus 로고
    • Should low-kilovoltage chest CT protocols be the rule for pediatric patients?
    • author reply 1172
    • Paul JF, Abada HT, Sigal-Cinqualbre A. Should low-kilovoltage chest CT protocols be the rule for pediatric patients? AJR Am J Roentgenol. 2004;183:1172; author reply 1172.
    • (2004) AJR Am J Roentgenol. , vol.183 , pp. 1172
    • Paul, J.F.1    Abada, H.T.2    Sigal-Cinqualbre, A.3
  • 14
    • 56149119702 scopus 로고    scopus 로고
    • Abdominal aorta: Evaluation with dual-source dual-energy multidetector CT after endovascular repair of aneurysms-initial observations
    • Chandarana H, Godoy MC, Vlahos I, et al. Abdominal aorta: evaluation with dual-source dual-energy multidetector CT after endovascular repair of aneurysms-initial observations. Radiology. 2008;249:692-700.
    • (2008) Radiology. , vol.249 , pp. 692-700
    • Chandarana, H.1    Godoy, M.C.2    Vlahos, I.3
  • 15
    • 56149116093 scopus 로고    scopus 로고
    • Endoleaks after endovascular abdominal aortic aneurysm repair: Detection with dual-energy dual-source CT
    • Stolzmann P, Frauenfelder T, Pfammatter T, et al. Endoleaks after endovascular abdominal aortic aneurysm repair: detection with dual-energy dual-source CT. Radiology. 2008;249: 682-691.
    • (2008) Radiology. , vol.249 , pp. 682-691
    • Stolzmann, P.1    Frauenfelder, T.2    Pfammatter, T.3
  • 16
    • 33750299544 scopus 로고    scopus 로고
    • Lower tube voltage reduces contrast material and radiation doses on 16-MDCT aortography
    • Nakayama Y, Awai K, Funama Y, et al. Lower tube voltage reduces contrast material and radiation doses on 16-MDCT aortography. AJR Am J Roentgenol. 2006;187: W490-W497.
    • (2006) AJR Am J Roentgenol. , vol.187
    • Nakayama, Y.1    Awai, K.2    Funama, Y.3
  • 17
    • 61449268221 scopus 로고    scopus 로고
    • Minimizing contrast medium doses to diagnose pulmonary embolism with 80-kVp multidetector computed tomography in azotemic patients
    • Holmquist F, Hansson K, Pasquariello F, et al. Minimizing contrast medium doses to diagnose pulmonary embolism with 80-kVp multidetector computed tomography in azotemic patients. Acta Radiologica. 2009;50:181-193.
    • (2009) Acta Radiologica. , vol.50 , pp. 181-193
    • Holmquist, F.1    Hansson, K.2    Pasquariello, F.3
  • 18
    • 67651037373 scopus 로고    scopus 로고
    • Cervical and cranial computed tomographic angiography with automated bone removal: Dual energy computed tomography versus standard computed tomography
    • Morhard D, Fink C, Graser A, et al. Cervical and cranial computed tomographic angiography with automated bone removal: dual energy computed tomography versus standard computed tomography. Invest Radiol. 2009;44:293-297.
    • (2009) Invest Radiol. , vol.44 , pp. 293-297
    • Morhard, D.1    Fink, C.2    Graser, A.3
  • 19
    • 63449137864 scopus 로고    scopus 로고
    • Clinical evaluation of dual-energy bone removal in CT angiography of the head and neck: Comparison with conventional bone-subtraction CT angiography
    • Deng K, Liu C, Ma R, et al. Clinical evaluation of dual-energy bone removal in CT angiography of the head and neck: comparison with conventional bone-subtraction CT angiography. Clin Radiol. 2009;64:534-541.
    • (2009) Clin Radiol. , vol.64 , pp. 534-541
    • Deng, K.1    Liu, C.2    Ma, R.3
  • 20
    • 67651119947 scopus 로고    scopus 로고
    • Carotid computed tomography angiography with automated bone suppression: A comparative study between dual energy and bone subtraction techniques
    • Lell MM, Kramer M, Klotz E, et al. Carotid computed tomography angiography with automated bone suppression: a comparative study between dual energy and bone subtraction techniques. Invest Radiol. 2009;44:322-328.
    • (2009) Invest Radiol. , vol.44 , pp. 322-328
    • Lell, M.M.1    Kramer, M.2    Klotz, E.3
  • 21
    • 67651047052 scopus 로고    scopus 로고
    • The value of dual-energy bone removal in maximum intensity projections of lower extremity computed tomography angiography
    • Sommer WH, Johnson TR, Becker CR, et al. The value of dual-energy bone removal in maximum intensity projections of lower extremity computed tomography angiography. Invest Radiol. 2009;44:285-292.
    • (2009) Invest Radiol. , vol.44 , pp. 285-292
    • Sommer, W.H.1    Johnson, T.R.2    Becker, C.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.