메뉴 건너뛰기




Volumn 46, Issue 7, 2013, Pages 1328-1334

In vitro electro-mechanical characterization of human knee articular cartilage of different degeneration levels: A comparison with ICRS and Mankin scores

Author keywords

Cartilage degeneration; ICRS Mankin score; Mechanical properties; Parameter identification; Streaming potential integrals (SPI)

Indexed keywords

ARTICULAR CARTILAGES; ELECTRO-MECHANICAL; ELECTROMECHANICAL PROPERTY; HYDRAULIC PERMEABILITY; ICRS/MANKIN SCORE; MEASUREMENT TOOLS; NATURAL LOGARITHMS; STREAMING POTENTIAL;

EID: 84876304195     PISSN: 00219290     EISSN: 18732380     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2013.02.004     Document Type: Article
Times cited : (27)

References (35)
  • 1
    • 84876309660 scopus 로고    scopus 로고
    • Arthroscopic measurements of streaming potential integrals as a clinical approach for the quantification of cartilage degeneration
    • Würzburg, Germany.
    • Abedian, R., Reebmann, M., Hurschler, Christof, 2012. Arthroscopic measurements of streaming potential integrals as a clinical approach for the quantification of cartilage degeneration. In: Proceedings of the third International Congress on Strategies in Tissue Engineering, Würzburg, Germany.
    • (2012) Proceedings of the third International Congress on Strategies in Tissue Engineering
    • Abedian, R.1    Reebmann, M.2
  • 5
    • 79959714007 scopus 로고    scopus 로고
    • Streaming potential-based arthroscopic device is sensitive to cartilage changes immediately post-impact in an equine cartilage injury model
    • Changoor A., Coutu J.P., Garon M., Quenneville E., Hurtig M.B., Buschmann M.D. Streaming potential-based arthroscopic device is sensitive to cartilage changes immediately post-impact in an equine cartilage injury model. Journal of Biomechanical Engineering 2011, 133:061005.
    • (2011) Journal of Biomechanical Engineering , vol.133 , pp. 061005
    • Changoor, A.1    Coutu, J.P.2    Garon, M.3    Quenneville, E.4    Hurtig, M.B.5    Buschmann, M.D.6
  • 6
    • 77955105395 scopus 로고    scopus 로고
    • Effects of refrigeration and freezing on the electromechanical and biomechanical properties of articular cartilage
    • Changoor A., Fereydoonzad L., Yaroshinsky A., Buschmann M.D. Effects of refrigeration and freezing on the electromechanical and biomechanical properties of articular cartilage. Journal of Biomechanical Engineering 2010, 132:064502.
    • (2010) Journal of Biomechanical Engineering , vol.132 , pp. 064502
    • Changoor, A.1    Fereydoonzad, L.2    Yaroshinsky, A.3    Buschmann, M.D.4
  • 8
    • 0031106084 scopus 로고    scopus 로고
    • Streaming potentials during the confined compression creep test of normal and proteoglycan-depleted cartilage
    • Chen A.C., Nguyen T.T., Sah R.L. Streaming potentials during the confined compression creep test of normal and proteoglycan-depleted cartilage. Annals of Biomedical Engineering 1997, 25:269-277.
    • (1997) Annals of Biomedical Engineering , vol.25 , pp. 269-277
    • Chen, A.C.1    Nguyen, T.T.2    Sah, R.L.3
  • 10
    • 67349201415 scopus 로고    scopus 로고
    • An extended biphasic model for charged hydrated tissues with application to the intervertebral disc
    • Ehlers W., Karajan N., Markert B. An extended biphasic model for charged hydrated tissues with application to the intervertebral disc. Biomechanics and Modeling in Mechanobiology 2009, 8:233-251.
    • (2009) Biomechanics and Modeling in Mechanobiology , vol.8 , pp. 233-251
    • Ehlers, W.1    Karajan, N.2    Markert, B.3
  • 11
    • 0023276026 scopus 로고
    • Cartilage electromechanics-I. Electrokinetic transduction and the effects of electrolyte pH and ionic strength
    • Frank E.H., Grodzinsky A.J. Cartilage electromechanics-I. Electrokinetic transduction and the effects of electrolyte pH and ionic strength. Journal of Biomechanics 1987, 20:615-627.
    • (1987) Journal of Biomechanics , vol.20 , pp. 615-627
    • Frank, E.H.1    Grodzinsky, A.J.2
  • 12
    • 0023237655 scopus 로고
    • Cartilage electromechanics-II. A continuum model of cartilage electromechanics and correlation with experiments
    • Frank E.H., Grodzinsky A.J. Cartilage electromechanics-II. A continuum model of cartilage electromechanics and correlation with experiments. Journal of Biomechanics 1987, 20:629-639.
    • (1987) Journal of Biomechanics , vol.20 , pp. 629-639
    • Frank, E.H.1    Grodzinsky, A.J.2
  • 13
    • 0023637664 scopus 로고
    • Streaming potentials: a sensitive index of enzymatic degradation in articular cartilage
    • Frank E.H., Grodzinsky A.J., Koob T.J., Eyre D.R. Streaming potentials: a sensitive index of enzymatic degradation in articular cartilage. Journal of Orthopedic Research 1987, 5:497-508.
    • (1987) Journal of Orthopedic Research , vol.5 , pp. 497-508
    • Frank, E.H.1    Grodzinsky, A.J.2    Koob, T.J.3    Eyre, D.R.4
  • 14
    • 0036138583 scopus 로고    scopus 로고
    • Streaming potentials maps are spatially resolved indicators of amplitude, frequency and ionic strength dependant responses of articular cartilage to load
    • Garon M., Legare A., Guardo R., Savard P., Buschmann M.D. Streaming potentials maps are spatially resolved indicators of amplitude, frequency and ionic strength dependant responses of articular cartilage to load. Journal of Biomechanics 2002, 35:207-216.
    • (2002) Journal of Biomechanics , vol.35 , pp. 207-216
    • Garon, M.1    Legare, A.2    Guardo, R.3    Savard, P.4    Buschmann, M.D.5
  • 15
    • 0031060066 scopus 로고    scopus 로고
    • A triphasic analysis of negative osmotic flows through charged hydrated soft tissues
    • Gu W.Y., Lai W.M., Mow V.C. A triphasic analysis of negative osmotic flows through charged hydrated soft tissues. Journal of Biomechanics 1997, 30:71-78.
    • (1997) Journal of Biomechanics , vol.30 , pp. 71-78
    • Gu, W.Y.1    Lai, W.M.2    Mow, V.C.3
  • 17
    • 0029239621 scopus 로고
    • Comparison of optical, needle probe and ultrasonic techniques for the measurement of articular cartilage thickness
    • Jurvelin J.S., Rasanen T., Kolmonen P., Lyyra T. Comparison of optical, needle probe and ultrasonic techniques for the measurement of articular cartilage thickness. Journal of Biomechanics 1995, 28:231-235.
    • (1995) Journal of Biomechanics , vol.28 , pp. 231-235
    • Jurvelin, J.S.1    Rasanen, T.2    Kolmonen, P.3    Lyyra, T.4
  • 21
    • 2942534383 scopus 로고    scopus 로고
    • Indentation determined mechanoelectrochemical properties and fixed charge density of articular cartilage
    • Lu X.L., Sun D.D., Guo X.E., Chen F.H., Lai W.M., Mow V.C. Indentation determined mechanoelectrochemical properties and fixed charge density of articular cartilage. Annals of Biomedical Engineering 2004, 32:370-379.
    • (2004) Annals of Biomedical Engineering , vol.32 , pp. 370-379
    • Lu, X.L.1    Sun, D.D.2    Guo, X.E.3    Chen, F.H.4    Lai, W.M.5    Mow, V.C.6
  • 25
    • 0023161999 scopus 로고
    • Biphasic indentation of articular cartilage-I. Theoretical analysis
    • Mak A.F., Lai W.M., Mow V.C. Biphasic indentation of articular cartilage-I. Theoretical analysis. Journal of Biomechanics 1987, 20:703-714.
    • (1987) Journal of Biomechanics , vol.20 , pp. 703-714
    • Mak, A.F.1    Lai, W.M.2    Mow, V.C.3
  • 26
    • 0015021373 scopus 로고
    • Biochemical and metabolic aspects of osteoarthritis
    • Mankin H.J. Biochemical and metabolic aspects of osteoarthritis. Orthopedic Clinics of North America 1971, 2:19-31.
    • (1971) Orthopedic Clinics of North America , vol.2 , pp. 19-31
    • Mankin, H.J.1
  • 28
    • 0000915136 scopus 로고
    • Recent developments in synovial joint biomechanics
    • Mow C., Lai W. Michael Recent developments in synovial joint biomechanics. SIAM Review 1980, 22(3):275-317.
    • (1980) SIAM Review , vol.22 , Issue.3 , pp. 275-317
    • Mow, C.1    Lai, W.2
  • 29
    • 0024891692 scopus 로고
    • Biphasic indentation of articular cartilage-II. A numerical algorithm and an experimental study
    • Mow V.C., Gibbs M.C., Lai W.M., Zhu W.B., Athanasiou K.A. Biphasic indentation of articular cartilage-II. A numerical algorithm and an experimental study. Journal of Biomechanics 1989, 22:853-861.
    • (1989) Journal of Biomechanics , vol.22 , pp. 853-861
    • Mow, V.C.1    Gibbs, M.C.2    Lai, W.M.3    Zhu, W.B.4    Athanasiou, K.A.5
  • 31
    • 2442528180 scopus 로고    scopus 로고
    • The influence of the fixed negative charges on mechanical and electrical behaviors of articular cartilage under unconfined compression
    • Sun D.D., Guo X.E., Likhitpanichkul M., Lai W.M., Mow V.C. The influence of the fixed negative charges on mechanical and electrical behaviors of articular cartilage under unconfined compression. Journal of Biomechanical Engineering 2004, 126:6-16.
    • (2004) Journal of Biomechanical Engineering , vol.126 , pp. 6-16
    • Sun, D.D.1    Guo, X.E.2    Likhitpanichkul, M.3    Lai, W.M.4    Mow, V.C.5
  • 33
    • 35748959912 scopus 로고    scopus 로고
    • International Cartilage Repair Society (ICRS) and Oswestry macroscopic cartilage evaluation scores validated for use in Autologous Chondrocyte Implantation (ACI) and microfracture
    • van den Borne M.P., Raijmakers N.J., Vanlauwe J., Victor J., de Jong S.N., Bellemans J., Saris D.B. International Cartilage Repair Society (ICRS) and Oswestry macroscopic cartilage evaluation scores validated for use in Autologous Chondrocyte Implantation (ACI) and microfracture. Osteoarthritis and Cartilage 2007, 15:1397-1402.
    • (2007) Osteoarthritis and Cartilage , vol.15 , pp. 1397-1402
    • van den Borne, M.P.1    Raijmakers, N.J.2    Vanlauwe, J.3    Victor, J.4    de Jong, S.N.5    Bellemans, J.6    Saris, D.B.7
  • 35
    • 77956933007 scopus 로고    scopus 로고
    • Histology and research at the hard tissue-implant interface using Technovit 9100 New embedding technique
    • Willbold E., Witte F. Histology and research at the hard tissue-implant interface using Technovit 9100 New embedding technique. Acta Biomaterialia 2010, 6:4447-4455.
    • (2010) Acta Biomaterialia , vol.6 , pp. 4447-4455
    • Willbold, E.1    Witte, F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.