-
1
-
-
69249208489
-
Descemet's stripping endothelial keratoplasty: Safety and outcomes: A report by the American Academy of Ophthalmology
-
Lee WB, Jacobs DS, Musch DC, et al. Descemet's stripping endothelial keratoplasty: safety and outcomes: a report by the American Academy of Ophthalmology. Ophthalmology. 2009;116:1818-1830.
-
(2009)
Ophthalmology
, vol.116
, pp. 1818-1830
-
-
Lee, W.B.1
Jacobs, D.S.2
Musch, D.C.3
-
2
-
-
81355127406
-
Long-term results of Descemet stripping automated endothelial keratoplasty
-
Ratanasit A, Gorovoy MS. Long-term results of Descemet stripping automated endothelial keratoplasty. Cornea. 2011;30:1414-1418.
-
(2011)
Cornea
, vol.30
, pp. 1414-1418
-
-
Ratanasit, A.1
Gorovoy, M.S.2
-
3
-
-
33751110218
-
Descemet-stripping automated endothelial keratoplasty
-
DOI 10.1097/01.ico.0000214224.90743.01, PII 0000322620060900000005
-
Gorovoy MS. Descemet-stripping automated endothelial keratoplasty. Cornea. 2006;25:886-889. (Pubitemid 44763845)
-
(2006)
Cornea
, vol.25
, Issue.8
, pp. 886-889
-
-
Gorovoy, M.S.1
-
4
-
-
0031729571
-
A surgical technique for posterior lameliar keratoplasty
-
DOI 10.1097/00003226-199811000-00010
-
Melles GR, Eggink FA, Lander F, et al. A surgical technique for posterior lamellar keratoplasty. Cornea. 1998;17:618-626. (Pubitemid 28511909)
-
(1998)
Cornea
, vol.17
, Issue.6
, pp. 618-626
-
-
Melles, G.R.J.1
Eggink, F.A.G.J.2
Lander, F.3
Pels, E.4
Rietveld, F.J.R.5
Beekhuis, W.H.6
Binder, P.S.7
-
5
-
-
84876287317
-
Cornea preservation time study
-
National Eye Institute; Case Western Reserve Univesity Bethesda MD: National Library of Medicine http://clinicaltrials.gov/ct2/show/NCT01264276. Accessed on September 24 2012. NLM Identifier: NCT01537393
-
National Eye Institute; Case Western Reserve Univesity. Cornea Preservation Time Study. In: ClinicalTrials.gov. Bethesda, MD: National Library of Medicine; 2012-. Available at http://clinicaltrials.gov/ct2/show/NCT01537393; http://clinicaltrials.gov/ct2/show/NCT01264276. Accessed on September 24, 2012. NLM Identifier: NCT01537393.
-
(2012)
ClinicalTrials.gov
-
-
-
7
-
-
84876281824
-
Visual acuity and contrast sensitivity after posterior lamellar keratoplasty
-
[epub ahead of print]
-
Nielsen E, Hjortdal J. Visual acuity and contrast sensitivity after posterior lamellar keratoplasty. Acta Ophthalmol. 2011 [epub ahead of print].
-
(2011)
Acta Ophthalmol
-
-
Nielsen, E.1
Hjortdal, J.2
-
8
-
-
83455212187
-
Quality of vision in patients with Fuchs endothelial dystrophy and after Descemet stripping endothelial keratoplasty
-
van der Meulen IJ, Patel SV, Lapid-Gortzak R, et al. Quality of vision in patients with Fuchs endothelial dystrophy and after Descemet stripping endothelial keratoplasty. Arch Ophthalmol. 2011;129: 1537-1542.
-
(2011)
Arch Ophthalmol
, vol.129
, pp. 1537-1542
-
-
Van Der Meulen, I.J.1
Patel, S.V.2
Lapid-Gortzak, R.3
-
9
-
-
84862816162
-
Three-year visual acuity outcomes after Descemet's stripping automated endothelial keratoplasty
-
Li JY. Three-year visual acuity outcomes after Descemet's stripping automated endothelial keratoplasty. Ophthalmology. 2012;119:1126-1129.
-
(2012)
Ophthalmology
, vol.119
, pp. 1126-1129
-
-
Li, J.Y.1
-
10
-
-
33751077294
-
Descemet membrane endothelial keratoplasty (DMEK)
-
DOI 10.1097/01.ico.0000248385.16896.34, PII 0000322620060900000027
-
Melles GR, Ong TS, Ververs B, et al. Descemet membrane endothelial keratoplasty (DMEK). Cornea. 2006;25:987-990. (Pubitemid 44763867)
-
(2006)
Cornea
, vol.25
, Issue.8
, pp. 987-990
-
-
Melles, G.R.J.1
Ong, T.S.2
Ververs, B.3
Van Der Wees, J.4
-
11
-
-
82755197837
-
Descemet's membrane endothelial keratoplasty prospective study of 1-year visual outcomes, graft survival, and endothelial cell loss
-
Guerra FP, Anshu A, Price MO, et al. Descemet's membrane endothelial keratoplasty prospective study of 1-year visual outcomes, graft survival, and endothelial cell loss. Ophthalmology. 2011;118:2368-2373.
-
(2011)
Ophthalmology
, vol.118
, pp. 2368-2373
-
-
Guerra, F.P.1
Anshu, A.2
Price, M.O.3
-
12
-
-
70349281442
-
Endothelial cell density after Descemet membrane endothelial keratoplasty: 1-to 2-year follow-up
-
Ham L, van Luijk C, Dapena I, et al. Endothelial cell density after Descemet membrane endothelial keratoplasty: 1-to 2-year follow-up. Am J Ophthalmol. 2009;148:521-527.
-
(2009)
Am J Ophthalmol
, vol.148
, pp. 521-527
-
-
Ham, L.1
Van Luijk, C.2
Dapena, I.3
-
13
-
-
84930478678
-
Double-pass microkeratome technique for ultra-thin graft preparation in Descemet's stripping automated endothelial keratoplasty
-
Hsu M, Hereth WL, Moshirfar M. Double-pass microkeratome technique for ultra-thin graft preparation in Descemet's stripping automated endothelial keratoplasty. Clin Ophthalmol. 2012;6:425-432.
-
(2012)
Clin Ophthalmol
, vol.6
, pp. 425-432
-
-
Hsu, M.1
Hereth, W.L.2
Moshirfar, M.3
-
14
-
-
84858841092
-
Microkeratome-assisted preparation of ultrathin grafts for Descemet stripping automated endothelial keratoplasty
-
Busin M, Patel AK, Scorcia V, et al. Microkeratome-assisted preparation of ultrathin grafts for Descemet stripping automated endothelial keratoplasty. Invest Ophthalmol Vis Sci. 2012;53:521-524.
-
(2012)
Invest Ophthalmol Vis Sci
, vol.53
, pp. 521-524
-
-
Busin, M.1
Patel, A.K.2
Scorcia, V.3
-
15
-
-
84876289185
-
Descemet membrane endothelial keratoplasty: Is it time for you to convert from Descemet-stripping endothelial keratoplasty?
-
October 21 Orlando, FL
-
Price FW. Descemet membrane endothelial keratoplasty: is it time for you to convert from Descemet-stripping endothelial keratoplasty? Presented at: Cornea Subspecialty Day, American Academy of Ophthalmology; October 21, 2011; Orlando, FL.
-
(2011)
Cornea Subspecialty Day American Academy of Ophthalmology
-
-
Price, F.W.1
-
16
-
-
84867097872
-
Descemet's stripping automated endothelial keratoplasty: The tenuous relationship between donor thickness and postoperative vision
-
[epub ahead of print]
-
Terry MA, Straiko MD, Goshe JM, et al. Descemet's stripping automated endothelial keratoplasty: the tenuous relationship between donor thickness and postoperative vision. Ophthalmology. 2012 [epub ahead of print].
-
(2012)
Ophthalmology
-
-
Terry, M.A.1
Straiko, M.D.2
Goshe, J.M.3
-
17
-
-
80053631356
-
Descemet stripping automated endothelial keratoplasty: Effect of intraoperative lenticule thickness on visual outcome and endothelial cell density
-
Van Cleynenbreugel H, Remeijer L, Hillenaar T. Descemet stripping automated endothelial keratoplasty: effect of intraoperative lenticule thickness on visual outcome and endothelial cell density. Cornea. 2011;30:1195-1200.
-
(2011)
Cornea
, vol.30
, pp. 1195-1200
-
-
Van Cleynenbreugel, H.1
Remeijer, L.2
Hillenaar, T.3
-
18
-
-
33750289861
-
Descemet's stripping with endothelial keratoplasty. Comparative outcomes with microkeratome-dissected and manually dissected donor tissue
-
DOI 10.1016/j.ophtha.2006.05.034, PII S0161642006007202
-
Price MO, Price FW Jr. Descemet's stripping with endothelial keratoplasty: comparative outcomes with microkeratome-dissected and manually dissected donor tissue. Ophthalmology. 2006;113:1936-1942. (Pubitemid 44635703)
-
(2006)
Ophthalmology
, vol.113
, Issue.11
, pp. 1936-1942
-
-
Price, M.O.1
Price Jr., F.W.2
-
19
-
-
77957273179
-
Host and graft thickness after Descemet stripping endothelial keratoplasty for Fuchs endothelial dystrophy
-
e492
-
Ahmed KA, McLaren JW, Baratz KH, et al. Host and graft thickness after Descemet stripping endothelial keratoplasty for Fuchs endothelial dystrophy. Am J Ophthalmol. 2010;150:490-497 e492.
-
(2010)
Am J Ophthalmol
, vol.150
, pp. 490-497
-
-
Ahmed, K.A.1
McLaren, J.W.2
Baratz, K.H.3
-
20
-
-
84863393714
-
Impact of graft thickness on visual acuity after Descemet's stripping endothelial keratoplasty
-
Shinton AJ, Tsatsos M, Konstantopoulos A, et al. Impact of graft thickness on visual acuity after Descemet's stripping endothelial keratoplasty. Br J Ophthalmol. 2012;96:246-249.
-
(2012)
Br J Ophthalmol
, vol.96
, pp. 246-249
-
-
Shinton, A.J.1
Tsatsos, M.2
Konstantopoulos, A.3
-
21
-
-
79952989175
-
Comparison of central corneal graft thickness to visual acuity outcomes in endothelial keratoplasty
-
Neff KD, Biber JM, Holland EJ. Comparison of central corneal graft thickness to visual acuity outcomes in endothelial keratoplasty. Cornea. 2011;30:388-391.
-
(2011)
Cornea
, vol.30
, pp. 388-391
-
-
Neff, K.D.1
Biber, J.M.2
Holland, E.J.3
-
22
-
-
66749168957
-
Changes in donor corneal lenticule thickness after Descemet's stripping automated endothelial keratoplasty (DSAEK) with organ-cultured corneas
-
Pogorelov P, Cursiefen C, Bachmann BO, et al. Changes in donor corneal lenticule thickness after Descemet's stripping automated endothelial keratoplasty (DSAEK) with organ-cultured corneas. Br J Ophthalmol. 2009;93:825-829.
-
(2009)
Br J Ophthalmol
, vol.93
, pp. 825-829
-
-
Pogorelov, P.1
Cursiefen, C.2
Bachmann, B.O.3
-
23
-
-
67249126267
-
Central and peripheral corneal thickness measured with optical coherence tomography, Scheimpflug imaging, and ultrasound pachymetry in normal, keratoconus-suspect, and postlaser in situ keratomileusis eyes
-
Prospero Ponce CM, Rocha KM, Smith SD, et al. Central and peripheral corneal thickness measured with optical coherence tomography, Scheimpflug imaging, and ultrasound pachymetry in normal, keratoconus-suspect, and postlaser in situ keratomileusis eyes. J Cataract Refract Surg. 2009;35:1055-1062.
-
(2009)
J Cataract Refract Surg
, vol.35
, pp. 1055-1062
-
-
Prospero Ponce, C.M.1
Rocha, K.M.2
Smith, S.D.3
-
24
-
-
0036204821
-
Noncontact corneal pachymetry with slit lamp-adapted optical coherence tomography
-
DOI 10.1016/S0002-9394(01)01425-8, PII S0002939401014258
-
Wirbelauer C, Scholz C, Hoerauf H, et al. Noncontact corneal pachymetry with slit lamp-adapted optical coherence tomography. Am J Ophthalmol. 2002;133:444-450. (Pubitemid 34258054)
-
(2002)
American Journal of Ophthalmology
, vol.133
, Issue.4
, pp. 444-450
-
-
Wirbelauer, C.1
Scholz, C.2
Hoerauf, H.3
Pham, D.T.4
Laqua, H.5
Birngruber, R.6
-
25
-
-
34248590339
-
Comparison of central corneal thickness measurements by visante anterior segment optical coherence tomography with ultrasound pachymetry
-
DOI 10.1016/j.ajo.2007.01.050, PII S0002939407001213
-
Zhao PS, Wong TY, Wong WL, et al. Comparison of central corneal thickness measurements by Visante anterior segment optical coherence tomography with ultrasound pachymetry. Am J Ophthalmol. 2007;143:1047-1049. (Pubitemid 46764644)
-
(2007)
American Journal of Ophthalmology
, vol.143
, Issue.6
, pp. 1047-1049
-
-
Zhao, P.S.1
Wong, T.Y.2
Wong, W.-L.3
Saw, S.-M.4
Aung, T.5
-
26
-
-
38349182519
-
Comparison of central corneal thickness using anterior segment optical coherence tomography vs ultrasound pachymetry
-
Kim HY, Budenz DL, Lee PS, et al. Comparison of central corneal thickness using anterior segment optical coherence tomography vs ultrasound pachymetry. Am J Ophthalmol. 2008;145:228-232.
-
(2008)
Am J Ophthalmol
, vol.145
, pp. 228-232
-
-
Kim, H.Y.1
Budenz, D.L.2
Lee, P.S.3
-
27
-
-
84863789659
-
Corneal haze determined by confocal microscopy 2 years after Descemet stripping with endothelial keratoplasty for Fuchs corneal dystrophy
-
Baratz KH, McLaren JW, Maguire LJ, et al. Corneal haze determined by confocal microscopy 2 years after Descemet stripping with endothelial keratoplasty for Fuchs corneal dystrophy. Arch Ophthalmol. 2012;130: 868-874.
-
(2012)
Arch Ophthalmol
, vol.130
, pp. 868-874
-
-
Baratz, K.H.1
McLaren, J.W.2
Maguire, L.J.3
-
28
-
-
60549086170
-
The effect of corneal light scatter on vision after Descemet stripping with endothelial keratoplasty
-
Patel SV, Baratz KH, Hodge DO, et al. The effect of corneal light scatter on vision after Descemet stripping with endothelial keratoplasty. Arch Ophthalmol. 2009;127:153-160.
-
(2009)
Arch Ophthalmol
, vol.127
, pp. 153-160
-
-
Patel, S.V.1
Baratz, K.H.2
Hodge, D.O.3
-
29
-
-
84864448451
-
Anterior corneal aberrations after Descemet's stripping endothelial keratoplasty for Fuchs' endothelial dystrophy
-
Patel SV, Baratz KH, Maguire LJ, et al. Anterior corneal aberrations after Descemet's stripping endothelial keratoplasty for Fuchs' endothelial dystrophy. Ophthalmology. 2012;119:1522-1529.
-
(2012)
Ophthalmology
, vol.119
, pp. 1522-1529
-
-
Patel, S.V.1
Baratz, K.H.2
Maguire, L.J.3
-
30
-
-
81855170006
-
Graft thickness, graft folds, and aberrations after Descemet stripping endothelial keratoplasty for Fuchs dystrophy
-
Seery LS, Nau CB, McLaren JW, et al. Graft thickness, graft folds, and aberrations after Descemet stripping endothelial keratoplasty for Fuchs dystrophy. Am J Ophthalmol. 2011;152:910-916.
-
(2011)
Am J Ophthalmol
, vol.152
, pp. 910-916
-
-
Seery, L.S.1
Nau, C.B.2
McLaren, J.W.3
-
31
-
-
84876296896
-
Ultrathin" DSAEK tissue prepared with a low-pulse energy, high-frequency femtosecond laser
-
[epub ahead of print] doi:10.1097/ICO. 1090b1013e31825c31872dc
-
Phillips PM, Phillips LJ, Saad HA, et al. "Ultrathin" DSAEK tissue prepared with a low-pulse energy, high-frequency femtosecond laser. Cornea. 2012 [epub ahead of print]. doi:10.1097/ICO. 1090b1013e31825c31872dc.
-
(2012)
Cornea
-
-
Phillips, P.M.1
Phillips, L.J.2
Saad, H.A.3
|