Volumn 23, Issue 3, 2013, Pages 559-566

Intraoperative ultrasound guidance during intracavitary brachytherapy applicator placement in cervical cancer; The university of alabama at birmingham experience

Author keywords

Brachytherapy; Cervical cancer; Ultrasound

Indexed keywords

ADULT; AGED; ARTICLE; BRACHYTHERAPY; BRACHYTHERAPY IMPLANT; FEMALE; HUMAN; MAJOR CLINICAL STUDY; PEROPERATIVE ECHOGRAPHY; PRIORITY JOURNAL; RADIATION DOSE; UTERINE CERVIX CANCER; UTERUS PERFORATION;

EID: 84876268432     PISSN: 1048891X     EISSN: 15251438     Source Type: Journal    
DOI: 10.1097/IGC.0b013e3182859302     Document Type: Article
Times cited : (33)

References (25)
  • 1
    • 27144454512 scopus 로고    scopus 로고
    • Patterns of brachytherapy practice for patients with carcinoma of the cervix (1996-1999): A patterns of care study
    • Erickson B, Eifel P, Moughan J, et al. Patterns of brachytherapy practice for patients with carcinoma of the cervix (1996-1999): A patterns of care study. Int J Radiat Oncol Biol Phys. 2005;63:1083-1092.
    • (2005) Int J Radiat Oncol Biol Phys. , vol.63 , pp. 1083-1092
    • Erickson, B.1    Eifel, P.2    Moughan, J.3
  • 2
    • 0028340113 scopus 로고
    • Technically accurate intracavitary insertions improve pelvic control and survival among patients with locally advanced carcinoma of the uterine cervix
    • Corn BW, Hanlon AL, Pajak TF, et al. Technically accurate intracavitary insertions improve pelvic control and survival among patients with locally advanced carcinoma of the uterine cervix. Gynecol Oncol. 1994;53:294-300.
    • (1994) Gynecol Oncol. , vol.53 , pp. 294-300
    • Corn, B.W.1    Hanlon, A.L.2    Pajak, T.F.3
  • 3
    • 0034564179 scopus 로고    scopus 로고
    • Quantification of intracavitary brachytherapy parameters and correlation with outcome in patients with carcinoma of the cervix
    • Katz A, Eifel PJ. Quantification of intracavitary brachytherapy parameters and correlation with outcome in patients with carcinoma of the cervix. Int J Radiat Oncol Biol Phys. 2000;48:1417-1425.
    • (2000) Int J Radiat Oncol Biol Phys. , vol.48 , pp. 1417-1425
    • Katz, A.1    Eifel, P.J.2
  • 4
    • 0019494222 scopus 로고
    • Routine clinical estimation of rectal, rectosigmoidal, and bladder doses from intracavitary brachytherapy in the treatment of carcinoma of the cervix
    • Cunningham DE, Stryker JA, Velkley DE, et al. Routine clinical estimation of rectal, rectosigmoidal, and bladder doses from intracavitary brachytherapy in the treatment of carcinoma of the cervix. Int J Radiat Oncol Biol Phys. 1981;7:653-660.
    • (1981) Int J Radiat Oncol Biol Phys. , vol.7 , pp. 653-660
    • Cunningham, D.E.1    Stryker, J.A.2    Velkley, D.E.3
  • 5
    • 0034653303 scopus 로고    scopus 로고
    • Perioperative and postoperative complications of intracavitary radiation for FIGO stage IYIII carcinoma of the cervix
    • Jhingran A, Eifel PJ. Perioperative and postoperative complications of intracavitary radiation for FIGO stage IYIII carcinoma of the cervix. Int J Radiat Oncol Biol Phys. 2000;46:1177-1183.
    • (2000) Int J Radiat Oncol Biol Phys. , vol.46 , pp. 1177-1183
    • Jhingran, A.1    Eifel, P.J.2
  • 6
    • 0031080894 scopus 로고    scopus 로고
    • Intra-and perioperative complications associated with tandem and colpostat application for cervix cancer
    • Corn BW, Shaktman BD, Lanciano RM, et al. Intra-and perioperative complications associated with tandem and colpostat application for cervix cancer. Gynecol Oncol. 1997;64:224-229.
    • (1997) Gynecol Oncol. , vol.64 , pp. 224-229
    • Corn, B.W.1    Shaktman, B.D.2    Lanciano, R.M.3
  • 7
    • 0020622768 scopus 로고
    • Uterine perforation during intracavitary application. Prognostic significance in carcinoma of the cervix
    • Kim RY, Levy DS, Brascho DJ, et al. Uterine perforation during intracavitary application. Prognostic significance in carcinoma of the cervix. Radiology. 1983;147:249-251.
    • (1983) Radiology. , vol.147 , pp. 249-251
    • Kim, R.Y.1    Levy, D.S.2    Brascho, D.J.3
  • 8
    • 0027994035 scopus 로고
    • Ultrasound guidance for placement of difficult intracavitary implants
    • Rotmensch J, Waggoner SE, Quiet C. Ultrasound guidance for placement of difficult intracavitary implants. Gynecol Oncol. 1994;54:159-162.
    • (1994) Gynecol Oncol. , vol.54 , pp. 159-162
    • Rotmensch, J.1    Waggoner, S.E.2    Quiet, C.3
  • 10
    • 0025128696 scopus 로고
    • Ultrasound for diagnosing and preventing malplacement of intrauterine tandems
    • Granai CO, Doherty F, Allee P, et al. Ultrasound for diagnosing and preventing malplacement of intrauterine tandems. Obstet Gynecol. 1990;75:110-113.
    • (1990) Obstet Gynecol. , vol.75 , pp. 110-113
    • Granai, C.O.1    Doherty, F.2    Allee, P.3
  • 11
    • 34447298127 scopus 로고    scopus 로고
    • Prospective comparison of clinical and computed tomography assessment in detecting uterine perforation with intracavitary brachytherapy for carcinoma of the cervix
    • Barnes EA, Thomas G, Ackerman I, et al. Prospective comparison of clinical and computed tomography assessment in detecting uterine perforation with intracavitary brachytherapy for carcinoma of the cervix. Int J Gynecol Cancer. 2007;17:821-826.
    • (2007) Int J Gynecol Cancer. , vol.17 , pp. 821-826
    • Barnes, E.A.1    Thomas, G.2    Ackerman, I.3
  • 12
    • 82955196836 scopus 로고    scopus 로고
    • Should uterine tandem applicators ever be placed without ultrasound guidance? No: A brief report and review of the literature
    • Small W, Strauss JB, Hwang CS, et al. Should uterine tandem applicators ever be placed without ultrasound guidance? No: A brief report and review of the literature. Int J Gynecol Cancer. 2011;21:941-944.
    • (2011) Int J Gynecol Cancer. , vol.21 , pp. 941-944
    • Small, W.1    Strauss, J.B.2    Hwang, C.S.3
  • 13
    • 46849109296 scopus 로고    scopus 로고
    • Optimization of high-dose-rate cervix brachytherapy applicator placement: The benefits of intraoperative ultrasound guidance
    • Davidson M, Yuen J, D'Souza D, et al. Optimization of high-dose-rate cervix brachytherapy applicator placement: The benefits of intraoperative ultrasound guidance. Brachytherapy. 2008;7:248-253.
    • (2008) Brachytherapy. , vol.7 , pp. 248-253
    • Davidson, M.1    Yuen, J.2    D'Souza, D.3
  • 14
    • 72049083210 scopus 로고    scopus 로고
    • Three-dimensional imaging in gynecologic brachytherapy: A survey of the American Brachytherapy Society
    • Viswanathan AN, Erickson BA. Three-dimensional imaging in gynecologic brachytherapy: A survey of the American Brachytherapy Society. Int J Radiat Oncol Biol Phys. 2010;76:104-109.
    • (2010) Int J Radiat Oncol Biol Phys. , vol.76 , pp. 104-109
    • Viswanathan, A.N.1    Erickson, B.A.2
  • 15
    • 0027966959 scopus 로고
    • Perioperative morbidity of intracavitary gynecologic brachytherapy
    • Lanciano R, Corn B, Martin E, et al. Perioperative morbidity of intracavitary gynecologic brachytherapy. Int J Radiat Oncol Biol Phys. 1994;29:969-974.
    • (1994) Int J Radiat Oncol Biol Phys. , vol.29 , pp. 969-974
    • Lanciano, R.1    Corn, B.2    Martin, E.3
  • 16
    • 0032435418 scopus 로고    scopus 로고
    • Perioperative morbidity and mortality of high-dose-rate gynecologic brachytherapy
    • Petereit DG, Sarkaria JN, Chappell RJ. Perioperative morbidity and mortality of high-dose-rate gynecologic brachytherapy. Int J Radiat Oncol Biol Phys. 1998;42:1025-1031.
    • (1998) Int J Radiat Oncol Biol Phys. , vol.42 , pp. 1025-1031
    • Petereit, D.G.1    Sarkaria, J.N.2    Chappell, R.J.3
  • 17
    • 0022636484 scopus 로고
    • Uterine perforation at the time of brachytherapy for the carcinoma of the uterine cervix
    • Matsuyama T, Tsukamoto N, Matsukuma K, et al. Uterine perforation at the time of brachytherapy for the carcinoma of the uterine cervix. Gynecol Oncol. 1986;23:205-211.
    • (1986) Gynecol Oncol. , vol.23 , pp. 205-211
    • Matsuyama, T.1    Tsukamoto, N.2    Matsukuma, K.3
  • 18
    • 0024264555 scopus 로고
    • CT scanning in intracavitary therapy: Unexpected findings in ''straightforward'' insertions
    • Makin WP, Hunter RD. CT scanning in intracavitary therapy: Unexpected findings in ''straightforward'' insertions. Radiother Oncol. 1988;13:253-255.
    • (1988) Radiother Oncol. , vol.13 , pp. 253-255
    • Makin, W.P.1    Hunter, R.D.2
  • 19
    • 0022644995 scopus 로고
    • Intraoperative real-time ultrasonography during intrauterine tandem placement
    • Granai CO, Allee P, Doherty F, et al. Intraoperative real-time ultrasonography during intrauterine tandem placement. Obstet Gynecol. 1986;67:112-114.
    • (1986) Obstet Gynecol. , vol.67 , pp. 112-114
    • Granai, C.O.1    Allee, P.2    Doherty, F.3
  • 20
    • 0023335875 scopus 로고
    • Sonographic positioning of endouterine applicator
    • Tanaka S, Hishikawa Y, Kamikonya N, et al. Sonographic positioning of endouterine applicator. Radiat Med. 1987;5:92-93.
    • (1987) Radiat Med. , vol.5 , pp. 92-93
    • Tanaka, S.1    Hishikawa, Y.2    Kamikonya, N.3
  • 21
    • 0025126272 scopus 로고
    • The usefulness of ultrasonography in intracavitary radiotherapy using Selectron applicators
    • Wong F, Bhimji S. The usefulness of ultrasonography in intracavitary radiotherapy using Selectron applicators. Int J Radiat Oncol Biol Phys. 1990;19:477-482.
    • (1990) Int J Radiat Oncol Biol Phys. , vol.19 , pp. 477-482
    • Wong, F.1    Bhimji, S.2
  • 22
    • 0035290057 scopus 로고    scopus 로고
    • Invasive procedures in the female pelvis: Value of transabdominal, endovaginal, and endorectal US guidance
    • Scanlan KA, Propeck PA, Lee FT. Invasive procedures in the female pelvis: Value of transabdominal, endovaginal, and endorectal US guidance. Radiographics. 2001;21:491-506.
    • (2001) Radiographics. , vol.21 , pp. 491-506
    • Scanlan, K.A.1    Propeck, P.A.2    Lee, F.T.3
  • 23
    • 20044380933 scopus 로고    scopus 로고
    • Brachytherapy management of the retroverted uterus using ultrasound-guided implant applicator placement
    • Mayr N, Montebello J, Sorosky J, et al. Brachytherapy management of the retroverted uterus using ultrasound-guided implant applicator placement. Brachytherapy. 2005;4:24-29.
    • (2005) Brachytherapy. , vol.4 , pp. 24-29
    • Mayr, N.1    Montebello, J.2    Sorosky, J.3
  • 24
    • 79251568021 scopus 로고    scopus 로고
    • Ultrasound-guided tandem placement for low-dose-rate brachytherapy in advanced cervical cancer minimizes risk of intraoperative uterine perforation
    • Watkins JM, Kearney PL, Opfermann KJ, et al. Ultrasound-guided tandem placement for low-dose-rate brachytherapy in advanced cervical cancer minimizes risk of intraoperative uterine perforation. Ultrasound Obstet Gynecol. 2011;37:241-244.
    • (2011) Ultrasound Obstet Gynecol. , vol.37 , pp. 241-244
    • Watkins, J.M.1    Kearney, P.L.2    Opfermann, K.J.3
  • 25
    • 44449156329 scopus 로고    scopus 로고
    • External beam boost for cancer of the cervix uteri when intracavitary therapy cannot be performed
    • Barraclough LH, Swindell R, Livsey JE, et al. External beam boost for cancer of the cervix uteri when intracavitary therapy cannot be performed. Int J Radiat Oncol Biol Phys. 2008;71:772-778.
    • (2008) Int J Radiat Oncol Biol Phys. , vol.71 , pp. 772-778
    • Barraclough, L.H.1    Swindell, R.2    Livsey, J.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.