메뉴 건너뛰기




Volumn 40, Issue 4, 2013, Pages

Microionization chamber air-kerma calibration coefficients as a function of photon energy for x-ray spectra in the range of 20-250 kVp relative to 60Co

Author keywords

energy dependence; ionization chamber; low and medium energy x ray beams; microionization chamber

Indexed keywords

AGRICULTURE; CALIBRATION; DOSIMETRY; ELECTRODES; IONIZATION CHAMBERS; MICROCHANNELS; SILVER;

EID: 84876191881     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.4794491     Document Type: Article
Times cited : (18)

References (18)
  • 1
    • 0034973266 scopus 로고    scopus 로고
    • AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology
    • 10.1118/1.1374247
    • C.-M. Ma, C. W. Coffey, L. A. DeWerd, C. Liu, R. Nath, S. M. Seltzer, and J. P. Seuntjens, AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology., Med. Phys. 28, 868-893 (2001). 10.1118/1.1374247
    • (2001) Med. Phys. , vol.28 , pp. 868-893
    • Ma, C.-M.1    Coffey, C.W.2    Dewerd, L.A.3    Liu, C.4    Nath, R.5    Seltzer, S.M.6    Seuntjens, J.P.7
  • 2
    • 0021043263 scopus 로고
    • Measured influence of the central electrode diameter and material on the response of a graphite ionisation chamber to cobalt-60 gamma rays
    • 10.1088/0031-9155/28/11/007
    • M. Kristensen, Measured influence of the central electrode diameter and material on the response of a graphite ionisation chamber to cobalt-60 gamma rays., Phys. Med. Biol. 28, 1269-1278 (1983). 10.1088/0031-9155/28/11/007
    • (1983) Phys. Med. Biol. , vol.28 , pp. 1269-1278
    • Kristensen, M.1
  • 3
    • 0345495356 scopus 로고
    • Verification of a result of Kristensen by Monte Carlo modeling
    • 10.1088/0031-9155/29/10/013
    • V. G. Smyth and A. C. McEwan, Verification of a result of Kristensen by Monte Carlo modeling., Phys. Med. Biol. 29, 1279-1282 (1984). 10.1088/0031-9155/29/10/013
    • (1984) Phys. Med. Biol. , vol.29 , pp. 1279-1282
    • Smyth, V.G.1    McEwan, A.C.2
  • 4
    • 0027535624 scopus 로고
    • Effect of size and composition of the central electrode on the response of cylindrical ionization chambers in high-energy photon and electron beams
    • 10.1088/0031-9155/38/2/005
    • C. Ma and A. E. Nahum, Effect of size and composition of the central electrode on the response of cylindrical ionization chambers in high-energy photon and electron beams., Phys. Med. Biol. 38, 267-290 (1993). 10.1088/0031-9155/38/2/005
    • (1993) Phys. Med. Biol. , vol.38 , pp. 267-290
    • Ma, C.1    Nahum, A.E.2
  • 5
    • 0032940069 scopus 로고    scopus 로고
    • Experimental study on the influence of the central electrode in Farmer-type ionization chambers
    • A-150. 10.1088/0031-9155/44/5/315
    • Å. Palm and O. Mattsson, Experimental study on the influence of the central electrode in Farmer-type ionization chambers., Phys. Med. Biol. 44, 1299-1308 (1999). A-150. 10.1088/0031-9155/44/5/315
    • (1999) Phys. Med. Biol. , vol.44 , pp. 1299-1308
    • Palm, A.1    Mattsson, O.2
  • 6
    • 78149447290 scopus 로고    scopus 로고
    • Q, the beam quality conversion factor
    • 10.1118/1.3495537
    • Q, the beam quality conversion factor., Med. Phys. 37, 5939-5950 (2010). 10.1118/1.3495537
    • (2010) Med. Phys. , vol.37 , pp. 5939-5950
    • Muir, B.R.1    Rogers, D.W.O.2
  • 7
    • 79551679033 scopus 로고    scopus 로고
    • The central electrode correction factor for high-Z electrodes in small ionization chambers
    • 10.1118/1.3532818
    • B. R. Muir and D. W. O. Rogers, The central electrode correction factor for high-Z electrodes in small ionization chambers., Med. Phys. 38, 1081-1088 (2011). 10.1118/1.3532818
    • (2011) Med. Phys. , vol.38 , pp. 1081-1088
    • Muir, B.R.1    Rogers, D.W.O.2
  • 8
    • 69549129571 scopus 로고    scopus 로고
    • An evaluation of ionization chambers for the relative dosimetry of kilovoltage x-ray beams
    • 10.1118/1.3183820
    • R. Hill, Z. Mo, M. Haque, and C. Baldock, An evaluation of ionization chambers for the relative dosimetry of kilovoltage x-ray beams., Med. Phys. 36, 3971-3981 (2009). 10.1118/1.3183820
    • (2009) Med. Phys. , vol.36 , pp. 3971-3981
    • Hill, R.1    Mo, Z.2    Haque, M.3    Baldock, C.4
  • 9
    • 0031772889 scopus 로고    scopus 로고
    • ch) for the UK secondary standard ionization chamber (NE2561/NE2611) using medium-energy x-rays
    • 10.1088/0031-9155/43/11/003
    • ch) for the UK secondary standard ionization chamber (NE2561/NE2611) using medium-energy x-rays., Phys. Med. Biol. 43, 3195-3206 (1998). 10.1088/0031-9155/43/11/003
    • (1998) Phys. Med. Biol. , vol.43 , pp. 3195-3206
    • Rosser, K.E.1
  • 10
    • 51849129108 scopus 로고    scopus 로고
    • Thimble ionization chambers in medium-energy x-ray beams and the role of constructive details of central electrode: Monte Carlo simulations and measurements
    • 10.1088/0031-9155/53/18/003
    • F. Ubrich, J. Wulff, R. Kranzer, and K. Zink, Thimble ionization chambers in medium-energy x-ray beams and the role of constructive details of central electrode: Monte Carlo simulations and measurements., Phys. Med. Biol. 53, 4893-4906 (2008). 10.1088/0031-9155/53/18/003
    • (2008) Phys. Med. Biol. , vol.53 , pp. 4893-4906
    • Ubrich, F.1    Wulff, J.2    Kranzer, R.3    Zink, K.4
  • 11
    • 0031442330 scopus 로고    scopus 로고
    • Measurement of percentage depth dose and lateral beam profile for kilovoltage x-ray therapy beams
    • 10.1088/0031-9155/42/12/019
    • X. A. Li, C.-M. Ma, and D. Salhani, Measurement of percentage depth dose and lateral beam profile for kilovoltage x-ray therapy beams., Phys. Med. Biol. 42, 2561-2568 (1997). 10.1088/0031-9155/42/12/019
    • (1997) Phys. Med. Biol. , vol.42 , pp. 2561-2568
    • Li, X.A.1    Ma, C.-M.2    Salhani, D.3
  • 12
    • 67649892570 scopus 로고    scopus 로고
    • The influence of small field sizes, penumbra, spot size and measurement depth on perturbation factors for microionization chambers
    • 10.1088/0031-9155/54/9/024
    • F. Crop, N. Reynaert, G. Pittomvils, L. Paelinck, C. De Wagter, L. Vakaet, and H. Thierens, The influence of small field sizes, penumbra, spot size and measurement depth on perturbation factors for microionization chambers., Phys. Med. Biol. 54, 2951-2969 (2009). 10.1088/0031-9155/54/9/024
    • (2009) Phys. Med. Biol. , vol.54 , pp. 2951-2969
    • Crop, F.1    Reynaert, N.2    Pittomvils, G.3    Paelinck, L.4    Wagter, C.D.5    Vakaet, L.6    Thierens, H.7
  • 13
    • 77952340515 scopus 로고    scopus 로고
    • Q factors in megavoltage photon beams
    • 10.1118/1.3375895
    • Q factors in megavoltage photon beams., Med. Phys. 37, 2179-2193 (2010). 10.1118/1.3375895
    • (2010) Med. Phys. , vol.37 , pp. 2179-2193
    • McEwen, M.R.1
  • 14
    • 7244257424 scopus 로고    scopus 로고
    • The behavior of several microionizaton chambers in small intensity modulated radiotherapy fields
    • 10.1118/1.1788911
    • M. Stasi, B. Baiotto, G. Barboni, and G. Scielzo, The behavior of several microionizaton chambers in small intensity modulated radiotherapy fields., Med. Phys. 31, 2792-2795 (2004). 10.1118/1.1788911
    • (2004) Med. Phys. , vol.31 , pp. 2792-2795
    • Stasi, M.1    Baiotto, B.2    Barboni, G.3    Scielzo, G.4
  • 18
    • 36649023682 scopus 로고    scopus 로고
    • An experimental and computational investigation of the standard temperature-pressure correction factor for ion chambers and kilovoltage x rays
    • 10.1118/1.2799580
    • D. J. La Russa, M. McEwen, and D. W. O. Rogers, An experimental and computational investigation of the standard temperature-pressure correction factor for ion chambers and kilovoltage x rays., Med. Phys. 34, 4690-4699 (2007). 10.1118/1.2799580
    • (2007) Med. Phys. , vol.34 , pp. 4690-4699
    • La Russa, D.J.1    McEwen, M.2    Rogers, D.W.O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.