-
1
-
-
0034973266
-
AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology
-
10.1118/1.1374247
-
C.-M. Ma, C. W. Coffey, L. A. DeWerd, C. Liu, R. Nath, S. M. Seltzer, and J. P. Seuntjens, AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology., Med. Phys. 28, 868-893 (2001). 10.1118/1.1374247
-
(2001)
Med. Phys.
, vol.28
, pp. 868-893
-
-
Ma, C.-M.1
Coffey, C.W.2
Dewerd, L.A.3
Liu, C.4
Nath, R.5
Seltzer, S.M.6
Seuntjens, J.P.7
-
2
-
-
0021043263
-
Measured influence of the central electrode diameter and material on the response of a graphite ionisation chamber to cobalt-60 gamma rays
-
10.1088/0031-9155/28/11/007
-
M. Kristensen, Measured influence of the central electrode diameter and material on the response of a graphite ionisation chamber to cobalt-60 gamma rays., Phys. Med. Biol. 28, 1269-1278 (1983). 10.1088/0031-9155/28/11/007
-
(1983)
Phys. Med. Biol.
, vol.28
, pp. 1269-1278
-
-
Kristensen, M.1
-
3
-
-
0345495356
-
Verification of a result of Kristensen by Monte Carlo modeling
-
10.1088/0031-9155/29/10/013
-
V. G. Smyth and A. C. McEwan, Verification of a result of Kristensen by Monte Carlo modeling., Phys. Med. Biol. 29, 1279-1282 (1984). 10.1088/0031-9155/29/10/013
-
(1984)
Phys. Med. Biol.
, vol.29
, pp. 1279-1282
-
-
Smyth, V.G.1
McEwan, A.C.2
-
4
-
-
0027535624
-
Effect of size and composition of the central electrode on the response of cylindrical ionization chambers in high-energy photon and electron beams
-
10.1088/0031-9155/38/2/005
-
C. Ma and A. E. Nahum, Effect of size and composition of the central electrode on the response of cylindrical ionization chambers in high-energy photon and electron beams., Phys. Med. Biol. 38, 267-290 (1993). 10.1088/0031-9155/38/2/005
-
(1993)
Phys. Med. Biol.
, vol.38
, pp. 267-290
-
-
Ma, C.1
Nahum, A.E.2
-
5
-
-
0032940069
-
Experimental study on the influence of the central electrode in Farmer-type ionization chambers
-
A-150. 10.1088/0031-9155/44/5/315
-
Å. Palm and O. Mattsson, Experimental study on the influence of the central electrode in Farmer-type ionization chambers., Phys. Med. Biol. 44, 1299-1308 (1999). A-150. 10.1088/0031-9155/44/5/315
-
(1999)
Phys. Med. Biol.
, vol.44
, pp. 1299-1308
-
-
Palm, A.1
Mattsson, O.2
-
6
-
-
78149447290
-
Q, the beam quality conversion factor
-
10.1118/1.3495537
-
Q, the beam quality conversion factor., Med. Phys. 37, 5939-5950 (2010). 10.1118/1.3495537
-
(2010)
Med. Phys.
, vol.37
, pp. 5939-5950
-
-
Muir, B.R.1
Rogers, D.W.O.2
-
7
-
-
79551679033
-
The central electrode correction factor for high-Z electrodes in small ionization chambers
-
10.1118/1.3532818
-
B. R. Muir and D. W. O. Rogers, The central electrode correction factor for high-Z electrodes in small ionization chambers., Med. Phys. 38, 1081-1088 (2011). 10.1118/1.3532818
-
(2011)
Med. Phys.
, vol.38
, pp. 1081-1088
-
-
Muir, B.R.1
Rogers, D.W.O.2
-
8
-
-
69549129571
-
An evaluation of ionization chambers for the relative dosimetry of kilovoltage x-ray beams
-
10.1118/1.3183820
-
R. Hill, Z. Mo, M. Haque, and C. Baldock, An evaluation of ionization chambers for the relative dosimetry of kilovoltage x-ray beams., Med. Phys. 36, 3971-3981 (2009). 10.1118/1.3183820
-
(2009)
Med. Phys.
, vol.36
, pp. 3971-3981
-
-
Hill, R.1
Mo, Z.2
Haque, M.3
Baldock, C.4
-
9
-
-
0031772889
-
ch) for the UK secondary standard ionization chamber (NE2561/NE2611) using medium-energy x-rays
-
10.1088/0031-9155/43/11/003
-
ch) for the UK secondary standard ionization chamber (NE2561/NE2611) using medium-energy x-rays., Phys. Med. Biol. 43, 3195-3206 (1998). 10.1088/0031-9155/43/11/003
-
(1998)
Phys. Med. Biol.
, vol.43
, pp. 3195-3206
-
-
Rosser, K.E.1
-
10
-
-
51849129108
-
Thimble ionization chambers in medium-energy x-ray beams and the role of constructive details of central electrode: Monte Carlo simulations and measurements
-
10.1088/0031-9155/53/18/003
-
F. Ubrich, J. Wulff, R. Kranzer, and K. Zink, Thimble ionization chambers in medium-energy x-ray beams and the role of constructive details of central electrode: Monte Carlo simulations and measurements., Phys. Med. Biol. 53, 4893-4906 (2008). 10.1088/0031-9155/53/18/003
-
(2008)
Phys. Med. Biol.
, vol.53
, pp. 4893-4906
-
-
Ubrich, F.1
Wulff, J.2
Kranzer, R.3
Zink, K.4
-
11
-
-
0031442330
-
Measurement of percentage depth dose and lateral beam profile for kilovoltage x-ray therapy beams
-
10.1088/0031-9155/42/12/019
-
X. A. Li, C.-M. Ma, and D. Salhani, Measurement of percentage depth dose and lateral beam profile for kilovoltage x-ray therapy beams., Phys. Med. Biol. 42, 2561-2568 (1997). 10.1088/0031-9155/42/12/019
-
(1997)
Phys. Med. Biol.
, vol.42
, pp. 2561-2568
-
-
Li, X.A.1
Ma, C.-M.2
Salhani, D.3
-
12
-
-
67649892570
-
The influence of small field sizes, penumbra, spot size and measurement depth on perturbation factors for microionization chambers
-
10.1088/0031-9155/54/9/024
-
F. Crop, N. Reynaert, G. Pittomvils, L. Paelinck, C. De Wagter, L. Vakaet, and H. Thierens, The influence of small field sizes, penumbra, spot size and measurement depth on perturbation factors for microionization chambers., Phys. Med. Biol. 54, 2951-2969 (2009). 10.1088/0031-9155/54/9/024
-
(2009)
Phys. Med. Biol.
, vol.54
, pp. 2951-2969
-
-
Crop, F.1
Reynaert, N.2
Pittomvils, G.3
Paelinck, L.4
Wagter, C.D.5
Vakaet, L.6
Thierens, H.7
-
13
-
-
77952340515
-
Q factors in megavoltage photon beams
-
10.1118/1.3375895
-
Q factors in megavoltage photon beams., Med. Phys. 37, 2179-2193 (2010). 10.1118/1.3375895
-
(2010)
Med. Phys.
, vol.37
, pp. 2179-2193
-
-
McEwen, M.R.1
-
14
-
-
7244257424
-
The behavior of several microionizaton chambers in small intensity modulated radiotherapy fields
-
10.1118/1.1788911
-
M. Stasi, B. Baiotto, G. Barboni, and G. Scielzo, The behavior of several microionizaton chambers in small intensity modulated radiotherapy fields., Med. Phys. 31, 2792-2795 (2004). 10.1118/1.1788911
-
(2004)
Med. Phys.
, vol.31
, pp. 2792-2795
-
-
Stasi, M.1
Baiotto, B.2
Barboni, G.3
Scielzo, G.4
-
15
-
-
0003918015
-
-
NIST Special Publication 250-58, National Institute of Standards and Technology, Gaithersburg, Maryland
-
P. J. Lamperti and M. O'Brien, NIST measurement services: Calibration of x-ray and gamma-ray measuring instruments.. NIST Special Publication 250-58, National Institute of Standards and Technology, Gaithersburg, Maryland, 2001.
-
(2001)
NIST Measurement Services: Calibration of X-ray and Gamma-ray Measuring Instruments
-
-
Lamperti, P.J.1
O'Brien, M.2
-
18
-
-
36649023682
-
An experimental and computational investigation of the standard temperature-pressure correction factor for ion chambers and kilovoltage x rays
-
10.1118/1.2799580
-
D. J. La Russa, M. McEwen, and D. W. O. Rogers, An experimental and computational investigation of the standard temperature-pressure correction factor for ion chambers and kilovoltage x rays., Med. Phys. 34, 4690-4699 (2007). 10.1118/1.2799580
-
(2007)
Med. Phys.
, vol.34
, pp. 4690-4699
-
-
La Russa, D.J.1
McEwen, M.2
Rogers, D.W.O.3
|