-
1
-
-
84875976811
-
Effect of anastomosis angle on the localization of disturbed flow in side-to-end fistulae for haemodialysis access
-
Ene-Iordache B, Cattaneo L, Dubini G et al. Effect of anastomosis angle on the localization of disturbed flow in side-to-end fistulae for haemodialysis access. Nephrol Dial Transplant 2013; 28: 997-1005
-
Nephrol Dial Transplant
, vol.2013
, Issue.28
, pp. 997-1005
-
-
Ene-Iordache, B.1
Cattaneo, L.2
Dubini, G.3
-
2
-
-
34548508664
-
The operating surgeon is the major determinant for a successful arteriovenous fistula maturation
-
DOI 10.1038/sj.ki.5002206, PII 5002206
-
Basile C, Lomonte C. The operating surgeon is the major determinant for a successful arteriovenous fistula maturation. Kidney Int 2007; 72: 772 (Pubitemid 47373779)
-
(2007)
Kidney International
, vol.72
, Issue.6
, pp. 772
-
-
Basile, C.1
Lomonte, C.2
-
3
-
-
80053184905
-
Suboptimal initiation of dialysis with and without early referral to a nephrologist
-
Mendelssohn DC, Curtis B, Yeates K et al. Suboptimal initiation of dialysis with and without early referral to a nephrologist. Nephrol Dial Transplant 2011; 26: 2959-2965
-
(2011)
Nephrol Dial Transplant
, vol.26
, pp. 2959-2965
-
-
Mendelssohn, D.C.1
Curtis, B.2
Yeates, K.3
-
4
-
-
84856044998
-
The STARRT trial: A cost comparison of optimal vs sub-optimal initiation of dialysis in Canada
-
Piwko C, Vicente C, Marra L et al. The STARRT trial: a cost comparison of optimal vs sub-optimal initiation of dialysis in Canada. J Med Econ 2012; 15: 96-104
-
(2012)
J Med Econ
, vol.15
, pp. 96-104
-
-
Piwko, C.1
Vicente, C.2
Marra, L.3
-
5
-
-
0036379571
-
Increasing arteriovenous fistulas in hemodialysis patients: Problems and solutions
-
Allon M, Robbin ML. Increasing arteriovenous fistulas in hemodialysis patients: problems and solutions. Kidney Int 2002; 62: 1109-1124
-
(2002)
Kidney Int
, vol.62
, pp. 1109-1124
-
-
Allon, M.1
Robbin, M.L.2
-
6
-
-
44649135370
-
Hemodialysis arteriovenous fistula patency revisited: Results of a prospective, multicenter initiative
-
Huijbregts HJ, Bots ML, Wittens CH et al. Hemodialysis arteriovenous fistula patency revisited: results of a prospective, multicenter initiative. Clin J Am Soc Nephrol 2008; 3: 714-719
-
(2008)
Clin J Am Soc Nephrol
, vol.3
, pp. 714-719
-
-
Huijbregts, H.J.1
Bots, M.L.2
Wittens, C.H.3
-
7
-
-
33750687871
-
Risk equation determining unsuccessful cannulation events and failure to maturation in arteriovenous fistulas (REDUCE FTM I)
-
DOI 10.1681/ASN.2006030190
-
Lok CE, Allon M, Moist L et al. Risk equation determining unsuccessful cannulation events and failure to maturation in arteriovenous fistulas (REDUCE FTM I). J Am Soc Nephrol 2006; 17: 3204-3212 (Pubitemid 44707782)
-
(2006)
Journal of the American Society of Nephrology
, vol.17
, Issue.11
, pp. 3204-3212
-
-
Lok, C.E.1
Allon, M.2
Moist, L.3
Oliver, M.J.4
Shah, H.5
Zimmerman, D.6
-
8
-
-
82855177825
-
Should the arteriovenous fistula be created before starting dialysis? A decision analytic approach
-
Hiremath S, Knoll G, Weinstein MC. Should the arteriovenous fistula be created before starting dialysis? A decision analytic approach. PLoS ONE 2011; 6: e28453
-
(2011)
PLoS ONE
, vol.6
-
-
Hiremath, S.1
Knoll, G.2
Weinstein, M.C.3
-
9
-
-
0036268326
-
Native arteriovenous fistula: Preoperative evaluation
-
DOI 10.1053/ajkd.2002.33394
-
Malovrh M. Native arteriovenous fistula: preoperative evaluation. Am J Kidney Dis 2002; 39: 1218-1225 (Pubitemid 34591938)
-
(2002)
American Journal of Kidney Diseases
, vol.39
, Issue.6
, pp. 1218-1225
-
-
Malovrh, M.1
-
10
-
-
84875990927
-
Updates: Vascular access
-
National Kidney Foundation. KDOQI Clinical Practice Guidelines and Clinical Practice Recommendations for
-
National Kidney Foundation. KDOQI Clinical Practice Guidelines and Clinical Practice Recommendations for 2006 Updates: vascular access. Am J Kidney Dis 2006; 48 (suppl. 1): S179-S322
-
(2006)
Am J Kidney Dis
, vol.2006
, Issue.48 SUPPL. 1
-
-
-
11
-
-
0036314358
-
Tailoring the initial vascular access for dialysis patients
-
DOI 10.1046/j.1523-1755.2002.00436.x
-
Konner K, Hulbert-Shearon TE, Roys EC et al. Tailoring the initial vascular access for dialysis patients. Kidney Int 2002; 62: 329-338 (Pubitemid 34754079)
-
(2002)
Kidney International
, vol.62
, Issue.1
, pp. 329-338
-
-
Konner, K.1
Hulbert-Shearon, T.E.2
Roys, E.C.3
Port, F.K.4
-
12
-
-
0014020729
-
Chronic hemodialysis using venipuncture and a surgically created arteriovenous fistula
-
Brescia MJ, Cimino JE, Appel K et al. Chronic hemodialysis using venipuncture and a surgically created arteriovenous fistula. N Engl J Med 1966; 275: 1089-1092
-
(1966)
N Engl J Med
, vol.275
, pp. 1089-1092
-
-
Brescia, M.J.1
Cimino, J.E.2
Appel, K.3
-
14
-
-
0032622421
-
Accuracy of computational hemodynamics in complex arterial geometries reconstructed from magnetic resonance imaging
-
Moore JA, Steinman DA, Holdsworth DW et al. Accuracy of computational hemodynamics in complex arterial geometries reconstructed from magnetic resonance imaging. Ann Biomed Eng 1999; 27: 32-41
-
(1999)
Ann Biomed Eng
, vol.27
, pp. 32-41
-
-
Moore, J.A.1
Steinman, D.A.2
Holdsworth, D.W.3
-
15
-
-
56549111636
-
Hemodynamic wall shear stress profiles influence the magnitude and pattern of stenosis in a pig AV fistula
-
Krishnamoorthy MK, Banerjee RK, Wang Y et al. Hemodynamic wall shear stress profiles influence the magnitude and pattern of stenosis in a pig AV fistula. Kidney Int 2008; 74: 1410-1419
-
(2008)
Kidney Int
, vol.74
, pp. 1410-1419
-
-
Krishnamoorthy, M.K.1
Banerjee, R.K.2
Wang, Y.3
-
16
-
-
37349108589
-
Frequency of Swing-Segment Stenosis in Referred Dialysis Patients With Angiographically Documented Lesions
-
DOI 10.1053/j.ajkd.2007.09.012, PII S0272638607013078
-
Badero OJ, Salifu MO, Wasse H et al. Frequency of swingsegment stenosis in referred dialysis patients with angiographically documented lesions. Am J Kidney Dis 2008; 51: 93-98 (Pubitemid 350296513)
-
(2008)
American Journal of Kidney Diseases
, vol.51
, Issue.1
, pp. 93-98
-
-
Badero, O.J.1
Salifu, M.O.2
Wasse, H.3
Work, J.4
-
17
-
-
77951520918
-
Hemodynamic impact of anastomosis size and angle in side-to-end arteriovenous fistulae: A computer analysis
-
Van Canneyt K, Pourchez T, Eloot S et al. Hemodynamic impact of anastomosis size and angle in side-to-end arteriovenous fistulae: a computer analysis. J Vasc Access 2010; 11: 52-58
-
(2010)
J Vasc Access
, vol.11
, pp. 52-58
-
-
Van Canneyt, K.1
Pourchez, T.2
Eloot, S.3
-
18
-
-
77954144997
-
Can sites prone to flow induced vascular complications in a-v fistulas be assessed using computational fluid dynamics
-
Niemann AK, Udesen J, Thrysoe S et al. Can sites prone to flow induced vascular complications in a-v fistulas be assessed using computational fluid dynamics. J Biomech 2010; 43: 2002-2009
-
(2010)
J Biomech
, vol.43
, pp. 2002-2009
-
-
Niemann, A.K.1
Udesen, J.2
Thrysoe, S.3
-
19
-
-
83455200759
-
Clinical study protocol for the ARCH project-computational modeling for improvement of outcome after vascular access creation
-
Bode A, Caroli A, Huberts W et al. Clinical study protocol for the ARCH project-computational modeling for improvement of outcome after vascular access creation. J Vasc Access 2011; 12: 369-376
-
(2011)
J Vasc Access
, vol.12
, pp. 369-376
-
-
Bode, A.1
Caroli, A.2
Huberts, W.3
-
20
-
-
84859316477
-
Patient-specific computational modeling of upper extremity arteriovenous fistula creation: Its feasibility to support clinical decision-making
-
Bode AS, Huberts W, Bosboom EM et al. Patient-specific computational modeling of upper extremity arteriovenous fistula creation: its feasibility to support clinical decision-making. PLoS ONE 2012; 7: e34491
-
(2012)
PLoS ONE
, vol.7
-
-
Bode, A.S.1
Huberts, W.2
Bosboom, E.M.3
-
21
-
-
84856632883
-
Disturbed flow in radial-cephalic arteriovenous fistulae for haemodialysis; Low and oscillating shear stress locates the sites of stenosis
-
Ene-Iordache B, Remuzzi A. Disturbed flow in radial-cephalic arteriovenous fistulae for haemodialysis; low and oscillating shear stress locates the sites of stenosis. Nephrol Dial Transplant 2012; 27: 358-368
-
(2012)
Nephrol Dial Transplant
, vol.27
, pp. 358-368
-
-
Ene-Iordache, B.1
Remuzzi, A.2
|